Intelligent Addressable Fire Alarm System Company Profile The Company established in 2003, is manufacturing security system devices with the brand name DEKON Security Technologies for the exclusivity of M/s. Techno Fire & Safety Co, L.L.C. (TTFS) to be marketed in UAE & Middle East. Since 2007 the company manufactures Fire Alarm Systems and allied accessories. All their products including sensors, detectors, devices, software, hardware and related Systems have been developed in fully assimilated R&D and manufactured conforming to international standards with SMD Technology. DEKON has earned a range of national and international certificates conforming to standards such as CE & TSE Certifications and all these products have been approved by Applus Laboratories & ENAC Certifications. All the designs of DEKON Ltd., have been conceived by incorporating functional designs like Quality Functional Deployment (QFD), Capturing Customer Requirement at the earliest stages of Design, Robust design and User friendly installation. The above lead to fast service (an improved Mean Time to Restore, MTTR) during their functional duration & it is so formulated that the vital elements of a fire detection system are fully compatible with each other and guarantee the reliability engineering goals of DEKON Security Technologies. DEKON Head Office is Located in UK, Istanbul, Turkey with strategically developed branch in Longgang Shenzhen. EN54-13 Certified 4 Techno Fire & Safety Co. LLC
Schematic Diagram DD501 S0240R-A PL002 DD512 IM201 AA504/LE505 FACP/ EXTENSION MODULE 2CX2.5mm2 / RS485 INTERFACE CABLE AA504/LE505 FACP/ EXTENSION MODULE BM050 CP211 IO808 DD512 GS290 CO401 SR340F OM301 LOOP-01 TYPICAL LOOP-02 TYPICAL LOOP-03 TYPICAL LOOP-04 TYPICAL 2CX2.5mm2 / RS485 INTERFACE CABLE Max. No of Devices 250/Loop. B C 2CX2.5mm2 / RS485 INTERFACE CABLE LOOP-01 LOOP-02 TYPICAL LOOP-03 TYPICAL LOOP-04 TYPICAL DD501 CP312 SA340 DD501 CP312 SA340 Max. No of Devices 250/Loop. DD512 GS290 CO401 PL002 DD501/ SB604 S0240R-A SB604 DD512 BM050 SR340F IO808 CP211 DD512 GS290 CO401 DD501 CP312 SA340 OM213 CP211 DD501/ SB604 S0240R-A PL002 SR340F S0240R-A PL002 A D LE505 LOOPS : 1-4 DD512 GS290 CO401 LE505 16 Loop System Configuration for 4000 Devices. UPCOMING MODEL AA504/LE505 FACP/ EXTENSION MODULE LOOP-01 TYPICAL LOOP-02 TYPICAL LOOP-03 TYPICAL LOOP-04 TYPICAL Max. No of Devices 250/Loop. 2CX2.5mm2 / RS485 INTERFACE CABLE AA504/LE505 FACP/ EXTENSION MODULE DD501 CP312 SA340 DD501/SB604 S0240R-A PL002 LOOP-01 LOOP-02 TYPICAL Max. No of LOOP-03 TYPICAL LOOP-04 TYPICAL Devices 250/Loop. 2CX2.5mm2 / RS485 INTERFACE CABLE PC NETWORK CABLE AA45R REPEATER PANEL AA504NT AA504NT PRINTER MODULE PRA5P Make your living spaces Secure Techno Fire & Safety Co. LLC 5
Intelligent Addressable Fire Alarm System AA402 Electronic Addressable Intelligent AA504 Electronic Addressable Intelligent AA45R Repeater Panel Onboard one loop,250 nodes per loop, Metal Case, l28 x 64 Graphic LCD Display, 16 zone Leds, Programmable zone Contents, Alarm and Error Relay Outputs, Supervise Siren Output, 3 Open Collector Programmable Outputs, Event Log, Turkish and English Language, RS485 Serial Interface, Real Time Clock, EN54-2/4 Compatible. Dimensions: 34.5 x 36 x l0.5 cm 1-4 Loops, 250-1000 Node Capacity, AA45R Repeater Connection, By L.E505 Loop Extension Module can be extended to 16 loops Metal Case, l28x64 Graphic LCD Display, 16 Zone Led \ 250 Zones, Programmable Zone Contents, Alarm and Error Relay Outputs, supervise Siren Output, 3 Open Collector Outputs, Event l.og, Turkish and English Language, RS485 Serial Interface, Real time Clock, EN54-2/4 Compatible. Dimensions: 34.5 x 36 x 10.5 cm Compatible with AA504 FACPs, One to one simulation as panel, Very thin design, Metal Case, 128x64 Graphic LCD Display, 16 zone Leds, RS485 Interface, No need extra card or device, Direct connection to FACP, Dimensions: 25.5 x 32. 5 x 3 cm EN 54-13, System Certified. LE505 Loop Extension Module LK401 Loop Card PRA5P Printer Module Connection AA504 FACP extends 4 loop by module, 4 slots for LK401 Loop Card, Can be connected upto 3 modules per AA504, Selectable by DipSwitch 3 Loop groups (4 loops 3 modules) (5-8/9-l2/13-16 Loop Selection), RS485 interface, Internal power supply, 2 x 7Ah Battery Backup, LK401 Loop Card / Cards not included Dimensions: 34.5 X 36 X 10.5 cm One loop 250 node capacity, Short Circuit Protection, Indication Leds, ESD Protection, For use with AA504 FACP, and loop Extension module LE505, 32 pin connector, Loop Extension Card. RS485 Interface with M 504 FACP, Dot Matrix output. Boyutlar: 36.5 x 17.5 x 10.5 cm Weight: 200 gms ER100 Configuration and Programming Software EP200 Supervision and Control Software USB485 USB-RS232 Converter Configuration and Programming of AA5xx Series FACPs, Turkish and English Language, RS485 serial Interface Configuration, Programming. Supervison and Control of AA5xx Series FACPs, Turkish and English Language, RS485 Serial Interface USB - RS485 interface, USB Cable, RX TX leds. 6 Techno Fire & Safety Co. LLC
Intelligent Addressable Fire Alarm System DD501 Addressable Intelligent Optical Smoke Detector ED501 Addressable Optical Smoke Detector DD502 Addressable Heat Detector Dual indicator with lightway, By intelligent property and self calibration and eliminates false alarms, Indicator output, ENGINE-7 Compatible. Diameter: 10 cm Height: 4.4 cm Dual indicator with lightway, By intelligent property self calibration and eliminates false alarms, Indicator output. EN54-7 Compatible. Diameter: 10 cm Height: 4.4 cm Two indication leds, Indicator Output, EN54-5 & En54-13 Compatible. Diameter: 10 cm Height: 4.4 cm DD503 Addressable Combined Optical Smoke and Heat Detector DD-T Detector Base GS290 Addressable Gas Detector Combined Constant Temperature and Optical Smoke Perception, Two indication leds, Indicator Output, EN54-5/7 Compatible. Diameter: 10 cm Height: 4.4 cm Detector Base for DD and ED series devices LPG and Natural Gas Detection, Optically Isolated, Alarm and Fault Supervision, Test Button, Lightway indication, Addressable Loop Connection, EN-50194-1 Compatible. Dimensions: 8.8 x 8.8 x 4.8 cm CO401 Addressable Carbon-monoxide Detector VD202 Automatic PSTN Voice Dialer BM100 Beam Detector Carbon-monoxide Gas Detection, Optically Isolated, Alarm and Fault Supervision,Test Button, Lightway indication, Addressable Loop Connection EN-50291-1 Compatible. Dimensions: 8.8 x 8.8 x 4.8 cm 8 different call numbers, 20 seconds voice record, onboard buttons,continuous / Trigger call, 12Vdc Dimensions: 6 x 7.5 cm 10-100 perception distance,transmitter / Receiver, Reflector Included, User friendly Installation, Laser Pointer for easy adjustment, Selectable two different threshold level, Alarm and Error Relays Dimensions: 129 x 80 x 80 mm Techno Fire & Safety Co. LLC 7
Intelligent Addressable Fire Alarm System SB508 Sounder Detector Base SB604 Sounder Detector Base SB604F Sounder Detector Base with Flasher Sounder Detector Base for DD and ED series devices. Microprocessor controlled, No need extra cable, If alarm perceived by the detector sounds 1 sec every 3 seconds. Diameter: 10 cm Height: 6 mm Sounder Detector Base for DD and ED series devices. Microprocessor controlled, 87dB Sound Level, White ABS material. Diameter: 12 cm Hight: 4.3 cm Sounder Detector Base for DD and ED series devices. Microprocessor controlled, 87dB Sound Level, 4 animated Leds, Red Transparent ABS material. Diameter: 12 cm Hight: 4.3 cm SB6040 Flasher Detector Base CP211 Addressable Manual Call Point Resettable CP312 Addressable Manual Call Point Resettable Flasher Detector Base for DD and ED series devices, 4 animated Leds, Red Transparent ABS material. Diameter: 12 cm Hight: 4.3 cm Animated Lightway indication, resettable by key, Prevention Cover, EN54-11 Compatible. Dimensions: 9 x 9 x 2.7cm Light indication, resettable by key, with embedded Isolator, EN54-11 Compatible. can be used as Conventional or Switch Dimensions: 8.5 x 8.5 x 5.5 cm IM201 Addressable Supervised Input Module OM301 Addressable Output Module IO404 Addressable 4 in 1 Input/Output Module Supervised Input; Open circuit, Short circuit, Alarm Condition Perception, Small Size, Easy installation, EN54-18 Compatible. Dimensions: 6 X 4 x 2 cm Single Channel output Module, SSR Relay Output, Small Size, Easy instal Installation, EN54-18 Compatible. Dimensions: 6 x 4 x 2 cm Dip Switch selectable. Can be Input Module, Conventional Input Module, Output Module and Siren Supervised Output Module. When working as Output Module Normally Closed and Normally Open Contact Connectors for Relay, Optical Isolation, Easy Installation, EN54-18 Compatible. Dimensions: 9 x 7 x 6 cm 8 Techno Fire & Safety Co. LLC
Intelligent Addressable Fire Alarm System D-SA340 Loop Powered Addressable Indoor Sounder With Flasher D-SA340A Loop Powered Addressable Indoor Sounder SO240R Outdoor Fire Alarm Siren with Flasher Conventional Indoor Sounder, Red Colour, 4 Led Animated, sound Pressure Level 95dBA at 1 meter, Alarm Current < 4mA, EN54-3 Certified. Fits DD-T Detector base Diameter: 10cm Height: 6.5 cm Addressable Indoor Sounder, Red Colour, Sound Pressure Level 95dBA at 1 meter, Alarm Current <4mA, EN54-3 Compatible, 300mA NiMh Battery, Fits DD-T Detector base Diameter: 10 cm Height: 6.5 cm Outdoor Use IP65, High sound pressure Level 120dBA at 1 meter, Battery inside, EN54-3 Compatible. Dimensions: 30 x 24 x 7 cm PL001 Parallel Indicator Led PL002 Parallel Indicator Lamp S02 Water Leakage Detector For use with Conventional and Addressable Detectors, Normally transparent, in alarm Red Led indication. Diameter: 8 cm Height: 1.8 cm For use with Conventional and Addressable Detectors, in Alarm Wide Red Illumination. Diameter: 8 cm Height: 1.8 cm Water Leakage Detector, Current Limitting, Vertical, Horizontal and Cable Extension Installation, Buzzer Indication, Normally Open/Close Selectable Relay Output, Two colour Led Indication. Dimensions: 6 x 4 x 2 cm Battery 12V/7Ah (B.B Battery) KB208 1 x 2 x 0.8 FIre Cable KB215 1 x 2 x 1.5 FIre Cable KB408 2 x 2 x 0.8 mm 2 Fire Cable KB415 1 x 2 x 1.5 Fire Cable VRLA Chargeable Sealed Lead Acid Battery Dimensions: 6 x 4 x 2 cm Techno Fire & Safety Co. LLC 9
Conventional Fire Alarm System KA316 16 Zone Conventional K8 8 Zone Conventional K4 4 Zone Conventional 16 Zones, 2x16 Alfanumeric LCD Display, Alarm Short circuit and Open circuit indication, Plastic front Case, Metal Body, User friendly installation and programming, Day / Night Mode Non-volatile System Clock, 1 Supervised Siren Out, Alarm and Error relay Outputs, 24V Auxiliary Power Outputs,EN54-2/4 Compatible. Dimensions: 29 x 33.5 x 10.5 cm 8 Zones, 2x16 Alfanumeric LCD Display, Alarm, Short circuit and Open-circuit indication, Plastic front case, Metal Body, User friendly installation and programming, Day/Night Mode, Non-volatile System Clock, 1 Supervised Siren Out, Alarm and Error relay Outputs, 24V Auxiliary Power Outputs, EN54-2/4 Compatible. Dimensions: 29 x 33.5 x 10.5 cm 4 Zones, 2x16 Alfanumeric LCD Display, Alarm, Short-circuit and Open-circuit indication, Plastic front Case, Metal Body, User friendly installation and programming, Day/Night Mode, Non-volatile System Clock, 1 Supervised Siren Out, Alarm and Error relay Outputs, 24V Auxiliary Power Outputs, EN54-2/4 Compatible. Dimensions: 29 x 33.5 x 10.5 cm K8A 8 Zone Conventional K4A 4 Zone Conventional PS120 Power Supply 8 zone, Separate Alarm, Short-circuit, Open circuit and Bypass Leds for each zone, Keylock for Access Level 1, Plastic case, User-friendly installation and programming, Day/Night Mode, RS232 Interface, 1 Supervised Siren Out,3 Open Collector Outputs. Alarm and Error relay Outputs, 12V and 24V Auxiliary Power Outputs, EN54-2/4 Compatible, Dimensions: 26 x 31 x 9 cm 4 Zone, Separate Alarm, Shortcirtuit, Open circuit and Bypass Leds for each zone, Keylock for Access Level 1, Plastic case, Userfriendly installation and programming. Day/Night Mode, RS232 Interface, 1 supervised Siren out, 3 Open Collector Outputs, Alarm and Error relay Outputs, 12V and 24V Auxiliary Power Outputs, EN54-2/4 Compatible, Dimensions: 26 x 31 x 9 cm EN54-4 Power Supply, 2x7Ah Battery, Ready, Ac Loss, Battery Error, Earth Fault Indicator Leds. Faulty Battery Indication, Battery Short Protection, Deep Discharge prevention, 100W Continuous Power. Dimensions: 29 x 33.5 x 10.5cm DK230 Conventional Optical Smoke Detector EK230 Conventional Optical Smoke Detector DK231 Conventional Heat Detector Dual indicator with lightway, By intelligent property self calibration and eliminates false alarms, indicator output, EN54-7/ EN54-13 Compatible. Diameter: 10cm Height: 4.4 cm Dual indicator with lightway, By intelligent property self calibration and eliminates false alarms, Indicator output, EN54-7 Compatible. Diameter: 10 cm Height: 4.4cm Two indication leds, Indicator Output, EN54-5 Compatible. Diameter: 10cm Height: 4.4cm 10 Techno Fire & Safety Co. LLC
Conventional Fire Alarm System DC232 Conventional Combined Optical Smoke and Heat Detector CO401K Relay Out Carbon-monoxide Detector GS290K Gas Detector Combined Constant Temperature and Optical Smoke Perception, Two indication leds, Indicator Output, EN54-5/7 Compatible. Diameter: 10 cm Height: 4.4 cm Carbon-monoxide Gas Detection, Optically Isolated, Alarm and Fault Supervision, Test Button, Lightway indication, Normally Closed and Normally Open Contact Connectors for Relay. Dimensions: 9 x 9 x 3.8 cm LPG and Natural Gas Detection, Alarm and Fault Supervision, Test Button, Lightway indication, Normally Closed and Normally Open Contact Connectors for Relay EN50194-1 Compatible. Dimensions: 8.8 x 8.8 x 4.8 cm BM050/BM100 Beam Detector SR408 Indoor Sounder SR408F lndoor Sounder with Flasher 10-50/100 Perception distance, Transmitter / Receiver, Reflector Included, User friendly Installation, Laser Pointer for easy adjustment, Selectable two different threshold level, Alarm and Error Relays Dimensions: 129 x 80 x 84 mm Conventional Indoor Sounder, Red Colour, Sound Pressure Level 92dBA at 1meter, Alarm Current < 32mA, EN54-3 Compatible, Fits DD-T Detector base Diameter: 10 cm Height 6.5 cm Conventional Indoor Sounder, Red Transparent Colour, Sound Pressure Level 92dBA at 1 meter, Alarm Current <36 ma, EN54-3 Compatible, Fits DD-T Detector base Diameter: 10 cm Height: 6.5 cm CK180 Resettable Manual Call Point CK312 Resettable Manual Call Point SR280 Indoor Sounder with Flasher Animated Lightway indication, resettable by key, Prevention Cover, EN54-11 Compatible. Dimensions: 9 x 9 x 2.7 cm Resettable by key, EN54-11 Compatible. Dimensions: 8.5 x 8.5 x 5.5 cm Indoor Sounder, Red Colour, Sound Pressure Level 85dBA at 1meter, Alarm Current <50mA, EN54-3 Compatible Dimensions: 9 x 9 x 3,4 cm Techno Fire & Safety Co. LLC 11