APOGEE Open Processor with Airflow Dataguard Driver: CCT DX Unit

Similar documents
Multistack Modbus Driver: Standard Unit

APOGEE Open Processor with McQuay Microtech Driver: European Reciprocating Chiller (CR1)

APOGEE Open Processor with McQuay Microtech Driver: Series 200 Centrifugal Chiller

McQuay BACnet Solution: Microtech II Water-Cooled Centrifugal Chiller Controller (WSC, WDC, WPV)

Metasys Integrator Airflow Application

Honeywell Modbus Solution: 7800 Series Burner Controller through S7810M Modbus Module

McQuay Microtech III BACnet MS/TP Application 4181 Point Map

McQuay BACnet Solution: Microtech II Self-contained Unit Controller with Discharge Air Control (DAC)

7.1 Data Guard 5.0 variable list

LONWORKS Solution for Orion PT-LON-Link

Data Aire DAP TM III. Metasys Control Points

Modbus Point Map. for the. Data Aire DAP-II

Pneumercator Driver: TMS 2000/3000

Data Aire DAP TM III. LonWorks Protocol Integration Information

NetworkAIR AFX. Operation and Maintenance AFX65 AFX18

Data Aire DAP TM III. LonWorks Protocol Integration Information

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

POWERS CONTROLS Pneumatic Thermostat Covers

Predator Controller Hardware Family

APC APPLICATION NOTE #119

Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Introduction. What is the W2W Open controller?

MICROPROCESSOR CONTROLLER OPERATION AND MAINTENANCE MANUAL February 1, 2002

Lennox Climatic 50 and BMS Modbus, Trend or BACnet.

POWERS Pneumatic Thermostat Covers

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

NA G µair CONNECT 2

Marvel S MICROPROCESSOR CONTROLLER. Installation, Operation and Maintenance Manual Effective October 2018 DISCONTINUED. For Reference Only

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

Marvel J MICROPROCESSOR CONTROLLER

Computer Room Air-Conditioning 60 Hz. Technical Data

The system shall be described in the following specification as manufactured by Schneider Electric

MRMS Multi-Room Monitoring Station

Table of Contents. W2W Open

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

DX-9100 Applications from Engineering Services

Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later

DAP III Zone Master User s Guide

TEC Controller Single Compressor Heat Pump with Reversing Valve Control, Application Application Note Building Technologies

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual

BAC-4000 Series AppStat

HVAC Mandatory Provisions Part II, Page 1

Your Home. Jacco & Assoc.

TEC Controller Unit Conditioner - Two-Pipe Fan Coil Cooling or Heating, Application Application Note Building Technologies

SC SpotCool. 1 to 3 Tons. R407c & R410a. 2 x 4 Packaged & Split. Spot-Cooler & Ducted. eair above-the-ceiling air conditioners (ASC-L22)

Series PS6, Vertical Floor-Mount Units

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems

The system shall be described in the following specification as manufactured by Schneider Electric

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits R-407C

THE ULTIMATE ROOFTOP SOLUTION

COMcheck Software Version Mechanical Compliance Certificate

QPM21 Series Duct CO 2 and Air Quality Sensors

Barrier. ED /07/09 Release to production R.P. A ECO N DATE DESCRIPTION OF CHANGE CHG By ISSUE TITLE TC842B1007 AE PRODUCT SPECIFICATION

Contents. APC NetworkAIR CW. CW 020 C= Chilled Water BA= /3/60 D= Downflow. Capacity (kw) Configuration Voltage Air Pattern

ATC32U03 igate Communicating, Programmable Thermostat

Precision Air-Conditioning Units 60 Hz. Technical Data

± 3% or better at 40%RH and 23ºC [73ºF] 0.8 mm 2 [18 AWG] minimum

Service Step by Step Trouble-Shooting Check-List

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

The system shall be described in the following specification as manufactured by Schneider Electric

RSMSD Technical Guide

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

Contents. APC NetworkAIR AFX AFX

Modular Data Temp Systems Air Cooled Water/Glycol Cooled R-407C. 8, 10 and 13 ton capacities. ISO 9001 Certified

TEC Controller Multiple Compressor Heat Pump with Reversing Valve & Mixed Air Control, Application Application Note

Precision Air-Conditioning Units 60 Hz. Technical Data

Data Aire Series Chilled Water 7 through 50 ton

Contents. APC NetworkAIR AFX AFX

Data Aire Series Air Cooled, Water/Glycol Cooled 6 through 30 Ton Dual Circuits

Mini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

Computer Room Air-Conditioning 60 Hz. Technical Data

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

MARVEL MINI HVAC MICROPROCESSOR CONTROLLER

OTFAMU Fresh Air Make Up System For Chilled Water OPERATOR S MANUAL. Technicold Marine Systems

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

SEQUENCE OF OPERATIONS

ELECTRONIC HUMIDISTAT: H200

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

Your Home. Jacco & Assoc. Fan on with call for heating or cooling Heating on with call from space thermostat Stage as

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

Instruction Guide: Thermostat Operation

EL-TSTAT-8820 Safety & Installation Instructions

LuxPro Thermostats NEW MULTI-STAGE TOUCHSCREENS. Features & Programming. Mt. Laurel, NJ

Smart thermostat with Humidification/De-humidification control

HEAT COOL. Meets Commercial California Title 24

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

What is the Carrier Connect Wi-Fi Thermostat?

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

ATC32U01 igate Communicating, Programmable Thermostat

Chilled Water 7 to 211 kw

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

Programmable Thermostat

ALL PRODUCTS BROCHURE

Transcription:

Point Map Rev. 2, July, 2002 Systems Integration APOGEE Open Processor with Airflow Dataguard Driver: CCT DX Unit Table 1. CCT DX Unit, Analog Points. 01 LAI Return Air Temperature F 02 LAI Supply Air Temperature F 03 LAI PC/ECWS Water Temperature F 05 LAI Return Air Humidity % rh 09 LAI PC/ECWS Valve Position 0 100% 10 LAI Humidifier Position 0 100% 11 LAO Return Air Temperature High Alarm Set Point 0 100 F 12 LAO Supply Air Temperature High Alarm Set Point 0 100 F 13 LAO PC/ECWS Water Temperature High Alarm Set Point 0 100 F 14 LAO Hot Water Temperature High Alarm Set Point 0 200 F 15 LAO Return Air Humidity High Alarm Set Point 0 100% rh 19 LAI Hot Water Valve Position 0 100% 21 LAO Return Air Temperature Low Alarm Set Point 0 100 F 22 LAO Supply Air Temperature Low Alarm Set Point 0 100 F 23 LAO PC/ECWS Water Temperature Low Alarm Set Point 0 100 F 24 LAO Hot Water Temperature Low Alarm Set Point 0 200 F 25 LAO Return Air Humidity Low Alarm Set Point 0 100% rh 30 LAO Cooling Set Point 12 95 F 31 LAO Cooling Band 1 15 F 33 LAO Heating Set Point 0 85 F 34 LAO Heating Band 1 15 F 36 LAO Dehumidification Set Point 10 95% rh continued on next page... Siemens Building Technologies, Inc. Page 1 of 6

Table 1. CCT DX Unit, Analog Points. 37 LAO Dehumidification Band 1 30% rh 39 LAO Humidification Set Point 10 85% rh 40 LAO Humidification Band 1 30% rh 42 LAO Proportional Cool Offset -20 20 F 43 LAO Proportional Cool Band 1 15 F 45 LAO Supply Air Temperature Set Point F 46 LAO Supply Air Temperature Band F 52 LAO Assist Band (-4X16 and -4X24 Units Only) 53 LAO Assist Integral (-4X16 and -4X24 Units Only) 96 LAI Total Failed Commands 97 LAI Last Failed Command Point 98 LAI Last Failed Command Drop 99 LDI Communication Failure Normal/Alarm Table 2. CCT DX Unit, Integer Points. 01 LAI Model Number 02 LAI Version Number 03 LAI Version Integer Points Portion 04 LAO Standby Unit In Redundant Group (-4x18 and -4x31 Units Only) 06 LAI Number Of Heat Stages On 10 LAI Blower Run Hours, Low Bit Hrs 11 LAI Blower Run Hours, High Bit Hrs 16 LAI Humidifier Run Hours, Low Bit Hrs 17 LAI Humidifier Run Hours, High Bit Hrs 20 LAI Compressor 1 Run Hours, Low Bit Hrs 21 LAI Compressor 1 Run Hours, High Bit Hrs 24 LAI Compressor 2 Run Hours, Low Bit Hrs 25 LAI Compressor 2 Run Hours, High Bit Hrs 50 LAI Master Redundant Unit State (-4x18 and -4x31 Units Only) See Table 3 51 LAI Slave 1 Redundant Unit State (-4x18 and -4x31 Units Only) See Table 3 continued on next page... Page 2 of 6 Siemens Building Technologies, Inc.

Table 2. CCT DX Unit, Integer Points. 52 LAI Slave 2 Redundant Unit State (-4x18 and -4x31 Units Only) See Table 3 53 LAI Slave 3 Redundant Unit State (-4x18 and -4x31 Units Only) See Table 3 99 LAO Alarm Reset Address See Table 4 Table 3. Redundant Unit State (Integer Points, Points 50 to 53). Value Description 0 Not In Redundant Group 1 Unit Failed 2 Unit In Standby 3 Unit Running 4 Unit Assisting Table 4. Alarm Reset (Integer Points, Point 99). Value Description 1 Clogged Filter Alarm 2 Water Detection Alarm 3 Compressor 1 Low Pressure Alarm 5 Compressor 2 Low Pressure Alarm 6 Water Flow Alarm 7 Firestat Alarm 8 Smoke Monitor Alarm 9 Humidifier Alarm 10 Compressor 1 High Head Pressure Alarm 11 Compressor 2 High Head Pressure Alarm 12 Return Air Temperature Alarm 13 Supply Air Temperature Alarm 14 PC/ECWS Water Temperature Alarm 15 Hot Water Temperature Alarm 16 Humidity Alarm 20 Power Loss Alarm 21 Compressor 1 Pump Down Alarm 22 Compressor 2 Pump Down Alarm Siemens Building Technologies, Inc. Page 3 of 6

Table 5. CCT DX Unit, Digital Points. 01 LDO Celsius Units English/Celsius 02 LDO Unit Start Stop/Start 03 LDI Operating Mode - Cooling No/Yes 04 LDI Operating Mode - Heating No/Yes 05 LDI Operating Mode - Dehumidifying No/Yes 06 LDI Operating Mode - Humidifying No/Yes 07 LDI Master Enabled (-4x18 and -4x31 Units Only) Slave/Master 08 LDI Compressor 2 Pump Down Alarm Normal/Alarm 09 LDO Alarm Reset (See Table 4) No/Yes 10 LDI Airflow Alarm Normal/Alarm 11 LDI Clogged Filter Alarm Normal/Alarm 12 LDI Water Detector Alarm Normal/Alarm 13 LDI Compressor 1 Low Pressure Alarm Normal/Alarm 14 LDI System Enable Input Normal/Alarm 15 LDI Compressor 2 Low Pressure Alarm Normal/Alarm 16 LDI Water Flow Alarm Normal/Alarm 17 LDI Firestat Alarm Normal/Alarm 18 LDI Smoke Monitor Alarm Normal/Alarm 19 LDI Humidifier Alarm Normal/Alarm 20 LDI Compressor 1 High Head Pressure Alarm Normal/Alarm 21 LDI Compressor 2 High Head Pressure Alarm Normal/Alarm 22 LDI Return Air Temperature High Alarm Normal/Alarm 23 LDI Return Air Temperature Low Alarm Normal/Alarm 24 LDI Supply Air Temperature High Alarm Normal/Alarm 25 LDI Supply Air Temperature Low Alarm Normal/Alarm 26 LDI PC/ECWS Water Temperature High Alarm Normal/Alarm 27 LDI PC/ECWS Water Temperature Low Alarm Normal/Alarm 30 LDI Return Air Humidity High Alarm Normal/Alarm 31 LDI Return Air Humidity Low Alarm Normal/Alarm 38 LDI Power Loss Alarm Normal/Alarm 39 LDI Blower Off/On continued on next page... Page 4 of 6 Siemens Building Technologies, Inc.

Table 5. CCT DX Unit, Digital Points. 40 LDI Heater Stage 1 Off/On 41 LDI Heater Stage 2 Off/On 42 LDI Humidifier Off/On 43 LDI Compressor 1 Liquid Line Solenoid Closed/Open 44 LDI Compressor 1 Off/On 45 LDI Compressor 2 Liquid Line Solenoid Closed/Open 46 LDI Compressor 2 Off/On 47 LDI Compressor 1 Hot Gas Bypass (-4x06 and -4x18) or Compressor 1 Unloader (-4x09 and -4x31) 48 LDI Compressor 2 Hot Gas Bypass (-4x06 and -4x18) or Compressor 2 Unloader (-4x09 and -4x31) Closed/Open Closed/Open 49 LDI Common Alarm Normal/Alarm 50 LDO Airflow Alarm Enable Disable/Enable 51 LDO Clogged Filter Alarm Enable Disable/Enable 52 LDO Water Detector Alarm Enable Disable/Enable 53 LDO Compressor 1 Low Pressure Alarm Enable Disable/Enable 55 LDO Compressor 2 Low Pressure Alarm Enable Disable/Enable 56 LDO Water Flow Alarm Enable Disable/Enable 57 LDO Firestat Alarm Enable Disable/Enable 58 LDO Smoke Monitor Alarm Enable Disable/Enable 59 LDO Humidifier Alarm Enable Disable/Enable 60 LDO Compressor 1 High Head Pressure Alarm Enable Disable/Enable 61 LDO Compressor 2 High Head Pressure Alarm Enable Disable/Enable 62 LDO Return Air Temperature High Alarm Enable Disable/Enable 63 LDO Return Air Temperature Low Alarm Enable Disable/Enable 64 LDO Supply Air Temperature High Alarm Enable Disable/Enable 65 LDO Supply Air Temperature Low Alarm Enable Disable/Enable 66 LDO PC/ECWS Water Temperature High Alarm Enable Disable/Enable 67 LDO PC/ECWS Water Temperature Low Alarm Enable Disable/Enable 70 LDO Return Air Humidity High Alarm Enable Disable/Enable 71 LDO Return Air Humidity Low Alarm Enable Disable/Enable 78 LDO Blower Run Time Alarm Enable Disable/Enable continued on next page. Siemens Building Technologies, Inc. Page 5 of 6

Table 5. CCT DX Unit, Digital Points. 81 LDO Humidifier Run Time Alarm Enable Disable/Enable 83 LDO Compressor 1 Run Time Alarm Enable Disable/Enable 85 LDO Compressor 2 Run Time Alarm Enable Disable/Enable 89 LDI Return Temperature Sensor Failure Alarm Normal/Alarm 90 LDI Supply Temperature Sensor Failure Alarm Normal/Alarm 91 LDI Chilled Water Temperature Sensor Failure Alarm Normal/Alarm 92 LDI Hot Water Temperature Sensor Failure Alarm Normal/Alarm 93 LDI Return Humidity Sensor Failure Alarm Normal/Alarm 97 LDI Compressor Pump Down Alarm Normal/Alarm 98 LDI ECWS/Proportional Cooling Enabled ECWS/Proportional 99 LDI Electric/Proportional Heat Enabled Electric/Proportional Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes as design improvements are introduced. Other product or company names mentioned herein may be the trademarks of their respective owners. 2002 Siemens Building Technologies, Inc. Siemens Building Technologies, Inc. Printed in the U.S.A. 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 Page 6 of 6 U.S.A.