PACKAGED METALLIC BURNERS

Similar documents
FLAT FLAME AND EXCESS AIR BURNERS

EXCESS AIR BURNERS XNM SERIES FEATURES APPLICATIONS DESCRIPTION. Bulletin E3502 rev05 31/01/00

INFRA-RED BURNERS BR-70 SERIES FEATURES APPLICATIONS. Bulletin E3005 rev03 31/01/00

Burners. Long flame burners Nozzle Mix NM - (E3501 rev /05/2015)

Burners. Monoblock free flame burners EPB (E3007 rev /07/2016)

Burners. Monoblock free flame burners EPB (E3007 rev /11/2017)

INDITHERM. Low temperature gas burners

Burners. Self-recuperative burners high speed free flame REKO-SIK-NxT-FF (E3901FN rev /02/2018)

Burners. Self-recuperative burners high speed free flame REKO-SIK-FF (E3901F rev /08/2015)

SELF - RECUPERATIVE BURNERS HIGH SPEED FREE FLAME REKO-SIK-FF. E3901FF rev /05/2009.

ESA Pyronics International R&D test center

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

INDITHERM. Low temperature gas burners

Bert Uneken, Field Engineering Manager Ruben Kranenburg, Technical Support

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

Eclipse 90 UV Scanner Model A Version 1

NMC Nozzle Mix Gas/Oil Combination Burners

INDUSTRIAL MICRODIFFUSION OIL BURNERS

Eclipse Self-Check UV Scanner

OPERATING AND MAINTENANCE MANUAL

Electronics. Microprocessor operated burner control device ESA ESTRO (E7014 rev /11/2009)

Design Guide /12/2008. Eclipse RatioAir Burners RA Series Version 1

Design Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Design Guide No /01. RatioMatic Burners. RM Series Version 3.10

Eclipse RatioMatic Burners

PBG PACKAGED GAS BURNER

MICROPROCESSOR OPERATED BURNER CONTROL DEVICE ESA ESTRO SERIE

Eclipse AirHeat Burners

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

PYRO-LINE BURNERS 126LX 6LE 12LS DESCRIPTION MODEL: 3201

Eclipse AirHeat Burner

Self-recuperative burner for gas

Steam Fundamentals. (in heating & processing applications)

26 Mesh Belt Brazing Annealing Furnace. Continuous Mesh Belt Brazing Furnace

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

ECLIPSE INFORMATION GUIDE

Specifications of V-Line burners

DELTA-TE III. Nozzle-mix line burner

CONDOR RAPID CONDOR RAPID/V STEAM FORCED CIRCULATION. Design pressure 11,76 bar Steam production from 45 to Kg/h

Pilot Burner and Direct Spark Ignition (DSI) Applications with Flame Rectification Sensing

MULTIPLEX SELF RECUPERATIVE gas burner

Distributed By: M&M Control Service, INC

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

INFRARED RADIANT GAS SYSTEMS FOR THERMAL TREATMENTS

Control valve S11T. Pilot burner ZT. Control valve S11T

Electronics. Burner control and flame detector for permanent and not-permanent operation ESA REFLAM-H (E7802 rev /04/2017)

SULPHUR RECOVERY UNIT

Fireye FLAME SCANNERS

SHP High Pressure Radiant Gas Brooder Series

"NP" & "RG" AIRFLO. In-duct firing line burner

Chemical Processes in the Combustion

APX. Nozzle-mix line burner

GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7. Model C Forced Draft Burners. Natural Gas or Propane MODEL C10

Intermittent Pilot Ignition (IPI) and Direct Spark Ignition (DSI) Applications with Flame Current Probes

LINDOFLAMM thermal engineering.

Compact wall hung boiler. Micro processor Brass Hydraulic set

NMG NOZZLE MIX GAS BURNERS

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world

Type CG Series Forced Draft Gas Burner

Gas Safety. Syllabus. For 120kW. Class B gas fitter. Certificate of qualification examination

F900 SERIES GAS CHARGRILL G9440, G9460, G9490, G User, installation and servicing instructions T Read these instructions before use

SAGV x 1/1 GN 7-12 x 20 COMBI STEAMER FOR GASTRONOMY

Design and Application Details

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Since 1983 Nuova COTERM has developed a wide range of water heaters.

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

FIREYE FLAME SCANNERS

Specifications of MULTIFIRE burners

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

Burners Flares Incinerators Vapor Combustion

Oil burners fuel unit with solenoid valve

Eclipse AirHeat Burners AH Series version 2.00 (Patent Pending)

WF WAVE SERIES: WF 42 AND WF 60 PIZZA OVENS REPLACEMENT PARTS LIST

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

"HC" AIRFLO. In-duct firing line burner

Burn Easy Installation Instructions LP or Natural Gas Fired Units. Cremator Setup:

Q382A,B Pilot Burners

Indirect gas-fired air heater

Installation Instructions

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

RIELLO 40 GS/M SERIES

UV - flame detector dual fuel burners for intermittent burner operations

1 - High-velocity gas burners

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

DESCRIPTION AND INSTALLATION

Products & Services. DISTRIBUTOR & FOREHEARTH SYSTEMS

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

HEADLINE LOREM IPSUM COMPANY EFFICIENCY

USER S GUIDE FOR OVEN RANGE AND COMBINATION

Oil burners fuel unit with solenoid valve

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

Transcription:

FEATURES PACKAGED METALLIC BURNERS FC SERIES Bulletin E00 rev0 /0/0 Burner body: Burner cone: Nozzle: Optional shield: Capacity range: Adequate to different types of gas: Excellent flame stability with: iron AISI AISI0 AISI 1 to kw CH /L.P./propane/etc. excess air on ratio firing Low No x level. Wide turndown range. High excess air. Easily replaced electrodes. Separated air and gas inlets, mixing at discharge point, no flashback. Compact, light, small burner supplied with air blower, pressure switch, gas adjuster, flame and sight electrodes, peepsight, orifice flow meter (CH /L.P.). F00I01 F00I0 APPLICATIONS Air heaters. Steam generators. Incinerators. Driers. Foodstuffs ovens. Textile and dying machines (Rameuse). F00I0 Headquarters Esa S.r.l. Via E. Fermi 0 I-0 Curno (BG) - Italy Tel. +.0.711 - Fax +.0.7 esa@esacombustion.it - www.esapyronics.com International Sales Pyronics International S.A./N.V. Zoning Ind., ème rue B-00 Jumet - Belgium Tel +.71.70 - Fax +.71.7 marketing@pyronics.be

DESCRIPTION FC burners are used in low temperature processes. An air blower is mounted on the burner and supplies the air necessary for combustion. The air flow is always the same and thermoregulation occurs in excess air therefore varying the gas flow. This ensures excellent flame stability over varying operating conditions and subsequent homogeneous temperature and air in the combustion chamber. The nozzle allows for extremely high turndown ranges, from 0 1 to 0 1 according to the model. FC burners are simple and easy to install thanks to their compactness, metallic construction, light weight and small size. They are particularly adequate to operate with negative or atmospheric pressure combustion chambers. If they are mounted on positive pressure combustion chambers, it is necessary to know their true capacity to obtain better results. FC burners are on-off, two steps or modulating systems. INSTALLATION FC burners may be installed to operate in any position. Use mounting flange with standard threading. The gas inlet may be rotated and is equipped with gas adjuster, model GAF. A refractory block or steel flame shield may be supplied on request. The entirely pre-mounted version with all the devices for the supply gas pipe (see the enclosed charts) is also available. IGNITION AND FLAME DETECTION Burner ignition is achieved by a direct spark ignition electrode Wand; a pilot burner PPBST-W/X may be also supplied on request. Flames can be monitored using an electrode ; UV- ultraviolet scanners may also be used on request. Flame detection systems are required on all burners with furnace temperature below 70 C. Catalog No. Pilot burner ignition Electrode ignition Ignition Detection Ignition Detection PPBST-W/X PPBST-W/X PPBST-W/X Wand Wand Wand FLAME DIMENSIONS - CAPACITY TABLE Catalog No. Flame lenght mm Capacity kw Flame diameter mm 00 00 1 00 00 0 0 00 00 0 NOTE: Flame lenght are approximate, referred to burner feeded with natural gas, free air, working at stoichiometric ratio and at nominal capacity. /7

NATURAL GAS CAPACITY TABLE Pressure drop at orifice flow meter (mbar) FC FC FC1 1 0 Natural gas flow (Nm /h) @ 0 C G00I01 L.P. CAPACITY TABLE Pressure drop at orifice flow meter (mbar) FC FC FC1 1 0 L.P. flow (Nm /h) @ 0 C G00I0 /7

FLOW CHART (on-off) D00I01 POS. 1 7 1 1 1 1 17 1 1 0 1 Model identification Gas ball valve Flexible connector Gas filter Reducing regulator Orifice flow meter Flow indicator Low pressure gas limit switch High pressure gas limit switch Rapid opening safety solenoid valve Slow opening safety solenoid valve Gas adjuster Flame rod Spark electrode Ignition transformer UV-scanner with housing Metallic burner Low pressure air limit switch Combustion air blower Burner control device Thermocouple Thermoregulator RSO/T ø1 FN ø1 G ø1 SR- ø/ POP-U-S VM-R ø1 VM-L ø1 GAF ø1 DG--U MN 0 SR- ø1 VM-L ø1.1/ GAF ø1.1/ DG--U MN 0 SR- ø1.1/ VM-L ø1.1/ GAF ø1.1/ DG--U MN 0 /7

FLOW CHART (modulating) D00I0 POS. 1 7 11 1 1 1 1 17 1 1 0 1 Model identification Gas ball valve Flexible connector Gas filter Reducing regulator Orifice flow meter Flow indicator Low pressure gas limit switch High pressure gas limit switch Rapid opening safety solenoid valve Slow opening safety solenoid valve Motorized gas adjuster Gas adjuster Flame rod Spark electrode Ignition transformer UV-scanner with housing Metallic burner Low pressure air limit switch Combustion air blower Burner control device Thermocouple Thermoregulator RSO/T ø1 FN ø1 G ø1 SR- ø/ POP-U-S VM-R ø1 VM-L ø1 GTV ø1 VL-R-CMAP ø1 MN 0 SR- ø1 VM-L ø1.1/ GTV ø1.1/ VL-R-CMAP ø1.1/ MN 0 SR- ø1.1/ VM-L ø1.1/ GTV ø1.1/ VL-R-CMAP ø1.1/ MN 0 /7

FLOW CHART (two steps) D00I0 POS. 1 7 a 1 1 1 1 17 1 1 0 1 Model identification Gas ball valve Flexible connector Gas filter Reducing regulator Orifice flow meter Flow indicator Low pressure gas limit switch High pressure gas limit switch Rapid opening safety solenoid valve Two-step safety solenoid valve Gas adjuster Flame rod Spark electrode Ignition transformer UV-scanner with housing Metallic burner Low pressure air limit switch Combustion air blower Burner control device Thermocouple Thermoregulator RSO/T ø1 FN ø1 G ø1 SR- ø/ POP-U-S VM-R ø1 VM-R-REG GAF ø1 MN 0 SR- ø1 VM-R-REG GAF ø1.1/ MN 0 SR- ø1.1/ VM-R-REG GAF ø1.1/ MN 0 /7

DIMENSIONS D00E0 Dimensions Burner Burner Burner A mm ø B mm ø C mm ø D mm E mm F mm No. G holes ø H mm ø I mm J mm ø K bsp M mm T mm U mm V mm W mm X mm Y mm Z mm 1 0 1 1. 7 G - 1 70 00 7 0 00 17. 70 1 G - 1.1/ 0 7 0 0 0 0. 11 0 1 G - 1.1/ 0 0 0 NOTE: Based on the company s policy aimed at a continuous improvement on product quality, ESA-PYRONICS reserves the right to bring changes to the technical characteristics of this device without previous notice. Our catalog updated to the latest version is available on our web site www.esapyronics.com and it is possible to download modified documents WARNING: When operating, this combustion system can be dangerous and cause harm to persons or damage to equipment. Every burner must be provided with a protection device that monitors the combustion. The installation, adjustment and maintenance operations should only be performed by trained and qualified personnel. 7/7