Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

Similar documents
Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

Catalog Applied Packaged Terminal Air Conditioner with Top-mounted Hydronic Heat

Incremental Comfort Conditioners

Engineered for flexibility and performance

Applied Packaged Terminal Air Conditioner

Applied Packaged Terminal Air Conditioner and Heat Pumps

Applied Packaged Terminal Air Conditioner and Heat Pumps

Engineered for flexibility and performance

Engineered for flexibility and performance

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

PTAC/PTHP. Packaged Terminal Air Conditioners and Heat Pumps. Residential & Light Commercial HVAC. Features: Performance:

Catalog 1304 Packaged Terminal Air Conditioner with Top-Mounted Hydronic Heat Model PGAN - Unit Sizes

Applied Packaged Terminal Air Conditioner and Heat Pump

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

E Z S E R I E S " W X 16" H

Zoneline vertical packaged terminal air conditioners

Specifications and Performance

Catalog Daikin Type K. Incremental Room Conditioner. Engineered for flexibility and performance

PTAC Air Conditioners 11.7 EER / 3.4 COP. and Heat Pumps

Catalog EnerSaver Packaged Terminal Air Conditioners and Heat Pumps

Daikin McQuay. Applied PTAC Air Conditioner and Heat Pump. PDAA, PDAE, PDAF, PDAN, PDHA, PDHE, PDHF Design 3

Specifications and Performance

EnerSaver Packaged Terminal Air Conditioner Catalog 1303 and Heat Pump with R-410A Refrigerant

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

McQuay. Applied PTAC Air Conditioner and Heat Pump PDAC, PDAA, PDAE, PDAN, PDAF PDHP, PDHA, PDHE, PDHF Design 1

MACH N-407 Heat Pump Air-Cooled Chiller

Applied Packaged Terminal Air Conditioner

General Description. Operation

McQuay Type J Series Incremental Conditioner

PTAC Air Conditioners 11.7 EER / 3.4 COP. and Heat Pumps

SpaceKeeper Console (SKC)

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

MAC N-407 Air-Cooled Chiller

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

R11C R12C R21C R22C/H R23C/H R24C/H

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

Q-TEC QC-Series Chilled Water Air Conditioner

Packaged Terminal Air Conditioners & Heat Pumps

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

SPXA / SPXA-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

SPXB / SPXB-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

SPXR-A / SPXR-HP-A Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

Q-Tec TM QC-Series Chilled Water Air Conditioner

Specifications and Performance

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

June PRODUCT DESIGN GUIDE Whisperline Console

NEW 2011 DESIGN AIR CONDITIONERS

Applied Packaged Terminal Air Conditioner

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Commercial High-Efficiency Condensing Units

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

GE Zoneline. vertical packaged terminal air conditioners Home Products and Services

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

CM R-410A High Efficiency Water Source Heat Pump

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

50TM COMBINATION HEATING/COOLING UNITS

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Specifications. Vertical Floor Consoles By First Co.

TECHNICAL SPECIFICATIONS

NEW! Digital Packaged Terminal Air Conditioners. Over 40 standard features! Distinct, audible sound improvements

SKYPAK II Heating & Cooling Self Contained Packages

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

all-season comfort GE Zoneline packaged terminal air conditioners New product introductions Spring 2010

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

Packaged Terminal Air Conditioner (PTAC)

PTAC 2017 Air Conditioner Collection

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

FRIGIDAIRE PTAC COLLECTION AIR CONDITIONERS

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

PRODUCT SPECIFICATIONS

Transcription:

Applied Packaged Terminal Air Conditioner with Catalog 1355-9 Top-Mounted Hydronic Heat 16" 42" Model PDAN Unit Sizes 007 017 R-410A Refrigerant Engineered for flexibility and performance

Unit Features 16" 42" Model PDAN with Top-Mounted Hydronic Heat Complete solution, high efficiency and very quiet five sizes from 7,000 to 17,000 Btuh B G A H F C E A. Heavy-Duty Grille Two-way adjustment allows air to be directed where it is needed. Option for extruded aluminum grille. B. Heating Chassis Top-mounted hydronic (steam or hot water) heat for easy installation. C. Room Cabinet Heavy-gauge steel with powder paint coating for maximum scratch and dent resistance. Removable for easy access to filters, controls and piping for routine maintenance and service. Option for custom cabinet colors. Custom depth for varying wall thicknesses. Available in front or bottom return configurations. D. Kick Plate Adjustable height and custom colors for varying floor treatments. E. Digital Touchpad Control Reliable and easy to read and operate. Continuous or cycle indoor fan operation. Automatic room freeze protection. D Infrared Remote (Option) Digital Touchpad Control F. Wall Sleeve Heavy-gauge steel with powder paint coating for maximum scratch, dent and corrosion resistance. Custom wall sleeve depths available. Options for brick or panel/curtain wall applications. G. Outside Air Louver Heavy-duty, architectural, extruded aluminum to resist weathering. Option for recessed louver. H. Cooling Chassis Energy efficient, quiet and reliable rotary compressor. Page 6 of 32 / Catalog 1355-9

Unit Features 16" 42" Model PDAN with Top-Mounted Hydronic Heat Digital Touchpad Control The PDAC/PDHP Standard Touchpad Control is used to control both an integral air conditioner and a source of heat. The user will by default control the electronic controller via the touchpad. The user can select with a jumper for the unit to receive commands from a remote thermostat. Standard (non-programmable) digital touchpad Provides 5-selectable modes of operation: Sleep, Cool, Cool/Dry, Fan, Heat Temperature can be displayed in Fahrenheit (default) or Celsius 9- LED Indicators Inputs and outputs Indoor coil sensor, (ICS) Outdoor coil sensor, (OCS) Indoor air sensor, (IAS) Outdoor air sensor, (OAS) Remote thermostat, T STAT (RCBYWG) Heat Fan Lock Out, (HFLO) Power supply: (24VAC) Line voltage input, (L1, L2) Indoor fan standby voltage, (L1STB L2STB) Control selection: (LUI, T STAT Model selection: (AC/E, HP, HP/E) Time delay bypass, (TEST) Indoor off fan cycle: (FAN, OFF CYCLE 10, 20, 30, 1 HR) Outputs Compressor output, COM Indoor fan, BLOWER LO, HI Outdoor fan, OUTDOOR FAN Electric heater, ELE Reversing valve, REV VALVE LED 2-Digit Display 7- Push Buttons Keys and indicators labels 7 Push Buttons 9 LED Indicators ON/OFF, FAN SPEED, MODE FAN MODE, SLEEP Temp buttons: for Temp UP and LED 2 Digit Displays No Label Display function legend Tr = Room Temperature hi = High Room Temperature Lo = Low Room Temperature LA = Low Ambient Lockout rt = Remote Thermostat Control tp = Touchpad Control t = Time Ts = Temperature Setpoint Rf = Room Freeze Condition CF = Coil Freeze Protection F = Fahrenheit C = Celsius LC = Control Lockout Mode for Temp DOWN SLEEP, COOL, COOL/DRY, FAN, HEAT, HIGH, LOW, CYCLE, CONT. Remote thermostat control The remote thermostat can be any thermostat that can interface with an electronic thermostat via RCB- WYG terminals. The Control Selection jumper must be in T STAT position. During a call the remote thermostat will pass R back to the controller on a respective terminal. The push buttons on the touchpad become inactive in the remote thermostat mode. However, the control pad LED display will indicate the mode of operation, and the room temperature. Notes: In terms of outputs, there are two types of thermostats: relay contacts and solid state. If you open the thermostat and don t see relays then it must be solid state. Manufacturers of solid state output thermostats include loading resistors on their installation kits. They are of 560 Ohm and 3W value. These resistors are meant to load thermostat solid state outputs in order for the output voltage to be either 0 or 24VAC, i.e. no floating voltage. These resistors are connected from W, Y, G to common (C), respectively. You can wire any type of 24Vac thermostat straight into the REMOTE T STAT connector of PTAC control boards, 667997101 and 667997201 (Basic and Premium models) and the control boards will recognize the signals from them. Page 8 of 32 / Catalog 1355-9

McQuay Model PDAN Product Nomenclature Note: For Illustration purposes only. Not all options available with all models. Please consult a McQuay Sales Representative for specific availability. Unit Type P = PTAC Product Identifier PDAN = Air Conditioner P DAN 2 009 E M A H A B A M A A E Warranty A = Standard E = Extended X = Special Design Series 1 = A Design 1 2 = B Design 2 3 = C Design 3 4 = D Design 4 5 = E Design 5 Unit Size 007 = 7,000 009 = 9,000 012 = 12,000 015 = 15,000 017 = 17,000 (Cooling Only) Voltage A = 115-60-1 E = 208/230-60-1 J = 265/277-60-1 P = 208/230-60-1 w/stndby 115-60-1 R = 265-60-1 w/stndy 115-60-1 T = 208/208-60-1 Brand Name M = McQuay Refrigerant A = R-410A Heating Type E = Electric Heat H = Hydronic A = Hydronic w/intermediate Electric Electric Heat A = 2.5 Kw B = 3.5 Kw C = 5.0 Kw Hydronic Heat Type S = Steam Top Mount (Normally Closed) H = Hot Water Top Mount (Normally Open) SKU A = Stock B = Build to Order Upgrade Packages S = Seacoast Power Connection L = Long Cord 72" (Standard) S = Short Cord 18" (Optional) Room Interface Cabinet Type A = Top-Mounted Hydronic Flat top, Bottom Return Controls Control Board Type PNUY = Premium, Non-Programmable, Unit Mounted PNWY = Premium, Non-Programmable, Wall Mounted PNRY = Premium, Non-Programmable, Infared PPUY = Premium, Programmable Unit Mounted PAUY = Premium, Programmable with Auto Changeover, Unit Mounted PPWY = Premium Programmable, Wall Mounted PPRY = Premium Programmable, Infrared Damper Type Damper Control A = Automatic (Required for Hydronic Heating Subbase) A = Fresh Air Boost Fan M = Manual Y = No Damper Catalog 1355-9 / Page 11 of 32

ARI Performance Data Cooling Page 12 of 32 / Catalog 1355-9 Total Btuh(1) 7,400 7,400 7,400 9,100 9,100 9,100 12,800 12,800 14,400 14,400 16,800 Sensible Btuh(1) 6,500 6,500 6,500 7,500 7,500 7,500 9,000 9,000 9,600 9,600 11,700 EER 10.9 10.9 10.9 10.7 10.7 10.7 9.8 9.8 9.4 9.4 9.3 Volts 115 208/230 265 115 208/230 265 208/230 265 208/230 265 208/230 Full Load Amps(6) 7.43 4.07 3.34 9.33 5.45 4.04 7.15 6.09 8.21 6.69 10.03 Watts(1) 679 679 679 850 850 850 1,306 1,306 1,532 1,532 1,806 Volts 208/230 265 208/230 265 208/230 265 208/230 265 208/230 2.5 kw kw 2.2/2.7 2.2/2.7 2.2/2.7 2.2/2.7 2.2/2.7 Amps 10.7/11.9 10.7/11.9 10.7/11.9 10.7/11.9 10.7/11.9 Electric Heat(3) kw 3.1/3.8 3500 3.1/3.8 3500 3.1/3.8 3500 3.1/3.8 3500 3.1/3.8 3.5 kw Amps 15.2/16.8 13.7 15.2/16.8 13.7 15.2/16.8 13.7 15.2/16.8 13.7 15.2/16.8 Hydronic Heat(4) Cooling 5.0 kw Valve & Fan Motor Amps kw 3.9/4.8 5,000 3.9/4.8 5,000 3.9/4.8 Amps 19.0/21.0 19.3 19.0/21.0 19.3 19.0/21.0 0.74 0.41 0.32 0.74 0.41 0.32 0.41 0.32 0.41 0.32 0.47 Hot Water (Btuh) Hi/Lo 18,400/15,600 18,400/15,600 18,400/15,600 18,400/15,600 23,200/16,400 Steam (Btuh) Hi/Lo 22,400/22,300 22,400/22,300 22,400/22,300 22,400/22,300 27,900/23,300 Heat Pump Model Qt, Btuh(2) 7,400 7,400 7,400 9,200 9,200 9,200 12,700 12,700 14,200 14,200 Qs, Btuh(2) 6,500 6,500 6,500 7,500 7,500 7,500 9,000 9,000 9,500 9,500 EER 10.9 10.9 10.9 10.3 10.3 10.3 9.8 9.8 9.4 9.4 Volts 115 208/230 265 115 208/230 265 208/230 265 208/230 265 Full Load Amps 7.43 4.07 3.34 9.33 5.45 4.04 7.15 6.09 8.21 6.69 Watts(1) 679 679 679 893 893 893 1,296 1,296 1,511 1,511 Btuh(2) 6,800 6,800 6,800 8,500 8,500 8,500 12,400 12,400 14,000 14,000 Reverse COP 3.2 3.2 3.2 3.3 3.3 3.3 3.0 3.0 2.9 2.9 Cycle Volts 115 208/230 265 115 208/230 265 208/230 265 208/230 265 Heat Full Load Amps 7.43 4.07 3.34 9.33 5.45 4.04 7.15 6.09 8.21 6.69 Watts(2) 623 623 623 755 755 755 1,211 1,211 1,415 1,415 Electric Heater Voltage 240V 265V 240V 265V 240V 265V 240V 265V 240V Minimum Circuit Ampacity UNIT SIZE 007 009 012 015 017 2.5 Kw 14.3 14.3 14.3 14.3 14.3 3.5 Kw 19.3 16.4 19.3 16.4 19.3 16.4 19.3 16.4 19.3 5.0 Kw 28.3 22.2 28.3 22.2 28.3 Hydronic Heat 8.69 4.77 3.89 11.06 6.49 4.77 8.48 7.22 9.8 7.97 12.07 2.5 Kw 15 15 15 15 15 Time Delay Fuses 3.5 Kw 20 15 20 15 20 15 20 15 20 or Type HACR 5.0 Kw 25 20 25 20 25 Circuit Breaker Hydronic Heat 15 15 15 15 15 15 15 15 15 15 15 2.5 Kw 6-15R 6-15R 6-15R 6-15R 6-15R NEMA 3.5 Kw 6-20R 7-20R 6-20R 7-20R 6-20R 7-20R 6-20R 7-20R 6-20R Receptacle Type Required 5.0 Kw 6-30R 7-30R 6-30R 7-30R 6-30R Hydronic Heat 5-15R 6-15R 7-20R 5-15R 6-15R 7-20R 6-15R 7-20R 6-15R 7-20R 6-15R High Low High Low High Low High Low High Low Airflow Cool 360 330 360 330 360 330 360 330 540 360 CFM Heat 380 340 380 340 380 340 380 340 550 380 Vent(5) 50 40 50 40 50 40 50 40 70 50 (1) Based on ASHRAE and ARI test conditions of 95 F DB/75 F WB outside, 80 F DB/67 F WB inside. (2) Based on ASHRAE and ARI test conditions of 47 F DB outside, 70 F DB inside. (3) Electric Resistance Heat Watts x 3.41 = Btuh. Electric Heating Watts and Amps include Indoor Fan Motor. (4) Water Based on ASHRAE and ARI test conditions of 200 F EWT, 180 F LWT, 70 F EAT with a 1.8 gpm flow rate. (5) 90 cfm with Power Vent Option. (6) Cooling Full Load Amps includes Compressor, IDF and ODF FLA's. Unit Weights - (lbs.) Model 007 009 012 015 017 16" 42" PDHP (Packaged) 146.0 153.5 154.4 162.1 16" 42" PDAC (Packaged) 144.5 152.0 152.9 160.6 160.6 16" 42" PDHP (Chassis) 131.0 138.5 139.4 147.1 16" 42" PDAC (Chassis) 129.5 137.0 137.9 145.6 145.6 = Not Applicable = Not Applicable

Dimensional Data Unit Dimensions Chassis Premium Digital Touchpad Control Unit Dimensions Wall Sleeve, Cabinet & Louver 1 1 4" RECESS FOR ARCHITECTURAL LOUVER A IN. (MM) D IN. (MM) B IN. (MM) ROOM CABINET WALL SLEEVE WALL THICKNESS 18 3 4 (476) 13 3 4 (349) 4 3 4 5 3 4 (121 146) 17 3 4 (451) 13 3 4 (349) 5 3 4 6 3 4 (146 171) 16 3 4 (425) 13 3 4 (349) 6 3 4 7 3 4 (171 197) 15 3 4 (400) 13 3 4 (349) 7 3 4 8 3 4 (197 222) 14 3 4 (375) 13 3 4 (349) 8 3 4 9 3 4 (222 248) 13 3 4 (349) 13 3 4 (349) 9 3 4 10 3 4 (248 273) 12 3 4 (324) 13 3 4 (349) 10 3 4 11 3 4 (273 298) 11 3 4 (298) 13 3 4 (349) 11 3 4 12 3 4 (298 324) 10 3 4 (273) 13 3 4 (349) 12 3 4 13 3 4 (324 349) 10 3 4 (273) 14 3 4 (375) 13 3 4 14 3 4 (349 375) 10 3 4 (273) 15 3 4 (400) 14 3 4 15 3 4 (375 400) 10 3 4 (273) 16 3 4 (425) 15 3 4 16 3 4 (400 425) 10 3 4 (273) 17 3 4 (451) 16 3 4 17 3 4 (425 451) 1 1 2" (38mm) Note: Electrical rough-in should be located behind kickplate (removable front) and below wall sleeve. 52" (1320mm) Standard Size Wall Sleeve A Wall Thickness B 2 7 8" (67mm) 1 1 4" (32mm) 19 1 2" (495mm) 3" (76mm) Min. 3" (76mm) Wall Space For Piping Rough-in (Typ. R.H. & L.H.) Kickplate (Removable Front) 7/8" (22mm) 5 1 2" (140mm) 1 5 16" (33mm) 9 1 8" (232mm) 1 5 8" (41mm) D 16" (406mm) 7/8" (22mm) 3" (76mm) Min. Kickplate Height Catalog 1355-9 / Page 13 of 32