GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

Similar documents
GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

Conductivity Electrode LRG Original Installation Instructions English

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

TRG 5-6x. GESTRA Steam Systems. Installation Instructions

NRG NRG NRG NRG

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

GESTRA Steam Systems NRGS 11-2, NRGS Installation Instructions Level Electrode Types

Level Electrode NRG NRG Original Installation Instructions English

Level Electrode NRG Original Installation Instructions English

SMK 22 SMK SMK SMK 22-82

Temperature Sensor TRG Original Installation Instructions English

Installation & Operating Instructions

MK 45 A. Stainless Steel Design. Installation Instructions Steam Trap MK 45 A

BK 46. Installation Instructions Steam Trap BK 46

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

BK 45 BK 45-U BK 45-LT BK 46

GESTRA. Program for Universal Connections. The Smart Solutions

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

GESTRA. GESTRA Steam Systems NRS For ONE Electrode. English. Installation Instructions Level Switch NRS 1-50

GESTRA Steam Systems OR Installation Instructions Oil & Turbidity Detector OR 52-7

GESTRA. GESTRA Steam Systems TRS English. Installation & Operating Instructions Temperature Switch TRS 5-50

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

GESTRA Steam Systems NRS For TWO Electrodes. English. Installation Instructions Level Switch NRS 1-50

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

VERSAFLOW VORTEX Supplementary instructions

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

TDS Conductivity Probe In-Line conductivity measurement

VIESMANN. Installation instructions VITOMAX 200-HW. for contractors

GESTRA. Product Overview. The optimum components for every application

GESTRA. Product Overview. The optimum components for every application

1592P01. for liquids in piping DN

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Conductivity Monitoring with Manual or Automatic Temp. Compensation LRG... / LRR 1. (Conventional Design)

Mounting and Operating Instructions EB 2231 EN

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Product overview. the optimum components for every application

Water level controller and limiter

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

GESTRA Steam Systems OR English. Installation Instructions Oil & Turbidity Detector OR 52-7

GESTRA Steam Systems OR 52-5 OR English. Installation & Operating Instructions Oil & Turbidity Detector OR 52-5, OR 52-6

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Mechanical seals external, single or double, to DIN EN 12756

Flameproof Manual Call Points

FSW300 Series Flow Switch

BKA-EN Fire Damper. Additional operating instructions according to

ir-range 8G /03.15 Changes reserved.

Hazardous Area Zirconia Oxygen Systems

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

INSTRUCTION MANUAL (ATEX / IECEx)

BSK-RPR Fire Damper. Additional operating instructions according to

LC3000 Level Controller Installation and Maintenance Instructions

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

Model: 1100 Float-Controlled Condensate Trap, PN 25

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

OPERATING MANUAL. ba75825e03 12/2015 LR 925/01 LR 925/01-P LR 925/01(-P) ULTRAPURE WATER CONDUCTIVITY MEASURING CELL

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

GEM TRAP FITTING & MAINTENANCE INSTRUCTIONS

COMPACT FLAME CONTROLLER CFC 2000

COMPACT FLAME CONTROLLER CFC 100

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

SEK-3 Marine Grounding System

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Alarm Switchgear AS1-M

Diaphragm pump 4 - headed

Ultrasonic Level Measurement nivopuls FDU 10 S

Operation Manual. Diaphragm pumps 2-headed. Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep

AND INSTALLATION MANUAL

CORREX MP Anode with external voltage source. Installation & Operation Manual

Adsorption dryer PDAD. (en) Operating instructions g [ ]

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

MANUAL Oil Level Sensor

Manual Isolating Barrier D461R1 (Revision 01)

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Monitored Pneumatic Valves On Series Ported Manifold

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

Certificate of Compliance

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

ATEX instruction for APP / PAH PAHT G 2-90 / PAH Tech

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Indumax CLS50/CLS50D. Operating Instructions. Analog or digital sensors with Memosens protocol For inductive measurement of conductivity in liquids

COMPACT FLAME CONTROLLER CFC 1000

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100

Friwa Compact. Operating instructions EN

Universal Gripper UG 16, UG 18. Operating Instructions

Forced draught gas burner

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Supplementary Installation and Operating Instructions. Category II2G

Survey of electrical equipment installed in hazardous areas on tankers

Transcription:

GESTRA Steam Systems LRG 16-9 EN English Installation Instructions 818867-00 Conductivity Electrode LRG 16-9

Contents Important Notes Page Usage for the intended purpose...4 Safety Notes...4 Danger...4 ATEX (Atmosphère Explosible)...4 Explanatory Notes Scope of supply...5 Description...5 Function...5 Technical Data LRG 16-9...6 Corrosion resistance...6 Sizing...6 Name plate / Marking...6 Dimensions LRG 16-9...7 Dimensions and examples of installation LRG 16-9... 8, 9 Key...9 Installation Installation Notes...10 Attention...10 Mounting conductivity electrode...10 Electrical Connection Connecting conductivity electrode LRG 16-9...11 Attention...11 Wiring diagram for conductivity switch LRS 1-7 (continuous blowdown control)...12 Wiring diagram for conductivity switch LRS 1-7 (water monitoring)...13

Contents - continued - Maintenance Page Danger...14 Cleaning measuring electrode...14 Decommissioning Disposal...14 Annex Note on the Declaration of Conformity / Declaration by the Manufacturer...15 3

Important Notes Usage for the intended purpose Use conductivity electrode LRG 16-9 only in conjunction with conductivity switch LRS 1-7 for measuring the electrical conductivity of electrically conductive liquids. Safety note The equipment must only be installed and commissioned by qualified and competent staff. Retrofitting and maintenance work must only be performed by qualified staff who through adequate training have achieved a recognised level of competence. Danger When loosening the conductivity electrode steam or hot water might escape. This presents the danger of severe scalding. It is therefore essential not to remove the conductivity electrode unless the system pressure is verified to be 0 bar. The conductivity electrode becomes hot during operation. Touching the hot equipment presents the risk of severe burns to hands and arms. All installation, removal and maintenance work must only be performed when the system is cold. ATEX (Atmosphère Explosible) The equipment constitutes a simple item of electrical equipment as defined in DIN EN 50020 section 5.4. According to the European Directive 94/9/EC the equipment must be equipped with approved Zener barriers if used in potentially explosive areas. Applicable in Ex zones 1, 2 (1999/92 EC). The equipment does not bear an Ex marking. The suitability of the Zener barriers is certified in a separate document. 4

Explanatory Notes Scope of supply LRG 16-9 1 Conductivity electrode LRG 16-9 1 Joint ring 21 x 26, form D, DIN 7603, 1.4301, bright annealed 1 Installation manual Description The conductivity electrode LRG 16-9 is designed for use with conductivity switch LRS 1-7 as conductivity monitoring and control system. The electrical conductvity of n Condensate, n Boiler feedwater, n Cooling and cleaning water, n Boiler water is monitored. In steam boiler plants the conductivity monitoring & control system is used as limit switch and continuous blowdown controller. Function The conductivity electrode LRG 16-9 in conjunction with the conductivity switch LRS 1-7 measures the electrical conductivity in conductive liquids. The integrated resistance thermometer enables the conductivity electrode LRG 16-9 to measure the fluid temperature. A short circuit or wire breakage in the conductivity electrode will trigger an error message in the conductivity switch. 5

Technical Data LRG 16-9 Type approval TÜV.WÜL.xx-xxx Service pressure PN 40, max. 32 bar at 238 C Mechanical connection Screwed ½, to ISO 228-1 Cell constant 0.5 cm -1 Materials Screw-in housing: 1.4571, X6CrNiMoTi17-12-2 Measuring electrode: 1.4571, X6CrNiMoTi17-12-2 Electrode rod insulation: PTFE Electrical connection M 12 sensor connector, 5 poles, A coded Protection IP 65 to DIN EN 60529 Ambient temperature at terminal box Max. 70 C Weight Approx. 0.3 kg Corrosion resistance If the equipment is used for the intended purpose, its safety is not impaired by corrosion. Sizing The body is not designed for pulsating loads. The dimensional allowances for corrosion and anticorrosive additives reflect the latest state of the art. Name plate / Marking Equipment designation Manufacturer Connection, protection Fig. 1 6

Technical Data - continued - Dimensions LRG 16-9 1 Space required for servicing = 50 mm ~ 187 2 27 mm A. F. 4 3 43 ½ ISO 228-1 27 18 5 6 ½ ISO 228-1 N 6 0.5 26 Fig. 2 LRG 16-9 7

Dimensions and examples of installation LRG 16-9 7 8 R * = 15 mm Fig. 3 Conductivity electrode LRG 16-9 with on-site socket end for installation in pipes. 70 48 7 60 0 t = 30 9 Fig. 4 Conductivity electrode LRG 16-9 with measuring chamber for installation in pipes. 8

Dimensions and examples of installation - continued - LRG 16-9 - continued - EN 7 DN mm Diameter of flange Thickness of flange 15 95 32 20 105 32 25 115 32 32 150 32 a Fig. 5 Conductivity electrode LRG 16-9 with mounting flange for sandwiching between flanges. Key 1 M 12 Sensor connector, 5 poles A coded 2 Hexagonal part A. F. 27 mm 3 Joint ring 21 x 26 form D to DIN 7603, made from 1.4301, bright annealed 4 Screw-in thread ½ to ISO 228-1 5 Measuring tube 6 Measuring surface 7 Conductivity electrode LRG 16-9 8 Socket end to EN 10241, heavy design, screwed ½ to ISO 228, length 37 mm, provided on site 9 Measuring chamber, ½, PN 10, made from 1.4301 0 Drain plug a Mounting flange PN 40, DIN 2527 with female thread ½ 9

Installation Installation Notes The conductivity electrode is designed for installation in pipes. The conductivity electrode is installed in a socket end, a measuring chamber or a mounting flange. Measuring chamber and mounting flange available as optional extra. When installing the conductivity electrode please consider a min. space of 50 mm required for servicing and removing the conductivity electrode. Attention n Make sure that the sealing surface of the screwed connection is accurately machined. n Use only the supplied ring joint 21 x 26, form D, DIN 7603, made from 1.4301, bright annealed! n Do not insulate screw-in thread with hemp or PTFE tape. n Install electrode horizontally or with a vertical inclination. The measuring surface must be permanently submerged. n Observe the specified tightening torque. n Leave a space of approx. 15 mm between the lower end of the measuring tube and the wall of the pipe. n Do not cut the measuring electrode and the measuring tube! Mounting conductivity electrode 1. Check sealing surface of screwed connection (see Fig. 2). If necessary, re-finish. 2. Put joint ring 3 supplied with the electrode onto the seating surface of the conductivity electrode. 3. Apply a light smear of silicone grease to the electrode thread. 4. Screw in conductivity electrode and fasten it with an open-end spanner 27 mm A. F. The torque required for tightening when cold is 110 Nm. 10

Electrical Connection Connecting conductivity electrode LRG 16-9 The conductivity electrode LRG 16-9 and the conductivity switch LRS 1-7 are equipped with M 12 sensor connectors with 5 poles and A coded; for connection see Fig. 6 and Fig. 7. For connecting the equipment control cable assemblies (with plug and connector) of various lengths are available as addon equipment. Note that the recommended control cable is not UV-resistant and, if installed outdoors, must be protected by a UV-resistant plastic tube or cable duct. If the above-mentioned control cable assembly is not used, a screened five-core control cable, e. g. Ölflex 110 CH, manufactured by Lapp, 5 x 0.5 mm 2 or LiYCY 5 x 0.5 must be used for wiring. Max. cable length between conductivity electrode and switch: 30 m, with conductivites from 0.5 to 10 μs/cm: max. 10 m. Attention n If the above-mentioned control cable assembly is not used, the connecting line must be provided with a connector and a screened jack according to the wiring diagram Fig. 6 and Fig. 7. n Connect screen only in the jack (on electrode). 11

Electrical Connection - continued - Wiring diagram for conductivity switch LRS 1-7 (continuous blowdown control) LRS 1-7 g P5 P4 P7A P7B P6 f P14 P3 P2 P1 0 h c Operation OPEN CLOSED i d e Contacts shown at Power OFF / limit exceeded condition Fig. 6 0 M 12 sensor jack, 5 poles, A coded c M 12 sensor connector, 5 poles, A coded (conductivity electrode) d Conductivity electrode LRG 16-9 e Conductivity electrode ERL 16, LRG 16-4 (without Pt 100) f Current output 4-20 ma, load max. 500 Ω (option) g Limit contact MAX h Disconnector i Continuous blowdown valve (actuator) BAE L2 must remain live after the burner (stand-by operation) is shut down until the continuous blowdown valve is motored to close. L1 and L2 must be connected to an external conductor of the same phase. 12

Electrical Connection - continued - Wiring diagram for conductivity switch LRS 1-7 (water monitoring) LRS 1-7 g P5 P4 P7A P7B P6 f P14 P3 P2 P1 h 0 c j Valve OPEN: Fluid is flowing through Valve CLOSED: Fluid is discharged or retained Safety position: Spring to close. d e Contacts shown at Power OFF / limit exceeded condition Fig. 7 0 M 12 sensor jack, 5 poles, A coded c M 12 sensor connector, 5 poles, A coded (conductivity electrode) d Conductivity electrode LRG 16-9 e Conductivity electrode ERL 16, LRG 16-4 (without Pt 100) f Current output 4-20 ma, load max. 500 Ω (option) g Limit contact MAX h Disconnector j Electric or pneumatic three-way valve 13

Maintenance Danger When loosening the conductivity electrode steam or hot water might escape. This presents the danger of severe scalding. It is therefore essential not to remove the conductivity electrode unless the system pressure is verified to be 0 bar. The conductivity electrode becomes hot during operation. Touching the hot equipment presents the risk of severe burns to hands and arms. All installation, removal and maintenance work must only be performed when the system is cold. Risk of severe burns and scalds to the whole body! Cleaning measuring electrode The conductivity electrode may only be installed and removed by qualified personnel. Observe note in chapter Installation on page 10. Before cleaning the measuring electrode decommission and remove the conductivity electrode. Clean the conductivity electrode. n Wipe off non-adhesive deposits with a grease-free cloth. n To remove adhesive deposits use emery cloth (medium grain). Decommissioning Disposal Dismantle the conductivity electrode and separate the waste materials, using the material specification as a reference. Electronic component parts such as the circuit board must be disposed of separately! For the disposal of the conductivity electrode observe the pertinent legal regulations concerning waste disposal. If faults occur that are not listed above or cannot be corrected, please contact our service centre or authorized agency in your country. 14

Annex Note on the Declaration of Conformity / Declaration by the Manufacturer For details on the conformity of our equipment according to the European Directives see our Declaration of Conformity or our Declaration of Manufacturer. The current Declaration of Conformity is available in the Internet under www.gestra./de/documents or can be requested from us. 15

GESTRA Agencies all over the world: www.gestra.de España GESTRA ESPAÑOLA S.A. Luis Cabrera, 86-88 E-28002 Madrid Tel. 0034 91 / 5 15 20 32 Fax 0034 91 / 4 13 67 47; 5 15 20 36 E-mail: aromero@flowserve.com Great Britain Flowserve GB Limited Abex Road Newbury, Berkshire RG14 5EY Tel. 0044 16 35 / 46 99 90 Fax 0044 16 35 / 3 60 34 E-mail: gestraukinfo@flowserve.com Polska GESTRA Polonia Spolka z.o.o. Ul. Schuberta 104 PL - 80-172 Gdansk Tel. 0048 58 / 3 06 10-02 0048 58 / 3 06 10-10 Fax 0048 58 / 3 06 33 00 E-mail: gestra@gestra.pl Portugal Flowserve Portuguesa, Lda. Av. Dr. Antunes Guimarães, 1159 Porto 4100-082 Tel. 00351 22 / 6 19 87 70 Fax 00351 22 / 6 10 75 75 E-mail: jtavares@flowserve.com Italia Flowserve S.p.A. Flow Control Division Via Prealpi, 30 l-20032 Cormano (MI) Tel. 0039 02 / 66 32 51 Fax 0039 02 / 66 32 55 60 E-mail: infoitaly@flowserve.com USA Flowserve GESTRA U.S. 2341 Ampere Drive Louisville, KY 40299 Tel. 001 502 / 267-2205 Fax 001 502 / 266-5397 E-mail: FCD-Gestra-USA@flowserve.com GESTRA AG P. O. Box 10 54 60, D-28054 Bremen Münchener Str. 77, D-28215 Bremen Telephone 0049 (0) 421 / 35 03-0 Fax 0049 (0) 421 / 35 03-393 E-Mail gestra.ag@flowserve.com Internet www.gestra.de 818867-00/1108cm 2007 GESTRA AG Bremen Printed in Germany 16