Radiation Safety issues for the PF-AR in KEK

Similar documents
Radiation Safety issues for the PF-AR in KEK

Injection with front ends open at the ESRF

Minimizing radiation and beam losses at the ESRF

SYNCHROTRON RADIATION ABSORPTION AND VACUUM ISSUES IN THE IR*

Performance Requirements for Monitoring Pulsed, Mixed Radiation Fields Around High-Energy Accelerators

NON-DESTRUCTIVE 2-D BEAM PROFILE MONITOR USING GAS SHEET IN J-PARC LINAC -overview & hardware construction-

Vacuum Quality Assurance in Practice

Beam Loss Position Monitoring with Optical Fibres at DELTA

VACUUM PERFORMANCE IN THE MOST RECENT THIRD GENERATION SYNCHROTRON LIGHT SOURCES

Performance test of a helium refrigerator for the cryogenic hydrogen system in J-PARC

BESSY ventilation concept

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

Change History Log. Rev Revision Sections Affected Description of Change /22/08 All Initial Version

Development of a new X-ray source system using ultraviolet laser for medical treatment

Goals Understand Responsibilities, Awareness, Communication. Beamline phases Design, Implementation, Commissioning, Operation

Status of the PRad Experiment (E )

Radiation Control and Monitoring System on the HTTR

ARCON/RAMSES: Current Status and Operational Risk

IBL 637 Cesium-137γ-ray machine 2016

Portable Survey Instruments NISP-RP-01

Experimental Particle Physics PHYS6011 Joel Goldstein, RAL

Monitoring of Radiation Exposure Adjacent to a Linear Accelerator Treatment Bunker with a Highlight Window

Development of high sensitivity radon detectors

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

The use of NEG pumps and coatings in large vacuum systems: experience and limitations

A CONCEPT FOR CANCELLING THE LEAKAGE FIELD INSIDE THE STORED BEAM CHAMBER OF A SEPTUM MAGNET*

Heavy Ion Beam Characteristics of ICCHIBAN 7 and 8 Experiments and Brief Summary of the ICCHIBAN Experiments

Approved by Principal Investigator: Date: Approved by Laser Safety Officer: Date:

Ionisation Chambers Containing Boron as Neutron Detectors in Mixed Radiation Fields

Radiation Emitting Devices Research X-ray Safety Program

Pyroelectric crystal based neutron source and neutron detector

Safety introduction for users

Radiation Safety Systems

Radiation Safety for AREAL Phase 1

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

FRIB MACHINE PROTECTION SYSTEM DESIGN AND VALIDATION STUDIES*

Radiation Safety Systems

IntegraTorr Sputtered Non-Evaporable Getter. We support your innovation

Competency: Critically evaluate the function of the ionisation chamber in the Linear Accelerator and its importance for correct treatment delivery

Machine-Detector Interface

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

Extreme High Count Rate Performance with a Silicon Drift Detector and ASIC Electronics

Vacuum requirements and Beamline interface at the VUV-FEL User Facility

Identify the following features and specifications for the ESP1

Status Report about the TPC Detector and Module at CEPC

Battery-operated, hand-held alarm and measuring instruments for radiation protection

LCLS DIRECTORATE Experimental Facilities Division

MD456: Monitoring of abort gap population with diamond particle detectors at the BGI in IP 4

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

HiRadMat facility at the CERN SPS

LCLS Instruments. Jerry Hastings June 20, 2008 LCLS

Aging Analysis of Micromegas Detectors for ATLAS New Small Wheel

The LHCb Outer Tracker: Production & Ageing studies

HEALTH AND SAFETY MANUAL

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

DEVELOPMENT OF LARGE AREA PLASTIC SCINTILLATION DETECTOR FOR RADIOACTIVE CONTAMINATION MONITOR

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

RAMSES: THE LHC RADIATION MONITORING SYSTEM FOR THE ENVIRONMENT AND SAFETY

25 TEXAS ADMINISTRATIVE CODE Radiation Safety Requirements for Analytical and Other Industrial Radiation Machines

Maximize safety and productivity. Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions

Fan speed controller Type Saginomiya XGE

Doc. No. SP R0. CXI Reference Laser. Prepared by: Jean-Charles Castagna Signature Date Design Engineer

A Small Refrigerator System for Cooling Thermal Shield of a Large Superconducting Magnet

Abstract. 1 NSRRC, 101 Hsin-Ann Road, Hsinchu 300, Taiwan 2 Dept. of Biomedical Engineering & Environmental Sciences, NTHU, Hsinchu 300, Taiwan

Engineered and Administrative Safety Systems for the Control of Prompt Radiation Hazards at Accelerator Facilities

dewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants.

Micromegas detectors for the upgrade of the ATLAS Muon Spectrometer

Market Survey. Technical Description Supply of Helium Leak Detectors

Replacement of the Criticality Accident Alarm System in the Tokai Reprocessing Plant

The development of a plastic scintillator for radiotherapy dosimetry

Table of Contents. Check the LCLS Project website to verify 2 of 12 that this is the correct version prior to use.

WG Container & Cargo X-Ray Scanning Portal

Gaseous detectors. 1

Electronic Personal Dosemeter

Diagnosing Troubles in Refrigeration Units with Screw Compressors

The system can be easily relocated by a standard container truck., and re-commissioned by trained engineers typically within a 72-hour period

THE REPUBLIC OF UGANDA ATOMIC ENERGY ACT, 2008 SCHEDULE 1 FORM 2A

Applying Layer of Protection Analysis (LOPA) to Accelerator Safety Systems Design. Feng Tao

ALPHA Radiation Safety Manual

WG Entire Truck & Cargo X-Ray Scanning Portal

Controls Surface mounted pushbuttons Suitable for gloved use. Buttons Side - On/Off Front Menu Scroll Pin Hole Setup access

arxiv: v1 [physics.ins-det] 27 Jan 2012

Emission Monitoring System

Minnesota Rules, Chapter 4732 X-Ray Revision

Sensing the World. When you have finished this lecture you should be able to:

PROFILER Family IC PROFILER, IC PROFILER - MR & SRS PROFILER. Your Most Valuable QA and Dosimetry Tools

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

Energy and Angular Responses of the Criticality Accident Alarm System Using Current-mode-operated Scintillation Detector

Analytical X-Ray Safety Program

Physics Requirements for the CXI Detector Stage

Maximizing safety and productivity. Nuclear Power Radiation Detection and Monitoring Solutions

Dust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12

Document Preparation Profile (DPP)

Special Aspects in Designing High - Frequency Betatron

Personal Radiation Alarm Dosimeter LK Operating Instruction Manual. Contents

Fireye FLAME SCANNERS

THERMAL DIAGNOSIS OF MV SWITCHBOARDS: A COST-EFFECTIVE, DEPENDABLE SOLUTION BASED ON AN OPTICAL SENSOR

A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY

PART V: WORKING WITH LASERS

Transcription:

Radiation Safety issues for the PF-AR in KEK H. Nakamura, S. Ban, K. Iijima,Y. Namito and K. Takahashi High Energy Accelerator Research Organization(KEK), 1-1 Oho, Tsukuba-shi, Ibaraki-ken, 305-0801, Japan Abstract The ambient dose rates in the experimental halls of the Photon Factory Advanced Ring (PF-AR) are measured with the area monitors. The dose rates are usually background level. However, when the beam lifetime decreased suddenly, the dose rates increase. This phenomenon is considered bremsstrahlung due to dust trapping near the duct. We measured the dose rate during the phenomenon and made radiation protection. 1. Introduction 1.1. Present status of the electron accelerators in KEK There are three electron rings, a positron ring and an electron-positron linac in High Energy Accelerator Research Organization (KEK). Figure 1 shows the location of these accelerators. Two of the electron rings are the Photon Factory (PF) and the Photon Factory advanced ring (PF-AR) used for synchrotron radiation experiments. One of the electron rings (HER) and the positron ring (LER) are used for electron-positron collision experiments (KEKB). The electron-positron linac injects four different beams into the four rings. The recent improvement in KEK is a simultaneous Top-UP injection for the 3 rings (HER, LER, PF). The simultaneous injection has started since 24 th April 2009. The linac provides simultaneously 8 GeV electrons to HER, 3.5 GeV positrons LER, and 2.5 GeV electrons to PF by using the pulse to pulse switching injection system [1]. Figure 2 shows the 3 rings keep the constant current except during PF-AR injection. KEKB LER&HER PF-AR PF 1.5 km LINAC 1.0 km Fig.1 - Plan of electron accelerators in KEK. LINAC locates southwest part in KEK. PF ring locates west of LINAC end. PF-AR ring locates north of LINAC. KEKB 2 rings locate north part of KEK. RADSYNCH'09 - Page 71

Fig.2 - PF, LER and HER keep each constant current except during PF-AR injection. 1.2. Outline of the PF-AR The PF-AR is a 6.5 GeV synchrotron radiation source, which operated with single bunch for pulsed hard X- rays. The ring is injected at 3.0 GeV, after that the beam is accelerated to 6.5 GeV and stored initially at 60 ma. The ring has 8 beam lines and 6 insertion devices. Table 1 shows main parameters of the PF-AR[2]. Beam energy Circumference Injection energy 6.5 GeV 377 m 3.0 GeV Typical num. of bunches 1 Initial stored current Beam lifetime (at init.cur.) 60 ma 20 hours Num. of insertion devices 6 Table 1 - Main parameters of the PF-AR. 2. Management of radiation safety in the PF-AR The experimental halls of the PF-AR are radiation controlled areas. The ambient dose rate in the halls should be controlled less than 20 µsv/h. The dose rate is measured by the area monitors named ORG monitors. Figure 3 shows the appearance of an ORG monitor. The monitor consists of a 10-liter ionization chamber for gamma detection and a 1-inch BF3 proportional counter for neutron detection. The monitors give an alarm when the dose rate is over 20 µsv/h. Figure 4 shows the locations of the monitors in the experimental halls of the PF-AR. The users of the PF-AR should be the radiation workers of KEK. The limit of annual personal effective dose is 20 msv for the male radiation workers and 6 msv for the female radiation workers. Target of the personal effective dose is less than 7 msv for the male workers and less than 2 msv for the female workers. In Fact, most of the workers are not exposed significantly. RADSYNCH'09 - Page 72

Fig.3 - An ORG monitor consists of a 10-liter ionization chamber for gamma detection and a 1-inch BF3 proportional counter for neutron detection. ORG0508 ORG0507 ORG0503 ORG0510 ORG0502 ORG0506 ORG0509 ORG0501 Fig.4 - The locations of the ORG monitors in the experimental halls of the PF-AR. 3. Measurements and studies Usual ambient dose rate in the experimental halls is background level. However, the dose rate increases when the beam lifetime of the PF-AR decreases suddenly. Figure 5 shows a typical example of the incident occurred at the NW12 beam line in the North West experimental hall. When the beam lifetime decreased from 500 minutes to 100 minutes, the gamma dose rate at ORG0509 monitor increased from 0.1 µsv/h to 1.6 µsv/h and the neutron dose rate increased from 0 µsv/h to 0.2 µsv/h. At that time, ORG0509 monitor was located at the wall of the experimental hall, therefore, there was little information about the dose rate around the beam line. When another similar incident happened, we measured the dose rate around the NW12 with survey meters. Figure 6 shows the dose rate around the NW12. The maximum dose rate at the surface of the NW12 hutch was 230 µsv/h. RADSYNCH'09 - Page 73

The measurements showed the following conditions for the incident. Changing narrowly the gap of NW14 insertion device which located upper stream of NW12 often triggered the incident. The vacuum level was worse. The beam lifetime decreased. The dose rate around the NW12 increased, however not increased around other beam lines. The dose rate returned to background level when the main beam shutter (MBS) in the beam line was closed. Since the beam orbit of the ring was newly arranged for installing new beam line NW14, it was suspected for the cause of the incidents. The operation with the old beam orbit was tested. However it did not change the situation. Measurement of residual radiation from the beam duct of the ring showed the duct near the steering magnet of NW12 was activated. This phenomenon is considered bremsstrahlung due to dust trapping near the duct[3]. Checking the log of the monitors showed similar incidents were occurred before. Current Lifetime 500min 100min 1.8 1.6 1.4 Dose rate(μsv/h) 1.2 1 0.8 0.6 0.4 0.2 0 10:00 11:00 12:00 13:00 14:00 15:00 Tim e N eutron G am m a 4. Measures for safety The followings were first things what we did for the safety in the experimental hall. We set up the area where people were not allowed to enter because of high dose rate. We changed temporarily the alarm level of the ORG monitors in the experimental halls from 20 µsv/h to 1 µsv/h for detecting the incidents occurred far from the monitors. Next, lead blocks were installed in the optic hutch of the NW12. An ionization chamber for interlock was installed out of the optic hutch. It closes the MBS when the dose rate exceeds 5µSv/h and continues for 3 minutes. Finally, ORG0509 monitor was moved to near the optic hutch of the NW12 for detecting radiation effectively. 5. Results Fig.5 - An example of the sudden beam lifetime decreasing and increase of the dose rate at the ORG0509 monitor in the experimental hall. Nobody in the PF-AR was exposed to significant radiation. The frequency of the incident around NW12 decreased. Other beam line (ex. NE3) also had the incident, but not so often. One of sources of the dust is RADSYNCH'09 - Page 74

considered distributed ion pump (DIP)[4].The frequency of the incident has decreased since DIP-OFF operation started. ORG0509 Unit: μsv/h 6 12 230 14 Date: 10/5/2005 13:20 Detector: Ion chamber Operation: stored current 52.5mA lifetime 186minutes Fig.6 - The dose rate around the beam line NW12 during the beam lifetime decreasing. References [1] N. Iida, et al., Pulse-to-Pulse Switching Injection to Three Rings of Different Energies from a Single Electron LINAC at KEK, PAC09, Vancouver, Canada, May 2009, WE6PFP110. [2] Y. Kobayashi, et al, Present Status of PF-Ring and PF-AR in KEK, EPAC08,Genova, Italy, June 2008, 2064-2066(2008) [3] H. Saeki, T. Momose, H. Ishimaru, Observations of dust trapping phenomena in the TRISTAN accumulation ring and a study of dust removal in beam chamber, Rev. Sci. Instrum., 62, 874-885 (1991). [4] Y. Tanimoto, et al., Improvement of beam lifetime and vacuum system of the PF-AR, Vacuum (2009), doi:10.1016/j.vacuum.2009.06.044 RADSYNCH'09 - Page 75