NYC STEM Summer Institute: Climate To Go! Infrared detection of carbon dioxide

Similar documents
PHYSICS FORM 5 TRANSFER OF THERMAL ENERGY

SIMRAD GD10PE IR GAS DETECTOR

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

People living in the desert need to wear special clothing in order for them to keep cool.

Chemistry Instrumental Analysis Lecture 4. Chem 4631

Heat Transfer: Conduction. Heat Transfer: Conduction

Fire Detection System: An Overview

Fourth Edition HEAT TRANSFER AND CHANGE OF PHASE

SPECTRAL INSTRUMENTATION

THERMAL PROCESSING THEORY

An FT-NIR Primer. NR800-A-006

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

Passive Standoff FTIR Detectors as Transducers. Background From radiation to information

Leveraging Thermal Imaging for Gas Detection

SIMRAD GD10 IR GAS DETECTOR

Let There Be Light. Grade Level/Range: 4-8

Conceptual Physics Fundamentals

ISLAMAYA ENGLISH SCHOOL

Thermal Energy. Conduction, Convection, and Radiation. Before You Read. Read to Learn. Conduction. section 2

Pyroelectric Infrared Sensor PIR

Infrared Carbon Dioxide Sensor Module CM1107-Dual Beam

INTERNATIONAL JOURNAL OF RESEARCH GRANTHAALAYAH A knowledge Repository

E11 Tests of trace gas concentration multicomponent. monitoring system

Science 7 Chapter 6 Section 1

Heat. Energy. Lesson 2. Unit 2: Water! From Waves to Weather

EEM 451 Industrial Control Systems Sensors and Actuators-II. Dept. of Electrical-Electronics Eng. Anadolu University, Turkey

Unit THE NATURE OF HEAT

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C

February 18, What is heat? Touch each image to see how the water molecules react.

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

Making a Carousel Lantern. Grade 7 Activity Plan

Some Demonstration Experiments: Effects of Air Motion, Evaporation, and Pressure Changes on Temperature

Fundamentals of Far-infrared

INFRARED HEATERS APPLICATIONS INFRARED HEATING

University of California Santa Barbara Department of Chemistry and Biochemistry Optical Characterization Facility. Safe operations manual

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Chemistry Instrumental Analysis Lecture 14. Chem 4631

Specifications Wavelength Range: 190 nm to 800 nm continuous

The table gives information about some ways of reducing the energy consumption in a house. Installation cost in. Fit a new hot water boiler

Infrared Carbon Dioxide Sensor Module CM1106SL

Thermal Energy Study Guide

Introduction to the Fusion TOC Analyzer

EVAPORATION NEEDS ENERGY

Infrared Moisture Balance (FD-660)

CATALYTIC EMITTER - An old idea in new clothes

Level 6 Using Physics: Investigate how physics knowledge is used in a technological application.

Laser Distance Sensor Type M Analog-Output

Lecture 7 Water in the Atmosphere

liquid heating The density of the liquid changes as its temperature increases. This causes energy to be transferred throughout the liquid.

Challenges in industrial point sensing- NDIR John Saffell

Water in the air experiment discussion - Where did the water on the outside of the cups come from? How do you know?

Here is a summary of what you will learn in this section: Heat is transmitted through the environment by conduction, convection, and radiation.

Variable Temperature Microprobe Systems

Solar Matters III Teacher Page

PHYSICS OF FOIL HEAT GAIN/LOSS IN BUILDINGS

The design of the human body infrared thermometer

Transfer of Thermal Energy

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

? Radiation. Radiation. How does heat energy get from the Sun to the Earth?

Heat Transfer. Heat. Thermal Energy: Heat 1

The new generation of Multi-Gas measurement. Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control

Conduction, Convection, and Radiation Lab Page 1 of 5

scale analysis to micro scale imaging-ftir. State of the art and future perspectives.

Minutes with Lamp On

IGCSE PHYSICS GRADE 11 TERM 1 ASSESSMENT BOOKLET

Propagation loss in optical fibers (01/29/2016)

Air Quality Sensors. Particle Matter, CO 2, Humidity, Temperature and Dust Products. OEM Sensor Components for Air Quality and Environmental Control

Reduce Reuse Recycle STEVE TRASH SCIENCE VIDEO Grade 1-5

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

Key Features. General Description

Meltdown: Heat Conduction in Different Materials

Final Report FIREMAN

Broadening IR applications through using spectral filters

'7 Infrared Drying and Curing Systems w4

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Global Warming and the Hydrological Cycle

Distributed Temperature Sensing

NanoReady. Micro UV-Vis Spectrophotometer

PHY1H (JAN09PHY1H01) General Certifi cate of Secondary Education January Unit Physics P1. PHYSICS Unit Physics P1.

Radiation and Laser Safety

Well Insulated Houses: Helping to Stay Warm in Winter and Cool in Summer

Physics. Mr Rishi Gopie THERMAL ENERGY TRANSFER

Technical specifications of FT-IR Spectrometer

Rooftop Gardens. Why is there a garden on the roof of Chicago s City Hall? 2 nd Grade Science ILS 11A, 11B, 12B, 12E, 12F, 13A.

infrared 99A89AFD5537ECF7A7EAEA8F6E03A447 Infrared 1 / 6

When both switches are on, the heater works at the high power setting. What is the power of the heater when it is switched to the high power setting?

How SWIR Imaging contributes to the optimization of automatic quality control in the food industry

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

VS Glow Is the Newest and Most Technically Advanced Infrared Heater that Generates Instantaneous Heat

Sensor : IRA-S210ST01 Lens : IML-0685/0688 Pyro Electric Infrared Sensor Fresnel Lens Features Applications Excellent S/N Intrusion Detectors

THERMODYNAMICS PREPARED BY DW & JD

LIMITS OF CARBON DIOXIDE IN CAUSING GLOBAL WARMING

Smart Fire Prevention

Station Four Guide thermal energy and Motion Energy

Drying Laboratory Methods Drying Parameter Characterization from Small Size Samples

Transcription:

NYC STEM Summer Institute: Climate To Go! Infrared detection of carbon dioxide Standards NGSS PS3A: Definitions of Energy NGSS PS4B: Electromagnetic Radiation NGSS ESS2D: Weather and Climate NGSS ESS3D: Global Climate Change Equipment IR thermometer Mug warmer/hot plate CO2 meter Juice bottle cuvette Small water dish (2-4oz) Sodium bicarbonate tablets (Alka- Seltzer) Frame wood or LEGO for assembling experiment Clock/timer/smartphone Why? Atmospheric gasses are invisible, thus difficult to study, yet they play a critical role in maintaining the health and viability of human and natural communities. The interactions between energy and atmospheric gasses keep our planet habitable and maintain long- term global temperatures. Carbon dioxide although a trace gas in the atmosphere is an important greenhouse gas because it absorbs IR energy emitted by the Earth. What? In this activity we will measure the absorption of infrared (IR) energy by carbon dioxide gas. Two pieces of instrumentation will allow us to study something we cannot see; (1) an inexpensive IR thermometer and (2) a CO2 meter. The learning goals for this experiment are: Build an apparatus to detect carbon dioxide gas Describe the importance of energy absorbance Explain the response of the IR detector How? We will use a mug warmer to shine a beam of IR energy through a plastic cuvette to an IR detector the IR thermometer. We will introduce CO2 gas into the cuvette and use the CO2 meter and IR detector to monitor the changes that take place through the course of the experiment. This experiment is designed to use inexpensive and home- made components. In Part 1 we will build and assemble the pieces. 1

ABOUT IR DETECTORS All objects emit energy. The kind of energy emitted (its wavelength or frequency) is a function of the surface temperature of the object. Very hot objects (like stars) emit energy across a range of wavelengths that spans from very short x- rays to very long radio waves, but the peak of the emission spectrum is in the visible range (Figure 1: note that the peak of the emission spectrum moves to longer wavelengths at lower temperatures). For a cooler object like a human body, the peak of the emission spectrum is in the infrared range. An instrument that can measure wavelength can convert that measurement to temperature. We make use of IR detectors to calculate temperature routinely a standard ear thermometer does exactly that. A child with a fever emits energy at a shorter wavelength than one without. In this experiment we will use an IR detector that automatically calculates temperature. For our purpose this handy feature adds a bit of complication we aren t really interested in temperature at all we want to know if the energy is reaching the detector or if it gets absorbed in between the source and the detector. Because our IR source has a constant temperature, a drop in the reported value on our IR detector is a measure of energy absorbance. PART 1 - BUILD THE EXPERIMENTAL COMPONENTS Make a plastic juice bottle cuvette. The cuvette will hold the sample of CO2 gas. The cuvette should have flat, parallel sides constructed from an IR- transparent material. The photos in this handout show a 32- oz plastic lemonade bottle with two square windows cut from the sides and covered with food- grade plastic wrap. The square windows, when covered with the plastic wrap, create the two flat parallel sides of the cuvette. Other containers could be used (a milk carton would probably work almost as well). Plastic wrap is a great IR- transparent window. We will also need to cut a hole square or circular in the bottom of the cuvette so that we can place it over a small water dish. 2

Construct a frame to hold the experiment. The frame will hold the mug warmer in a vertical position, and should elevate the IR thermometer so that it targets the surface of the mug warmer. A frame will also allow the students to reproduce their experiment using nearly- identical dimensions, thus reducing a source of error and uncertainty. The frame shown in the photo here is made from LEGO bricks. A platform holds the IR thermometer (sideways) and orthogonal to the windows in the cuvette. The brace for the mug warmer is 14cm behind the cuvette. Figure 2: Experimental setup. CO2 GAS SOURCE The source of CO2 gas for this experiment will be sodium bicarbonate antacid tablets dissolved in water. The sodium bicarbonate (NaHCO3) dissociates to form carbonic acid (H2CO3) which in turn dissociates to release CO2 gas: NaHCO3 + H2O => Na+ + H2CO3 + OH- H2CO3 => H2O + CO2 PART 2 ASSEMBLE & PREPARE THE EXPERIMENTAL APPARATUS This experiment is designed to detect changes that occur when CO2 gas is introduced into the sample cuvette. Thus the equipment should be set up and allowed to stabilize prior to running the experiment. In particular, a typical mug warmer needs about 30 minutes to achieve its stable temperature, and some types of CO2 meters also benefit from being turned on and left running for 10 minutes or so prior to recording data. The IR detector needs no special prep, although make sure it is set to read in the units you will use (C/F). Place the mug warmer in a vertical position in the frame and turn it on. Fill the small water dish with water and set it in the frame; place the cuvette over the dish. Position the CO2 meter in/on the bottle opening on the top of the cuvette. Turn the CO2 meter on. If you will record the CO2 data with a computer connect it to the meter and launch the logging software. Position the IR detector on its platform. Use a rubber band around the detector and platform to hold it in place. Get ready to keep track of run time of the experiment, using either a watch, smartphone, or the logging software on the computer. 3

Data for time, IR, and CO2 can be recorded by hand, entered into a spreadsheet, or logged via a computer interface (the IR detectors described here do not have an automatic logging option). PART 3 - RUN THE EXPERIMENT Run the experiment in blank mode without adding the sodium bicarbonate tablets for one minute. Record data at a convenient time interval (every 15 or 30 seconds is good). At one minute, lift the cuvette enough to add two sodium bicarbonate tablets to the water dish. Immediately replace the cuvette. Continue recording data for 8 additional minutes. Graph the results. Time (min) IR (C) CO2 (ppm) 0 0.5 1 Add two NaHCO3 tablets. 1.5 2 2.5 3 3.5 4 4.5 5 Figure 3: Sample results IR Temp (C) left axis CO2 (ppm) right axis 75 70 65 60 55 50 45 40 35 30 IR Temp & CO2 IR Temp CO2 (ppm) 15000 0 0 60 120 180 240 300 Time (sec) 40000 35000 30000 25000 20000 10000 5000 Experimental results using two different CO2 meters. Left, Vernier GoDirect CO2 Gas probe. Right, TIM12 Desktop CO2 Logger. Both experiments are run for 5 minutes. The Vernier probe effectively seals the cuvette thus CO2 levels do not decrease during the experiment. The TIM12 IR Temp (C) left axis CO2 (ppm) right axis 70 65 60 55 50 45 40 35 30 IR Temp & CO2 0 1 2 3 4 5 Time (min) IR Temp CO2 (ppm) 2000 1500 1000 500 0 4

allows CO2 in the cuvette to mix with outside air. Both experiments show strong absorption of IR energy when CO2 is added to the cuvette. DISCUSSION: WHAT IS HAPPENING HERE? The vertical surface of the mug warmer shines a beam of IR energy through the cuvette to the lens of the IR detector which records its intensity. The first data points prior to introducing CO2 gas into the experiment show the behavior of the IR detector in its baseline configuration when it is monitoring the IR energy passing through the air in the cuvette. The sodium bicarbonate tablets react with water to exsolve CO2 gas into the atmosphere of the cuvette. When CO2 is added the intensity measured by the IR detector decreases. Like a cloud passing over the sun, the CO2 gas is interfering with the beam of IR light. Carbon dioxide is a very strong absorber of infrared energy. The CO2 molecules absorb energy at specific wavelengths, which cause the molecules to vibrate at a higher amplitude than normal. For example, infrared energy with a wavelength of 15 micrometers (which the 400K mug warmer emits) is absorbed by the CO2. This absorption will cause the linear CO2 molecule to bend (or flap ). In the cuvette we observe that absorption as the decreased intensity measured by the IR detector. In Earth s atmosphere the increased vibrational energy increases collisions with other molecules, thus raising the temperature of the atmosphere. The CO2 molecule eventually re- emits the absorbed energy, which can continue to be re- absorbed and re- emitted until it finally escapes to space. With more CO2 in the atmosphere it is more difficult for IR energy emitted by the Earth to escape directly to space, therefore we see increased temperatures in the atmosphere. Figure 4: Emission spectra for different temperatures. Earth = 300K, mug warmer = 400K. Energy from both the Earth and the mug warmer cause a bending vibration in CO2 molecules. 5

References and Resources TED Ed video on molecular vibration (including CO2): https://www.youtube.com/watch?v=b0ibxg0hnok Black Body Radiation entry on Wikipedia: https://en.wikipedia.org/wiki/black- body_radiation Equipment Vernier GoDirect CO2 Gas probe: https://www.vernier.com/products/sensors/co2- sensors/gdx- co2/ TIM12 Desktop CO2 logger: https://www.co2meter.com/collections/desktop/products/tim12- desktop- co2- rh- t- monitor- data- logger Extech 14252 Infrared thermometer: http://www.extech.com/display/?id=14252 Etekcity Lasergrip 800 Infrared thermometer: https://www.etekcity.com/product/100040 Contact Info Dr. Alexandra Moore Senior Education Associate Paleontological Research Institution moore@priweb.org 6