Distinction. D4000 & D4000/EURO Water Still. Assembly and Operating Instructions. 1 Issue 2

Similar documents
INSTRUCTION MANUAL (English version) Water still

Assembly and Operating

TECHNOSKLO Ltd. Držkov

ASSEMBLY & OPERATING INSTRUCTIONS

LC3000 Level Controller Installation and Maintenance Instructions

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

SCHWAN INSTALLATION GUIDE

Water Purification 85

Manual / Handbuch Spare parts list / Ersatzteilliste

DOMESTIC STEAM GENERATOR Installation Instructions

Installation, operating and servicing instructions

Installation, Operating and Servicing Instructions

This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the voltages stated on the data plate.

TH100 Three in One Instant Hot Water Tap

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Water Purification. Quality distilled... the most reliable method of purifying water 81

Recirculating Cooler SRC14

DOMINATORPLUS ELECTRIC RANGE APPLIANCES INSTALLATION and SERVICING INSTRUCTIONS

Installation and Operating Manual Drying Cabinet

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

Lo-Carbon T-series Window & Roof Models

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

LO-LINE RC & LO-LINE RC HEATER/COOLER FAN CONVECTOR MODELS: 6-4, 9-6, 14-10,

Alpha CombiMax 350 and 600

HI-LINE RC & HI-LINE RC Heater/Cooler Models: 7-4, 10-6, 15-10, Installation, Operating, Maintenance and After Sales Manual.

SAFETY AND OPERATING MANUAL

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Water Distiller Service Manual

Miniboil Boiling Only

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

REMOTE COOLER AIR COOLED & WATER COOLED

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

The Professional s Choice

Aluminum Heating Mantles

User and Installation Instructions. Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SLIM-LINE RC. Installation, Operating, Maintenance and After Sales Manual. Please leave this manual with the end user. Part Number: Issue 3

HI-LINE LV FAN CONVECTOR MODEL: 7-4.

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

GAS HEATERS MODEL NOS: 900DV,1600DV & 2100DV PART NOS: , & USER INSTRUCTIONS ORIGINAL INSTRUCTIONS LS ISS 1

Model No: Little Devil II (inc ss)

LC2200 Level Controller Installation and Maintenance Instructions

USER MANUAL. Laboratory Refrigerator Range. Applicable models: LSR151 LSR288

Saturn Booster PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE AND KEEP THEM FOR FUTURE REFERENCE

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Rota- Spray Instructions (Mega Part & )

Unvented Electric Water Heater 10/15 litre Undersink

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

USER MANUAL. Pharmacy Refrigerator Range. Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151

4L Instant Water Boiler Instructions for Use

Unvented water heater

PERFORMANCE SHOWER PRODUCTS

Grant Spira 6-26kW and 9-36kW Wood Pellet Boilers

Energy. Installation guide

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

HOTPLATE COUNTERTOP AND OVEN RANGE

HEAVY DUTY BRASS SHOWER PUMPS

Water Bath SWB1 SWB2 SWB3 SWB1D SWB2D SWB3D. Instructions for use Version 2.0. water bath SWB2D. mains on on. press to set. set. off.

MHG201 Gas Hob Manual for Installation, Use and Maintenance

AUTOMATIC GRANULAR ICE FLAKER

Drying Cabinet Installation and Operating Manual

Issue 4 Oct Panamatic Top loading Maxi & Optima 3 Installation

CalMag Heating Pack Installation Instructions

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

SCHWAN INSTALLATION GUIDE

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

Autofill Wall Mount Boilers

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

The Classeq under counter range

Sanipack is a compact pump/macerator specially designed to take the waste from a wall hung or back to wall WC pan.

INSTALLATION & USER MANUAL

SUBMERSIBLE WATER PUMPS

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Zip HydroTap Miniboil

VERTICAL GLANDLESS PUMP

Installation & Operating Guide

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

VERSAFLOW VORTEX Supplementary instructions

n/a ROTARY JET ETCH/DEVELOPER TANK (RE)

Installation, Operating and Servicing Instructions

FITTING, OPERATION, INSTALLATION & SERVICING INSTRUCTIONS

USER INSTRUCTION MANUAL. Autofill Water Boiler

GAS HEATERS MODEL NOS: DEVIL 700, 900/910SS,1600/ 1610SS & 2100 PART NOS: , , , , , &

OPERATING AND MAINTENANCE MANUAL FOR VERTICAL IMMERSION HEATED STEAM BOILERS. Technical Control Systems Limited MODELS "VIHS"

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

MIX Boiler & Font Range Service Manual

ROTA-SPRAY PROCESSOR MODEL 1210 (ROTARY-JET) INSTRUCTIONS MEGA PART NO: &

WC2 & WC3 Installation & Maintenance Instructions

500 SERIES FOOD WASTE DISPOSERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR 523 SERIES SERIES SERIES 17

OWNERS INSTRUCTION MANUAL

Powerstock Storage Tank

Transcription:

Distinction D4000 & D4000/EURO Water Still Assembly and Operating Instructions 1 Issue 2

Fig. 1 Distinction D4000 & D4000/EURO Water Still 2 Issue 2

Before Use If the equipment is not used in the manner described in this manual the protection provided by the equipment may be impaired. N.B. The Distinction Water Still is classified as Permanently Connected Equipment and should be connected to the electricity supply by a qualified electrician in the manner described in the electrical installation section of this manual. The Distinction Water Still is designed to operate under the following conditions: - For indoor use - Ambient temperature range +5 C to +40 C - Altitude up to 2000m - Relative humidity not exceeding 80% - Mains supply voltage fluctuations not greater than ±10% of nominal - Overvoltage category II IEC60364-4-443 - Pollution degree 2 IEC664 3 Issue 2

Issue Date Reason 1 February 2014 Initial Issue 2 May 2015 Change to mains supply protection device. Contents Location p.5 Assembly p.6 Electrical Installation p.16 Operation p.18 Safety Cut-Outs p.18 Care and Maintenance p.20 Cleaning p.20 Heater Replacement p.22 Spares p.23 Fault Finding p.24 4 Issue 2

Location The Distinction Water Still can be wall or bench mounted. Select a convenient location which has access to the following services: Electrical Supply Before connection please ensure that the line supply is suitable. The Distinction Water Still is available in two models, model no. D4000 for supplies rated at 3kW, 220-240V 50/60 Hz single phase and model no. D4000/EURO for supplies rated at 3kW, 220-230V, 50/60 Hz, single phase. All units should be connected to the mains supply via a double pole 30mA Residual Current Breaker with overcurrent protection (RCBO) isolating circuit breaker rated at 15A. Water Supply A cold water supply capable of providing a minimum flow rate of 60 l/hr. Drain A waste water drain located below the level of the Still so that the drain pipe can fall away straight without kinks or bends, to allow an unimpeded flow. All water supplies and drainage systems should be properly earth bonded. Reservoir A distillate collection reservoir should be located beneath the Still. 5 Issue 2

Assembly 1. Unpack the Still and identify the following components: Qty. Component Catalogue No. 1. Support Stand - 1. Boiler I/D4000/B 1. Condenser I/WC48/M2/1 1. Heating Element D240H for D4000 D220H for D4000/EURO 1. Hose Kit I/W4000/HK 1. Gasket Kit I/DIST/GK 1. Boiler Thermostat Tube WTT48 1. Condenser Thermostat Tube I/A515414 2. White Plastic Screw Caps I/QC18/11 1. Silicone Rubber Ring I/QR18/7 1. Silicone Rubber Ring I/QR18/10 1. Reservoir Water Level Sensor I/D4000/WLS 2. Remove the end cover from the electrical compartment by undoing the retaining screws in the left hand panel as indicated in Fig. 2. Fig. 2 3. Take the metal stand and place in the desired location. Note that 2 screw holes are provided for wall mounting. If wall mounted, the unit should be secured using 38mm (1.5 ), No. 10 Screws. 6 Issue 2

4. Take the boiler, the heater and the gasket kit and assemble as shown in Fig. 3 and the following: i. Place the bolts through the metal flange in the manner shown and then place the metal flange over the tapered glass tube of the boiler. ii. iii. Take the plastic insert and bend it round the tapered glass tube of the boiler and into the metal flange. Pull the flange and insert towards the open end of the tapered glass tube until the insert presses on the glass. Place the aluminium plate, followed by the silicone ring over the heating element and locate approximately 40-45mm from the end with the electric cable, see Fig. 3. 40-45mm Tapered Glass Tube Boiler Heater ve Aluminium Plate Groove Silicone Ring Fig. 3 Plastic Insert Metal Flange iv. Insert the heating element through the tapered glass tube and into the boiler. Ensure that there is clearance at the inside end and no danger of the end of the element pressing against the end of the boiler. v. Insert the three bolts into the threaded holes in the aluminium plate and evenly tighten, do not fully tighten at this point. vi. Check the orientation of the heater cables at this point. They should fit straight into the terminal block as shown in Fig. 4. If not adjust position of heater element to achieve this position. 7 Issue 2

Fig. 4 vii. Tighten the three bolts equally and check that the element is secure and horizontal but do not over tighten bolts, as shown in Fig. 5. Fig. 5 5. Take the two metal straps with springs, and attach the springs to the rear of the cradles on the stand. 6. Uncoil the end of the boiler thermostat wire until approximately 250mm is straight as Fig. 6. 8 Issue 2

250mm Fig. 6 7. Remove the white plastic screw cap, boiler thermostat tube and o ring seal from the boiler. Place the o ring seal onto the boiler thermostat tube approximately 30mm from the end. Place the boiler thermostat tube into the boiler. Place the white screw cap onto the boiler thermostat wire as shown in Fig. 7. 30mm O Ring Seal Fig. 7 9 Issue 2

8. Place the boiler thermostat into the boiler thermostat tube. Slide the boiler assembly along keeping the 30mm distance on the boiler thermostat tube until the pip on the underside of the boiler fits into the hole on the right hand cradle. Tighten up the white screw cap. 9. Ensure the thermostat is fully inside the thermostat tube. Ensure that the thermostat wire is not touching any part of the chassis at the heater cable end. The thermostat should lay equidistance either side of the vapour tube as Fig. 8. Fig. 8 10. Attach the free ends of the straps to the front of the cradles to secure the boiler in place. 11. Connect the heater cable as shown in Fig. 9. - Push wires fully into the block. - Ensure screw terminations are tight. 10 Issue 2

Fig. 9 12. Ensure the Sealing O Ring and Stabilising O Ring are correctly positioned, as shown in Fig. 10. Distillate Outlet Fig. 10 11 Issue 2

13. Loosen the white screw cap (I/QC18/11) on the condenser thermostat tube (I/A515414). Fit the condenser thermostat tube to the vent of the condenser distillate outlet as Fig. 11. Ensure that the O ring silicone seal (I/QR18/7) fits onto the vent tube. Tighten the white plastic screw cap. Screwcap and Silicone Ring Fig. 11 14. Fit the condenser distillate outlet tubing and tie strap (not included). 15. Fit the condenser by mounting it onto the vapour tube of the boiler. Ensure the distillate outlet tube of the condenser faces the front and the cooling water outlet faces parallel to the unit as Fig. 10. When resistance is felt, push down slightly to create a seal until there is approximately a 5 10mm gap between the condenser and the boiler. 16. Fit the condenser thermostat into the condenser thermostat tube as Fig. 12. Arrange the thermostat wire so as not to obstruct the thermostat reset buttons. 12 Issue 2

Thermostat Reset Buttons Condenser Thermostat Wire Fig. 12 17. From the hose kit take the length of 8mm bore hose fitted with the plastic screw thread connectors at either end. Referring to Fig. 1, screw one end of the hose to the condenser outlet (upper) and the other end to the glass thread on the constant level control. 18. Refer to Fig. 13. Carefully attach the end of the short 16mm bore hose of hose assembly 1 to the outlet of the constant level control as Fig. 1, first warm the end of the hose with hot water to make the tubing more supple, and tie strap. From the hose kit take the 1000mm length of 16mm bore hose and attach to the free end of the earthed spigot. For ease of connection, first warm the end of the hose with hot water. Secure with the tie strap provided. Connect the 16mm tubing to the drain. Fig. 13 19. Lead the free end of the hose to drain, ensuring it falls away from the Still with no kinks or bends to impede the water flow. 20. Ensure that the stop cock on the constant level control is closed. 13 Issue 2

21. Refer to Fig. 14. Connect the cooling water inlet of the condenser (lower) to the connector of the 8mm bore hose of hose assembly 2. Connect the free end of the earthed spigot of hose assembly 2 to the cold water feed. Fig. 14 Select good quality tubing and secure all connections with hose clips. 22. Connect the distillate outlet of the condenser to a suitable collection reservoir. A glass reservoir system is available from Bibby Scientific Ltd. (Part No. WR20). Please contact the sales office for details. 23. Turn the cold water supply on, and check the unit for leaks. 24. Turn the cold water supply off. 25. Open the stop cock and drain the water. 26. Close the stop cock. 27. Remove the red cover from the constant level control funnel. 28. Refit end panel as Fig. 2. Fitting the Reservoir Water Level Control to Collection Vessels. 29. Position the distillate collection reservoir in a suitable location. This should be below the water still so that the tubing transporting the distilled water from the still can fall down to the reservoir without restrictions, kinks or U bends. Take the Reservoir Water Level Control (I/D4000/WLS) and connect the free end of the rubber tubing onto the nozzle of the pressure switch on the left hand end of the unit. See Fig. 1. Use the metal clip to fit the glass pressure bell inside the distillate collection reservoir. Refer to Fig. 15. Adjust the height of the pressure bell so that the open end is approximately 140mm below the maximum distillate level. 14 Issue 2

30. Ensure that the earthed spigot wires are connected to the earth point, as shown in Fig. 1. Fig. 15 15 Issue 2

Electrical Installation The electrical Installation should be carried out by a qualified electrician. The following method is recommended. The earthed spigots should pass a high current (i.e. >200mA) earth continuity test. The equipment is supplied with a 1.5m of PVC/PVC flexible, triple core, circular cable with the following specification, 1.5mm² to BS 6500 or equivalent and <HAR> or BASEC approved. The cable gland is designed to accept cable whose diameter is >7.0mm and <10.5mm. It is recommended that, at the connection to the mains electrical supply, there is fitted a 30mA RCD circuit breaker with a continuous current carrying capacity of 15 Amps at 250V, and rated at an overcurrent protection level of 15A. These devices should be sited near to the equipment and be clearly marked Disconnect device for Distinction Water Still. Note: Do not connect to electricity supply with a 13 Amp plug. Cable connections are shown in Fig. 9 & 16. Connect to the line supply noting that the wires in the instrument lead are coloured in accordance with the following code: Blue Neutral Brown Live Green & Yellow Earth Fig. 16 16 Issue 2

Main Cable Replacement If the mains cable requires replacement, only cable with the specification given above should be used. For live and neutral leads use bootlace crimps, size 1.5mm, with a performance conforming to BS 4G178 part 1, 1984 and part 2, 1986. For the earth lead use 1.5mm, M4 eyelet crimps with a performance conforming to BS 4G178 part 1, 1984 and part 2, 1986. A suitable crimp tool should be used. 17 Issue 2

Operation 1. Turn on the cold water supply and adjust the flow to approximately 60 l/hr. Observe that the water flows via the condenser and into the boiler. Wait until the boiler has attained its correct operating level and make sure that the excess water is flowing freely to drain. 2. Switch on the heating element. The on/off switch is located on the front panel. See Fig. 1. 3. After a few minutes the water will start to boil and distillate will emerge from the condenser. With new glassware, or after cleaning, it is advisable to allow this to run to drain for approximately 30 minutes before beginning collection. 4. To turn off the still, first turn off the heating element but allow cooling water to continue for a further 10 minutes to allow the still to cool. Warning! Do not use this equipment to distil any liquid other than water. Safety Cut-Outs The Distinction Water Still is protected by the following safety cut-outs: 1. Reservoir Water Level Control This should be positioned in the collecting reservoir (See Assembly) and turns off the heating element when the reservoir is full. 2. Condenser Thermostat Mounted in the condenser s distillate outlet. Should the water supply be interrupted, steam will begin to emerge from the condenser causing the thermostat to operate and turn off the electricity supply to the heating element. 3. Boiler Thermostat Mounted in the boiler above the heating element. Should the boiler water level fall and expose the element the thermostat will operate and turn off the electricity supply to the element. After operation of either of the thermostats, normal operation may be resumed by resetting the thermostat by means of their respective reset buttons mounted on the right hand end panel of the electrical compartment. 18 Issue 2

Remove the black plastic cover and then press the red button a slight click will be heard if the thermostat had operated. If the thermostats continue to operate, consult a qualified electrician or the Technical Service Department of Bibby Scientific Ltd. 19 Issue 2

Care and Maintenance N.B. Before commencing any maintenance, cleaning or fault finding the equipment should be isolated from the mains electricity supply. These operations should only be carried out by suitably qualified personnel. Only spare parts supplied or approved by Bibby Scientific Ltd or its agent should be used. Fitting of non-approved parts may affect the performance or safety of the equipment. Cleaning Over a period of operation, scale will build up inside the boiler. To obtain optimum performance this scale should be removed on a regular basis. Please note that scale can build up both in the neck and main body of the boiling chamber. The time span between cleaning depends greatly on the hardness of the water and the amount of use. Frequently used stills in hard water areas may need descaling once a week whereas in a soft water area several weeks may elapse before descaling is necessary. N.B. Heavy scaling will reduce distilled water quality and can shorten the life of the heating element. It is possible to descale the Distinction Water Still without dismantling the glassware by following these instructions in conjunction with Control of Substances Hazardous to Health regulations (COSHH) 1988. 1. Switch off the electricity supply to the still and allow it to cool completely. 2. Turn off the cooling water supply. 3. Open the stop cock on the constant level control and allow the boiler to drain completely. Close the stop cock. 4. Turn on the cooling water supply and allow the boiler to fill to approximately half way to its normal operating level. Turn off the water supply. 5. Into the open funnel of the constant level control, carefully add about 100ml of 10% formic acid or kettle descaler. 20 Issue 2

Warning! Always handle strong acids with great care. Protective clothing, gloves and face masks should be worn during the descaling operation. Remove any acid spills immediately. Turn on the water supply and fill the boiler to the normal operating level. The water will flush the acid into the boiler. The water supply should be turned off when the level in the boiler is slightly below the overflow. 6. Leave the acid in the boiler to dissolve the scale. This may take some time depending on the severity of the build-up. 7. Open the stop cock and allow the boiler to drain: Note: If the acid in the boiler has not been completely neutralised the liquid flowing to drain may be highly acidic. All necessary safety precautions should be observed around the drain and any effluent control procedures followed. 8. Close the stop cock, turn on the water and allow the boiler to fill with cold water. Turn off the water, re-open the stop cock and allow the boiler to drain. Repeat this procedure three times. 9. The Distinction Water Still may now be restarted by referring to the instructions given under Operation in this manual. Note: The stand and outer surfaces of the glassware should be cleaned using a damp cloth and a mild detergent solution. 21 Issue 2

Heater Replacement 1. Isolate the Still from the electricity supply. 2. Clean the heater and boiler if they are heavily scaled, by following the cleaning instructions given in this manual. 3. It will be found easier to replace the heater by working with the boiler on the bench. Therefore: i. Drain the boiler via the stop cock. ii. iii. iv. Remove the end panel. Disconnect the heater cable. Disconnect all water hoses. v. Remove the condenser. vi. vii. viii. Remove the boiler, complete with heater, from the stand. Unscrew the 3 bolts securing the heater and withdraw the heater from the boiler. Remove the aluminium plate and silicone rubber ring from the heater. 4. Fit new heater as described in the assembly para.4. N.B. Examine the silicone ring and replace if not in good condition. 5. Re-assemble the Still by following the assembly instructions. Note: Heater is not covered by the 3 year warranty. It is only guaranteed for up to 1000 hours in use. 6. Ensure the earthed pipe kits are earth bonded to the chassis using the provided earth bond wires. 22 Issue 2

Spares Boiler Condenser Heating Element (D4000) 240V Heating Element (D4000/EURO) 220V Hose Kit Gasket Kit Boiler Thermostat Tube Boiler Thermostat Tube Plastic Screwcap Boiler Thermostat Tube Screwcap O Ring Condenser Thermostat Tube Condenser Thermostat Tube Plastic Screwcap Condenser Thermostat Tube Screwcap O Ring Reservoir Water Level Control Boiler Thermostat Condenser Thermostat Reservoir Water Level Control Pressure Switch On/Off Switch Vapour Tube Sealing O Ring (Upper) Vapour Tube Stabilising O Ring (Lower) Heating Element Silicone O Ring D4000/B WC48/M2 D240H D220H W4000/HK D4000/GK WTT48 I/QC18/11 I/QR18/10 A515414 I/QC18/11 I/QR18/7 WLS WT4 W14TS DPS D4000/SW WB48/01 I/QR38/24 I/QR38/24 Heating Element Plastic Insert 700450 Stop Cock Assembly Heater Terminal Block A4000/RCOCK 700542(S) 23 Issue 2

Fault Finding In the event of operating difficulties with your Distinction Water Still, please consult the following notes. If these fail to identify and remedy the fault you are advised to contact your supplier or the Technical Service Department of Bibby Scientific Ltd. Symptom Cause Remedy Heater not working Water level in boiler is too low heater exposed Water level in boiler is too high e.g. water surging into condenser a. Burnt out heater b. Failed electricity supply c. Thermostat a. Supply of cooling water is insufficient b. Boiler drain stop cock left open a. Flow of cooling water is too high b. Drain is restricted Replace heater. Restore supply. Identify and rectify the cause and reset thermostat. Adjust the supply to approximately 60 l/hr. Close stop cock. Adjust the supply to approximately 60 l/hr. Ensure drain pipe falls freely from Still with no kinks. Adjust the supply to Distillate temperature is too high e.g. >50 C Supply of cooling water is insufficient approximately 60 l/hr. Water in boiler is pumped out a. Tubing from condenser of the boiler to drain distillate outlet to the reservoir is constricted b. Mounting for condenser Remove obstruction. thermostat is blocked c. Supply of cooling water is Adjust the supply to insufficient approximately 60 l/hr. Distillate quality is poor Boiler heavily scaled Clean boiler Output less than 4 l/hr Mains electricity supply below nominal voltage Persistent tripping of the RCD If integrity of the heater is Replace Heater suspect If integrity of the RCD is suspect Replace RCD Ensure tubing falls freely from Still with no kinks. Distillate quality when measured by ph or conductivity is greatly affected by temperature and the presence of absorbed carbon dioxide. 24 Issue 2

25 Issue 2

Notes 26 Issue 2

27 Issue 2