Focus. Trust. Initiative.

Similar documents
Technical Information HXV - HRV Ventilation

Technical Information HCV - HCH Demand-controlled home ventilation

Technical Information. Ventilation

Technical information 2. Swimming Pool Air Management

DC Air Conditioner 4000/6000 Service manual Rev. 2.0 en

AIR CONDITIONING & VENTILATION PLANTS

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Topvex SR03, SR04, SR06 Compact Air Handling Unit

MOBILE HEATING AND COOLING

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

TECHNICAL INFORMATION HCC 2 Home ventilation unit for suspended ceiling

Original instructions JSNY7 Magnetic switch

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

Turbo. Service Instructions

Installation manual Washer extractor

electronics Protection

SITESTAR CABINET DESCRIPTION

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Panel Mounted Heat Exchangers by Dantherm, Inc.

TECHNICAL INFORMATION DanX XD & DanX HP Swimming pool air management

G Installation manual Solitude - dmev unit

Product Data Sheet 4114 N/17HH-218. The engineer's choice

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Topvex SF02-SF12 Air Handling Unit

Installation guide for J4 Junction Box for R4 AIS Transponder System

ISCG90SS _03 ISCG90SS

TECHNICAL INFORMATION HCV 4 - HCV 5 - HCH 5 - HCH 8 Demand-controlled home ventilation

COOLflow 4E PRODUCT RANGE

Liebert HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

Pool dehumidification for comfort and wellness

Instructions for the fan motor control system, SILVER C

Original instructions Sense7-series Non-contact coded safety switch

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

HEAT RECOVERY AIR HANDLING UNIT

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

The Straight Way K Sileo Series

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Installation and Operation Manual

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

ISIS SAFETY SYSTEM Installation guide

DEMAND-CONTROLLED HOME VENTILATION

Edition 8, From serial no Publ. no OM 5030, Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL)

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

Instructions for the BASIC BCRW Fan, Sizes General

MOBILE HEATING AND COOLING

Room thermostat with Auto Timer, Option External Input

AP-EH500-L/RQA9837. Installation Guide

Kitchen Appliance Lift INSTRUCTION MANUAL

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Control Panel Basics Volume 1

Installation manual. Tumble dryers T4250, T4350. Selecta Control

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Snifter ATEX22 VERSION. User Manual. Distributor

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Room thermostat with Auto Timer, Option External Input

TTV 4500 / TTV 4500 HP / TTV 7000

KK70 Silent. Installation and Operating Instructions L V001

WIO200 Water In Oil measuring instrument

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. External Sounder & Strobe Unit

USER MANUAL AND TECHNICAL MANUAL

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

RE-PR3-E-27 3-Phase Panel Mount 27kW

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Edition 8 From serial no Publ. no OM 5030NHD; Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL)

Domestic & Commercial Fans

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Product Catalog. DCHC Horizontal Concealed Chilled Water Fan Coil with DCBL Motor Airflow: 180~2380 m 3 /h

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Earth-Rite II PLUS Static Earthing System

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Datasheet - AZM 161SK-12/12RK-024

TECHNICAL INFORMATION DanX Swimming Pool Air Management

Height-adjustable Unit

Caution: The fans must not be used in bath or shower enclosures.

Technical data Chimney fans, controllers and accessories in systems for gas fireplaces, stoves and single non-modulating gas boilers

CONTENT: VEX308 Decentralised ventilation VEX308

Transcription:

Focus. Trust. Initiative.

2005 layout

DFC 350 and 450 Service manual EN No. 840121 rev. 1.3 09.01.2012

Der tages forbehold for trykfejl og ændringer Dantherm can accept no responsibility for possible errors and changes Irrtümer und Änderungen vorbehalten Dantherm n assume aucune responsabilité pour erreurs et modifications éventuelles

840121 Version 1.3 09.01.2012 Overview Introduction This is the service manual for the Displacement Free Cooling unit DFC 350 & 450. The DCF 350-450 unit is usually shipped including a control unit. This control unit, TKS 3000A EC, ACUE 3000 or FAC 48, is covered in a separate manual. Table of content The Service Manual covers the following main topics: Topic See page General information 4 General principle for DFC units 5 Parts and function 6 How to mount the DFC 350 and DFC 450 7 Technical data DFC 350 10 Technical data DFC 450 11 Technical data DFC 350 and 450 12 Capacity and data diagrams 13 Dimensions 15 Installation alternatives 18 Wiring diagram ACUE 3000 19 Wiring diagram TKS 3000A EC 20 Wiring diagram FAC 48 21 Preventive maintenance 22 Spare parts list 23 3

General information Introduction This section provides general information about the unit and this Service Manual. Target group The target group for this Service Manual is the technicians who install, maintain and repair the unit. Warning It is the responsibility of the operator to read and understand this service manual and other information provided and to use the correct operating procedures. The product should only be operated by qualified (trained) personnel. Failure to do so can result in personal injury or equipment damage. Read the entire manual before the initial start-up of the product. It is important to know the correct operating procedures for the product and all safety precautions to prevent the possibility of property damage and/or personal injury. Products The Service Manual cover the following products: Name Type No. DFC 350 299763 DFC 450 299745 Copyright Copying of this service manual, or part of it, is not allowed without written permission from Dantherm Air Handling A/S. Reservations The service manual is subject to changes without notice. CE-Declaration of Conformity Dantherm Air Handling A/S, Marienlystvej 65, DK7800 Skive hereby declare that the unit are in conformity with the following directives: 2006/95/EG Low Voltage Directive including 93/68/EEC where required 86/336 EEC EMC Directive including 92/31/EEC and 93/68/EEC 98/37 EG Machine Directive The product is manufactured with components which follow the application standards for Low Voltage Directive and in case of norms for EMC in EU countries. Recycling The unit is designed to last for many years. When the time comes for the unit to be recycled, the unit should be recycled according to national rules and procedures to protect the environment. 4

840121 Version 1.3 09.01.2012 DFC General principle for DFC units General A DFC (Displacement Free Cooling) unit supplies the cold outdoor air through a diffusor filter with very low velocity. This will make a dune of cold air at the floor and up to a height of 1,6 meter in the shelter. The temperature at the ceiling will be relatively high. The idea is to remove more heat with lower air volume in order to save power consumption of the fan. This is only possible if a large temperature difference between supply air and air out of the shelter can be achieved. Efficiency The efficiency of the DFC unit depends very much on the circulation of the internal air circulation in the telecom equipment and in the shelter. It is therefore very necessary to do a thorough test of the airflows in the shelter before initiating a bigger roll out. Illustration The illustration below shows the DFC and some external parts unit mounted in a container: GT2 DAMPER ST2 ACTIVE COOLING UNIT AC ROOM SENSOR GT1 SUPPLY 48V DC / 230V AC CONTROLLER GP OUTDOOR TEMP SENSOR LOW DELTA-T UP TO 1,6m HEATER RADIOBASE SITE Parts DFC FLOW This table describes the different part (from left to right) in the illustration above: Part Outdoor Temp sensor DFC unit GP Controller Heater Supply 48V DC/230 V AC Room sensor GT1 Active cooling unit Damper Description Measures the outdoor temperature (NTC resistor) The unit including bag filter and air inlet hood with compact filter Supply to the unit from power source Climate unit controller TKS3000EC, ACUE3000 or others External electrical heater Supply to the controller and the DFC Measures the indoor temperature (NTC resistor) Existing airconditioner (often split unit) Electrical damper allowing warm air to leave the shelter Continued overleaf 5

Parts and function Introduction The DFC units have a simple but very robust design. The parts are shown below. Illustration This drawing shows the parts of the DFC unit. It includes a fan and a filter guard Filter guard Fan Bag filter Parts This table describes the parts in the illustration: Part Filter guard Fan Bag filter Description Measures the pressure on both sides of the filter. When the pressure drop exceeds 150 Pascal (factory setting) the build in switch which is connected to the controller will open and cause an alarm. The fan is a centrifugal fan either 48 V DC or 230 V AC. See technical data for further information. The Bag filter is either filter class F5 or F6, see technical data for further information. 6

840121 Version 1.3 09.01.2012 How to Mount the DFC 350 or DFC 450 Procedure Follow these steps to mount the DFC 350 or DFC 450: Step Action 1 Make a Ø245mm hole in the shelter wall about 1900 mm above the floor. 2 Demount the front cover of the unit by removing the 3 fluted grip knobs. 3 Hold the unit in position and fasten it to the wall with minimum 4 screws. 4 Slide the filter into place and remount the front cover. DFC 350 1 3 2 4 DFC 450 1 3 2 4 f 7

How to Mount the DFC 350 or DFC 450, continued Air inlet hood Put sealing rubber on the flanges of the hood, hold it in position above the inlet hole and fasten it to the wall. Exhaust damper Cut out an exhaust opening W: 1000xH: 210mm above the door (when possible). Hold the motorized damper in position and fasten it to the wall. Continued overleaf 8

840121 Version 1.3 09.01.2012 How to Mount the DFC 350 or DFC 450, continued Exhaust hood Put sealing rubber on the flanges of the exhaust hood. Hold it in position and fasten it to the wall. Ground Connect the DFC 450 to ground by using the nut market with ground symbol. For more wiring information, please see section Wiring Diagram. Electrical connection For electrical connection of the unit see the Service Manual for the specific controller that you are using, or see Wiring Diagram at the end of this manual. 9

Technical data DFC 350 Introduction This Free Cooling unit is very compact, quiet and economic due to the Displacement Free Cooling system. In this product the EC-fan signal is reduced to 5V to get the optimized performance. Air flow and sound This table shows the technical data for airflow and sound pressure: Parameter 48V DC 230V AC Max air flow 514 m 3 /h 514 m 3 /h Max air flow 143 l/s 143 l/s Free cooling capacity at Δt=5 C 3 kw 3 kw Max power consumption 40 W 35 W Sound pressure at 5m from shelter 36 db(a) 34 db(a) Sound pressure at 10m from shelter 31 db(a) 31 db(a) Cabinet This table shows the specifications for the cabinet: Specification Designation DFC 350 Weight Controller included 10 kg Metal sheet material Aluzinc AZ150 0,8-1,5 mm Fan motor This table shows the data for the fan motor: Voltage version 48V DC 230V AC Voltage nominal 48V DC 230V AC Current 2,3 A 0,9 A Max power consumption at standard settings 40 Watt 35 Watt Speed 1500 rpm 1500 rpm Filter This table shows the data for the filter: Specification Filter data Type Bag filter Filter Class F6 Total Area 1,4 m 2 Recommended filter monitor settings 150 Pa 10

840121 Version 1.3 09.01.2012 Technical data DFC 350 Air flow and sound This table shows the technical data for airflow and sound pressure: Voltage version 48V DC 230V AC Max air flow 1100 m 3 /h 1100 m 3 /h Max air flow 306 l/s 306 l/s Free cooling capacity at Δt=5 C 5 kw 5 kw Max power consumption 40 W 61 W Sound pressure at 5m from shelter 36 db(a) 34 db(a) Sound pressure at 10m from shelter 31 db(a) 31 db(a) Cabinet Data and dimensions of the cabinet are shown in the following table: Specification Designation DFC 450 Weight Controller excluded 13 kg Metal sheet material Aluzinc AZ150 0,8-1,5 mm Fan motor Data of the fan motor is shown in the following table: Voltage version 48V DC 230V AC Voltage nominal 48V DC 230V AC Current 2,3 A 1,1 A Max power consumption 40 W 54 W Speed 1200 rpm 1200 rpm Filter In the table below the data of the filter are specified: Specification Filter data Filter data Type Bag filter Filter Class F5 F6 Total Area 2 m 2 Recommende filter monitor setting 100 Pa 150 Pa Electrical heater, This table shows the voltage and power consumption of the electrical heater (optional): Power, Voltage Specification 1300 W, 230 V AC Value 11

Technical data DFC 350 and 450 Controls The table below show the specification for the 2 controllers for the DFC unit: Specification 48V DC 230V DC Standard control units (See separate manuals) Special control units (See separate manuals) Indoor temperature sensor Outdoor temperature sensor Enclosure IP65 DIN rail mounting Enclosure IP65 ACUE 3000 FAC 48 TKS 3000 EC RG-TD5 RG-TD5 RG-TD5 UG-TD5 (optional) UG-TD5 (optional) UG-TD5 (optional) Filter monitor JDW5 (optional) JDW5 (optional) JDW5 (optional) 12

840121 Version 1.3 09.01.2012 Airflow [m3/h] Cooling performance [W] Pressure drop [Pa] Airflow [m3/h] Airflow [m3/h] Cooling performance [W] Capacity and data diagrams Performance The diagram below shows data for DFC 350: DFC 350 Performance & Power Consumption 1000 900 800 Fan working range 15% to 50% 5000 4500 4000 700 600 500 400 3500 3000 2500 2000 Power conption DFC 450 [W] Air flow m3/h Cooling capacity (kw @ t=5 C) 300 200 100 0 114 75 5 11 20,0 30 48 20% 30% 40% 50% 60% 70% 100% 1500 1000 500 0 Cooling performance is calculated from outdoor temperature and indside temperature in 1,6m height % fan speed Airflow & Pressure drop The diagram below shows data for DFC 350: DFC 350 Airflow & Pressure drop 180 160 140 120 100 80 60 40 20 0 20% 30% 40% 50% 60% 70% 100% Fan % speed 1000 900 800 700 600 500 400 300 200 100 0 Pressure drop Filter (Pa) Air flow m3/h Performance The diagram below shows data for DFC 450: DFC 450 Performance & Power Consumption 1600 6000 1400 1200 1000 800 600 400 200 0 Fan working range 15% to 50% 8 15 25,0 37 61,7 104 20% 30% 40% 50% 70% 100% 5000 4000 3000 2000 1000 0 Power conption DFC 450 [W] Air flow m3/h Cooling capacity (kw @ t=5 C) Cooling performance is calculated from outdoor temperature and indside temperature in 1,6m height % fan speed Continued overleaf 13

Pressure drop [Pa] Airflow [m3/h] Capacity and data diagrams, continued Airflow & Pressure drop The diagram below shows data for DFC 450: DFC 450 Airflow & Pressure drop 120 100 80 60 40 20 1600 1400 1200 1000 800 600 400 200 Pressure drop Filter (Pa) Air flow m3/h 0 20% 30% 40% 50% 70% 100% Fan % speed 0 14

840121 Version 1.3 09.01.2012 Dimensions Illustration DFC 350 The drawings below illustrate the dimensions of the DFC 350. HOLE CUT OUT DIMENSION: Ø245 Continued overleaf 15

Dimensions, continued Illustration DFC 450 The drawings below illustrate the dimensions of the DFC 450. HOLE CUT OUT DIMENSION: Ø305 Continued overleaf 16

840121 Version 1.3 09.01.2012 Dimensions, continued External accessories Exhaust air rain hood FC1100x220: 940-30205576 Motorized Exhaust air damper SP1000x211 48VDC: 940-02130724 230V DC: 940-02130230 Air inlet hood with net: 940-60299654 HOLE CUT OUT DIMEN- SIONS (WxH): 1000x210mm 17

Installation alternatives Introduction The pictures below shows the three ways the Displacement Free Cooling unit can be mounted and still make filter exchange easy. There are three different lids, of which only one should be opened to take out and replace the bag filter. Front service Left and right service 18

840121 Version 1.3 09.01.2012 Fan control Supply voltage Line 230VAC, 50 Hz Fuse 10 A Battery Supply 48 VDC 10 A Fuse Battery Supply Unit Free Cooling unit FAN 48 VDC FILTER MONITOR +48V GND 0-10V An 2 3 Yellow/Green Brown Blue + Brown - Blue Brown White 3 2 x 1,5 Brown Blue 1 3 x 1,5 Red 1 1 Blue 2 2 White Yellow 4 3 JUNCTION BOX Option: 6 5 Option: Indoor temp. Sensor (RG-TD5A) Heater Max 1300W Option: Main Power AC-unit PE N L L N PE White Brown PE N L 3 4 5 6 2 2 x 0,25 Yellow/Green Brown Blue GP1 White Brown Outdoor temp. Sensor (UG-TD5A) Brown 2 x 0,25 White 1 2 3 1 2 3 A2 A1 White Brown PE L N PE EN EL PE C11 C12 +48 +48-48 -48 Y2 COM Y1 COM Tc1 Tc2 Tc3 Tc4 OT COM RT ACUE 3000 600-23671410 ACUE 3000 DFC 101112 NO NC D11 D12 D13 D21 D22 D23 SLX COM Fir COM Fil RS-232 COM COM FiA COM FaA COM LTA COM HTA 1 2 3 5 6 3 x 0,5 GP1 1 2 3 Filter Alarm Output Fan Alarm Output Low Temp Alarm Output High Temp Alarm Output 1 Black Junction box 2 Red 3 White Option Inlet and exhaust Air damper LM24 KTA Wiring diagram ACUE 3000 19

20 Wiring diagram TKS 3000A EC

840121 Version 1.3 09.01.2012 CONTROLLER Wiring diagram FAC 48 Red 1 FAC 48 D1 Brown Red 2 Battery Supply 48 VDC + Brown 3 10 A Fuse Battery Supply Unit - Blue 2 x 1,5 Free Cooling Unit FAN 48 VDC +48V GND 0-10V An White 2 FILTER Brown MONITOR 3 Brown Blue Blue White Yellow FILE: FAC 48 DFC 101112 2 4 3 6 5 JUNCTION BOX PE N L HEATER AC START CIRCUIT HIGH TEMP ALARM (NC/NO ADJUSTABLE) LOW TEMP ALARM (NC/NO ADJUSTABLE) FAN ALARM (NC/NO ADJUSTABLE) FILTER ALARM (NC/NO ADJUSTABLE) OPTION OUTDOOR TEMPERATURE SENSOR (UG-TD5A) ROOM TEMPERATURE SENSOR (RG-TD5A) OPTION 12V DC 12V DC 5 7 2 2x0.25 1 2 3 4 +P -P E+ E- C+ C- A1 A1 A2 A2 A3 A3 A4 A4 Y2 C Y1 C OT C RT C T1 T2 T3 T4 C RC-232 D2 D3 D4 D5 D6 S1 C FR C FL C LD C TR C Brown White Green 5 6 FEMALE CONNECTOR White Green FIRE DETECTION ALARM IF BROKEN FILTER MONITOR ALARM 230V AC LINE DETECTION ALARM IF BROKEN BUTTON FOR TIMER DATA COMMUNICATION MALE CONNECTOR Black 1 White 3 OPTION EXHAUST DAMPER MOTOR (LM 24 KTE) 21

Preventive maintenance Introduction The unit needs preventive maintenance with specific intervals to avoid breakdown or inefficient operation. It is important to notice that interval between maintenance can vary depending on the specific environment. Caution! Switch off both the DC and AC supply before working on the unit! Make sure that all work has been performed before switching on the power again. Service function Timer The control unit has a service function to ensure better indoor climate for 20 minutes during the presence of service technicians. To activate the service function, push one step up from the main menu to find Timer. Now press Enter. The control unit will now count down from 20 minutes and after that go back to normal operation. Interval Dantherm Air Handling AB recommends that intervals between preventive maintenance do not exceed 1 year. It is also our recommendation that the site and unit is examined closely during the first preventive maintenance to determine whether the interval is too long. We recommend that preventive maintenance visits are carried out during spring. Condition for warranty The factory warranty is only valid if documented preventive maintenance has been carried out with an interval of maximum 1 year. The documentation should be in form of a written log. Leaving the site Before leaving the site, make sure there are no alarms! Recommended approach Follow these steps to carry out preventive maintenance on the unit: Step Action 1 Make sure that the power to the unit is safely switched off. 2 Remove the worn-out filter and clean the unit carefully. 3 Clean the dampers with regards to function and tightness. 4 Clean the fan and check that the mounting is OK. 5 Check and clean the air intake and exhaust accessories. 6 Insert the new filter carefully into the unit. 7 Close the unit and make sure that the service is completed correctly. 8 Turn on the power to the unit. 9 Run the Self test according to the separate manual for the controller. 22

840121 Version 1.3 09.01.2012 Spare parts list Spare parts DCF 350 only This table shows the spare parts for DFC 350: Spare part Type Part number Bag filter Filter class F5 299821 Bag filter Filter class F6 067335 Fan 48V DC EC, Centrifugal fan, 48V DC 067738 Fan 230V AC EC, Centrifugal fan, 230V AC 840060 Spare parts DCF 450 only This table shows the spare parts for DFC 450: Spare part Type Part number Bag filter Filter class F5 299749 Bag filter Filter class F6 840058 Fan 48V DC EC, Centrifugal fan, 48V DC 067739 Fan 230V AC EC, Centrifugal fan, 230V AC 840061 Control parts This table shows the various control parts, sensors and filter monitor for both the DFC 350 and DFC 450. Check the label on the controller for identification: Spare part Type Part number Control Unit 48V ACUE 3000 48V DC 840012 Control Unit 230V TKS 3000A EC 230V AC 840014 Alt. control Unit 48 FAC 48 48V DC 840015 Indoor temp. sensor RG-TD5A 840017 Alt. Indoor temp. sensor SG-TD5A, 5m cable 840018 Outdoor temp. sensor UG-TD5A 840019 Filter monitor 840020 Other parts This table shows the available damper actuators and heater: Spare part Type Part number Damper actuator for 48V controller LM24A KTE 840021 Damper actuator for 230V controller LM230A 840022 External heater 1300/550W, 230V 840023 23

accessories... 17 air flow... 10; 11 airflow... 5 area... 10 bag filter... 6 cabinet... 10 conformity... 4 control unit... 12 cooling capacity... 10; 11 copyright... 4 dimension... 15 DIN rail... 12 directive... 4 efficiency... 5 electrical connection... 9 enclosure... 12 exhaust... 8 filter class... 6; 11 filter Class... 10 filter guard... 6 filter monitor... 12 front cover... 7 function... 6 ground... 9 hole... 7 indoor temperature sensor... 12 installation... 18 interval... 22 maintenance... 22 motorized damper... 8 mount... 7 outdoor temperature sensor... 12 performance... 13 power consumption... 10; 11 pressure drop... 13 preventive... 22 principle... 5 recycling... 4 sealing... 8; 9 service... 18 service function timer... 22 shelter... 5 sound pressure... 10; 11 spare parts... 23 speed... 10; 11 table of content... 3 voltage... 10; 11 warning... 4 warranty... 22 weight... 10; 11 wiring diagram ACUE 3000... 19 wiring diagram FAC 48... 21 wiring diagram TKS 3000A EC... 20 24

2005 layout

Comfortable surroundings in any climate Since 1958 Dantherm Air Handling has developed and produced climate control and air handling solutions that ensure optimum conditions for people and sensitive equipment alike. No climate is too extreme for us to handle from the bitter cold at the North and South Poles to the searing heat of the Sahara. Our core business areas are dehumidification, heating, air conditioning, ventilation and electronics cooling. Innovative, durable and cost-efficient products have secured us a position as a leading global manufacturer of stationary and mobile climate control units. And we are forever pursuing new techniques that will improve our solutions and ultimately your projects. Our Head Office is located in Denmark, and we have companies in Denmark, Norway, Sweden, the United Kingdom, the United States and China, with an extensive European dealer network. Dantherm Air Handling is part of the Dantherm A/S group. HEAD OFFICE COMPANIES Dantherm Air Handling Holding A/S Marienlystvej 65 DK-7800 Skive Denmark Tel.: +45 9614 3700 Fax: +45 9614 3800 E-mail: dantherm.dk@dantherm.com www.dantherm-air-handling.com DENMARK Dantherm Air Handling A/S Marienlystvej 65 DK-7800 Skive Denmark Tel.: +45 9614 3700 Fax: +45 9614 3800 E-mail: dantherm.dk@dantherm.com www.dantherm-air-handling.dk NORWAY Dantherm Air Handling AS Løkkeåsveien 26 N-3138 Skallestad Norway Tel: +47 33 35 16 00 Fax: +47 33 38 51 91 E-mail: dantherm.no@dantherm.com www.dantherm-air-handling.no CHINA Dantherm Air Handling (Suzhou) Co., Ltd. Bldg. # 9, No. 855 Zhu Jiang Rd. Suzhou New District, Jiangsu 215219 Suzhou China Tel.: +86 512 6667 8500 Fax.: +86 512 6667 8501 E-mail: dantherm.cn@dantherm.com www.dantherm-air-handling.com.cn UNITED KINGDOM Dantherm Air Handling Ltd. 12 Windmill Business Park Windmill Road Clevedon North Somerset BS21 6SR United Kingdom Tel.: +44 (0) 1275 876851 Fax: +44 (0) 1275 343086 E-mail: dantherm.co.uk@dantherm.com www.dantherm-air-handling.com USA Dantherm Air Handling Inc. 110 Corporate Drive, Suite K Spartanburg, SC 29303 USA Tel.: +1 864 595 9800 Fax: +1 864 595 9810 E-mail: dantherm.usa@dantherm.com www.dantherm-air-handling.us SWEDEN Dantherm Air Handling AB Virkesgatan 5 SE-614 31 Söderköping Sweden Tel.: +46 (0) 121-130 40 Fax: +46 (0) 121-133 70 E-mail: infose@dantherm.com www.dantherm-air-handling.se 10.2010 THORVIG TRYK, Skive