RESISTENT PLUS D A CH Gebrauchsanleitung GB IRL AUS USA NZ CDN IND Instructions for Use... 12

Similar documents
RESISTENT EXTRA 3592, 3602 RESISTENT EXTRA PLUS 3592P, 3602P

Compression Sprayers TECH DATA SHEET /03/17. Ersatzteile Spare Parts Pièces de Rechange

Compression Sprayers CLEANER 3275PP, 3270PP, 3275PE, 3270PE PROFI PLUS 3275P, 3270P PROFI PLUS 3275P, 3270P TECH DATA SHEET /03/17

USER S MANUAL ATH WH220

Camping Toilet USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING & USING THE CAMPING TOILET

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

BEFORE FIRST USE: TABLE OF CONTENTS

Installation & Service Manual

Waste water ejection unit

ALL IN ONE SERIES HOTLINE 1300 AQUATEC INSTRUCTION MANUAL MODEL 03AS310 03AS311. DATE JULY 2017 v2.0. AQP All in One 1000 Instructions.

User Manual. Deep Cleaning Bagless Vacuum with Powerhead. Deep Clean W3000

2 000W CYCLONIC BAGLESS VACUUM

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Because you re not like everyone else. MISTING FAN MF26B OWNER S MANUAL

X99 Series. Dental Handpiece. Instruction For Use

BEVERAGE COOLER. 3.2 Cubic Feet. Before using your Beverage Cooler, please read this manual.

Operating instructions (translation) Stunning Device for Small Animals

INSTRUCTIONS MANUAL. 8-Speed Stand Mixer

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

NEPTUN I Sole cleaning unit Art.-No.:

RX550i Electric Pressure Washer

Single Lever Pull Out Kitchen Faucet

Read these instructions before using and keep them available at all times!

USERS MANUAL FOR GAS BOILERS

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Operation Manual 322 KL

Ireland. Australia. New Zealand

Model K 520 M Part No

s y ens Av Avensys FIN EST RUS SLO RUS UAE

INSTRUCTIONS AND WARRANTY

Cool Mist Ultrasonic Humidifier

HC12W COOL MIST ULTRASONIC HUMIDIFIER OWNER S MANUAL. Read and save these instructions.

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

Avensys Avensys FIN EST SLO RUS UAE

BEFORE OPERATING THE MACHINE: WARNING

INSTRUCTIONS AND WARRANTY

B Saneo. Saneo. Saneo BS Saneo CS Saneo BW Saneo CW. C Saneo BLP Saneo CLP. Dometic Dometic. Dometic Dometic. Dometic Dometic.

INSTRUCTION MANUAL W-400

Because you re not like everyone else. MISTING FAN MF24B OWNER S MANUAL

45L & 60L FRIDGE USER MANUAL

Ireland. Australia. New Zealand

Instructional & Operating Manual

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

MODEL NO RUSSELL HOBBS APOLLO 1.8L DIGITAL FILTER COFFEE MAKER

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

SOOTHING COOL MIST AROMA DIFFUSER

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

Installation Instructions PP-AS20 Anti-Scale System

Fig. 2. Fig. 1. Fig. 3. Fig. 4. Fig. 5. Fig. 7 Fig. 6. Fig. 9. Fig. 8. Fig. 10 MAX H2O

Operating Manual. VIENNA Hot Display

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

WXHAP Washington Street Melrose, MA Phone Toll Free Visit us at

Porter & Charles OPERATION MANUAL. Gas Cooktop CG60S, CG76S, CG90S, CG60W, CG90W

Avensys Avensys FIN EST SLO RUS UAE

PATIO CLEANER PPC 30 PATIO CLEANER. Translation of original operation manual

AUTOMATIC GRANULAR ICE FLAKER

ispring Whole House Water Filter Systems USER S MANUAL

PORTABLE SMART WASHER

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

Model HD 3501 Part No High Pressure Washer Operator Manual

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

K Specifications. Max. Water Volume

Model K 240 plus Part No

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE:

PJ130S High Pressure Cleaner

Operating instructions

CONGRATULATIONS! TABLE OF CONTENTS

SAFETY, OPERATION AND MAINTENANCE MANUAL. MX-1408 SELF-CONTAINED EXTRACTOR This unit is intended for commercial use.

Vintage Desk Fan. Model: SF1010 (all colours) Helpline. v1.1

IMPORTANT SAFETY INFORMATION:

Ireland. Australia. New Zealand

4.9 CU.FT. BEER KEG COOLER INSTRUCTION MANUAL. Model No.: MCKC490S

Owner s. 18 Misting MF18W. To view

EN Instruction manual

English 6. Copyright DEWALT

Because you re not like everyone else. MISTING FAN MF18W OWNER S MANUAL

AIR COMPRESSOR TC UTC TC UTC125502

AUTOMATIC ICE-CUBE MAKER

ICE MAKER. 26 Lbs. Capacity HME010019N. Before using your Ice Maker, please read this manual.

Model K 330 M Part No

Read these instructions before using and keep them available at all times!

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

testo 316-EX gas leak detector Instruction manual

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

ULTRASONIC HUMIDIFIER

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

USER MANUAL. Intelligent toilet Primus

Universal vacuum. Operation Manual LS 5000 ESW. Machine no. Models. Universal vacuum LS 5000 ESW Original Operation Manual

Installation Instructions Model: EB Single-Lever Lavatory Faucet

Test Lamp for 210 series flame detectors Non EX

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

VHC200 AIRPOWERED VACUUM CLEANER OPERATOR MANUAL

Transcription:

RESISTENT PLUS 3594 D A CH Gebrauchsanleitung... GB IRL AUS USA NZ CDN IND Instructions for Use... 12 F CH B NL CDN Mode d'emploi... 18 E MEX Instrucciones de uso... 24 MESTO Spritzenfabrik Ernst Stockburger GmbH Ludwigsburger Straße 71 D 7191 Freiberg / Neckar Tel : +49 71 41 27 20 Fax : +49 71 41 27 21 00 E-mail : info@mesto.de Internet : http://www.mesto.de

Ersatzteile Spare Parts Pièces de Rechange Varaosat Reserve-onderdelen Varuosade Pezzi di ricambio Reservdelar Reservedele RESISTENT PLUS 3594

1 2 7 3 7 5 1 2 4 8 13 5 9 10 3 4 1 4 4 5 3

1 10 7 8 11 9 10 12 1 11 12 13 4

14 15 1 14 13 14 12 17 15 1 13 18 19 20 17 18 21 5

GB IRL AUS USA NZ CDN IND Welcome and congratulations for purchasing your new MESTO sprayer. Thank you for the trust you have shown in our brand. Your satisfaction with MESTO products and services is very important for us. Please contact us if your expectations are not met. You will find our address on the title page of these instructions for use. Make certain to read the instructions for use before using the device! Usage Keep the instructions for use in a safe place where they can be easily found. Spraying devices RESISTENT PLUS 3594 are designed for the spraying of professional pesticides, plant protection products including weed killers, forming oil and low-viscosity mineral oils, slightly alkaline construction chemicals (ph 9) and neutral, solvent- and chlorine-free cleaning agents. Observe the manufacturer s instructions for using the product before each application. The sprayers must only be used in the exterior. At the time of manufacturing, there are no known harmful effects to the device caused by plant protection products approved by the Federal Office of Consumer Protection and Food Safety. Improper use may result in dangerous injuries and environmental damage. You should only use other products if harmful effects on the device and endangerment of people and the environment can be excluded. On request, we will provide you with a list of active ingredients used in the sprayer. Not suitable for Inflammable liquids Hydrogen peroxide and similar substances that give off oxygen Corrosive substances (certain disinfecting and impregnating agents, acids and bases) Liquids containing ammonia Solvents and liquids containing solvents Viscous or sticky liquids or liquids that form residues (dyes, greases) Use in applications for foodstuffs. Under no circumstances should you use external pressure sources without a MESTO compressed air valve for flaming for storing and holding liquids as an eyewash. Safety Children and adolescents who have not been properly instructed must not use the device. Keep the sprayers safe from access to children. Take precautions to prevent hazardous substances from being misused. Never spray on people, animals, electrical devices and lines, into the wind, or into bodies of water. 12

GB IRL AUS USA NZ CDN IND Repairs and modifications to the tank are not permitted. The effect of the safety valve must not be bypassed or made inoperative. Contact between sprayer materials and hydrogen peroxide or other agents that give off oxygen may result in increased pressure similar in nature to an explosion. Never place such agents in the device. Have damaged parts or parts that do not work properly repaired immediately by our customer service department or by service partners authorized by us. Do not allow the device to remain under pressure and/or exposed directly to sunlight. Make certain the device is not heated beyond the maximum operating temperature. ( Table 1 below). Never blow through the nozzles or valves with your mouth. Use only MESTO spare and accessories. We cannot assume any liability resulting from the use of third-party parts. Wear suitable protective equipment when working with hazardous substances. When pumping, always observe the pressure gauge to ensure the maximum spraying pressure is not exceeded ( Table 1 below). Before filling, after use and before maintenance work, allow the residual pressure in the tank to dissipate completely ( Section "After Use", Section 1). Collect and dispose of the spraying agents according to all applicable laws, requirements and regulations. Scope of delivery Tank [4] with pump [1], instructions for use [2], spare parts pouch [3], spray wand [5], shutoff valve [], spray line [7] (Fig. 1) You will find the illustrations referred to in the text in the front fold-out pages 3 5 of these instructions for use. Technical data Device family RESISTENT Type 3594 Max. filling amount 4 l Total contents 5 l Max. spraying pressure bar Max. operating temperature 50 C Weight when empty 2.8 kg Material of tank Stainless steel Technical residual quantity 0.03 l Max. volume flow 4.5 l/min Recoil force < 5 N Table 3 13

GB IRL AUS USA NZ CDN IND Assembly 1. Screw the spray line [7] securely into the tank [4] with a size 13 (metric) wrench. (Fig. 2) 2. Screw the spray wand [5] onto the shut-off valve []. (Fig. 2) Checks Visual inspection: Are the tank [4], pump [1], spray line [7] with shut-off valve [], pressure gauge [11] and spray wand [5] undamaged? (Figs. 2, 9) Pay special attention to the connections between the tank spray line and the spray line shut-off valve and to the condition of the pump threading and spray line. No leaks: Pump up the empty device to 2 bar. The pressure must not decrease more than 0.5 bar within 30 minutes. Function: Pull the red button on the safety valve [9]. (Fig. 3) The pressure must dissipate. Activate the shut-off valve []. (Fig. 10) The shut-off valve must open and close. Making preparations Observe the instructions in the section entitled "Safety". 3. Pull up the red button on the safety valve [9] until all excess pressure is released from the tank. (Fig. 3) 4. Press the pump handle [10] down and turn it counterclockwise. The pump handle is locked in place. (Fig. 4) 5. Unscrew the pump [1] from the tank [4]. (Fig. 5) We recommend you mix the spraying liquid in the device or premix it in an external tank: Fill to 1/3 with water, pour in the spraying agent, and then add more water until full.. Add the spraying liquid to the tank [4]. (Fig. ) 7. Screw the pump [1] onto the tank [4]. (Fig. 7) 8. Press the pump handle [10] down and turn it clockwise. The pump handle is unlocked. (Fig. 8) 9. Generate the required pressure ( Table 2) in the tank [4] (Fig. 9). The maximum pressure should not exceed bar (red line on the pressure gauge [11], Fig. 9). If the maximum pressure is exceeded, the safety valve will engage and release the excess pressure. 10. Press the pump handle [10] down and turn it counterclockwise. The pump handle is locked in place. (Fig. 4) Spraying Observe the instructions in the section entitled "Safety". Operate the device upright only. Avoid allowing drops of spray to drift onto areas that are not being treated. Observe the instructions of the spray product manufacturer! To prevent dripping, hold the spray wand up when first spraying and activate the shutoff valve until no more liquid mixed with air is emerging from the nozzle. 1. Activate the shut-off valve []. (Fig. 10) Spraying may now begin. 14

GB IRL AUS USA NZ CDN IND 2. Make certain the optimum spraying pressure is set ( Table 2) on the pressure gauge [11]. Spraying Spraying quantity with nozzle 1302 pressure 1.5 bar 0.49 l/min 2.0 bar 0.5 l/min 3.0 bar 0.9 l/min Table 4. Linear relationship of: spraying rate and spraying pressure 3. If the spraying pressure decreases more than 0.5 bar from the optimum level, pump some more. If liquid mixed with air emerges from the nozzle, the tank is empty. After Usage Observe the instructions in the section entitled "Safety". 1. Pull up the red button on the safety valve [9] until all excess pressure is released from the tank. (Fig. 3) 2. Lock the pump handle in place [10]. (Fig. 4) 3. Unscrew the pump [1] from the tank [4]. (Fig. ) Collect and dispose of the residual liquid according to all applicable laws, requirements and regulations. Observe the instructions of the spray product manufacturer! 4. Wipe off the device with a moist cloth. 5. For drying and storing the device, keep the tank and pump separate in a dry place protected from sunlight and freezing temperatures. Clean the protective equipment and yourself every time after usage. Care and maintenance Observe the instructions in the section entitled "Safety". After using the device 50 times or at least once a year: Disassemble the pump [1] and grease the diaphragm [13]. (Figs. 11-12) Clean the nozzle [14] and insert [15] under flowing water. If necessary, use a needle. (Fig. 13) Take the filter [1] out of the shut-off valve [] and clean it under running water. (Fig. 14) Grease the O-ring [12]. (Fig. 12) Observe the legal requirements of your country for accident prevention and check the device in regular intervals. If there are no special rules, we recommend you have the device examined externally by a competent professional every 2 years and subject it to an internal inspection every 5 years. We would be happy to provide you with an inspection schedule in German or English. 15

Faults GB IRL AUS USA NZ CDN IND Use only MESTO spare parts and accessories (you will find some in the spare-parts pouch [3], Fig. 1). Fault Cause Remedy No pressure builds up in the device Liquid flows out of the pump The nozzle does not spray even though pressure is present Only spray, no atomization The shut-off valve does not close. Liquid emerges without the lever being activated. The pump is not screwed on tightly O-ring [12] on the pump is faulty (Fig. 1) Diaphragm [13] is defective (Fig. 1) The valve disc [17] is dirty or faulty (Fig. 15) Filter [1] (Fig. 14) or / and nozzle [14] (Fig. 13) is clogged Insert [15] missing (Fig. 13) Seal of the tension bolt [20] not greased Tension bolt [20] or seal defective(fig. 18) Contact address for additional information see title page. Screw the pump on tightly Replace the O-ring Replace the diaphragm Clean or replace the valve disc Clean filter or / and nozzle (Figs. 13 + 14) Position the insert in the nozzle Unscrew screw [18] from the shut-off valve [] to remove the lever [19]. (Fig. 17) Unscrew screw seat [21] and press out tension bolt [20]. (Fig. 18) Clean and grease seal of the tension bolt [20] or renew tension bolt [20]. (Fig. 18) Install in reverse sequence. 1

GB IRL AUS USA NZ CDN IND Warranty We guarantee that from the time it is first purchased for a period of the legally valid required warranty period (maximum 3 years) this device will not exhibit any material or processing errors. If defects are discovered during the warranty period, MESTO or the distributor in your country will repair the device without charging for the labor or material or (at the discretion of MESTO) replace the device itself or its defective parts. If such defects are discovered, please contact us immediately. We require the invoice or cash register receipt for purchase of the device. The warranty does not include wearing parts (seals, O-rings, diaphragm, etc.) or defects, which have occurred due to improper use or unforeseeable circumstances. CE Declaration of Conformity In accordance with EC Directive 200/42/EC, Annex II, No. 1A. We, MESTO Spritzenfabrik Ernst Stockburger GmbH Ludwigsburger Straße 71, D-7191 Freiberg declare under our sole responsibility that the Series 3594 high pressure sprayers as supplied from factory number 128953 meet all the relevant requirements of Directive 200/42/EC of the EU. Furthermore the devices correspond to Directive 97/23/EC for Pressure Equipment. Rolf Rehkugler, Ludwigsburger Straße 71, D-7191 Freiberg is authorized to compile the technical documentation. Freiberg, 21.10.2012 Bernd Stockburger - Managing Director - 17