Low-voltage motors SIMOTICS GP, SD, DP Safety instructions for SH

Similar documents
Panel Fan Series Operators Manual (Galvanized and Polymer)

Panel Fan Series Operators Manual (Galvanized and Polymer)

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

STORAGE, ERECTION, OPERATION AND MAINTENANCE MANUAL FOR CENTRIFUGAL FANS MODEL - MXE

BELT DRIVEN STATIONARY AGITATOR

Installation, Operation & Maintenance Instructions Hazardous Area Electric Motors

Technical Manual. Operation and installation cooling units PKS 3000 SERIES 115V / 230V / 460V. Version 1.0, March 2018

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

57" Fiberglass Exhaust Fan with Cone

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Pump assembly Instruction manual

HKF 8180 Operating instructions

AXPR Wall Mounted Axial Panel Fans

Technical Manual. Operation and installation cooling units PKS 3000 SERIES 115V / 230V / 460V. Version 1.0, March 2018

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

CENTAFLEX Series A Assembly and operating instructions CF-AR M EN Rev. 2

GLEB Kitchen exhaust fan

p Permanent magnet water cooled motors Additional manual

OPERATION AND MONTAGE MANUAL ROOF FANS

51AKS I S O OWNER S MANUAL

OPERATION AND MONTAGE MANUAL ROOF FANS

IMPORTANT SAFETY INSTRUCTIONS

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D

Register at

Electric Salamander CHM-1200W CHM-2400W CHM-4350W. User s Manual

Operating instructions

The breaker trips at once when it is set to ON. The breaker trips in few minutes when it is set to ON.

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2A

Friwa Compact. Operating instructions EN

Centrifugal Fan Turbofan Type KT/KP

EL195DFE SERIES GAS FURNACE WARNING

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

MOULD WITH ENTERING PUNCHES

Instructions For Use ENG. LED Magnifier Lamp

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

EL195UH SERIES GAS FURNACE WARNING

Projector. Flush Mount

en EXTERNAL VIBRATORS AR 54. Operator s Manual

TRASCO ATEX Couplings

S150 S300 CONSTRUCTION HEATERS. Rev: August 15, 2008 SERVICE AND MAINTENANCE MANUAL No PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS

Pneumatic agitator A MAN R

Philips OneSpace luminous ceiling

Flameproof Manual Call Points

ANNEX GD-CERT-EX-EN SIT

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

ENGLISH INSTALLATION AND USER S MANUAL FRENCH NOTICE D INSTALLATION ET D UTILISATION ITALIAN MANUALE D ISTRUZIONE

USERS INFORMATION MANUAL

en Vibrating plate DPU 4045YE Operator's manual

Cabinet design and EMC SINAMICS. SINAMICS G130 Cabinet design and EMC. Safety information 1. General. Basic information about EMC 3

Liebert Small System MCD and PFH Condensers (1-5 Ton) Warranty Inspection Check Sheet

G61MPV SERIES GAS FURNACE WARNING

D O U B L E A U G E R M O R TA R M I X E R OWNER S MANUAL

GALAXY FLOOR MACHINE

MODULAR AUTOMATIC GRANULAR ICE FLAKER

AZN ATEX INSTALLATION AND MAINTENANCE

SFE 2311BK. EN Desktop Fan. Copyright 2017, Fast ČR, a.s

Dosing system. Commissioning and maintenance manual eco-pen300

TE 2 TE 2-M TE 2-S English

Installation Instructions Dual Fuel Ranges

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

EN Z Subject to change due to technical improvements! Operating instructions

Contents Safety Warnings... 3 Unpacking... 5 Installation... 6 Product Overview Operation Cleaning Maintenance...

OSSBERGER Trash Rack Cleaners program:

Air handling unit. X-CUBE compact. GB/en. Transport and installation manual. including X-CUBE compact accessories

INSTRUCTION MANUAL. operates with ISO9001 certified quality system. TECSYSTEM S.r.l Corsico (MI) Tel.: Fax:

Jet Fan Types AUC/ARC/AUR/ARR/AUO/ARO Installation and Maintenance

Installation, Operation, and Maintenance Manual

TH450A-CRB TH550A-CRB THP550-CRB/TS3000

Automatic Water System Pump SERIES

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

AeroVent 3X Product Manual

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

MARTIN Insertable Dust Collector

MicroGuard RCI 514 OPERATORS MANUAL PICK FROM BOOM MODE B

OPERATING INSTRUCTIONS HICUBE PRO. Turbo pumping station. Translation of the original instructions PT 0265 BEN/E (1602)

Installation of Glass Lined Equipment

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

OPERATION MANUAL. RUSTIBUS 400 ELECTRIC 3 Phase 220/380/440 V - 50 or 60/50/60 Hz. 3 x 380/440 V - 50/60 Hz.

High-Velocity Floor Fan

SINAMICS G130. Cabinet design and EMC. Operating instructions 03/2011 SINAMICS

English CNA-CNB. Centrifugal fans Installation and maintenance

WARNING This is a Warning statement that is related to the use of this heater. These statements warn of actions that may result in physical injury.

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

7 Hazard assessment 8 Worker participation 9 Hazard elimination and control

en Cutting machine RCE. Operator's manual

SINAMICS G130. Cabinet design and EMC. Operating Instructions 05/2010 SINAMICS

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

39 HQ Air Handling Units AiroVision

KKKKKKKCOOKER HOOD INSTRUCTION MANUAL

Transcription:

Low-voltage motors SIMOTICS GP, SD, DP Readme You can find the associated operating instructions in the Internet: Low-voltage motors (https://support.industry.siemens.com/cs/ww/en/ps/13309/man) Technical questions or additional information If you have any technical questions or require additional information, please contact Technical Support (https://support.industry.siemens.com/cs/ww/en/sc/2090). Please have the following data ready: Type Serial number You can find this data on the rating plate. Contact person If you wish to request on-site service or order spare parts, please contact your local office. This office will contact the responsible service center on your behalf. You can find your contact person in the relevant contact database: www.siemens.com/yourcontact (www.siemens.com/yourcontact) General safety instructions For your own personal safety and to prevent material damage when carrying out any work, always observe the safety-relevant instructions and the following five safety rules according to EN 50110-1 "Working in a voltage-free state". Apply the five safety rules in the sequence stated before starting work. Siemens AG 2018. All rights reserved A5E43215508A, 06/2018 1

General safety instructions 5 safety rules 1. Disconnect the system. Also disconnect the auxiliary circuits, for example, anti-condensation heating. 2. Secure against reconnection. 3. Verify absence of operating voltage. 4. Ground and short-circuit. 5. Provide protection against adjacent live parts. To energize the system, apply the measures in reverse order. Qualified personnel Ensure that only qualified personnel in the sense of these operating instructions work at the machine or close to the machine. Danger as a result of stationary parts under voltage (live parts) Live parts represent a hazard. Touch protection against active (live) parts is no longer guaranteed if covers are removed. The minimum air and creepage distances may be fallen below (violated) when coming close to active parts. Touching or coming close can result in death, serious injury or material damage. Carefully ensure that all of the covers are closed while operational. First switch off and disconnect the machine if you must remove covers. Carefully comply with the "Five safety rules " (Page 1). In operation, the terminal box must always be kept closed. It is only permissible to open the terminal box when the motor is stationary and in a no voltage condition. Risk of injury due to rotating parts Rotating parts are dangerous. Touch protection against rotating parts is no longer guaranteed if covers are removed. Touching rotating parts can result in death, serious injury or material damage. Carefully ensure that all of the covers are closed while operational. First switch off and disconnect the machine if you must remove covers. Comply with the "Five safety rules": Only remove the covers when the rotating parts have come to a complete standstill. 2 A5E43215508A, 06/2018

General safety instructions Risk of burn injuries as a result of hot surfaces Individual machine parts can become hot in operation. Burns can result when coming into contact with these parts. Never touch machine parts during operation. Allow the machine to cool down before starting work. Check the temperature of parts before touching them. If required, wear suitable protective equipment. Faults in operation Any changes with respect to the normal condition can indicate that the machine is not functioning correctly. Higher power consumption, temperatures or vibration levels. Unusual noise or smells. Monitoring devices respond. This can cause faults which can result in eventual or immediate death, serious injury or material damage. Immediately inform the service personnel. If you are in doubt, immediately switch off the machine, carefully observing the system-specific safety conditions. Damage caused by condensation Humidity in the air can condense for intermittent duty or load fluctuations. Condensate can collect. Moisture can have a negative impact on the winding insulation or result in damage, such as corrosion. Ensure that any condensation can freely flow away. Hazardous substances Chemical substances required for the setup, operation and maintenance of machines can present a health risk. Poisoning, skin damage, cauterization of the respiratory tract, and other health damage may result. Read the information in these operating instructions and the product information supplied by the manufacturer. Observe the relevant safety regulations and wear the personal protective equipment specified. A5E43215508A, 06/2018 3

Preparing for use, transport and storage Substances that can be easily ignited and are flammable Chemical substances required for the setup, operation and maintenance of machines may be flammable. Burns and other damage to health and material may result. Read the information in these operating instructions and the product information supplied by the manufacturer. Observe the relevant safety regulations and wear the personal protective equipment specified. Preparing for use, transport and storage Preconditions for safe lifting and transporting If you do not transport or lift the machine in a position appropriate for its construction, the machine can tip, slip into the lifting equipment or fall down. This can result in death, serious injury or material damage. Use only the load carrying device on the stator frame for lifting. Use the load carrying device appropriate for the machine position. Only use suitable rope guiding or spreading devices. Center of gravity not centered If the center of gravity of a load is not located centrally between the attachment points, the machine can tip over or slip out of the lifting equipment and fall when it is being transported or lifted. This can result in death, serious injury or material damage. Comply with the handling instructions on the machine when transporting it. Be aware of the possibility of different loads on the sling ropes or lifting straps and the carrying capacity of the lifting equipment. Always take account of the center of gravity when transporting or lifting the machine. If the center of gravity is not located centrally between the attachment points, then position the hoisting hook above the center of gravity. Risk of dropping and swinging when transported suspended If you transport the motor suspended from cables or ropes, the cables or ropes can break, e.g. as a result of damage. Further, if not adequately attached, the motor can swing. This can result in death, serious injury, or material damage. Use additional, suitable lifting equipment for transport and during installation. Two cables alone must be able to carry the complete load. Prevent the lifting equipment from sliding by appropriately securing it. 4 A5E43215508A, 06/2018

Mounting When using 2-cable lifting equipment, ensure that the maximum angle of inclination is 45 according to ISO 3266 (DIN 580). Align the eyebolts so that the cables used for lifting are aligned with the planes of the eyebolts. Toppling over or slipping of the motor The motor can slide or topple over if it is not correctly lifted or transported. This can result in death, serious injury, or material damage. Use all the lifting eyes on the machine. When using the lifting eyes on the machine, do not attach any additional loads or weight. The lifting eyes are only designed for the weight of the machine itself. Any eyes that are screwed in must be tightly fastened. Eyebolts must be screwed in right up to their supporting surface. Comply with the permissible eyebolt loads. When necessary, use suitably dimensioned lifting equipment, for example hoisting straps (EN1492-1) and load restraints (EN12195-2). Mounting Injury and material damage caused by inappropriate fastening material If screws of an incorrect property class have been selected or if they have been fastened to an incorrect tightening torque, they may break or become loose. This will cause the machine to move, which could damage the bearings. The rotor could smash into the machine enclosure and machine parts could be flung out of place. This can result in death, serious injury or material damage. Comply with the required property classes for screwed connections. Tighten the screwed connections to the specified tightening torques. Injury and material damage caused by incorrect machine alignment If the machine has not been properly aligned, this will mean the fastening parts are subjected to stress/distortion. Screws may become loose or break, the machine will move, machine parts could be flung out of place. This can result in death, serious injury or material damage. Carefully align the machine to the driven machine. A5E43215508A, 06/2018 5

Electrical connection Material damage caused by improper handling Mounting parts such as temperature sensors or speed sensors are attached to the machine and could be ripped off or destroyed as a result of improper handling. This could lead to machine malfunctions, extending even to total loss of the machine. Where necessary, use suitable steps when performing installation work on the machine. Do not stand on cables or attachments during installation. Do not use attachments as steps. Electrical connection Material damage as a result of connection parts coming loose If you use fixing elements made from the wrong material or apply the wrong tightening torque, this could impair current transfer or cause connecting parts to become loose. This could result in material damage to the machine or even in total failure, which could in turn lead indirectly to material damage to the system. Tighten the screwed connections to the specified tightening torques. Observe any specifications regarding the materials from which fixing elements must be made. When performing servicing, check the fastenings. Siemens AG Division Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY 6 A5E43215508A, 06/2018 A5E43215508A, 06/2018