AMP SUPERSEAL 1.5 SERIES Connectors

Similar documents
AMP SUPERSEAL 1.5 SERIES Connectors

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Z-PACK TinMan 85 ohm Connector Overview

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Introducing SlimSeal SSL Connector

Introducing Hermaphroditic Blade and Receptacle Connector

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

Contacts for Econoseal III Connectors Series.070 (1.8 mm) and Series.250 (6.3 mm)

BUDI-M-SP. Building distributor. Introduction. Seals. Kit content. Accessories. Wrap around cable seals

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

Raychem Link Boxes. Cable Services Limited. Powering the UK

SOLARLOK Interconnection System Installation Manual

Standard and Customized Hand Tool Kits

Specification Status: Released

Specification Status: Released

Gas Discharge Tubes. Features: Benefits: Applications:

Introducing Low Voltage DC Grid Interconnects

Specification Status: Released

Seal Kits for BUDI Enclosures

Quick Reference Guide Barrier Strips

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

Gas Discharge Tubes GTCX25-XXXM-R02 Series

RoHS. AMP SUPERSEAL 1.5 Series Connectors. Ready GLOBAL AUTOMOTIVE DIVISION

Introducing Inverted SMT Thru Board Connector

Specification Status: Released

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR ANDROID

LOW POWER AND SIGNAL APPLICATION GUIDE APPLIANCES /// LOW POWER & SIGNAL APPLICATION GUIDE

Raychem Elastomeric Medium Voltage Push-on and Cold-shrink Applicable Terminations TFTI/TFTO

DATASHEET PolySwitch RKEF Devices

TE Connectivity's AMP NETCONNECT Cable Management

Cable Actuated Sensor Industrial Incremental Encoder Output

Gas Discharge Tubes GTCX28-XXXM-R05 Series

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

Quick Reference Guide: Connectors for Mobile Devices

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR IOS

Introduction. Technical Features

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

Cable Actuated Sensor Industrial User Scalable 4 20mA

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE

Cable Actuated Sensor Industrial User Scalable VDC Output

Energy Division. Accessories for the Installation of Low Voltage & Medium Voltage heat-shrinkable products for the Electrical Power Industry

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

PlanarMag Product Technology

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Standard SPECIFICATIONS FEATURES APPLICATIONS

Introducing Solar Identification Labels

Quick Reference Guide.050 Centerline Micro-MaTch Connector Series

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

ENERGY /// UNDERGROUND DISTRIBUTION UNDERGROUND DISTRIBUTION MEDIUM AND LOW VOLTAGE POWER PRODUCTS

M7100 Pressure Transducer

FC22 Compression Load Cell

DTS SERIES CONNECTORS

PT9150 (Extended Range)

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS

RayClic Connection System

DP86 Constant Voltage with Fitting

.025 Connector Series

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA1 Series, (IEC)

U5300 Industrial Pressure Transducer

Specification Status: Released

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

Pin, Spool & Strain Insulators

PT9420 (Extended Range)

Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution

U5600. Wireless Pressure Transducer SPECIFICATIONS

Printed Circuit Board Connectors

UV-SCE. Ultra-Violet light, Resistant TECHNICAL DATASHEET. Heat Shrink Identification Marker Sleeves

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING.

MSP100 Pressure Transducer

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.


Stainless Steel Cable Ties

Sub psi SPECIFICATIONS

M5200 Industrial Pressure Transducer

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

The Importance of Pressure Sensors in HVACR Systems

D5100 Industrial Differential Pressure Transducer

Reliable solutions for electrified railway systems

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

MSP340 Pressure Transducer

TE CONNECTIVITY S CYLINDER HEAD WIRING SOLUTIONS FOR INDUSTRIAL & COMMERCIAL VEHICLES

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

QUADRAX D-SUB CONNECTORS

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

FC23 Compression Load Cell

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Transcription:

Introduction Tyco Electronics has developed the MP SUPERSEL 1.5 SERIES Connector family to meet the increasing requirements for reliability and water proofness. MP SUPERSEL 1.5 SERIES Connector exceed the requirements prescribed by IP 67 according IEC 60529 and DIN 40050-9 standards and has its application in the automotive, agriculture and industrial machinery. For sensor application the MP SUPERSEL 1.5 SERIES Connector system is qualified as well. dvantages Compact system minimizes packaging requirements Sealing reliability proven under harsh conditions Designed for ease of manual harness assembly, engine mounting and under hood environments pplications Wire-to-Wire (1.5 mm) and ECU applications, under hood or any location where sealing is required Suitable for automotive, truck, bus, or off-road vehicles ll specifications subject to change. Consult Tyco Electronics for latest specifications. 28-1

Receptacle Contacts Contact Material: CuZn (Tab) CuSn (Receptacle) Contact Finish: tin plated 16.5 Current Carrying Capacity: 14 max. 1.6 Wire Size Range: 0.35 2.5 mm 2 Insulation Diameter: 1.2 3.3 mm FLR Extraction Tool: Part No. 9-1579007-1 8.5 Product Specification: 108-20090 2.5 pplication Specification: 114-20045 1.5 mm Receptacle Contacts Wire Size Range (mm 2 ) Insulation Diameter FLK FLR Material and Finish s Strip Loose- pplicator Hand Tool Form Piece 0.35 0.50 1.45 2.20 1.2 1.6 CuSn, tin plated 282403-1 14,000 183035-1 5,000 x-1528347-x 2031676-1 0.75 1.50 2.40 3.35 1.7 2.4 CuSn, tin plated 282110-1 14,000 183025-1 5,000 x-1528018-x 2031676-1 1.5 2.5 3.15 3.80 2.2 3.3 CuSn, tin plated 282466-1 14,000 x-1426361-x Note: ll part numbers are RoHS and ELV compliant. ) The pre- and suffix for the applicators depends on the applied termination equipment. 28-2 ll specifications subject to change. Consult Tyco Electronics for latest specifications.

Tab Contacts Contact Material: CuZn (Tab) CuSn (Receptacle) Contact Finish: tin plated, gold plated 22.7 Current Carrying Capacity: 14 max. 1.5 Wire Size Range: 0.35 2.5 mm 2 Insulation Diameter: 1.2 3.3 mm FLR Extraction Tool: Part No. 9-1579007-1 Product Specification: 108-20090 pplication Specification: 114-20045 0.8 10.4 1.5 mm Tab Contacts Wire Size Range (mm 2 ) Insulation Diameter FLK FLR Material and Finish s Strip Loose- pplicator Hand Tool Form Piece CuZn, tin plated 282404-1 16,000 183036-1 5,000 0.35 0.50 1.45 2.20 1.2 1.6 x-1528199-x 2031676-1 CuZn, gold plated 282404-3 16,000 CuZn, tin plated 282109-1 16,000 183024-1 5,000 0.75 1.50 2.40 3.35 1.7 2.4 x-1528463-x 2031676-1 CuZn, gold plated 282109-3 16,000 1.5 2.5 3.15 3.80 2.2 3.3 CuZn, tin plated 282465-1 16,000 x-1528200-x Note: ll part numbers are RoHS and ELV compliant. ) The pre- and suffix for the applicators depends on the applied termination equipment. ll specifications subject to change. Consult Tyco Electronics for latest specifications. 28-3

Single Wire Seals and Cavity Plugs Made from silicon rubber material For insulation diameters of 1.2 3.3 mm Loose-piece wire seals are crimped simultaneously with the contacts 6.1 5.9 7.8 Single Wire Seals and Cavity Plugs Insulation Diameter FLK FLR Color 1.2 1.6 Green 281934-4 50,000 1.7 2.4 Yellow 281934-2 50,000 2.5 3.3 Red 281934-3 50,000 Cavity Plugs Red 282081-1 50,000 28-4 ll specifications subject to change. Consult Tyco Electronics for latest specifications.

Plug Housings Plug Housings Utilizes Receptacle Contacts Pitch 6.0 Housing Material: Polyamide 6.6 glass-filled Black (other colors available) Orange (closed cavities) Secondary Lock: Polyamide 6.6 glass-filled Red 19.0 28.0 Sealing: Silicon Rubber Yellow ( ) with secondary lock closed 19.0 28.0 Plug Housings Dimension 1 9.3 282079-2 3,000 2 15.3 282080-1 1,600 3 21.3 282087-1 1,300 4 27.3 282088-1 1,000 5 33.3 282089-1 0,500 6 39.3 282090-1 0,400 Plug Housings with Closed Cavities Dimension 2 15.3 1745025-1 1,600 4 27.3 1745101-1 1,000 5 33.3 1745103-1 0,500 ll specifications subject to change. Consult Tyco Electronics for latest specifications. 28-5

Cap Housings Cap Housings Utilizes Tab Contacts Pitch 6.0 lso suitable for panel mount application (see detail X ). Locking clip not manufactured by Tyco Electronics. 13.8 16.3 42.0 Detail X Housing Material: Polyamide 6.6 glass-filled Black (other colors available) Orange (closed cavities) Secondary Lock: Polyamide 6.6 glass-filled Red 42.0 16.3 Extraction Tool for Secondary Lock of Cap Housing: Part No. 785084-1 Insertion Tool for Secondary Lock of Cap Housing: Part No. 785061-1 for 1 and 2 positions Part No. 785061-2 for 3 6 positions Cap Housings Dimension 1 13.8 282103-1 2,200 2 19.8 282104-1 1,500 3 25.8 282105-1 1,200 4 31.8 282106-1 0,500 5 37.8 282107-1 0,700 6 43.8 282108-1 0,550 Cap Housings with Closed Cavities Dimension 2 19.8 1745022-1 1,500 3 25.8 1745020-1 1,200 5 37.8 1745018-1 0,700 28-6 ll specifications subject to change. Consult Tyco Electronics for latest specifications.

Rubber Boots Rubber Boots Connector Housing Description Rubber Boot Color 282080-1 Plug Housing 282104-1 Cap Housing 282087-1 Plug Housing 282105-1 Cap Housing 2 880810-1 Black 1,500 3 880811-2 Black 1,000 57.0 D 11,0 B C Dimensional Data Boot Wires Dimensions B C D 880810-1 2 12.5 20.5 4.6 5.0 880811-2 3 17.5 25.5 4.6 5.0 493581-1 4 21.0 34.5 7.0 ) Different Style, see customer drawing. ll specifications subject to change. Consult Tyco Electronics for latest specifications. 28-7

Numerical Index Page Page Page 183024-1 28-3 183025-1 28-2 183035-1 28-2 183036-1 28-3 281934-2 28-4 281934-3 28-4 281934-4 28-4 282079-2 28-5 282080-1 28-5, 28-7 282081-1 28-4 282087-1 28-5, 28-7 282088-1 28-5 282089-1 28-5 282090-1 28-5 282103-1 28-6 282104-1 28-6, 28-7 282105-1 28-6, 28-7 282106-1 28-6 282107-1 28-6 282108-1 28-6 282109-1 28-3 282109-3 28-3 282110-1 28-2 282403-1 28-2 282404-1 28-3 282404-3 28-3 282465-1 28-3 282466-1 28-2 493581-1 28-7 785061-1 28-6 785061-2 28-6 785084-1 28-6 880810-1 28-7 880811-2 28-7 9-1579007-1 28-2, 28-3 1745018-1 28-6 1745020-1 28-6 1745022-1 28-6 1745025-1 28-5 1745101-1 28-5 1745103-1 28-5 2031676-1 28-2, 28-3 Disclaimer While Tyco Electronics and its affiliates referenced herein have made every reasonable effort to ensure the accuracy of the information contained in this catalog, Tyco Electronics cannot assure that this information is error free. For this reason, Tyco Electronics does not make any representation or offer any guarantee that such information is accurate, correct, reliable or current. Tyco Electronics reserves the right to make any adjustments to the information at any time. Tyco Electronics expressly disclaims any implied warranty regarding the information contained herein, including, but not limited to, the implied warranties of merchantability or fitness for a particular purpose. Tyco Electronics only obligations are those stated in Tyco Electronics Standard Terms and Conditions of Sale. Tyco Electronics will in no case be liable for any incidental, indirect or consequential damages arising from or in connection with, including, but not limited to, the sale, resale, use or misuse of its products. Users should rely on their own judgment to evaluate the suitability of a product for a certain purpose and test each product for its intended application. In case of any potential ambiguities or questions, please don t hesitate to contact us for clarification. www.tycoelectronics.com www.tycoelectronics.com/automotive MP, MP SUPERSEL 1.5 SERIES, TE (Logo) and Tyco Electronics are trademarks of the Tyco Electronics Group of Companies and its Licensors. 28-8 ll specifications subject to change. Consult Tyco Electronics for latest specifications.