On the Influence of Shade in Improving Thermal Comfort in Courtyards

Similar documents
Dynamic sea level rise in a static spatial planning. 5th Nordic Conference on Climate Adaptation (NOCCA) Anders Rimne

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

Proceedings Enhanced Characteristics of Nondispersive Infrared CO2 Gas Sensor by Deposition of Hydrophobic Thin Film

Universidad de Navarra Pamplona. ABSTRACT

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 35 41

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

Design with nature: integrating green façades into sustainable buildings with reference to Abu Dhabi

The effects of green spaces (Palme trees) on the microclimate in arides zones, case study: Ghardaia, Algeria

Proceedings Cu Thin Film Polyimide Heater for Nerve-Net Tactile Sensor

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

Vertical Greenery Systems (VGS) as passive tool for energy savings and acoustic insulation in buildings

Smart Green Roofs: Cooling with variable insulation

Urban Shape and Energy Performance: Evaluation of The Typical Urban Structures of Prague

Vertical Greenery Systems (VGS) for energy savings in buildings

Procedia - Social and Behavioral Sciences 195 ( 2015 ) World Conference on Technology, Innovation and Entrepreneurship

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

EFFECTS OF COMBINING SMART SHADING AND VENTILATION ON THERMAL COMFORT

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

ISSN: [Agcaoili S. O., 7(3): March, 2018] Impact Factor: 5.164

HYGROTHERMAL PERFORMANCE BENEFITS OF THE CELLULOSE FIBRE THERMAL INSULATION STRUCTURES

Construction of An Automatic Power Switch using Infrared Motion Sensor

ENERGY EFFICIENCY BRIEF REPORT

1. COOL ROOFS. What is a Cool Roof

SMART GREEN ROOFS: Cooling with Variable Insulation

COOLING ENERGY SAVING SYSTEM USING A WATER MIST DEVICE ON WINDOWS

HYDRONIC COOLING OF THE THERMAL MASS ON HOUSE DWELLINGS ABSTRACT

The Effects of Green Spaces (Palme Trees) on the Microclimate in Arid Zones, Case Study: Ghardaia, Algeria

Residential Cluster, Ahmedabad: Housing based on the traditional Pols

Library of Birmingham integrated with The REP

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

CaseStudy Climate-ADAPT. Stuttgart: combating the heat island effect and poor air quality with green ventilation corridors

DAYLIGHTING PERFORMANCE ON VENETIAN BLIND FOR HEALTHY APARTMENT HOUSING

*Bioenergy GmbH Gewerbepark Haag 3, 3250 Wieselburg Land, Austria

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

POWER HOUSE Nearly Zero Energy Challenge Symposium. 26 September 2012 Madrid, Spain. Information Pack (09/08/2012 version)

Performance of Heat Recovery Ventilation System with Ground Source Brine Heat Exchanger Pre- Heating System in the Context of nzeb

Available online at ScienceDirect. Procedia Engineering 84 (2014 )

How Sensitive We Build to Climate? Design for Comfortable Urban Environment

Effects of Planting Date and Density on Tuber Production in Sandersonia aurantiaca

THE INFLUENCE OF CLIMATE IN THE FORMATION OF TRADITIONAL TURKISH HOUSES

Thermal Comfort with Convective and Radiant Cooling Systems

Brine Generation Study

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

The Effect of Quantity of Salt on the Drying Characteristics of Fresh Noodles

Investigating the Cooling Effect of Living Walls in the Sunken Courtyards of Traditional Houses in Yazd

Indoor Climate Control Effect of AAC Panel Heat Capacity Experimental rooms and simulations with three structural materials

GUIDANCE AND TOOLS FOR CHILLED CEILINGS COMBINED WITH A WET COOLING TOWER

The Application of Double-deck Inorganic Composite Fire Resisting Shutters in Constructional Engineering Bai-Xia ZHOU*

Automatic Detection of Defects on Radiant Heaters Based on Infrared Radiation

PCM-module to improve hot water heat stores with stratification: first tests in a complete solar system

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

Solar Passive Architecture Cooling Techniques

Effect of Relative Humidity on Oven Temperature of Locally Design Solar Carbinet Dryer

Teaching Landscape Spatial Design with Grading Studies: An Experiment Based on High Fidelity DTM

The urban block as a potential for sustainable urban design

PABLO FERNÁNDEZ VILLOCH

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Improving the performance of Air Cooled Chillers, Dry Coolers and Refrigeration Plants

Page 1. Brussels, 11 October europacable Rue Marie de Bourgogne 58 B-1000 Brussels EU Transparency Register ID

COOL BUILT FORMS The Design/Planning Dilemma of Courtyards

ACHEIVING COMFORT IN SUBTROPICAL CLIMATES: BUILDING A MICROCLIMATE IN THE GUANGZHOU SCIENCE MUSEUM

EVALUATION OF THE THERMAL PERFORMANCE OF METAL ROOFING UNDER TROPICAL CLIMATIC CONDITIONS

Fire propagation over combustible exterior facades exposed to intensified flame in Japan

Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

Architectural Review Board Report

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

A study of Transient Performance of A Cascade Heat Pump System

Depletion of Urban Green Space and Its Adverse Effect: A Case of Kumasi, the Former Garden City of West- Africa

Concluding Conference

Temperature Rises as Products Compete in the Heat. Market. Contact: Tim Page Press Release No: 20. Release date: Immediate Date: 11/11/09

Heat pump supplemental heating system for motor vehicles

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Optimisation of cooling coil performance during operation stage for improved humidity control

nzeb office building

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

To describe human body heat transfer, the concept. Thermal comfort with radiant and convective cooling systems. Articles. REHVA Journal June

Quantifying the performance of a passive deaerator in a gas fired closed loop domestic wet central heating system

INDOOR HUMAN THERMAL COMFORT OPTIMAL CONTROL WITH DESICCANT WHEEL COOLING SYSTEM

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

Lighting Depth: Courtyard Franklin Care Center, Franklin Lakes, NJ

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Slipping properties of ceramic tiles / Quantification of slip resistance

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Simulation study of evacuation in high-rise buildings

KEYWORDS: air temperatures, urban climate map, building Density, vegetation

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Demolition of a Designated Heritage Property Roncesvalles Avenue

Social impact assessment of a living wall installed in a hospital

COMPACT TECHNOLOGY AND INNOVATION ENCOMPASSED IN A COMPACT FORM

Evolution of the transport connection across the border: the role of the TGV and the future of the lorries. Girona, 2013

New emerging technologies for smart textile application

Development of Motor Fan Noise Prediction Method in Consideration of Operating Temperature during Engine Idling

Dr Mechtild Rossler (UNESCO World Heritage Centre): World Heritage and Cultural Heritage Management: New Conservation Challenges

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

RESULTS FROM HOUSE APPLIANCE SAFETY AND DEPRESSURIZATION TESTS CONDUCTED ON SINGLE FAMILY HOUSES UNDERGOING SOUND INSULATION

Victoria & Albert Museum, London Medieval & Renaissance Galleries: A Passive Approach to Humidity Control

The Use of Evaporative Cooling Panels in Tie Stall Dairy Barns

INSTRUMENTATION AND EVALUATION OF COMMERCIAL AND HOMEMADE PASSIVE SOLAR PANELS

Transcription:

Proceedings On the Influence of Shade in Improving Thermal Comfort in Courtyards Carmen Galán-Marín *, Victoria Patricia López-Cabeza, Carlos Rivera-Gómez and Juan Manuel Rojas-Fernández Departamento de Construcciones Arquitectónicas 1, Escuela Técnica Superior de Arquitectura, Universidad de Sevilla, Avda. Reina Mercedes, 2, 41012 Seville, Spain; vlopez7@us.es (V.P.L.-C.); crivera@us.es (C.R.-G.) jmrojas@us.es (J.M.R.-F.) * Correspondence: cgalan@us.es; Tel.: +34-954-556-591 Presented at the Economy, Sustainable Development and Energy International Conference (ESDEIC) 2018, Edinburgh, Scotland, UK, 25 27 June 2018. Published: 30 October 2018 Abstract: This study analyzes the thermal performance of courtyards in traditional buildings in the city center of Córdoba (South of Spain), one of them displaying a shading component, to determine the influence of this precise element. The courtyards have been monitored simultaneously during a summer period when temperatures during the day reached over 45 C. The obtained data was contrasted, and we confirmed that the shading element provided an improvement of the thermal performance of the courtyard which doubled the thermal leap between outdoor and inside the courtyard temperatures when the shading element was installed, in comparison to the courtyard without shade. Therefore, the tempering effect of courtyards can be significantly improved by means of using these simple elements. Keywords: inner courtyards; patio; Mediterranean climate; thermal comfort; shading 1. Introduction The design of nearly zero energy buildings (NEZB) is one of the main objectives of architecture regarding the predicted future of climatic change and energy shortage [1,2] There are many passive conditioning strategies to enforce in new buildings to achieve this objective energy saving. However, the real challenge is to be able to improve the energy performance of the actual building stock. Among the different passive strategies, the courtyard is an element that is already present in most buildings in certain climates. Being able to understand the thermal performance of the courtyards and the different elements that may affect them is the previous step to design an intervention strategy. Many factors have been reported to determine the thermal behavior of the courtyards i.e., geometry and orientation, vegetation, water, the albedo of the surfaces (the fraction of incident solar radiation reflected) and elements of shade [3,4]. This very last one could be the easiest and most economical one to be implemented in any existing building, what justifies the interest of this study. 2. Materials and Methods 2.1. Courtyards Description For our study, two courtyards with different geometries, were monitored during three weeks in the city of Córdoba (Spain, 37 53 00 N 4 46 00 O, elevation 106 m a.s.l). Córdoba is characterized by the highest summer severity possible in Spain as per the climate classification established in the Spanish Building Code. Proceedings 2018, 2, 1390; doi:10.3390/proceedings2221390 www.mdpi.com/journal/proceedings

Proceedings 2018, 2, 1390 2 of 5 The courtyards analyzed in this paper belong to two traditional patio- houses in the historic city center of Córdoba, World Heritage Site, which is characterized by its density of two to three storey buildings. To define the geometry of the courtyards, the concept of Aspect Ratio is used: AR = hmax/w (1) where hmax = maximum height of the courtyard and W = width of the courtyard. The two courtyards are described as follows: Courtyard A: It belongs to a traditional patio-house that has been refurbished. It is 4.3 4.0 m and a height of 6.3 m. The coating of the surface is white cement mortar. The courtyard has a maximum AR of 1.84 and a minimum of 1.47. The rooftop of the building is a terrace which allows the installation of a black canvas mesh that provides shadow to the courtyard, filtering the solar radiation that otherwise would affect the surfaces of its the walls (Figure 1a). The vegetation of the courtyard is another element that must be considered when analyzing its performance. Courtyard B: The building is a classic palace house that has suffered a few transformations through the time. Nowadays, the nearly squared courtyard is surrounded by an arcade in three of its four sides (Figure 1b). Its dimensions are 7.8 8.4 m and a height of 6.8 m. This means an AR of 0.81 and 0.87 in each direction. (a) (b) Figure 1. Images of the courtyards. (a) Canvas cover installed in the courtyard A. (b) Arcade of courtyard B. 2.2. Monitoring The monitoring took place during a three-week period of the hottest months of the year, from 26 July to 22 August of 2017. This period recorded the highest temperatures ever registered in Córdoba, that suffered an important heat wave that year, according to Spanish Meteorological Agency (AEMET). Air temperature was recorded inside the courtyard using sensors model TESTO 174 T located at three different heights at each wall of the courtyards. In order to avoid overheating due to solar

Proceedings 2018, 2, 1390 3 of 5 radiation, the sensors were protected with insulating material shields. A total number of twelve sensors were placed in each courtyard. Outdoor temperature and wind velocity were also recorded by means of a meteorological station model PCE-FWS 20 placed in the rooftop of the building. Courtyard A was monitored with the shading element from 26 July to 7 August, and without the shading component from 8 to 22 August. Courtyard B was monitored in the same unshaded conditions during that whole period. The canvas cover that was installed was black polyethylene of 60 70% UV filter, and around 70 g/m 2 density, fixed on top of the railing as shown in Figure 1.a, allowing the wind flows to go out of the courtyard, in order to avoid overheating and thus allowing the loose of accumulated heat during the day. 3. Results 3.1. Unshaded Monitoring Figure 2 shows the results obtained in six days during the period from 8 to 22 August, when none of the courtyards were shaded. The maximum outer air temperature ranged between 40 45 C during the day and minimum temperature at night registered 22 25 C. The figure also shows the recorded temperature in both courtyards during that period. Shading of Courtyard A was removed, creating the most possible similar situation to Courtyard B. Both courtyards displayed a very similar performance this period, with a maximum of 2 C of difference at peak hours (Courtyard B performing slightly better). The temperature in the courtyards does not go beyond 38 C. However, at night, there is a slight overheating effect, maintaining the courtyards around 2 C warmer than the outside. Figure 2. Air temperatures and wind speed in courtyards and the outside from 16 to 22 August. 3.2. Shaded Monitoring Figure 3 shows the results of the monitoring taking place from 1 to 7 August, a selected period when the shading element was installed in Courtyard A. In this period, outdoor temperatures ranged in the same values as the previously described, with a maximum of 45 C and a minimum of 22 C. In courtyard A, protected from direct solar radiation by the canvas cover, temperatures never went beyond 31 C. The night overheating effect still occurred. The indoor-outdoor temperature difference in this period reached 15 C in the shaded courtyard, the 5 August. Courtyard B presents similar monitoring results to those recorded in the previously analyzed period.

Proceedings 2018, 2, 1390 4 of 5 Figure 3. Air Temperatures and Wind Speed in courtyards and the outside from August 1st to 7th. 4. Discussion The comparison of the results provided by the two courtyards highlights the significant benefits of a simple shading element used to improve the performance of the courtyard in this climate. The mean temperature difference in both courtyards in the days from 26 July to 7 August has been calculated and represented as a type day in Figure 4. Unshaded means of both courtyards are rather similar, displaying a slight difference between 11:00 and 16:00 h of 1 2 C. However, contrasting Courtyard A lines, shaded and unshaded, it can be seen that the shading element produced a mean temperature difference of 12 C between the courtyard and the outside in the hottest hour of the day, while in the unshaded courtyard this difference was only 6 C on average. This allows us to emphasize the great improvement that a simple canvas element produces in the thermal performance of the courtyard. 5. Conclusions Figure 4. Mean Outdoor- Indoor temperature difference at each hour of the day. The results suggest that the already confirmed thermal benefits of courtyards in hot arid climates could be easily improved by using shading elements. The higher the exterior temperature was, the higher of a temperature drop was measured in the interior of the shaded courtyard. The relevance of this fact is the possibility of adopting this strategy in existing buildings, improving their energy efficiency and preparing them for the predicted global warming because of the climate change.

Proceedings 2018, 2, 1390 5 of 5 Author Contributions: C.G.-M. and J.M.R.-F. conceived and designed the experiments; C.R.-G. and J.M.R.-F. performed the experiments; V.P.L.-C. and C.G.-M. analyzed the data and wrote the paper. Acknowledgments: The authors wish to acknowledge the IUACC Instituto Universitario de Arquitectura y Ciencias de la Construcción for the necessary support to develop this research. This work has been funded by the National Government of Spain Research Project MTM2015-64577-C2-2-R. Conflicts of Interest: The authors declare no conflict of interest. The founding sponsors had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript, and in the decision to publish the results. References 1. Stocker, T.F.; Qin, D.; Plattner, G.K.; Tignor, M.M.B.; Allen, S.K.; Boschung, J.; Nauels, A.; Xia, Y.; Bex, V.; Midgley, P.M. Working Group I Contribution to the Fifth Assessment Report of the Intergovernmental Panel on Climate Change. In Climate Change 2013 The Physical Science Basis; Cambridge University Press: Cambridge, UK, 2013; pp. 33 115, doi:10.1017/cbo9781107415324.005. 2. European Commission. Directive 2010/31/EU of 19 May 2010 on the Energy Performance of Buildings (Recast). Off. J. Eur. Union 2010, 18, 13 35, doi:10.3000/17252555.l_2010.153.eng. 3. Ghaffarianhoseini, A.; Berardi, U.; Ghaffarianhoseini A. Thermal performance characteristics of unshaded courtyards in hot and humid climates. Build Environ. 2015, 87, 154-168, doi:10.1016/j.buildenv.2015.02.001. 4. Abdulkareem, H.A. Thermal Comfort through the Microclimates of the Courtyard. A Critical Review of the Middle-eastern Courtyard House as a Climatic Response. Procedia Soc Behav Sci. 2016, 216, 662 674, doi:10.1016/j.sbspro.2015.12.054. 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).