Ensuring the Effectiveness of Clinical Alarm Systems

Similar documents
Alarm Management. Objectives

Alarm Fatigue in the ICU. Lynn Maguire MS, RN, PMC, NE-BC

You finally make it home after a long shift, shower,

NFPA 99 Risk Assessment

URGENT: MEDICAL DEVICE CORRECTION Plum 360 Infusion System List Number: 30010

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

GE Healthcare. Dash Variable-Acuity Monitoring

2011 National Clinical Alarms Survey: Perceptions, Issues, Improvements and Priorities

Alarm Management at Boston Medical Center A Roadmap to Safe Silence

Focus on Respiratory Care & Sleep Medicine Irvine, CA. Alarm Management. September 14-15, 2018

June 17, Skanray Technologies Pvt Ltd. c/o Ms. Yolanda Smith Regulatory Consultant Smith Associates 1468 Harwell Avenue Crofton, Maryland 21114

Why Clinical Alarms are a TOP TEN Hazard

Hospital Ward Alarm Fatigue Reduction Through Integrated Medical Device Instruction and Hospital System Policy

GE Healthcare Healthcare Systems 9900 Innovation Drive Wauwatosa, WI USA

Sound the Alarm! Strategies for Alarm Management in the Rush NICU. October 21 st, 2015

The information in this document is subject to change without notice.

(Place Logo from Lab here)

BeneVision Central Monitoring System. Quick Reference Guide

General Skills. yes. Device controls, buttons, indicators, and connectors

Makassed Philanthropic Islamic Association

Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1

Preventing ECMO Patient Harm While Using Remote Monitoring: A Case Report. Emily Thunstrom

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

Vital Signs Monitor 300 Series

Impact Of Clinical Alarms On Patient Safety. American College of Clinical Engineering Healthcare Technology Foundation (AHTF)

SOFTWARE VERSION 8.5 FAQs

HeartMate II LVAS The Pump

Cl inician Training Packet

TOURNIQUETS ORDER INFORMATION 4ELECTRIC TOURNIQUETS. electric digital pressure display battery back-up system

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

URGENT - Field Safety Notice Medical Device Correction

OPERATOR S MANUAL. Patient Monitor M20. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain

OPERATOR S MANUAL. For YM1000 Vital Signs Monitor. EU Representative TECNOMED 2000 S.L. Valencia, Madrid Spain

P/N: Release Date: January 2012 Copyright EDAN INSTRUMENTS, INC All rights reserved.

Clinical Alarm Effectiveness: Recognizing & Mitigating Risk to Patient Care

13799 Commerce Parkway Richmond, British Columbia V6V 2N9 Canada Benjamin Barker, Senior Manager Accreditations

TG FIRE DRILLS. Office of the Fire Marshal and Emergency Management

Environmental Planning and Assessment Amendment (Smoke Alarms) Regulation 2006

N-600. Pulse Oximeter Operator s Manual

Puritan Bennett 980 Ventilator System Planning for Training Checklist

Control Panel User Guide (TO BE RETAINED BY THE USER)

M9500 Patient Monitor User s Manual

Control Panel User Guide

PM-9000 Express Portable Patient Monitor

signal extraction pulse oximeters OPERATOR S MANUAL

V6 Vital Signs Monitor User s Manual

Model 7500 Model 7500

Prepared in collaboration with Community Medical Centers (CMC) and University California San Francisco (UCSF)

Vital Signs Monitor 300 Series

Model 900. Pulse Oximeter User s Manual

signal extraction pulse oximeters OPERATOR S MANUAL

Vital Signs Monitor 300 Series

Apnoea Alarm. Information for parents and carers. MR 10 Respiration Monitor - Apnoea Alarm. Please read this leaflet carefully.

User Guide. Cardell Insight Veterinary Monitor. For Models: 8014 Blood Pressure Blood Pressure, Pulse Oximetry

The Joint Commission's National Patient Safety Goal on Alarm Management: How Do We Get Started?

Policy and Procedure. Emergency Notification and Response Policy. Policy Statement

N-600. Pulse Oximeter Home Use Guide

bibag System User s Guide

Manufacturer s Responsibility Only under the following circumstances will manufacturer be responsible for the safety, reliability and performance of t

Alarms That Deserve Attention. Mike Rayo 3/29/2016

Practical Application of a Failure Modes and Effects Analysis (FMEA) in the Healthcare Setting

Powerohm Resistors Digital HRG System

Fire Safety Policy & Fire Safety Management System Version October 2013 Emergency Evacuation Procedures

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

ANGELUS (Ver 2.03) Patient Monitoring System

Watchguard WGAP864 User Manual

Veterinary Portable Multi-parameter Patient Monitor. Operation Manual

13799 Commerce Parkway Richmond, British Columbia V6V 2N9 Canada Benjamin Barker, Manager Accreditations

Quick Reference Guide *

B40/B20 Patient Monitor User's Guide. English E (Paper) 21 November General Electric Company. All rights reserved.

System and Components Installation Manual

IQvitals Zone TM. For Models: User Guide

EC 5.10 FIRE PREVENTION MANAGEMENT

N-595. Pulse Oximeter Service Manual

ELECTRICAL SAFETY IN HEALTHCARE FACITILIES

The Contra Costa EMS System and Fire Station Closures: Impact and Mitigation

Section. 3: CADD Pump. Updated: June 20, Section Author(s): sstafford & jhval

AUDIBLE ALARMS AND WORKPLACE NOISE IN NURSING UNITS: AN ENVIRONMENTAL FACTORS CASE STUDY

Vitalmax 4000 CL Product Specifications

SurgiVet V6004 NIBP Monitor Operation Manual

27th Annual AHCA Seminar

OPERATOR S MANUAL. NPB-4000/4000C Patient Monitor

GBMC Safety, Security and Emergency Preparedness

HUG.ai 1/24/06 9:33:34 AM HUG.ai 1/24/06 9:33:34 AM C M Y CM MY CY CMY K

Reference Case: Avera Heart Hospital Data-Driven Approach Helps Hospital Build Effective Clinical Alarm Management Program

PULSE OXIMETER PACKAGE

Professional Design Project

FIRE ALARMS EMERGENCY LIGHTS NURSE CALL ACCESS CONTROL GK FIRE & SECURITY LTD, UNIT 1 GREBE RD, PRIORSWOOD IND EST, TAUNTON, TA2 8PZ

To navigate through the CBL, use the scroll bar to the right

Applicable To Employees of the Gundersen St. Joseph s Hospital laboratories and Gundersen Tri-County Hospital laboratories.

Hospital Codes, Safety, Exposure Control, Emergency Plans Handout

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Operator s Manual. Avant Pulse Oximeter and Noninvasive Blood Pressure (NIBP) Monitor English

NFPA 99 for Facility Managers

T1 BEDSIDE MONITOR GUIDELINE

Track the truth. Give no false assurance. Do no harm. Nellcor SpO 2. Module for use with Philips IntelliVue * Patient Monitors

Quick start guide. BiPAP AVAPS

MATRIX TO DETERMINE YOUR PRESENT POSITION IN MEETING N.F.P.A. 1720

EMERGENCY PROCEDURES

Transcription:

Ensuring the Effectiveness of Clinical Alarm Systems Requirements: Ensure that critical alarms used in the clinical environment are tested on an ongoing, scheduled basis and they are sufficiently audible to staff with respect to distance and competing noise in the unit. Definition: A critical clinical alarm is any audible or visual indication from a system or device, that when activated, may result in the injury or death of a patient unless immediate clinical intervention results. Process: A four step process is used to ensure the effectiveness of critical alarm systems, as defined below: Step 1: Determine which audible and visual indicators are included in the list of critical clinical alarms. The determination of whether an audible or visual indication is considered a critical clinical alarm is evaluated by using a risk assessment process that considers the severity and probability of an inappropriate staff response to an alarm. A numerical evaluation is assessed and documented using the following criteria: Severity Rating (likely result if the alarm is not attended to by staff on a timely basis) Probability of an inappropriate staff response after the alarm has activated: 5 Death 4 Serious injury, likely to be permanent 3 Major injury, possible long-term effects 2 Minor injury, not likely to have long-term effects 1 No injury 5 Almost certain to occur 4 Occurrence is probable 3 Possible 2 Very unlikely to occur 1 Will not occur The assessment score (AS) is calculated by multiplying the Severity Rating (SR) by the Probability (P): AS = SR X P. Alarms that result from systems or equipment with scores greater than or equal to 9 will be included in the critical alarm list. Refer to Table 1 for the summary of risk assessment scores. Step 2: Clearly define testing responsibilities. A description of the responsibilities for testing the critical clinical alarms is defined in Table 2. Step 3: Determine critical alarm audibility. Although there are many methods to determine the audibility of critical alarms by clinical staff, the use of a self-assessment form (refer to Table 3) is recommended. Step 4: Verify that clinical staff respond as expected to critical clinical alarms. Document clinical staff response through the use of an alarm evaluation simulation. Refer to Figure 1 for a sample test form.

Step 1 - Critical Clinical Alarm Risk Assessment Device Description Severity Rating (SR) Probability of Inappropriate Response (P) Total Score Inclusion as Critical Clinical Alarm? Ventilator 5 2 10 Yes Blood Warmer 4 2 8 No Infant Warmer 3 3 9 Yes Anesthesia Unit 5 1 5 No Apnea Monitor 5 2 10 Yes Bipap Unit 2 3 6 No Chair Occupancy Alarm 4 4 16 Yes Defibrillator 5 1 5 No Electrosurgical Unit 3 2 6 No Feeding Pump 2 3 6 No Hypo/Hyperthermia Unit 3 3 9 Yes Infusion Pump 4 3 12 Yes Injector 2 2 4 No Intra-aortic Balloon Pump 5 2 10 Yes Bedside Physiological Monitor 5 3 15 Yes Heart Rate Monitor 5 3 15 Yes NIBP Unit 2 3 6 No Pulse Oximeter 3 3 9 Yes SCD 2 3 6 No Tourniquet 3 2 6 No Bathroom Emergency Call 4 3 12 Yes Code Blue Call 5 2 10 Yes Infant Abduction Alarm 3 3 9 Yes Nurse Call 3 4 12 Yes Medical Gas Alarm 3 3 9 Yes Line Isolation Monitor 2 3 6 No Table 1

Step 2 - Critical Clinical Alarm Test Responsibility Matrix Device Description Clinical Engineering Nursing Ventilator Infant Warmer PM tests Monitor Apnea Monitor Scheduled Periodic Chair Occupancy Alarm Scheduled Periodic Hypo/Hyperthermia Unit Scheduled Periodic Infusion Pump Intra-Aortic Balloon Pump PM tests Monitor Bedside Physiological Monitor PM tests monitor Heart Rate Monitor PM tests monitor Pulse Oximeter PM tests monitor Bathroom Emergency Call N/A Respond Code Blue Call N/A Respond Infant Abduction Alarm N/A Respond Nurse Call N/A Respond Medical Gas Alarm N/A Respond Ancillary Clinical Plant Operations Security Alarm setup N/A N/A limits Alarm setup N/A N/A limits Alarm setup N/A N/A limits N/A Scheduled alarm tests N/A N/A Scheduled N/A alarm tests N/A N/A Scheduled alarm test N/A Scheduled N/A PM checks N/A Scheduled N/A PM tests Table 2

Step 3: Determine Critical Clinical Alarm Audibility Critical Clinical Alarm Nursing Self-Assessment Form Device Description Ventilator Is the Alarm Audible? Able to Discern the Alarm? Can Alarm be Silenced? Can Alarm Volume be Adjusted or Reset? Has Staff Training been Provided Infant Warmer Apnea Monitor Chair Occupancy Alarm Hypo/Hyperthermia Unit Infusion Pump Intra-Aortic Balloon Pump Bedside Physiological Monitor Heart Rate Monitor Pulse Oximeter Bathroom Emergency Call Code Blue Call Infant Abduction Alarm Nurse Call Medical Gas Alarm Table 3

Step 4: Evaluate Clinical Staff Alarm Response Date of Test: Time of Test: Department or Unit: Room: Room Type: (example: isolation, patient, multi-bay, etc.) Equipment or Device Tested: Was the alarm initiated with a simulator? Y N If no, how was the alarm initiated? What type of alarm was initiated? Is this alarm considered critical to patient care? Y N Did the alarm activate as expected? Y N Was the alarm heard? Y N If the alarm was heard, where was the individual when he/ she heard it? If the alarm was not heard, indicate the reason: How long did it take for someone to respond to the alarm? How many people responded to the alarm? What other noises were in the environment, competing with the alarm? What changes, if any, are needed to improve the effectiveness of critical clinical alarms? Signature of Department Representative: Figure 1