FORZA FORNI 601 N Main St, Brewster, NY

Similar documents
Comparative Matrix A Comparison of the NFPA 96 and ICC Standards and Codes with regard to Commercial Kitchen Systems

Revolving Oven Gas Wood Model 140

ENGINEERING EVALUATION

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

CHAPTER 5: EXHAUST SYSTEMS

Direct Vent System Required

CINCINNATI, OH USA

Pellet Vent INSTALLATION INSTRUCTIONS

NFPA 96, 2017 REVIEW SUMMARY

Installation Instructions

APPUZO RANGE HOOD INSTALLATION

Contents Chapters 4 & 5 of the 2012 Michigan Mechanical Code CHAPTER 4, MMC: VENTILATION CHAPTER 5, MMC: EXHAUST SYSTEMS

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

IMC Significant Changes Summary Tier I

CHIMNEYS AND VENTS CHAPTER 8

GAS APPLIANCE LISTING PROGRAM

Public Input No. 16-NFPA [ Section No ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

Combustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

INSTALLATION INSTRUCTIONS

Malm Fireplaces, Inc. 368 Yolanda Avenue, Santa Rosa, CA (707) Fax: (707)

ELECTRONIC FIREPLACE DAMPER

Draft Control D R A F T C O N T R O L G U I D E w w w. f i e l d c o n t r o l s. c o m August 2007

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

INFRARED RADIANT HEATERS

ELECTRONIC FIREPLACE DAMPER

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

CHIMNEY INSTALLATION. Technical Bulletin #1

TJERNLUND PRODUCTS, INC.

2012 INTERNATIONAL FUEL GAS CODE VENTS

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

Are Your Kitchen Hood Filters Compliant?

MECHANICAL EXHAUST VENTILATION SYSTEMS OPERATIONAL GUIDELINES-REVISED 2003

Chapter One Commercial Kitchen Fires

Fire Performance of Translucent Systems

JADE RANGE LOG BROILER MODELS: JLB SERIES

AS Australian Standard. Domestic solid fuel burning appliances Installation. This is a free 6 page sample. Access the full version online.

OPERATION, MAINTENANCE AND PARTS MANUAL

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR GAS FIRED OVEN

2012 International Mechanical Code Significant Changes. About the Significant Changes

RS Chimney Fan for Solid Fuel Applications

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

Owner s Information Manual

SECTION COMMERCIAL-KITCHEN HOODS

POWER VENTER. Model: PVE Series

Fig. 1 - Unit PGD4, PGS4, WPG4

CHAPTER 8 CHIMNEYS AND VENTS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL BURNING EQUIPMENT

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

RS Chimney Fan for Solid Fuel Applications

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER

Errata ANSI Z223.1 National Fuel Gas Code 2015 Edition

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

INFRARED RADIANT TUBE HEATER RSTP15C NATURAL GAS RSTP17C

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Inspection Checklist Mechanical Rough in

2015 & 2012 International Mechanical Code Significant Changes and the PA Uniform Construction Code

INFRARED RADIANT TUBE HEATER

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

ASX7-4-IOM-6 J

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL MECHANICAL CODE 2012 EDITION

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

4.3 Installing Appliances and Interior Vapor Distribution Systems Performance-Based Skills Assessment 2016

INSTALLATION AND SERVICE MANUAL

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Installation Instructions Remote Blowers

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

TRIAD Boiler Systems, Inc Atlantic Drive, Unit 2 West Chicago, IL

INFRARED RADIANT TUBE HEATER

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Technical Datasheet. FHG-S Models 28, and 45. Benefits at a Glance: State Route 22 Salem, NY 12865

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

Vent Supplement Ultra-80, -105, -155, -230 & -310

Owner s Manual THE ELECTRIC

Forno Bravo, LLC. Commercial Professionale and Modena2G Refractory Ovens, Including:

INSTALLER'S GUIDE MASONRY CHIMNEY VENT KIT WARNING: BAYVENT800B 18- CH23D2-05

ASX7-5-IOM-3 J

Installation Requirements for Models:

USER MANUAL Gas Countertop Charbroilers

ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Second Edition. Prepared by the Department of Building and Housing

FIREPLACE SIZES FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VACINITY OF THIS OR ANY OTHER APPLIANCE.

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

OPERATING, INSTALLATION, SERVICE & PARTS MANUAL FOR MEDIUM DUTY GAS CHAR BROILERS MGB-A SERIES

616 Gas Fireplace Insert. Shown with Shadow Box face/panel, Black Painted fireback and Driftwood Log Set.

NFPA 45 NFPA 211 NFPA 1600

COMBUSTION AIR SYSTEM

OWNERS MANUAL LIBERATOR ROCKET HEATER Model: RMH-1

Transcription:

1 Ventilation guide PAVESI OVENS Key Ventilation Facts for Pavesi Ovens All Pavesi Forni SRL ovens are intended to be direct connected to a natural or powered draft chimney system, per NFPA 96. All Pavesi Forni SRL ovens do not require a Type I or Type II hood to be installed above the oven, per manufacturer instructions and NFPA 96. In exhaust systems that are four stories or higher, a listed grease duct system (UL 1978 & UL 103) shall be provided, per NFPA 96, 14.4.2. In exhaust systems that exceed 20 feet vertical or incorporate a 90º elbow, a UL 705 & UL 762 listed rooftop restaurant exhaust fan shall be installed to ensure the exhaust of flue gasses. Pavesi Forni SRL ovens direct connected to draft chimney systems per NFPA 96 and NFPA 211 shall not require fixed automatic fire-extinguishing equipment, neither for the oven appliance nor its exhaust system, per NFPA 96 14.7.2 & 14.7.4. ITALY PAVESI FORNI S.R.L. Via Radidi in Piano 120/c. 41043 Corlo di Formigine (MO) Italy NORTH AMERICA FORZA FORNI 601 N Main St, Brewster, NY 10509 Email: info@forzaforni.com www.forzaforni.com 844-OVEN-INC (844-683-6462) Toll-free in USA (Hablamos Español, Falamos Português) Please contact American representative, Forza Forni, for further inquiries or concerns. DOC#: VGP-1116-1 REVISED FALL 2016. As products continue to improve, ventilation guides may change without notice. Please call Forza Forni for the latest ventilation guide and for further details.

Ventilation guide PAVESI OVENS 2 Direct Connection for pavesi ovens Pavesi Forni SRL intends all ovens to be direct connected to a UL 103 and UL 1978 listed commercial kitchen grease duct in a natural draft chimney system per Chapters 3 and 4 of ANSI/NFPA 211 and Chapter 14 of ANSI/NFPA 96. Pavesi Forni ovens have been investigated by Intertek for direct connection to UL 103 pipe per UL 737 in addition to the commercial gas fired cooking appliance standard, ANSI Z83.11; and the commercial wood fired refractory oven standard, UL 2162 (See attached at the end of this document). In exhaust systems that exceed 20 feet vertical or incorporate a 90 elbow, a UL 705 and UL 762 listed rooftop restaurant exhaust fan should be installed to maintain adequate pressure within the system to exhaust all kitchen vapors. Oven requires approximately 150-200 CFM in make-up air. This shall be supplied via conditioned room air. AHJ: interpretation of the code for natural draft chimney International Mechanical Code: Per the International Mechanical Code, Section 917.1, Cooking appliances that are designed for permanent installation shall be listed, labeled and installed in accordance with the manufacturer s installation instructions.... Solid-fuel-fired ovens shall be listed and labeled in accordance with UL 2162. UL 2162: Per UL 2162 (See attached at the end of this document), This equipment is intended to be installed in accordance with appropriate installation standards, such as the current editions of: ANSI/NFPA 96, Ventilation Control & Fire Protection of Commercial Cooking Operations ANSI/NFPA 211, Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances ANSI/NFPA 70, National Electrical Code (NEC) Uniform Mechanical Code International Mechanical Code International Residential Code Local codes ITALY PAVESI FORNI S.R.L. Via Radidi in Piano 120/c. 41043 Corlo di Formigine (MO) Italy NORTH AMERICA FORZA FORNI 601 N Main St, Brewster, NY 10509 Email: info@forzaforni.com www.forzaforni.com 844-OVEN-INC (844-683-6462) Toll-free in USA (Hablamos Español, Falamos Português) Please contact American representative, Forza Forni, for further inquiries or concerns. DOC#: VGP-1116-1 REVISED FALL 2016. As products continue to improve, ventilation guides may change without notice. Please call Forza Forni for the latest ventilation guide and for further details.

Ventilation guide PAVESI OVENS 3 AHJ: interpretation of the code for natural draft chimney (continued) ANSI/NFPA 96: Per Chapter 14, Solid Fuel Cooking Operations of the NFPA 96 document, 14.1 Venting Application states Venting requirements of solid fuel cooking operations shall be determined in accordance with 14.1.1 through 14.1.7. An examination of following sections provides that a natural draft chimney system direct connected to the exhaust manifold of a Pavesi oven complies with the International Mechanical Code and NFPA 96 document; 14.1.1 Where solid fuel cooking equipment is required by the manufacturer to have a natural draft, the vent shall comply with Section 14.4. - Pavesi Forni ovens are designed for connection to a natural draft chimney system. The oven incorporates an integral hood system which captures all smoke vapors and exhausts them to outside of the building via the UL 1978 listed chimney system attached to the exhaust manifold port located on top of the oven. 14.1.4 Natural draft ventilation systems and powerexhausted ventilation systems shall comply with Sections 14.3, 14.4, and 14.6. - Pavesi Forni ovens can and should be installed in compliance with these Sections. In the instance where a power-exhausted ventilation system is needed, install a fan complying with UL 705 and UL 762 listed roof top restaurant exhaust fan standards. 14.1.5 Where a solid fuel cooking appliance allows effluent to escape from the appliance opening, this opening shall be covered by a hood and an exhaust system that meets the requirements of Sections 14.3, 14.4, and 14.6. - Pavesi Forni ovens do not allow effluent to escape from the appliance opening. All ovens are built with a natural hood constructed from refractory cement at the oven mouth. A natural draft is created by the movement of air due to the positive pressure system created by heat pressure within the oven. 14.1.6 Solid fuel cooking operations shall have spark arresters to minimize the passage of airborne sparks and embers into plenums and ducts. - Pavesi Forni can supply spark arresters to our clients to facilitate this requirement. 14.1.7 Where the solid fuel cooking operation is not located under a hood, a spark arrester shall be provided to minimize the passage of sparks and embers into flues and chimneys. - See response to 14.1.6. ITALY PAVESI FORNI S.R.L. Via Radidi in Piano 120/c. 41043 Corlo di Formigine (MO) Italy NORTH AMERICA FORZA FORNI 601 N Main St, Brewster, NY 10509 Email: info@forzaforni.com www.forzaforni.com 844-OVEN-INC (844-683-6462) Toll-free in USA (Hablamos Español, Falamos Português) Please contact American representative, Forza Forni, for further inquiries or concerns. DOC#: VGP-1116-1 REVISED FALL 2016. As products continue to improve, ventilation guides may change without notice. Please call Forza Forni for the latest ventilation guide and for further details.

Ventilation guide PAVESI OVENS 4 AHJ: FIRE suppression code requirements The following NFPA 96 Sections of Chapter 14 provide that fi x e d a u t o m a t i c fi r e - e x t i n g u i s h i n g e q u i p m e n t a r e n o t required for Pavesi Forni ovens or their exhaust systems when installed per installation instructions outlined in this document: 14.6.1 Exhaust system requirements shall comply with Chapter 8 for hooded operation or shall be installed in accordance with the manufacturer s recommendation for unhooded applications. - Pavesi Forni ovens shall be installed per Chapters 3 and 4 of NFPA 211 and Chapter 14 of NFPA 96 as an unhooded, direct-connected exhaust system. 14.7.2 Where acceptable to the authority having jurisdiction, solid fuel-burning cooking appliances constructed of solid masonry or reinforced Portland or refractory cement concrete and vented in accordance with Chapters 3 and 4 of NFPA 211, Standard for Chimney s Fireplaces, Vents, and Solid Fuel-Burning Appliances, shall not require fixed automatic fire-extinguishing equipment. 14.7.4 Where acceptable to the authority having jurisdiction, solid fuel-burning cooking appliances constructed of solid masonry or reinforced Portland or refractory cement concrete and vented in accordance with Chapters 3 and 4 of NFPA 211, Standard for Chimney s Fireplaces, Vents, and Solid Fuel-Burning Appliances, shall not require automatic fire-extinguishing equipment for the protection of grease removal devices, hoods and duct systems. - Per UL 2162, Pavesi Forni ovens are solid fuel burning wood fired ovens of refractory cement construction. Therefore, automatic fi r e s u p p r e s s i o n e q u i p m e n t i s n o t r e q u i r e d to protect the exhaust system. - Per UL 2162, Pavesi Forni ovens are solid fuel burning wood fired ovens of refractory cement construction. Therefore, automatic fi r e s u p p r e s s i o n e q u i p m e n t i s n o t r e q u i r e d to protect the oven. ITALY PAVESI FORNI S.R.L. Via Radidi in Piano 120/c. 41043 Corlo di Formigine (MO) Italy NORTH AMERICA FORZA FORNI 601 N Main St, Brewster, NY 10509 Email: info@forzaforni.com www.forzaforni.com 844-OVEN-INC (844-683-6462) Toll-free in USA (Hablamos Español, Falamos Português) Please contact American representative, Forza Forni, for further inquiries or concerns. DOC#: VGP-1116-1 REVISED FALL 2016. As products continue to improve, ventilation guides may change without notice. Please call Forza Forni for the latest ventilation guide and for further details.

Listing Constructional Data Report (CDR) 1.0 Reference and Address Report Number 100376855MID-009a Original Issued: 13-Mar-2014 Revised: None Standard(s) UL 2162 Issue: 2014-05-23 Ed: 1 Commercial Wood-Fired Baking Ovens - Refractory Type; ULC/ORD C2162 Issue: 05/01/2013 Ed: 1 Commercial Wood-Fired Baking Ovens - Refractory Type; ANSI Z83.11 Issued: 2007/03/01 Ed: 3 (R2011), (R2012) Gas Food Service Equipment; Addenda A: 2007, Addenda B: 2009; CSA 1.8 Issued: 2007/03/01 Ed:3 (R2011), (R2012) Gas Food Equipment ; Addenda A: 2007 and Addenda B: 2009 Applicant Pavesi Srl Manufacturer Pavesi USA/Fired Up Kitchens, LLC Address Via Radici in Piano 120/C Corlo di Formigine, MO, 41042 Address 357 Adams Street Bedford Hills, NY 10507 Country Contact Phone FAX Email Italy Chiara Caiti 39-59-574569 chiara@pavesiforni.it Country Contact Phone FAX Email USA Peter de Jong 914-733-2845 peter@firedupkitchens.com Page 1 of 48

Report No. 100376855MID-009a Pavesi Srl Page 2 of 48 Issued: 13-Mar-2014 Revised: None 2.0 Product Description Product Brand name Description Wood and Gas baking oven Pavesi The PVP 150 is rectangular in shape with a flat ceiling over the hearth/cooking area and wrapped horizontally with a steel shell. A rotating plate is located offset to the left side of the total hearth area and is used as the entire cooking surface. The top is left open except for ceramic fiber insulation. The ovens are shipped assembled except for the steel stand, which needs to be placed under the oven when installed. The oven must be fully enclosed in finishing materials when installed in the final location to be compliant with the NSF 4 sanitary requirements. Each unit is supplied with a door that can be installed in a partly open position at the top of the door, or the door must be fully removed when in operation. The flue opening is located directly behind the front face of the oven opening. Models Model Similarity Ratings Other Ratings PVP110, PVP130, PVP150, RPM120, RPM140, RPM140x160, RPM140x180, Twister 135, Joy 90 The PVP Series of ovens are similar in design, with the only difference being that they are smaller in size. The RPM Series are similar, but use a dome top; as well as the Twister 135 and Joy 90. All ovens are manufactured from the same materials and use the same electrical and gas components where applicable. 110V, 60Hz Gas input ratings: NG 110,000 Btu/hr (with boost burner) - 45,000 Btu/hr (without boost burner); LP 150,000 Btu/hr (with boost burner) - 80,000 Btu/hr (without boost burner) ED 16.3.15 (1-Jan-13) Mandatory

Report No. 100376855MID-009a Pavesi Srl Page 40 of 48 Issued: 13-Mar-2014 Revised: None 8.0 Test Summary Evaluation Period 11/21/11-4/6/12 Project No. G100598014 Sample Rec. Date 26-Oct-2011 Condition Production Sample ID. Test Location Test Procedure 8431 Murphy Drive, Middleton, WI, 53562 Testing Lab Determination of the result includes consideration of measurement uncertainty from the test equipment and methods. The product was tested as indicated below with results in conformance to the relevant test criteria. UL 737 is referenced for the evaluation of flue temperature for solid fuel applainces connected to a UL 103 Type HT factory built chimney. The following tests were performed: Test Description Test Pressures and Burner Adjustments Combustion Burner Operating Characteristics Automatic Ignition Systems Thermostats Appliances Equipped w/ Induced Draft or Power Burners Rapid Fire Test Normal Operation Fire Test Abnormal Operation Fire Test Flame Spillage Fire Test Glazing Test Thermal Conductivity Test Refractory Material Strength Test Fire Chamber Strength Test Fire Tests UL 2162 ULC/ORD 2162 UL 737 ANSI Z83.11 - CSA 1.8 -- -- -- 2.4 -- -- -- 2.5 -- -- -- 2.6 -- -- -- 2.7 -- -- -- 2.12 -- -- -- 2.17 14 7.5 -- -- 15 7.6 -- -- 16 7.7 -- -- 17 7.8 -- -- 18 7.9 -- -- 19 7.10 -- -- 20 7.11 -- -- 21 7.12 -- -- -- -- 10 -- 8.1 Signatures A representative sample of the product covered by this report has been evaluated and found to comply with the applicable requirements of the standards indicated in Section 1.0. Completed by: Brian Ziegler Reviewed Rick Curkeet Title: Lead Engineer - Hearth Title: Chief Engineer - Building and Hearth Products Signature: Signature: ED 16.3.15 (1-Jan-13) Mandatory

LCJX.GuideInfo - Cooking Appliances, Wood Fired http://database.ul.com/cgi-bin/xyv/template/lisext/1fram... LCJX.GuideInfo Cooking Appliances, Wood Fired View Listings Page Bottom [Heating Appliances] Cooking Appliances, Wood Fired See General Information for Heating Appliances USE AND INSTALLATION This category covers wood-fired cooking appliances, including broilers, ranges, rotisseries, ovens, and the like, as identified in the individual certifications, and intended for use in commercial establishments such as restaurants or for outdoor residential use. These appliances are intended to burn solid wood only, including particulate wood products. Some equipment may be provided with door assemblies, floor protectors and wall shields, adjustable flue-gas dampers, or other optional features as specified in the manufacturer's installation and operating instructions. This equipment is intended to be installed in accordance with appropriate installation standards, such as the current editions of: ANSI/NFPA 96, "Ventilation Control and Fire Protection of Commercial Cooking Operations" ANSI/NFPA 211, "Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances" ANSI/NFPA 70, "National Electrical Code" (NEC) "Uniform Mechanical Code" "International Mechanical Code" "International Residential Code" Local codes Installation is intended to be accomplished by a qualified agency - one who is engaged in, and is responsible for (or is thoroughly familiar with) the installation and operation of solid-fuel-burning heating and/or cooking appliances and who is experienced in such work, familiar with all precautions required, and has complied with all the requirements of the Authority Having Jurisdiction. Installation is intended to be in strict accordance with the markings on the appliance and the manufacturer's installation instructions furnished with the appliance, including (as applicable) markings and instructions pertaining to clearances, types of adjacent surfaces, and proper vent installation. Equipment suitable for built-in installation, side-by-side mounting, or stacking is indicated in the installation instructions. Some equipment is intended to be placed on noncombustible floors, or on combustible floors covered with an insulating, noncombustible floor protector as specified in the manufacturer's installation instructions, ANSI/NFPA 96 and ANSI/NFPA 211. All equipment, but especially equipment that may emit grease-laden vapors, is intended to be provided with an exhaust ventilating system in accordance with ANSI/NFPA 96. See Exhaust Hoods with Exhaust Dampers (YXZR), Exhaust Hoods Without Exhaust Dampers (YYCW) or Grease Ducts for Restaurant Cooking Appliances (YYGQ). Exhaust hood assemblies covered under these categories are intended to be installed in accordance with the manufacturer's installation instructions and ANSI/NFPA 96 and the NEC, as applicable. All exhaust hoods are marked relative to minimum exhaust airflow and maximum supply airflow directed into the hood and/or out the bottom (if provided). Airflow rates are established under draft-free laboratory conditions. Greater exhaust and/or lesser supply airflow rates may be required for each specific installation to obtain complete vapor and smoke removal. FACTORS NOT INVESTIGATED The structural and sanitation properties of the appliance, the toxicity of the products of combustion, the physiological effects on persons consuming food products prepared or served by use of these appliances, the structures in which the appliance may be installed, and the toxicity of coatings have not been investigated. One of the following product identities appears on the product: PRODUCT IDENTITY Wood-fired Equipment Part (for appliances that require additional parts to complete the installation) Wood-fired Oven Other product identities may be used as shown in the individual certifications. See: RELATED PRODUCTS 1 of 2 11/9/15, 10:41 AM

LCJX.GuideInfo - Cooking Appliances, Wood Fired http://database.ul.com/cgi-bin/xyv/template/lisext/1fram... Gas-Wood-fired Food Service Equipment (LGRC) Gas-fired Food Service Equipment (LGQX) Heaters, Ranges, Household, Electric (KRMX) ADDITIONAL INFORMATION For additional information, see Heating Appliances (KTCR) and Heating, Cooling, Ventilating and Cooking Equipment (AAHC). REQUIREMENTS The basic standard used to investigate products in this category is ANSI/UL 2162, "Commercial Wood-Fired Baking Ovens - Refractory Type." UL MARK The Certification Mark of UL on the product is the only method provided by UL to identify products manufactured under its Certification and Follow-Up Service. The Certification Mark for these products includes the UL symbol, the words "CERTIFIED" and "SAFETY," the geographic identifier(s), and a file number. Additional Certification Markings Appliances that require additional parts to complete the installation include the statement: For Use with [Company name] Certified Wood-fired Equipment Parts Alternate UL Mark The Listing Mark of UL on the product is the only method provided by UL to identify products manufactured under its Listing and Follow-Up Service. The Listing Mark for these products includes the UL symbol (as illustrated in the Introduction of this Directory) together with the word "LISTED," a control number, the product name, such as "Wood-fired Oven," or other appropriate product name as shown in the individual Listings, and for appliances that require additional parts to complete the installation, the statement "For Use With [Company Name] Listed Wood-fired Equipment Parts." (+) (+) Each additional part includes the UL symbol (as illustrated in the Introduction of this Directory) together with the word "LISTED," a control number, and the product name "Wood-fired Equipment Part." * * * * * * * * * * * * * * * * * * * * * * * * * UL, in performing its functions in accordance with its objectives, does not assume or undertake to discharge any responsibility of the manufacturer or any other party. UL shall not incur any obligation or liability for any loss, expense or damages, including incidental or consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon this Guide Information. Last Updated on 2014-06-12 Questions? Print this page Terms of Use Page Top 2015 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: " 2015 UL LLC". 2 of 2 11/9/15, 10:41 AM