FirePro ANNEX 1 MARINE MANUAL. Version 1,

Similar documents
EC Type Examination Certificate

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

CERTIFICATE OF FIRE APPROVAL

Requirements for ships carrying hydrogen and compressed natural gas vehicles

Notice No. 7. Rules and Regulations for the Classification of Ships, July Issue date: March Working together for a safer world

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

Applicable international instruments for construction, performance and testing requirements 1

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

BUS ENGINE COMPARTMENT FIRE PROTECTION SYSTEM FIREPRO TEST REPORT PEER REVIEW

IMO. Resolution A.952(23) Adopted on 5 December 2003 (Agenda item 17) GRAPHICAL SYMBOLS FOR SHIPBOARD FIRE CONTROL PLANS

fixed dry aerosol fire extinguishing components FirePro Systems Ltd.

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

FirePro CERTIFICATES, APPROVALS & TEST REPORTS. Underwriters Laboratories of USA, UL Listing Certificate No EX6960, 02/08/11.

ClassNK Technical Information No. TEC-0453 Attachment (1) to ClassNK Technical Information No. TEC-0453 Guidance on SOLAS Chapter II-2 as amended in 2

OFFSHORE SUPPORT VESSELS 2014

Technical Information

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Only the Danish version is authentic Notice D II-2 N(2) 1 October 2002 CHAPTER II-2 N(2)

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

CO 2 Fire Extinguishing Systems

RESOLUTION MSC.292(87) (adopted on 21 May 2010) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

APPENDIX H (DESIGN SUBMISSION CRITERIA)

RESOLUTION MSC.145(77) (adopted on 5 June 2003) PERFORMANCE STANDARDS FOR WATER LEVEL DETECTORS ON BULK CARRIERS

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES

Consultant Specification AGILE Wireless Fire Detection System

A guide. Part 1: Code of practice for system design, installation, commissioning and maintenance. by T.L. Journeaux

User Information Sheet 008 : 2010

***** 2. Rev.1 is to be uniformly implemented by IACS Members from 1 July 2004.

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

MSC Guidelines for Automatic Sprinkler Systems

RESOLUTION MSC.188(79) (adopted on 3 December 2004) PERFORMANCE STANDARDS FOR WATER LEVEL DETECTORS ON BULK CARRIERS AND SINGLE HOLD CARGO SHIPS

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 1 GENERAL

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

Guideline No.: C-02(201510) C-02 FIRE DOORS. Issued date: October 20,2015. China Classification Society

RESOLUTION MSC.101(73) (adopted on 5 December 2000) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR APPLICATION OF FIRE TEST PROCEDURES

Fire Protection Scover

ISO INTERNATIONAL STANDARD. Ships and marine technology Fire-extinguishing systems for protection of galley cooking equipment

IMO FP 53 Report. Lloyd s Register report on the 53 rd session of IMO Fire Protection Sub-Committee. 16 th March, 2009

Report on First Revisions with Statement June 2014 NFPA 101

GASTEC QA. Approval Requirements 136

FirePro. Marine Fire Suppression System FP-8350 Control Panel 24vDC. Owners & Operators Manual. Fire Extinguishing Aerosol Systems.

NOTTINGHAM CITY HOMES

RESOLUTION MSC.98(73) (adopted on 5 December 2000) ADOPTION OF THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

DRY CHEMICAL POWDER SYSTEM REQUIREMENTS TO COMPLY WITH THE LATEST IMO IGC CODE AND EUROPEAN COUNCIL CLARIFICATIONS

Reflex fire detection and extinguishing system charged with Novec 1230 extinguishing agent. Installation, operation and maintenance instructions

RESOLUTION MSC.217(82) (adopted on 8 December 2006) AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

Australian Standard. Automatic fire detection and alarm systems System design, installation, and commissioning AS

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF

UK Direction BS7671 BS 8492 BS /01/2018

Bold items are particular to the City of Euless

Fire risk management plan. MH/05/Revised/06/17

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

IMO LIST OF DOCUMENTS ISSUED IN CONNECTION WITH THE FORTY-SEVENTH SESSION OF THE SUB-COMMITTEE ON FIRE PROTECTION AGENDA FOR THE FORTY-SEVENTH SESSION

DSPA DSPA B.V. Product Certificate K86591/07 UK. Non-Pressurized Condensed Aerosol Generators and Components K86591/06 UK

DETECT-A-FIRE Heat Detectors

VERSAFLOW VORTEX Supplementary instructions

SOUTH AFRICAN NATIONAL STANDARD

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

Ships and marine technology Fireextinguishing. of galley cooking equipment

Loss Prevention Standards

AUTOMATIC FIRE SUPPRESSION SYSTEMS

ISO INTERNATIONAL STANDARD. Ships and marine technology Lowlocation lighting on passenger ships Arrangement

INTERNATIONAL STANDARD

Idaho Surveying & Rating Bureau, Inc South Cobalt Point Way Tel: (208) Meridian, Idaho FAX: (208)

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Evacuation Tragedies Do Happen Kaprun Scandinavian Star Manchester Dusseldorf Airport Kings Cross

GENERAL SPECIFICATION ELECTRICAL

FIRE PREVENTION CODE

GASTEC QA. Approval Requirements 69-1

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Fire protection documentation. CFPA-E Guideline No 13:2015 F

NFPA 80 Overview January 21, 2016

CERTIFICATE OF FIRE APPROVAL

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

Identify RISKS. Design SOLUTIONS. Prevent DISASTERS

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

SPECIFICATIONS Power Requirements: V, 9.5A, 60Hz V, 5.8A, 50Hz Including 2A for internal convenience outlet.

SUP 14: Floor laying. Unified procedures for use within NHS Scotland

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

Sonos-SB Siren/Beacon

4) Intrinsic Safety Certification

Rules for Classification and Construction Additional Rules and Guidelines

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

GASTEC QA. Approval Requirements 15. for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas. KE 15 January 2012

Contents The IET Regulations, BS 7671, and this Guide 1.1 The need for this Electrician s Guide 1.2 The IET Regulations BS 7671

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

Transcription:

Marine Design Guide

ANNEX 1 MARINE MANUAL To be read and used in conjunction with FirePro Information, Instruction & User Manual Version 4, 01-05-2010 FirePro Systems Ltd 6 Koumandarias & Spyrou Araouzou Street Tonia Court No. 2, 6 th Floor, CY-3036 Limassol P O Box 54080, CY-3720 Limassol, CYPRUS Tel: +357 25 379 999, Fax: +357 25 354 432 Web: www.firepro.info, email: mail@firepro.info An ISO 9001:2008 & 14001:2004 registered company

ANNEX NO 1 MARINE APPLICATIONS DESIGN AND INSTALLATION GUIDELINES This Marine Application Annex contains the specific engineering guidance for the installation of the Fire Pro fire extinguishing aerosol systems, in accordance to the MSC1/Circ.1270. This Annex shall be read and used in conjunction with INFORMATION, INSTRUCTION&& USER MANUAL, Version 4, 01-05-2010. Marine Applications Codes of Reference: RS Rules for the Classification and Construction of Sea-Going Ships (2010), Rules for the Technical Supervision During Construction of Ships and Manufacture of materials and Products for Ships (2009), Chapter II-2 SOLAS-74, International Code for Fire Safety System (IMO Resolution MSC.98 (73)) and IMO MSC.1/Circ.1270: Revised Guide Lines for the Approval of Fixed Aerosol Fire- Extinguishing Systems equivalent to Fixed gas Fire- Extinguishing Systems, as referred to in SOLAS 74, for machinery spaces. SAFETY: MSC 1/Circ. 1270, chapter 14.1.5 A MINIMUM SAFE DISTANCE IS REQUIRED BETWEEN GENERATORS AND ESCAPE ROUTES AND COMBUSTIBLE MATERIALS. As per Information, Instruction and User Manual, version 4, 01-05-2010, the aerosol temperatures are indicated in the table at page 36 and in Figures A,B and C at pages 38, 39 and 40, whereby the safe distances for escape routes are related to the L3 values (in meters) in the table and minimum clearance from persons (light orange color)in Figures A,B and C. Safe distances for combustible materials are related to the L2 values (in meters) in the table and minimum clearance from combustible materials (dark orange color) in Figures A, B and C. MSC 1/Circ. 1270, chapter 14.7.3 MOUNTING LOCATIONS REQUIREMENTS CONSIDERING SAFE DISTANCE TO ESCAPE ROUTES AND COMBUSTIBLE MATERIALS. As per aerosol temperatures indicated in the table at page 36 and in Figures A,B and C at pages 38, 39 and 40, safe distances for escape routes are related to the L3 values (in meters) in the table and minimum clearance from persons (light orange color)in Figures A,B and C. Safe distances for combustible materials are related to the L2 values (in meters) in the table and minimum clearance from combustible materials (dark orange color) in Figures A, B and C. The generators should be located 1 meter from the ceiling, with the use of its supporting brackets. FirePro products are manufactured by FirePro Systems Ltd Page 1 of 12

Installation Guidelines Length = L D Iy D Iy D Iy D Iy D Ix D Ix D Ix D Ix Width = W D I : Installation Distance D Ix & D Iy : Installation Coordinates: N G : Number of Generators to be installed/spaced along the subject side D Ix = W/2*N G And, D Iy = L/2*N G For Ex.: if L = 6m & W = 4m then, D Ix = 4 / (2*2) = 4/4 = 1.0m, & D Iy = 6 / (2*2) = 1.5m FirePro products are manufactured by FirePro Systems Ltd Page 2 of 12

Installation Clearance - the Do s & Dont s Wrong Installation FirePro products are manufactured by FirePro Systems Ltd Page 3 of 12

Proper Installation FirePro products are manufactured by FirePro Systems Ltd Page 4 of 12

MSC 1/Circ. 1270, chapter 14.11.1 ELECTRICAL CIRCUITS FOR PYROTECHNIC GENERATORS: Requirements for mounting and protection of cables. It is covered in the FirePro Information, Instruction & User Manual, Version 4, 01-05-2010 under Section 11.1, page 53. 11.1 Cabling/Installation The cabling for the outgoing controls to the fire protection installation comes under the activities of the installer. Note: the execution must conform to NEN-2535 and NEN-1010:5 th edition. Fixed cabling for main current (230 V) must have a minimum conductor cross section of 1.5 mm. The cabling must be of flame retardant construction (NEN-1010), provided that no function retention is required. All the cables that are part of the fire detection and fire alarm system and evacuation installation must be red or be marked red every five metres. Cables in a terminal box must be provided with a loop, group and cable number. Only lay cabling in a conduit or a compartmentalised cable duct: In cable ducts a division plate or 50 mm spacing is required between the fire detection and fire alarm system cabling and the 230/380 V power current cabling; In cable ducts control current cabling may be laid with fire detection and fire alarm cabling if no disruptive mutual interference is to be expected; Conduit must connect to the cable duct; Open bends, maximum 50 x 50 mm, are only permitted above suspended ceilings and beneath raised floors; Protect conduits emerging from floors with impact-resistant conduit to 10 cm above the floor. Where cabling is laid directly alongside power current cabling, for example next to motor cables of an air conditioning system, then use screened or twisted cabling, lay in separate compartments or keep a minimum of 50 mm spacing between power current cabling and fire detection and fire alarm cabling. Where cabling is laid through fire-resistant partitions, suitable measures must be taken to ensure that the fire/smoke-resistance of the partition is not impaired. The wiring, technology and tools used must be used according to the requirements of approved workmanship, with the aim of minimising the chance of failure. Do not include any conductors in the fire detection and fire alarm system cabling that are fed from other installations. There may not be any joints in transmission paths, unless in consultation with the fire detection company and the local fire brigade. The joints must then be made in terminal boxes intended for the purpose. Any joints necessary must be housed in a completely sealed junction box. The conductors must be connected to the terminal strips with numbered screw terminals. 11.2 Function Retention Cabling The installation and the route of the cabling must be chosen so that the chance of damage of the cabling by fire is prevented and/or is as small as possible. This can be achieved by: Laying in the ground. Laying in a minimum of separate 30 minutes fire-resistant ducts. Use of fire-resistant cabling (cabling must conform to DIN 4102 Part 12 class E 30). FirePro products are manufactured by FirePro Systems Ltd Page 5 of 12

The following cables are concerned: Between the fire detection and fire alarm control unit and signal transmitters (slow whoop and flashlight). Between the fire detection and fire alarm control unit and the transmission equipment. Between the fire detection and fire alarm control unit and the fire brigade panel and any additional panels. Between the fire detection and fire alarm control unit and any control that automatically resets when the BMC is reset. The cable support of cables for which function retention is required must also remain functional for 30 minutes in the event of fire. 11.3 Cable Monitoring Cable monitoring according to NEN-2535 In addition, the following cabling must be provided with cable monitoring: Cabling to the transmission equipment if longer than 1.5 m. Cabling to the FirePro unit. Slow whoop. MSC 1/Circ. 1270, chapter 14.14 INSPECTIONS, MAINTENANCE, SERVICE AND TESTING REQUIREMENTS It is covered in the Information, Instruction and User Manual, version 4, 01-05-2010 l, under Section 12, at page 55. 12.0 Installation, Installation Tests, Delivery, Inspection and Maintenance 12.1 Installation The Schedule of Requirements with the execution drawings and any other relevant descriptions and/or certificates of the fire detection and fire alarm system must, before the installation is installed, have been approved by the local authority. Usually this will be the local chief fire officer of the municipality in which your business is located. The fire detection and fire alarm system can be supplied and also maintained by the authorised FirePro dealer or by a fire detection company that has been certified by a member of the NCP (National Centre for Prevention) or an equivalent of this body. The fire detection and fire alarm system must be installed by an expert and recognised installer. The installer must work in accordance with the requirements of certification under the responsibility of the authorised FirePro dealer or the fire detection company (supplier of the fire detection and fire alarm system). The authorised FirePro dealer, the installer and the specialised fire detection company may depart from the provisions of this schedule of requirements, if and in so far as approval has been granted by all the required parties and the author has drafted revisions for this schedule and has been correctly informed to this effect. Where the schedule of requirements differs from prevailing standards/directives, the schedule of requirements shall prevail. The installer must ensure that before the start of work the design and the siting of the installation has the approval of the local authorities, customer and owner. Following acceptance of order, on the basis of perusal of the respective (definitive) text and drawing of this schedule of requirements, the authorised FirePro dealer and/or the specialised fire detection company is responsible for the design and the installation of the fire detection and fire alarm system. FirePro products are manufactured by FirePro Systems Ltd Page 6 of 12

If and in so far as can subsequently be concluded that the actual situation differs or has become different from that on which the schedule of requirements is based, in particular where the intended use of the rooms is concerned, the owner/user of the installation and/or whoever installs the fire detection and fire alarm system must adapt the fire detection and fire alarm system to the newly arisen situation. For this purpose too advice can be obtained from FirePro Systems Ltd. In the event of any subsequent modification (including structural) of layout having an impact on the speed and reliability of fire detection and the fire alarm, the fire risk and/or on the chance of nuisance alarm/fault, consideration must again be given to whether an adjustment of the fire detection and fire alarm system is necessary and/or required (such as detector siting and detector choice). Any adjustment, for the above reasons, must be approved by all the parties concerned and/or required. This approval must be incorporated into the schedule of requirements. Important: If and in so far as the manufacturer s installation instructions differ from the schedule of requirements, for a careful implementation of the FirePro products contact must first be made with FirePro Systems Ltd. Primarily the installation instructions of the manufacturers and/or fire detection and firm alarm control unit and/or detection material must be followed. 12.2 Installation Tests and Delivery Following commissioning and installation an attestation (a written confirmation of approval) stating that the installation is working properly and conforms to all the technical descriptions must be issued by the installer/the fire detection company. At the time of delivery the fire detection company must supply the materials required for testing the detectors used. 12.3 Maintenance and Inspection During the period that the FirePro units are in use the following inspections and maintenance procedures must be carried out: A periodic inspection of the aerosol fire extinguishers and fire extinguishing systems to check the following parts: 1 electrical wiring 2 electrical circuit 3 thermocord 4 terminals of the electrical activator 5 electrical contacts 6 fixing bolts At the time of the final inspection the following documents must be issued: Schedule of Requirements Installation attestation conforming to NEN-2535 (or any other equivalent local standard) Brief and concise operating instructions, approved by the fire brigade Logbook of the fire detection and fire alarm system Revision drawings in triplicate with all the relevant details A signed maintenance contract The authorised FirePro dealer must provide a separate quotation for inspection, management and maintenance of the FirePro -based installation. The installer of the fire detection company must alert the customer to its obligation to carry out limited functional installation tests and maintenance, including a monthly functional test of the installation and transmission. This must be in accordance with NEN-2654 (or an equivalent local directive). The customer must ensure that this task is undertaken by a suitably trained officer under NEN- 2654 (or an equivalent local directive). The customer/user is obliged to conclude a maintenance contract in accordance with NEN-2654 (or an equivalent local directive) with the authorised FirePro dealer. This maintenance can for example stipulate that the installation be inspected and maintained annually. The maintenance contract must state: that the maintenance will be in accordance with NEN-2654 (or an equivalent local directive) that maintenance will be undertaken during the life of the installation FirePro products are manufactured by FirePro Systems Ltd Page 7 of 12

that the service provider will start on the rectification of a fault within 24 hours of receipt of a fault report and urgent interventions must also be included in the maintenance contract The suitably trained officer of the authorised FirePro dealer or the customer/user must keep a logbook, recording all the relevant events concerning the installation, such as false and nuisance alarms with any cause, switching off of detectors, detector groups, maintenance, inspections and installation tests, adjustments, expansions and repairs. Other areas of attention are: A periodic test (see life) for type E models; electrical activation must be carried out to check that the internal electrical circuit of the activator is intact. This test must be carried out with an ohmmeter with an accuracy of at least 2.5 ohm. The control current may not exceed 5 ma (milliampère). All the electrical wires and connections of the FirePro units to the control panel or the switch must also be tested and checked. A periodic inspection of the thermocord (see life) of the type TH models must be carried out to check that the thermocord and the connections to the aerosol fire extinguishers and/or fire extinguishing systems are intact. Any damaged parts must be replaced and reconnected. A periodic inspection of the metal casing (see life) of the solid extinguishing agent must be carried out to check whether the material is intact or has been damaged by chemically aggressive materials or corrosion. Whenever such inspection indicates that the metal casing has been damaged, the unit shall be replaced. All the metal brackets and connecting bolts must be inspected and tightened. Thanks to its chemical composition and properties the aerosol-forming extinguishing compound SBK (Solid Bound Compound) in the FirePro units does not require any further maintenance throughout its life. Life Time: the Certified Life Time of the FirePro units is 15 years. Logbook The logbook contains the items required that give a picture and provide for the recording of various things during the life of the installation. In the logbook you will find the following: Content of logbook: Introduction General details Devices used Management and maintenance requirements Measures on system activation Measures following system activation General rules and regulations for the user In the appendices: Periodic checks trained person Periodic check by maintenance expert Overview of automatic fire extinguishing system statistics Overview of periodic checks and preventive maintenance Overview of real fire statistics Overview of nuisance fire alarms Overview of false fire alarms Overview of system availability Safety information sheet Technical data FirePro units Certificate of delivery Installation drawings Schematic diagrams User instructions for BMC (fire detection and fire alarm control unit) Inspection reports FirePro products are manufactured by FirePro Systems Ltd Page 8 of 12

MSC 1/Circ. 1270, chapter 17 WHERE THE AEROSOL GENERATORS ARE INSTALLED WITHIN THE PROTECTED SPACE, THE GENERATORS SHOULD BE EVENLY DISTRIBUTED THROUGHOUT THE SPACE AND MEET THE FOLLOWING PROVISIONS: (See above Installation Guidelines drawings) - A manually initiated power release, located outside the protected space, should be provided. Duplicate sources of power should be provided for this release and should be located outside the protected space and be immediately available. - MSC 1/Circ. 1270, chapter 17.1 - Electric power circuits connecting the generators should be monitored for fault condition and loss of power. Visual and audible alarms should be provided to indicate this. - MSC 1/Circ. 1270, chapter 17.2 Electric power circuits connecting the generators should be duplicated and widely separated. Visual and audible alarms should be provided to indicate this. MSC 1/Circ. 1270, chapter 17.3 Within the protected space, electrical circuits essential for the release of the system should be fire resistant according to standard IEC 60331 or equivalent standards. MSC 1/Circ. 1270, chapter 17.4 The arrangement of generators and the electrical circuits essential for the release of any system should be such that in the event of damage to any one power release line or generator through mechanical damage, fire or explosion in a protected space, i.e. a single fault concept, at least the amount of agent needed to achieve the test density can still be discharged having regard to the requirement for uniform distribution of medium throughout the space. MSC 1/Circ. 1270, chapter 17.6 The installer shall comply with all the requirements of chapter 17. The actuation system supplied shall comply with all the requirements of chapter 17. MSC 1/Circ. 1270, chapter 22 The casing temperature of condensed aerosol generators should be measured in accordance with Appendix 1. This data should be used to establish the minimum safe distances away from the generator where the discharge temperatures do not exceed 75 o C and 200 o C. Temperature casings: the temperature values of the generators housing is indicated for each model in Table T1. FirePro products are manufactured by FirePro Systems Ltd Page 9 of 12

Table 1: Average Generator Housing Temperatures FIREPRO GENERATOR HOUSING TEMPERATURE MODEL Average Housing Temp. C L2 (m) L3 (m) FP20S 155 0.00 0.00 FP 40S 172 0.00 0.00 FP 80S 188 0.00 0.00 FP100S 220 0.01 0.10 FP 200S 276 0.03 0.30 FP 500S 290 0.05 0.50 FP1200 168 0.00 0.30 FP 2000 172 0.00 0.30 FP 3000 237 0.05 0.50 FP 5700 245 0.05 0.50 Measurements were taken approx. 3 minutes after discharge of the generator. L2= distance in metres away from the generator where the temp. does not exceed 200 o C. L3 = distance in metres away from the generator where the temp. does not exceed 75 o C. FirePro products are manufactured by FirePro Systems Ltd Page 10 of 12

MSC 1/Circ. 1270, chapter 3.4.2 DESIGN CALCULATION. AGENT Design application density Quantity of aerosol agent. The quantity of aerosol agent to be used should be determined as follows: where V x q (g) W = ------------- f W = agent mass (g) V = Volume of enclosure (m3) q = Design application density (gr/m3) f = Efficiency coefficient of generator s model (%) q = 113 gr/m3 (tests 1,2 and 3, flammable liquid fuels) q = 149 gr/m3 (wood crib fuel) Efficiency coefficients: FP-20S= 65% FP-500S = 91% FP-40S= 78% FP-1200 = 63% FP-80S= 74% FP-2000 = 64% FP-100S = 64% FP-3000 = 63% FP-200S = 63% FP-5700 = 61% MSC 1/Circ. 1270, chapter 11. The quantity of extinguishing agent for the protected space should be calculated at the minimum expected ambient temperature using the design density based on the net volume of the protected space, including the casing. MSC 1/Circ. 1270, chapter 11.1. The net volume of a protected space is that part of the gross volume of the space, which is accessible to the fireextinguishing agent. MSC 1/Circ. 1270, chapter 11.2. When calculating the net volume of a protected space, the net volume should include the volume of the bilge, the volume of the casing and the volume of free air contained in air receivers that in the event of a fire may be released into the protected space. FirePro products are manufactured by FirePro Systems Ltd Page 11 of 12

MSC 1/Circ. 1270, chapter 11.3. The objects that occupy volume in the protected space should be subtracted from the gross volume of the space. They include, but are not necessarily limited to:.1 auxiliary machinery.2 boilers.3 condensers.4 evaporators.5 main engines.6 reduction gears.7 tanks.8 trunks MSC 1/Circ. 1270, chapter 11.3. Subsequent modifications to the protected space that alter the net volume of the space should require the quantity of extinguishing agent to be adjusted to meet the requirements of this paragraph and paragraphs 10.1, 10.2, 10.3, 10.4, 12.2, 12.3, 12.4 and 12.5. FirePro products are manufactured by FirePro Systems Ltd Page 12 of 12