RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Similar documents
THINLINE TL2 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

CDL8 LED Architectural

IOTA Exit Signs. IOTA Emergency Fixtures

BACKUP BATTERY INSTALLATION INSTRUCTIONS

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

SECTION (16140) - WIRING DEVICES

Public Safety DAS Annunciator Panel

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

NEMA-4X Series. Certified for Harsh Environment Applications

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD

ARTEMIS Series of Low Occupancy LED Ceiling Mounted Fixtures (Including Stairwells) Installation & Operation Guide

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

Pictogram Exit Signs Catalogue

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Hanson LED C e i l i n g F a n

CEILING FAN OWNER'S MANUAL

SPECTRE BY. D778,422; D779,052; D779,093; D792,577; Add'l U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

CEILING FAN OWNER'S MANUAL

Installation Instructions

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

1 x4 Dimmable LED RetroFits

SP-1000X. Panic Device Power Controller Installation Guide. Rev

CEILING FAN OWNER'S MANUAL

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

CEILING FAN OWNER'S MANUAL

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

FerronTM. Instruction Manual A Kichler Decor ceiling fan

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

Installation and user manual for the BiWire / Conventional Repeater Panel

62" LED SPYRA. Product images may vary slightly from actual product. INSTRUCTION MANUAL

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

Oscillating Ceiling Fan

Model No: 56DFH-L HS-1289-C. Cover for non-light option

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

DISTRIBUTOR SELECT COLLECTION. EMERGI-LITE Full range of emergency lighting solutions

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

GROTON. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

Remote Chexit Module (RCM) System. General Information

Lights the way to safety SEVERE SERIES. Certified for Food Preparation and Cold Storage Applications. NEMA-4X Certified for Harsh Environments

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

Distributor Select LED Families

3SA60 3SA60+LED. Vogue & Vogue Plus. Net weight. This instruction contains 11 pages:

LaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

GAUGUIN BY. U.S. Patents: D513,319; D514,691; D514,692; D516,703; D517,201; D519,199 INSTRUCTION MANUAL WARRANTY CERTIFICATE

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

8TNR56XXXD-V1 Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 8TNR56XXXD-V1

LED Emergency Battery Backup

Aurora. MODERN FAN COMPANY Customer Service M-F 8am - 4pm (PST) (ph)

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

CEILING FAN OWNER'S MANUAL

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

TECHNICAL DATA OBSOLETE

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

CEILING FAN OWNER'S MANUAL

Ceiling Fan Installation Instructions

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

CEILING FAN OWNER'S MANUAL

54" Skye. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Staff Alert Panel. Installation Guide. Using the Touchpad Exit Controller B

Installation Instructions

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

CEILING FAN OWNER'S MANUAL

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

5CO52XX Series Fan UL Model No. : 5CO52. Owner s Guide and Installation Manual. Attach sales receipt to this card and retain as your proof of purchase

CEILING FAN OWNER'S MANUAL

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60006PC SAFETY PRECAUTION. Canopy. Downrod. Housing. Blade. Transmitter CR2032/3V

Turin LED Ceiling Fan

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Transcription:

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. Do not use outdoors. 2. Do not mount near gas or electric heaters. 3. Equipment should be mounted in locations and at heights where it will not readily be subject to tampering by unauthorized personnel. 4. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. 5. Do not use this equipment for other than intended use. 6. Supply connections must be made either inside the junction box for surface mount or the splice box in the recessed mount backbox. 7. Install using recommended junction box only. 8. Servicing of this equipment should be performed by qualified service personnel. SAVE THESE INSTRUCTIONS 3161 State Road Bensalem PA 19020 U S A Telephone: (215) 244-4204 Fax: (215) 244-4208 Page 1

Ceiling 4X No. 6 screws Attaches Power Supply Mounting Plate to Masonry Box Sign to Power Supply connection Canopy attaches to sign with 2x No. 8 screws INSTALLATION OF MASTER SIGN Before installing unit, disconnect power at breaker panel Canopy attaches to Mounting Plate with 2X No. 8 screws TOP OR END CANOPY MOUNT AC Power Connection Part No. M210076 4 gang masonry box 2-1/2 d x 3-3/4 h Typical: Crouse - Hinds TP685 (mounting by others) Power Supply mounted to Mounting Plate Low Voltage 4.8VDC connection to REMOTE SIGN (if required). Maximum run of 2 conductor wiring (by others): 50 ft. = AWG 22 100 ft. = AWG 18 300 ft. = AWG 12 Single or Double Face Sign Disassemble housing using 1/16 Allen wrench WALL MOUNT 4X No. 6 screws Attaches Back Plate to Masonry Box 2x Set Screws (tighten on Back Plate mounting pins while holding Faceplate flush to wall) Removable Lens Low Voltage 4.8VDC connection to REMOTE UNIT (if required) Wall Power Supply Mounted to Back Plate Power Input Back Plate 2x Set Screws (tighten on Faceplate mounting pins while holding Faceplate flush to wall) Connect power input wires to feed wires in junction box as per local code. Black lead for 120V or Orange lead for 277V CAP UNUSED LEAD White lead for neutral Green/Yellow lead for Ground. REAPPLY POWER AND NOTIFY THE AUTHORITY HAVING JURISDICTION Page 2

DIRECTIONAL INDICATORS Determine which directional indicator(s) are to be removed. Knock out as shown in the attached diagram. For the rear face on a double face sign, remove the tape and punch out the indicator(s). For front, die-cast face, knock out desired directional indicator(s) supporting Faceplate as shown All units, except Remotes, mount to a 4 gang masonry box supplied. Box must be mounted flush with wall surface. Remotes can be mounted to a standard 4 octagon J Box (supplied by others). INSTALLATION OF REMOTE SIGN Knockouts in Back Plate for attachment to wall by screws (supplied by others) Color Diffuser, Lens and Lens Reflector line up with square notch on the left hand side. Back Plate 2x Set Screws (tighten on Back Plate mounting pins while holding Faceplate flush to wall) Wall Low Voltage 4.8VDC connection to MASTER UNIT (supplied by contractor) Maximum run of 2 conductor wiring: 50 ft. = AWG 22 100 ft. = AWG 18 300 ft. = AWG 12 Low Voltage 4.8VDC Leads from REMOTE Faceplate 2x Set Screws (tighten on Faceplate mounting pins while holding Faceplate flush to wall) Lens Reflector Removable Lens Color Diffuser LED Array PC Board Page 3

SECURITY SHIELD INSTALLATION SINGLE FACE WALL MOUNT 4x Vandal Resistant Screws Fasten Security Shield to housing unused tapped holes with socket wrench, using 4 Vandal Resistant screws supplied. DOUBLE FACE CANOPY MOUNT 2x Canopy to Sign Mounting Screws 2x Canopy to Back Box Mounting Screws 8x Vandal Resistant Screws Page 4

RECESSED PENDANT SWIVEL ASSEMBLY Secure recessed Back Box into ceiling using means supplied by others. Run wires up Pendant Rod and secure Rod to Pendant Adapter on fixture using 2 mounting nuts supplied. Interconnect wires to power supply and install Swivel Ball, Swivel Bracket and Swivel Bracket. Recessed Back Box 3-3/4 x 7-1/2 2-1/2 deep Ceiling Opening: 3-3/4 x 7-1/2 (4x) Mounting Screws (Trim Plate to Back Box) (2x) Mounting Screws (Swivel Bracket to Trim Plate) Swivel Ball Trim Plate Cover 8-3/4 x 6 Swivel Cover (Snaps on to Swivel Bracket) (2x) Mounting Nuts (2x) Mounting Screws (Pendant Adapter to Razor Sign) Swivel Bracket Pendant Rod (Specify Length) Pendant Adapter Page 5

TWO CIRCUIT INPUT OPTION (AC VERSIONS ONLY) For AC versions with two circuit input, connect the input power from the main input to the leads marked MAIN, and from the backup input to the leads marked BACKUP. Note that the main and backup voltages can be either 120V or 277V. They do not have to be the same voltage. Connect to the Black lead for 120V or Orange lead for 277V, and White lead for Neutral. Cap off the unused leads. FLASHER / FIRE ALARM / BUZZER OPTIONS Battery Backup Emergency signs that are equipped with the FLASH IN EMERGENCY MODE OPTION or BUZZER IN EMERGENCY MODE option will automatically flash/beep in the emergency mode but not flash/beep on AC operation. AC Only exit signs that are equipped with the flash or buzzer options will flash/beep continuously while power is supplied. AC Only and Battery Backup Emergency signs that are equipped with the FIRE ALARM SIGNAL MODE FLASH or BUZZER options will automatically flash/beep in both AC and emergency modes upon application of a fire alarm signal to the YELLOW 18 AWG leads. The fire alarm signal can be either AC or DC of either polarity, and range from 12 to 24 volts. The current draw from the fire alarm signal is less than 10 milliamps. Units that include one of the above options, are intended for installation in locations where such features are permitted by local codes. Flasher Rate: 60 per minute Duty Cycle: 50 percent DIAGNOSTICS For units with Self-Testing / Self-Diagnostics option, refer to Operating Instructions. Battery back-up units without Self-Testing / Self-Diagnostics option include a battery diagnostics system which indicates, via flashing of the indicator light, that the battery needs replacement. If flashing occurs after a new installation, check that the battery plug is properly inserted into the circuit board connector. TEST FOR BATTERY BACKUP WITHOUT SELF-TEST / SELF-DIAGNOSTICS To test Battery backup units, use test switch to simulate AC power outage. The indicator light will go out, and the sign will remain lit, indicating transfer to emergency mode; and remain lit on battery power until switch is released. Release of switch will automatically restore AC/battery charge mode, with indicator light on. Testing for longer periods is best accomplished by turning off AC circuit power. Signs should be tested in accordance with National Electric Code and NFPA 101 Life Safety Code requirements which specify monthly testing for 30 seconds and yearly testing for 90 minutes. Note that the batteries will take some time to reach full charge after a prolonged test, and that the unit cannot provide full duration operation should a real power outage occur before the batteries have had an opportunity to reach full charge. It is recommended that long duration tests be limited to once yearly, and be conducted when the area will be unoccupied afterwards. Page 6

SELF-TESTING / SELF DIAGNOSTIC OPERATING INSTRUCTIONS This unit meets the requirements of NFPA 101 for Periodic Testing of Emergency Lighting Equipment. It provides visual indication of unit malfunctions including: Battery Fault Charger Fault Transfer Fault Lamp Fault STATUS INDICATIONS SHOWN ON FOLLOWING PAGE SELF-TEST The unit will perform a self-test and diagnostic function at least once every 28 days. The self-test will disable the charger and turn on the LEDs for 5 minutes to check the lamp load and battery. The test will be performed only if the battery is fully charged. If not, the test will automatically reschedule. The charger function is monitored continuously. USER-TEST A User-Test may be performed at any time the status display is continuous green. On initial power-up, it could take up to 72 hours for the status display to reach continuous green. With a fully charged battery, pressing the test switch momentarily will initiate a 30 second test. Pressing the test switch continuously for 4 seconds and releasing it will initiate a 90 minute test. Either test can be cancelled by pressing the test switch again for 1 second. REMOTE LAMP OPERATION The self-diagnostic system learns the lamp load when the unit reaches its first full charge. It is therefore necessary to have any remote lamps already connected when first applying AC power. Subsequent self-tests and user-tests will compare the actual lamp load to the learned value. If the remote lamp load is changed once it has been learned, it is necessary to disconnect AC power at the circuit breaker panel and unplug the internal battery. Once these are reconnected, the unit will learn the new lamp load. INFRA RED REMOTE TESTING To activate TRANSMITTER, remove tab from back of device. The USER-TEST can be performed up to 20 feet away using the optional INFRA RED REMOTE TESTING TRANSMITTER. By aiming the TRANSMITTER at the legend face, and pushing either the 30 SECOND or 90 MINUTE button for 1 second, all the TEST SWITCH functions can be performed. Page 7

STATUS INDICATIONS STATUS DISPLAY FUNCTION ACTION Continuous Green Battery in Float/Trickle Charge None Continuous Red Battery High Charging Wait for Green Status Flashing Green In Test Mode Wait for Test to Complete Alternate Red and Green Insufficient Charge for User Test Wait for Full Charge Red One Blink ON / Pause Transfer System Failure Factory Service Red Two Blinks ON / Pause Battery Failure Check Connections Replace Battery Red Three Blinks ON / Pause Charger Failure Factory Service Red Four Blinks ON / Pause Lamp Failure Check Remote Connection / Factory Service BATTERY REPLACEMENT To replace battery, disconnect branch circuit, detach unit from junction box, and cut plastic strap securing battery inside power supply chassis. Unplug battery connector from Printed Circuit assembly. Replace battery only with part number B310013. This product contains Ni-Cd batteries. Used Ni-Cd batteries may not be disposed of in the municipal solid waste stream. Ni-Cd batteries must be recycled or disposed of properly. For information on local recycling drop-off points, phone toll free 1-800-BATTERY. Page 8 Z410067