Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

Similar documents
CONTENTS DESCRIPTION UNPACKING DIMENSIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions Exhaust Fan With Light

CONTENTS WIRING DIAGRAM

HUMIDITY SENSING BATH FAN

VENTILATION FAN / LED LIGHT

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

e Bath Fan with Light User s Guide

breeze easytm model # F100-1W

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

VENTILATION FAN WITH LIGHT AND HEATER

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

INSTALLATION MANUAL AND USER GUIDE

e Heater/Exhaust Fan/Light User s Guide

Please Read and Save These Instructions Safety Information

INSTALLATION MANUAL AND USER GUIDE

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

VENTILATION FAN WITH BLUETOOTH SPEAKER

READ AND SAVE THESE INSTRUCTIONS

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH

Bathroom Exhaust Fan/Fluorescent Light Combination

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

Bathroom Exhaust Fan/Fluorescent Light Combination

READ AND SAVE THESE INSTRUCTIONS

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

Bathroom Exhaust Fan

Use, Care, and Installation Guide

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

UNDER CABINET RANGE HOOD

High Power Range Hood

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

Integrated Ventilation System

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

Pro Ventilation Hood Liners

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Installation Instructions Preference Wall Mount Range Hood

CLEANING & MAINTENANCE For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild d

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Installation Instructions

Cooktop Chimney Ventilation Hoods

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Insulated Ventilators. Operating Instructions & Parts Manual

Installation. Professional Built-in Hoods

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

Installation Instructions Remote Blowers

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

Imperial. Read Before Starting Installation!

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

Use and Care & Installation Guide

Use, Care, and Installation Guide

Operating and Installation Instructions

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

RANGE HOOD. Model SEH5636G. FELIX STORCH, INC. 770 Garrison Avenue Bronx, New York

APPUZO RANGE HOOD INSTALLATION

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

Easy installation in both new construction and retrofit

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

Ceiling Fan Installation Instructions

User s Manual HI30SS HI36SS HI42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Owner and Maintenance Guide Models Equipped with K250 Blower

Imperial. Cal. Products, Inc. Installation Instructions & Warranty Information. 425 Apollo Street Brea, CA

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

Model KER222. BEST BY BROAN P.O. Box 140 Hartford, WI ENGLISH...3 FRANÇAIS...12 ESPAÑOL

Solatube Daylight Dimmer Installation Instructions


READ AND SAVE THESE INSTRUCTIONS

Imperial Cal Products, Inc.

Humidity and Thermostat control box for Attic Fan

PLEASE READ AND SAVE THESE INSTRUCTIONS

Transcription:

Ventilating Fan FV-05VFL FV-08VFL FV-VFL READ AND SAVE THESE INSTRUCTIONS. Please read these instructions carefully before attempting to install, operate or service the Panasonic Ventilating Fan. Failure to comply with instructions could result in personal injury and/or property damage. Please retain this booklet for future reference. Table of Contents Supplied Accessories Description Dimensions Specifications Unpacking General Safety Information Installation I ( Joist Mounting- I ) Installation II ( Joist Mounting- II ) Installation III ( I-Joist Mounting ) Installation IV ( Between Joist Mounting ) Installation V ( Wooden Header ) Installation VI ( In Existing Construction ) Maintenance Practical Guide to Installation Product Service 3-5 6-8 8-9 0 0- - 3-

FV-05VFL FV-08VFL FV-VFL Part name Appearance Quantity Part name Appearance Quantity Grille Machine screw MX8 bracket I Long screw MX30 8 Thumb screw bracket II 8W Fluorescent lamp bracket III W Incandescent lamp Screw I MX8 Light unit Screw II MX Screw III MX6 3 inch adaptor connector (optional part) These Panasonic ceiling mount ventilating fan models use a sirocco fan with dolphin-shaped blades driven by a capacitor motor. The motor is designed to have an extended service life with reduced energy consumption. It also incorporates a thermal-cutoff for safety.the grille can be quickly detached from the main unit. A damper for preventing air counterflow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level. The light unit is an energy-saving, lighting device which uses two 8W fluorescent lamps and produces almost the same illumination as a standard 00W incandescent lamp.

FV-05VFL FV-08VFL FV-VFL Unit: inches( mm) 9 7 7/8 ( 73) ( 6) 3 / (90) 3/( 5) (5) 8 5/6 (7) 3 7/8 ( 98) 0 / ( 59 ) 7/8 (30) 3 / (8) 3 /~5 / ( 336~39 ) 6 /~8 3/ ( 9~80 ) /~3 / ( 50~597 ) 0 3/8( 0) 5 / () 3 ( 330) 6 0 / ( 6) 6 /8 (0) No. Part name No. Part name Grille 7 Junction box cover 8 Junction box 3 Body 9 Lighting unit assy Damper 0 Fluorescent lamp 5 bracket Night lamp 6 Bracket cover connector (For 6 inches on center joists,only use suspension bracket I, for 9. inches on center joists, only use suspension bracket III, If more than 9. inches on center,use suspension bracket II & III.)

Duct diameter (inches) Noise (sone) (cfm) FV-05VFL FV-08VFL FV-VFL 3 3 3 <0.3 <0.3 0.5 0.6.3.5 6 5 30 30 33 33 36 36 36 700 760 830 90 90 050 50 50 80 70 0 90.0 (5.0).0 (5.0).0 (5.0) Specifications are based on HVI standard. Unpack and carefully remove unit from carton. Refer to the Supplied Accessories list to verify that all parts are present. o o. Do not install this ventilating fan where air temperature may exceed 0 C (0 F).. Make certain that the electric service supply voltage is 0V, 60 Hz. 3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupation Safety and Health Act (OSHA).. Always disconnect the power source before working on or near the fan, motor or light fixture. 5. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects. 6. Do not kink the power cord. 7. Do not install the unit where ducts are configured as shown in Fig. A. 8. Provide suction parts with proper ventilation. 9. This unit is approved for use over a bathtub or shower when installed in a GFCI protected branch circuit. Fig. A

CAUTION:. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.. Not for use in cooking area. (Fig.B) 3. This product must be properly grounded. (Cooking area) Do not install above or inside this area 5 o 5 o Cooking equipment Floor Fig. B WARNING: To reduce the risk of fire, electric shock or injury to persons, observe the following; A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. B. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. C. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities. D. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. E. Ducted fans must always be vented to the outdoors. F. These models are UL listed for tub and shower enclosures. G. Solid state controls may cause harmonic distortion which can cause motor humming noise. Do not use this unit with any solid-state control device. H. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. I. NEVER place a switch where it can be reached from a tub or shower. J. Not to be installed in a ceiling thermally insulated to a value greater than R0.

. Before installation, secure the fan body to adaptor by using thumb screw.(fig.) Connection method for 3 inches adaptor connector Thumb screw Duct tape 3 inches adaptor connector 3 Fig. IMPORTANT: Remove the tape from damper and adaptor before installation. As show below:. Insert the supension bracket into the fan body and adaptor. (select the suspension bracket as show below) A Damper Remove the tape bracket I Fig.- Joists bracket I bracket III Fig.- Spacing A on center Joists Insert bracket inches Refer to Fig. - 6 inches Refer to Fig. - 9. inches vertical joists Refer to Fig. -3 inches Refer to Fig. - bracket III bracket I If spacing A on center joists is inches, connect suspension bracket II and III(C mark to C mark) as show below : bracket III Fig.-3 bracket III Screw I(MX8) bracket II bracket II bracket I Fig.- 6

3. Install the suspension bracket and the flange of fan body to joists by using long screws (MX30) ( If spacing A between joists is 0 /~ inches, install the flange of fan body according to Fig.3-, others according to Fig.3- install the product) Joist -Long screws(mx30) Fig.3- Joist -Long screws (MX30) Fig.3-. Install the suspension bracket to joists by using long screws (MX30) and secure it to the fan body by using screw II (MX) (Fig.) 5. Remove junction box cover and secure conduit or stress relief to junction box knock-out hole. (Fig.5) 6. Refer to wiring diagram below. Using wire nuts, connect house power wires to ventilating fan wires: black to black; white to white; green to green; Replace the junction box cover. Wiring diagram Current Fuse -Long screws (MX30) Junction box cover Conduit Circular duct screw II (MX) Fig. Fan unit Motor Moteur Red White Black White Green Capacitor Black Green white Electronic Ballast Light unit Lamp Power Supply AC0V 60Hz Duct tape or clamps Earth ground Night Lamp Junction box Black White Earth ground CAUTION: Mount junction box cover carefully so that lead wires are not pinched. Power Supply AC0V 60Hz Junction box Conduit Wire nut 7. Install a circular duct (using inches duct or 3 inches duct) and secure it with duct tape or clamps. 7 Lead wires Green wires Fig. 5

8. Finish ceiling work. Ceiling hole should be aligned with the edge of the flange. (Fig.6) 0 7/8 (75) 0 7/8 (75) 9. Insert the plug connector II and plug connector III into the receptacle II and receptacle III respectively, and secure the light unit to the fan unit with screw III (MX6) and machine screw (MX8). (Fig.6) 0. Insert the fluorescent lamps and screw the night lamp into the light unit.(fig.6) Machine screw (MX8) Light unit screw III (MX6) Ceiling Plug connector II Plug connector III Plug connector III Plug connector II Fluorescent lamps inches (mm) W Night Lamp Receptacle II Receptacle III Fig.6. Insert mouting springs into slots as shown and mount grille to fan body.(fig.7) Slot Light unit Mounting spring Ceiling Grille Fig.7. Disconnect plug connector from receptacle and remove adaptor from fan body before starting installation.. Insert the suspension bracket into the adaptor and secure it to joists by using long screws(mx30) (Fig.8) Keep the distance B (7/8 inch,.6mm) for the thickness of ceiling board. If spacing A between joists is / to 3 / inches (50mm~597mm), connect suspension bracket II and III (C mark to C mark) according to page. 8 Select the suspension bracket according to spacing A as show below. Spacing A between Joists inches (mm) suspension bracket 3 /~5 / ( 336~39 ) suspension bracket I 6 /~8 3/ ( 9~80 ) suspension bracket III /~3 / ( 50~597 ) suspension bracket II & III -Long screws (MX30) -Long screws(mx30) bracket Joists 3 /~5 / ( 336~39 ) 6 /~8 3/ ( 9~80 ) /~3 / ( 50~597 ) A 3. Follow steps 5 to 7 of the installation I (page 7) to complete the duct work and wiring. inches mm B ( ) Fig.8 8

. Insert the suspension bracket into fan body (refering to step of installation I, page 6) 5. Insert the fan body into joists. (Fig.9) IMPORTANT: Make sure that adaptor claws are properly inserted into body slots. 6. Secure the fan body to adaptor by using thumb screw and plug connector to receptacle(fig.0) 7. Secure the suspension bracket to joists by using long screws(mx30) and secure it to fan body by using screw II(MX) in vertical direction (Fig.) 8. Follow steps 8 to of Installation I (page 8) to complete the installation work. Joist Junction box cover Conduit Circular duct When mounting body and blower separately. Loosen screws (but do not remove them from blower). (Fig.-) -Screws Duct tape or clamps Slots claws. Remove blower section. (Fig.-) Fig.- 3. Remove adaptor from fan body and secure it to joists as in Fig.8 of page 8. Blower. Insert fan body (without blower section) into joists (Fig.9) Fig.- Fig. 9 5. Secure the adaptor to fan body by using thumb screw. (Fig.0) 6. Secure the fan body to joists by using long screw(mx30) (Fig.) 7. Insert the blower into the fan body. (Fig.-3) Fig.-3 Thumb screw Plug connector I Receptacle I Fig. 0 screw II (MX) 8. Secure the blower. (Fig.-) and plug connector to receptacle (Fig.0) -Screws Screw driver Fig.- -Long screws (MX30) Fig. 9

C C C C3 C kinds of I-joist inches (mm) 9/6 (.3) /6 (7.5) 3/3 (.6) 7/3 ( 38.9) C3 Thumb screw Fig.3 C C C bracket III The suspension bracket III can comply with different kinds of I-joists. bracket III Screw II(MX). Before installation, secure the fan body to adaptor by using thumb screw (Fig.3). Secure the lighting unit to fan body (refering to Fig.6 of page 8).. Connect the suspension bracket III to fan body. (Fig.) (Select the hole by checking I-joist size and fix the screw to the frame hole.) 3. Connect the ventilating fan to the I-joist. (Fig.5) Fig.. Follow steps 5 to of installation I (page 7, page 8) to complete the installation work. I joist -Long screws (MX30) Fig.5. Before installation, secure the fan body to adaptor by using thumb screw (Fig.3). Secure the lighting unit to fan body (refering to Fig.6 of page 8).. Insert the suspension bracket into bracket cover of adaptor side and the back of the fan body. (Fig.6) (select the suspension bracket according to spacing A as show below) A 6 inches and 9. inches horizental joist 9. inches vertical joist bracket I [ 6 inches and 9. inches horizental joist] bracket III [ 9. inches vertical joist] bracket III [ 6 inches and 9. inches horizental joist] bracket II [ 9. inches vertical joist] bracket II [ 6 inches and 9. inches horizental joist] bracket I [ 9. inches vertical joist] Fig.6 0

3. Insert the fan body between joists. Make sure the fan body is level and square (perpendicular) with the joists.(fig.7) Keep the distance B (7/8 inch,.6mm) for the thickness of ceiling board. Joists Ventilating fan Junction box A 3 /~5 3/ ( 336~00 ) 6 /~8 3/ ( 9~80 ) 3~5 (76~6) 5 /5~7 /5(8~98) inches( mm) Fig.7. Secure the suspension bracket to joists by using long screws(mx30) (Fig.8, Fig.9) -Long screws(mx30) Fig.8 5. Secure the suspension bracket to fan body by using screw II (MX) (Fig.9) -Screw II (MX) -Long screws(mx30) 6. Follow steps 5 to of installation I (page 7,page 8) to complete the installation work. Joist Fig.9. Before installation, secure the fan body to adaptor by using thumb screw (Fig.3 of page 0). Secure the lighting unit to fan body (refering to Fig.6 of page 8). Joist Header. Install header between joists by using nails or screws. 0 7/8 (75) 3/ (375) Joist 3. Install the ventilating fan and secure it by using long screws(mx30) (Fig.0, Fig.) Ventilating fan inches (mm) Fig.0

. Follow steps 5 to of installation I (page 7,page 8) to complete the installation work. Circular duct 6-Long screws (MX30) Junction box Conduit Wire nut Lead wires Green wires Fig.. Installation in existing construction. Installing the ventilating fan in an existing building requires an accessible area (attic or crawl space) above the planned installation location or existing ducting and wiring. () To install the ventilating fan, follow the procedures described in lnstallation II. Take the following precautions before installation. CAUTION: Check area above planned installation location to be sure that:. Duct work can be installed and that area is sufficient for proper ventilation.. Wiring can be run to planned location. 3. No wiring or other obstructions will interfere with installation. () Inspect duct work and wiring before proceeding with installation. (3) Plan suitable location for ventilating fan. (next to ceiling joist) () Before installation, provide inspection and maintenance access at a location that will not interfere with installation work shown in installation II. (5) First, remove ceiling section according to Fig.6 of page 8. (6) Install ventilating fan.. Installation from accessible area above fan location. () Inspect duct work and wiring before proceeding with installation. () Remove ceiling section according to Fig.6 of page 8. (3) Install ventilating fan.

WARNING: Disconnect power source before working on unit. Routine maintenance must be done every year. Slot CAUTION:. Never use petrol, benzene, thinner or any other such chemicals for cleaning the ventilating fan.. Do not allow water to enter motor. o 3. Do not immerse resin parts in water over 60 C. Glove Grille Mounting spring. Remove grille. (Squeeze mounting spring and pull down carefully.) (Fig.) Fig.. Wash and clean grille. (Use non-abrasive kitchen detergent, wipe dry with new cloth.) (Fig.3) Fig. 3 3. Remove dust and dirt from fan body using a vacuum cleaner.(remove bulbs if necessary.) (Fig.) Vacuum cleaner Fig.. Using a cloth dampened with kitchen detergent, remove any dirt from fan body. Wipe dry with new cloth. (Fig.5) 5. Replace bulbs and grille. Fig.5. Disconnect power source before working on unit.. The lamp's glass is fragile. Please handle with care. To remove lamp, grasp at base and move back and force to loosen.do not pull hard on the lamp or you may break the glass. 3. W night lamp has threaded base. Remove by turning counterclockwise. 3

. Remove grille. (Squeeze mounting spring and pull down) (Fig. of page 3) Plug connector III Plug connector II. Disconnect the connector II or connector III of light unit. (Fig.6) Receptacle II Receptacle III 3. Change the fluorescent bulbs (Panasonic FDS 8E7/,8W or FDS8E35/, 8W or FDS8E/, 8W ) or the W incandescent lamp, connect the connector II or connector III and replace the grille.(fig.7) W Night Lamp Fluorescent lamp Fig.6 Fig.7 Proper insulate the area around the fan to minimize building heat loss and gain. (Fig.8) Loose fill or batt insulation can be placed directly over the fan housing in the attic. Panasonic fans and fan/light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitors' fan/light combinations. Our efficient, cool-running motors and our fluorescent bulbs do not create enough ambient heat to be subjected to these limitations. Dryer-hood type vent with backdraft flap(s). Caulk termination to duct. -3 ft straight run before elbow. In attic installation, caulk box to drywall. Short piece of flexible duct helps alignment and absorbs sound. Clamps plus tape at all flex joints. Foil tape tightly covers all metal duct joints (glue PVC joints). Insulation. Fig. 8 Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. No service information is provided for customers. Your product is designed and manufactured to ensure a minimum of maintenance. However, should your unit ever require service, a nationwide system of factory service centers and AUTHORIZED INDEPENDENT SERVICE CENTERS is maintained to support your product's warranty. (In the U.S.A.,call -866-9-79 to Customer call Center.) PANASONIC CONSUMER ELECTRONICS COMPANY One Panasonic Way, H-3 Secaucus, NJ 0709 PANASONIC CANADA INC. 5770 Ambler Drive, Mississauga, ON LW T3