TEST REPORT IEC 61215: nd Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval

Similar documents
Page 2 of 14 Report Ref. No

Type approval qualification of Photovoltaic Modules Procedures and test experiences

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

VDE-QT-PV001:2012/01

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

Test Report issued under the responsibility of:

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Amendment to Test Report

Fire Risks and Safety Standards

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements. TÜV Rheinland Shanghai Co., Ltd.

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

INTERNATIONAL STANDARD

Consumer Products Services Germany GmbH Türkheim Germany

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

EN50438 TEST REPORT SUMMARY. Requirements for the connection of micro-generators in parallel with public low-voltage distribution networks

Test report. ifesesws^ Date: Number: T /17 Project file: C Pages: Product: Fixed general purpose LED luminaire

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

Report reference No...: 10TH0052_AS4777_+_ISR_3 Tested by (printed name and signature)...: Urs Seifert. Approved by (printed name and signature)...

BS EN : A2:2015 used in conjunction with BS EN : A11:2014 and BS EN 62233:2008

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C,

This document is a preview generated by EVS

TEST REPORT IEC MEDICAL ELECTRICAL EQUIPMENT

PV Standards Activities SEIA Codes and Standards Workshop. Scott Jezwinski Business Development Manager Sep 12, 2016

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

Test Report No.: Page 2 of 14

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

Photobiological safety of lamps and lamp systems

Test Report issued under the responsibility of:

Survey of electrical equipment installed in hazardous areas on tankers

HMN-D2 Insert Series

Monocrystalline Solar Module LGXXXS1C(W)-L4. Installation Instructions MFL

Oldal/ Page 2 / 2 Test report No.: Submersible Pump Test item description... :

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Product Data Sheet 4114 N/17HH-218. The engineer's choice

Test Report Iec En Household And Similar

Test Report. Report No.: AGC SS01. Attestation of Global Compliance (Shenzhen) Co., Ltd.

CERTIFICATION BULLETIN

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

AS/NZS IEC :2013

ETSI TS V1.2.1 ( )

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Here Comes the Sun!!!

Lloyd s Register Type Approval System Test Specification Number 3

Update on the new IEC standards and their impact on quality of PV modules

AS/NZS :2016

This is a preview - click here to buy the full publication ICS ISBN

PAKISTAN STANDARD LED MODULES FOR GENERAL LIGHTING (SAFETY SPECIFICATIONS) PS: _5211/2017 ICS:

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

IECEE OPERATIONAL DOCUMENT

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Abu Dhabi Conformity Assessment Scheme for Small-scale Solar Photovoltaic Systems

Audible warning devices for external alarm

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

See cover page See cover page

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

INTERNATIONAL STANDARD

Solid State Lighting Sub-Assembly Interfaces for Luminaires. Andrew D. Jackson Philips Lighting Corporate Regulatory and Certification Laboratory

Original operating instructions Safety switch with guard locking AC901S AC902S

TEST REPORT IEC Safety of household and similar electrical appliances

TEST REPORT IEC Safety of household and similar electrical appliances

AS/NZS 62560:2017. Self-ballasted LED-lamps for general lighting services by voltage 50 V Safety specifications AS/NZS 62560:2017

AS/NZS IEC 62560:2014

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

NOTICE. (Formulated under the cognizance of the CTA R3 Audio Systems Committee.)

KALDEWEI SKIN TOUCH WELLNESSPRODUKT

TEST REPORT EN Safety of household and similar electrical appliances

UL YELLOW CARD FOR PLASTICS ADD MORE PROPERTIES, WIN NEW CUSTOMERS

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

TEST REPORT COL-001

This is a preview - click here to buy the full publication INTERNATIONAL STAN DARD. Radio-frequency connectors

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165

Modified Clauses of EN /A1:2004

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

TEST REPORT IEC/EN Safety of household and similar electrical appliances

UL Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General Requirements, Second Edition

Listing Constructional Data Report (CDR)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Test Report. Hotpoint Fridge Freezer Model FF175B

Model No.: VS806-6N ( ) V~ 50/60Hz LED 6x4W

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

TEST REPORT IEC Safety of household and similar electrical appliances

IECEx Certificate of Conformity

INTERNATIONAL STANDARD

Draft ES V1.1.1 ( )

CERTIFICATION BULLETIN

INTERNATIONAL STANDARD

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Provläsningsexemplar / Preview TECHNICAL REPORT. Part 3-1: Conformity verification report for IEC :2001 General requirements

INTERNATIONAL STANDARD

INSTRUCTION & SERVICE MANUAL

Transcription:

Test Report issued under the responsibility of: TEST REORT IEC 61215: 2005 2nd Edition Crystalline Silicon Terrestrial hotovoltaic (V) Modules - Design Qualification and Type Approval Test Report Reference No....: 208039-ET2-1 Date of issue (YYYY/MM/DD)...: 2015/04/22 Total number of pages...: 186 (104 pages of this report/ part of CB report) CB Testing Laboratory...: VDE rüf- und Zertifizierungsinstitut GmbH VDE Testing and Certification Institute Address...: Merianstrasse 28, D-63069 Offenbach Testing location/procedure...: CBTL RMT SMT CTF stage 1 stage 2 Address...: LG Electronics Inc. Umyeon R&D Campus, 16, Umyeon-dong, Seocho-Gu, Seoul, Korea Applicant s name...: LG Electronics Inc. Address...: 168, Suchul-daero, Gumi-si, Gyeongsangbuk-do, 730-903, Rep. of Korea Test specification... : Standard...: IEC 61215: 2005 2nd Edition Test procedure...: CB- Scheme CB-Full Certification Scheme Non-standard test method...: Test Report Form No....: IEC61215C Test Report Form Originator...: Underwriters Laboratories Inc. Master TRF...: Dated 2007-03, VDE modified 2014-09 Copyright 2007 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-iecee members, the IECEE/IEC logo shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. Test item description... : hotovoltaic (V) Module(s) Trade Mark...: Model/Type reference...: LGxxxN1W-G4, LGxxxN1C-G4 (xxx 280~340, 5steps) LGxxxN9W-G4, LGxxxN9C-G4 (xxx 270~290, 5steps) Manufacturer...: LG Electronics Inc. Ratings...: See page 4 VDE File No.: 924214-3972-0001/208039 CB/ DE1-55514

age 3 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Summary of testing: Tests performed (name of test and test clause): Full Test, IEC 61215 ed.2, IEC 61730-1 ed.1 and IEC 61730-2 ed.1 Testing location: See page 1 Testing procedure New module type Modifications (if yes, please choose the applicable modification according to the Retesting Guideline) to Basic Test Report: Change in cell technology Modification to encapsulation system Modification to superstrate Increase in module size Modification to backsheet/ substrate Modification to frame and/ or mounting structure Modification to junction box/ electrical termination Change in cell interconnect materials or technique Change in electrical circuit of an identical package Higher or lower power output (by 10%) in the identical package including size and using the identical cell process Qualification of a frameless module after the design has received certification as a framed module Change in bypass diode or number of diodes Testing Date of receipt of test item : 2015/01/27 Date (s) of performance of tests : 2015/01/27 ~ 2015/04/02 Module group assignment: Sample # Sample Group ID Sample S/N 1 A C1501062 2 B C1501063 3 C1 C1501006 4 C2 C1501065 5 D1 C1501067 6 D2 C1501068 7-1 E1 C1501025 7-2 E1 C1501026 8 E2 C1501027 9 MST C1501070 10 MST C1501071 11 MST C1501073

age 4 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Test item particulars: Accessories and detachable parts included in the evaluation... : -- Options included...: -- ossible test case verdicts: - test case does not apply to the test object...: - test object does meet the requirement...: ass () - test object does not meet the requirement...: Fail (F) Abbreviations used in the report: HF Humidity Freeze DH Damp Heat Imp Maximum power current Isc - Short circuit current mp Maximum power NOCT Nominal Operating Cell Temperature STC Standard Test Conditions TC Temperature Cycling Vmp Maximum power voltage Voc Open circuit voltage FF Fill Factor α Current temperature coefficient β Voltage temperature coefficient δ power temperature coefficient General remarks: "This report is not valid as a CB Test Report unless appended to a V-CB Conformity Assessment Certificate issued by a NCB, in accordance with IECEE 02 and IECEE 03". "(See Enclosure #)" refers to additional information appended to the report. "(See table)" refers to a table appended to the report. Throughout this report a point is used as the decimal separator. The tests results presented in this report relate only to the object tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. List of test equipment must be kept on file and available for review. Summary of compliance with National Differences: General product information and considerations: Tested Model was LGxxxN1W-G4, Size 1640 x 1000 x 40, 60 cell. The following model with less cells are included: LGxxxN9W-G4, Size 1480 x 1000 x 40, 54 cell. LGxxxN9C-G4, Size 1480 x 1000 x 40, 54 cell. LGxxxN1W-G4, LGxxxN9W-G4 (White Frame, White Backsheet) LGxxxN1C-G4, LGxxxN9C-G4 (Black Frame, White Backsheet) roduct Electrical Ratings: Module type LGxxxN1W-G4 LGxxxN1C-G4 LGxxxN9W-G4 LGxxxN9C-G4 Isc (Adc) 9,78 10,17 9,86 10,01 Voc (Vdc) 38,6 42,1 36,7 37,4 Imp (Adc) 9,13 9,75 9,35 9,54 Vmp (Vdc) 30,7 34,9 28,9 30,4 mp (W) 280 340 270 290 Maximum system voltage (V) Series Fuse Rating (A) 1000 1000 20 20

age 6 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Copy of marking plate:

age 7 of 186 Test Report Ref. No.: VDE 208039-ET2-1 hotos of the module (front and back): hotos of the junction box: hotos of the connector:

age 8 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10 TEST ROCEDURES (if it is not a full test, strikethrough non-performed test) Note: Deviations from test sequence are possible but must be documented. 8 Modules reconditioning 10.1 Visual Inspection 10.2 Maximum ower determination 10.3 Insulation test 10.15 Wet leakage current test A B C1 C2 D1 D2 E1 E2 10.4 Measurement of temperature coefficients α, β and δ 10.10 UV-test 10.11 Thermal cycling test 200 cycles -40 c to + 85 C 10.13 Damp heat test 1000h 85 C 85% RH 10.5 NOCT 10.11 Thermal cycling test 50 cycles -40 c to + 85 C 10.16 Mechanical load test 10.17 Hail test 10.6 erformance at NOCT 10.12 Humidity-freeze test 10 cycles -40 C to +85 C C 1 10.7 erformance at low irradiance 10.14 Robustness of terminations test 10.8 Outdoor exposure 60kWh/m² 10.18 Bypass-diode test 10.9 Hot-spot endurance test 10.15 Wet leakage current test

age 9 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61215 Ed.2 Design qualification and type approval Clause Requirement + Test Result - Remark Verdict 4 MARKING Name, monogram or symbol of manufacturer... : Type or model number... : LG310N1W-G4 Serial number... : Yes olarity of terminals or leads... : + and - mark on connectors Maximum system voltage... : 1000 V The date and place of manufacture... : Traceable by serial number Initial examination All modules 10 reconditioning...: 5 kwh/ m2 10.1 Visual inspection...: See table 10.1 Int 10.2 Maximum power determination...: See table 10.2 Int 10.3 Insulation test...: See table 10.3 Int 10.15 Wet leakage current test See table 10.15 Int Group A Control Module Sample Group ID A Group B 1 Module Sample Group ID B 10.4 Measurement of temperature coefficients See table 10.4 B 10.5 Measurement of Nominal Operating Cell Temperature (NOCT, C)... : See table 10.5 B 10.6 erformance at STC and NOCT...: See table 10.6 B 10.7 erformance at low irradiance...: See table 10.7 B 10.8 Outdoor exposure test See table 10.8 B 10.18 Bypass diode thermal test See table 10.18 B Maximum allowed junction temperature...: 200 Measured junction temperature...: 140,7 Diode still functions?...: Yes 10.9 Hot spot endurance test...: See table 10.9 B

age 10 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61215 Ed.2 Design qualification and type approval Clause Requirement + Test Result - Remark Verdict Group C 2 Modules Sample Group ID C1, C2 10.10 UV test...: 15 kwh/m² Final measurements See table 10.10 C 10.11 Thermal cycling test (50 cycles)...: Final measurements See appended table 10.11 C 10.12 Humidity freeze (10 cycles)... : Final measurements See table 10.12 C Group C1 1 Module Sample Group ID C1 10.14 Robustness of terminations test... : Final measurements See table 10.14 C1 Group D 2 Modules Sample Group ID D1, D2 10.11 Thermal cycling test (200 cycles)... : Final measurements See table 10.11 D Group E 3 Modules Sample Group ID E1, E2 10.13 Damp heat test... : Final measurements See table 10.13 E Group E1 2 Modules Sample Group ID E1 10.16 Mechanical load test...: 10.16.4 -No open-circuits or ground faults detected Final measurements See table 10.16 E1 Group E2 1 Module Sample Group ID E2 10.17 Hail test Number of points impacted... : 12 Final measurements See table 10.17 E2 Final measurement All modules 10.15 Wet leakage current test See table 10.15 F 10.2 Maximum power determination (final) See table 10.2 F

age 11 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.1 Int TABLE: Visual inspection (Initial) Test Date (YYYY/MM/DD)...: 2015/01/27 2015/02/09 Sample # Nature and position of initial findings comments or attach photos 1 No findings 2 No findings 3 No findings 4 No findings 5 No findings 6 No findings 7-1 No findings 7-2 No findings 8 No findings 9 No findings 10 No findings 11 No findings 10.2 Int TABLE: Maximum power determination (initial) Test Date (YYYY/MM/DD)...: 2015/01/27 2015/04/01 Module temperature ( C)...: 25 Irradiance (W/m 2 )...: 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) 1 10,01 40,6 9,47 33,2 314,5 77,4 2 9,95 40,6 9,41 33,3 312,8 77,4 3 9,93 40,6 9,38 33,2 311,8 77,3 4 9,98 40,7 9,44 33,3 313,9 77,3 5 10,00 40,7 9,46 33,3 314,5 77,3 6 9,91 40,7 9,43 33,3 314,2 77,9 7-1 9,97 40,6 9,45 33,1 312,9 77,3 7-2 9,94 40,6 9,43 33,2 313,3 77,6 8 9,95 40,7 9,43 33,2 312,6 77,2 9 9,94 40,5 9,40 33,2 311,8 77,5 10 9,88 40,6 9,34 33,3 310,7 77,5 11 10,00 40,7 9,44 33,3 314,0 77,1

age 12 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.3 Int Table: Insulation test (initial) Test Date (YYYY/MM/DD)...: 2015/01/27 2015/03/18 Test Voltage applied (V, DC)...: 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 1 > 999 25 -- 2 > 999 25 -- 3 > 999 25 -- 4 > 999 25 -- 5 > 999 25 -- 6 > 999 25 -- 7-1 > 999 25 -- 7-2 > 999 25 -- 8 > 999 25 -- 9 > 999 25 -- 11 > 999 25 -- Size of module 1,64 m². 10.15 Int TABLE: Wet leakage current test (Initial) Test Date (YYYY/MM/DD)...: 2015/01/27 2015/03/18 Test Voltage applied (V, dc)...: 1000 Solution resistivity (Ω cm)... : < 3500 Ω cm at 22 3 C Surface tension (Nm -2 )...: < 0.03 Nm -2 at 22 3 C Solution temperature ( C)...: 22 Sample # Measured (MΩ) Limit (MΩ) Result 1 > 999 25 2 > 999 25 3 > 999 25 4 > 999 25 5 > 999 25 6 > 999 25 7-1 > 999 25 7-2 > 999 25 8 > 999 25 9 > 999 25 11 > 999 25 Size of module 1,64 m².

age 13 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.4 B TABLE: Measurement of temperature coefficients Test Date (YYYY/MM/DD)...: 2015/02/10 Irradiance (W/m 2 ) high/low... : 1000 Module temperature ( C) high/low... : 15,0 75,0 Sample # arameter Calculated Value 2 α (%/ C)...: +0,0475 (+0,0047 A/ C) 2 β (%/ C)...: -0,2643 (-0,1075 V/ C) 2 δ (%/ C)...: -0,3623 (-1,1351 W/ C) 10.5 B TABLE: Measurement of Nominal Operating Cell Temperature (NOCT, C) Test Date (YYYY/MM/DD) : 2015/03/06 2015/03/07 2015/03/08 Sample # Average NOCT ( C) 2 44,7 Attach correction procedure and origin of module I-V correction parameters 10.6 B TABLE: erformance at STC and NOCT Test Date (YYYY/MM/DD)... : 2015/03/11 Test method... : indoor outdoor Ambient air temperature ( C) high/low...: 25,0 Irradiance (W/m 2 ) high/low...: 1000 / 800 Module temperature ( C) high/low...: 44,7 / 25,0 Condition Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) STC 9,91 40,6 9,36 33,2 311,0 77,3 NOCT 8,01 38,1 7,54 30.9 232,7 76,3 Attach correction procedure and origin of module I-V correction parameters

age 14 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.7 B TABLE: erformance at low irradiance Test Date (YYYY/MM/DD)... : 2015/03/11 Ambient air temperature ( C)... : 25 Irradiance (W/m 2 )... : 200 Module temperature ( C)... : 25 Test method... : Data corrected to a 25 C cell temperature and 200 W/m 2 irradiance Directly measured Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) 2 1,99 38,0 1,89 32,5 61,3 81,1 10.8 B TABLE: Outdoor exposure test Test Date (YYYY/MM/DD) start/end... : 2015/03/11 2015/03/23 Total irradiation dosage (kwh/m 2 )... : 62,07 (10.1 Visual inspection after outdoor exposure test) Test Date (YYYY/MM/DD)... : 2015/03/23 Sample # Nature and position of findings comments or attach photos 2 No findings (10.2 Maximum power determination after outdoor exposure test) Test Date (YYYY/MM/DD)... : 2015/03/23 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 2 9,88 40,6 9,34 33,2 310,6 77,4-0,70-5 (10.3 Insulation test after outdoor exposure test) Test Date (YYYY/MM/DD)... : 2015/03/23 Test Voltage applied (V, DC)... : 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 2 > 999 25 -- Size of module 1,64 m².

age 15 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.18 B TABLE: Bypass diode thermal test Test Date (YYYY/MM/DD) start/end... : 2015/03/31 Module temperature ( C)... : 73,0 77,7 Number of diodes in junction box... : 3 Diode manufacturer... : JMTHY Diode type designation... : THY2550 Max. permissible junction temperature Tj max [ C] (according to diode datasheet)... : 200 Diode 1 Diode 2 Diode 3 Result Current flow applied [A]... : 9,96 9,96 9,96 Max. diode surface temperature [ C] a or b : 122,8 133,6 126,7 Voltage drop [V]... : 0,360 0,358 0,359 ower dissipation [W]... : 3,586 3,566 3,576 Thermal resistance junction to leads (RTHJL)/to case (RTHJC) [K/W] (according to datasheet) : Calculated max. junction temperature Tj calc [ C] a or b... : 2 2 2 130,0 140,7 133,9 Tj calc < Tj max (test passed)? yes/no... : Yes Yes Yes Current flow (1.25 * Isc) [A]... : 12,45 12,45 12,45 Max. diode surface temperature [ C] a or b : 133,2 147,6 139,7 Remarks: ( a measured at diode case, b measured at diode leads) (10.1 Visual inspection after bypass diode thermal test) Test Date (YYYY/MM/DD)... : 2015/03/31 Sample # Nature and position of findings comments or attach photos 2 No findings (10.2 Maximum power determination after bypass diode thermal test) Test Date (YYYY/MM/DD)... : 2015/03/31 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 2 9,87 40,6 9,32 33,2 309,7 77,3-0,29-5 (10.3 Insulation test after bypass diode thermal test) Test Date (YYYY/MM/DD)... : 2015/03/31 Test Voltage applied (V, DC)... : 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 2 > 999 25 -- Size of module 1,64 m².

age 16 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.9 B TABLE: Hot-spot endurance test Test Date (YYYY/MM/DD) start/end... : 2015/04/01 2015/04/02 Cell interconnexion circuit...: S S SS Module temperature at thermal equilibrium [ C]...: 57,6 Determination of worst case cell Maximum measured cell temperature in 5 cycles [ C]: 151,8 Shading rate [%]...: 30 Worst Cell Number 60 (10.1 Visual inspection after hot-spot endurance test) Test Date (YYYY/MM/DD)... : 2015/04/02 Sample # Nature and position of findings comments or attach photos 2 No findings (10.2 Maximum power determination after hot-spot endurance test) Test Date (YYYY/MM/DD)... : 2015/04/02 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 2 9,80 40,6 9,26 33,2 307,5 77,3-0,71-5 (10.3 Insulation test after hot-spot endurance test) Test Date (YYYY/MM/DD)... : 2015/04/02 Test Voltage applied (V, DC)... : 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 2 >999 25 --

age 17 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.10 C TABLE: UV preconditioning test Test Date (YYYY/MM/DD) start/end... : 2015/02/10 2015/02/16 Module temperature [ C]... : 60 Irradiation total [kwh/ m²]... : 15,0 Sample # Open circuits (yes/no) 3 No 4 No (10.1 Visual inspection after UV preconditioning test) Test Date (YYYY/MM/DD)... : 2015/02/16 Sample # Nature and position of findings comments or attach photos 3 No findings 4 No findings (10.2 Maximum power determination after UV preconditioning test) Test Date (YYYY/MM/DD)... : 2015/02/23 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 3 9,84 40,5 9,28 33,2 307,7 77,2-1,31-5 4 9,84 40,6 9,30 33,2 308,9 77,3-1,59-5 (10.3 Insulation test after UV preconditioning test) Test Date (YYYY/MM/DD)...: 2015/02/16 Test Voltage applied (V, DC)...: 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 3 > 999 25 -- 4 > 999 25 -- Size of module 1,64 m².

age 18 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.11 C TABLE: Thermal cycling 50 test Test Date (YYYY/MM/DD) start/end... : 2015/02/23 2015/03/04 Total cycles (50)... : 50 Sample # Open circuits (yes/no) 3 No 4 No (10.1 Visual inspection after thermal cycling 50 test) Test Date (YYYY/MM/DD)... : 2015/03/04 Sample # Nature and position of findings comments or attach photos 3 No findings 4 No findings (10.2 Maximum power determination after thermal cycling 50 test) Test Date (YYYY/MM/DD)... : 2015/03/04 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 3 9,92 40,5 9,36 33,1 309,5 77,0 +0.58-5 4 9,92 40,6 9,36 33,1 310,2 77,0 +0,42-5 (10.3 Insulation test after thermal cycling 50 test) Test Date (YYYY/MM/DD)... : 2015/03/04 Test Voltage applied (V, DC)... : 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 3 > 999 25 -- 4 > 999 25 -- Size of module 1,64 m².

age 19 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.12 C TABLE: Humidity freeze 10 test Test Date (YYYY/MM/DD) start/end... : 2015/03/06 2015/03/16 Total cycles (10)... : 10 Sample # Open circuits (yes/no) 3 No 4 No (10.1 Visual inspection after humidity freeze 10 test) Test Date (YYYY/MM/DD)... : 2015/03/16 Sample # Nature and position of findings comments or attach photos 3 No findings 4 No findings (10.2 Maximum power determination after humidity freeze 10 test) Test Date (YYYY/MM/DD)... : 2015/03/16 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 3 9,81 40,6 9,24 33,1 305,9 76,8-1,16-5 4 9,87 40,6 9,29 33,1 307,2 76,7-0,97-5 (10.3 Insulation test after humidity freeze 10 test) Test Date (YYYY/MM/DD)... : 2015/03/16 Test Voltage applied (V, DC)... : 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 3 > 999 25 -- 4 661 25 -- Size of module 1,64 m².

age 20 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.14 C1 TABLE: Robustness of terminations test Test Date (YYYY/MM/DD) start/end.. : 2015/03/17 Types of terminations Type A: wire of flying lead Type B: tags, threaded stubs, screws, etc. Type C: connector Applied force in all directions [N]... : 40(Tensile) / 20(Bending) Sample # Open circuits (yes/no) 3 No (10.1 Visual inspection after robustness of terminations test) Test Date (YYYY/MM/DD)... : 2015/03/17 Sample # Nature and position of findings comments or attach photos 3 No findings (10.2 Maximum power determination after robustness of terminations test) Test Date (YYYY/MM/DD)... : 2015/03/17 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 3 9,79 40,6 9,23 33,1 305,3 76,9-0,20-5 (10.3 Insulation test after robustness of terminations test) Test Date (YYYY/MM/DD)... : 2015/03/17 Test Voltage applied (V, DC)... : 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 3 > 999 25 -- Size of module 1,64 m².

age 21 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.11 D TABLE: Thermal cycling 200 test Test Date (YYYY/MM/DD) start/end... : 2015/02/23 2015/03/30 Total cycles (200)... : 200 Applied current (A)... : 9,45 Limiting voltage (V)... : 55 Sample # Open circuits (yes/no) 5 No 6 No The enforced current is Imp at the STC condition. (10.1 Visual inspection after thermal cycling 200 test) Test Date (YYYY/MM/DD)... : 2015/03/30 Sample # Nature and position of findings comments or attach photos 5 No findings 6 No findings (10.2 Maximum power determination after thermal cycling 200 test) Test Date (YYYY/MM/DD)... : 2015/03/30 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 5 9,87 40,5 9,32 33,1 308,9 77,3-1,78-5 6 9,85 40,5 9,23 33,1 305,7 76,6-2,71-5 (10.3 Insulation test after thermal cycling 200 test) Test Date (YYYY/MM/DD)... : 2015/03/30 Test Voltage applied (V, DC)... : 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 5 > 999 25 -- 6 > 999 25 -- Size of module 1,64 m².

age 22 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.13 E TABLE: Damp heat 1000 test Test Date (YYYY/MM/DD) start/end... : 2015/01/28 2015/03/12 Total hours (1000)... : 1000 Sample # Open circuits (yes/no) 7-1 No 7-2 No 8 No (10.1 Visual inspection after damp heat 1000 test) Test Date (YYYY/MM/DD)... : 2015/03/12 Sample # Nature and position of findings comments or attach photos 7-1 No findings 7-2 No findings 8 No findings (10.3 Insulation test after damp heat 1000 test) Test Date (YYYY/MM/DD)...: 2015/03/12 Test Voltage applied (V, DC)...: 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 7-1 > 999 25 -- 7-2 > 999 25 -- 8 > 999 25 -- (10.15 Wet leakage current test after damp heat 1000 test) Test Date (YYYY/MM/DD)... : 2015/03/12 Test Voltage applied (V, dc)... : 1000 Solution resistivity (Ω cm)... : < 3500 Ω cm at 22 3 C Surface tension (Nm -2 )... : < 0.03 Nm -2 at 22 3 C Solution temperature ( C)... : 23 Sample # Measured (MΩ) Limit (MΩ) Result 7-1 > 999 25 7-2 > 999 25 8 > 999 25 Size of module 1,64 m².

age 23 of 186 Test Report Ref. No.: VDE 208039-ET2-1 (10.2 Maximum power determination after damp heat 1000 test) Test Date (YYYY/MM/DD)... : 2015/03/12 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 7-1 9,93 40,6 9,34 33,0 308,2 76,4-1,50-5 7-2 9,84 40,5 9,29 32,9 306,0 76,8-2,33-5 8 9,85 40,6 9,29 33,0 306,8 76,7-1,86-5

age 24 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.16 E1 TABLE: Mechanical load test Sample #... : 7-1 Test Date (YYYY/MM/DD)... : 2015/03/13, 2015/03/23 Mounting method... : See manual(bolt/nut method) Load applied to... : front side back side Mechanical load [a]... : 2400 / 5400 / 6000 2400 / 5400 First cycle time (start/end)... : 1h 1h Intermittent open-circuit (yes/no)... : No No Second cycle time (start/end)... : 1h 1h Intermittent open-circuit (yes/no)... : No No Third cycle time (start/end)... : 1h (5400 a) 1h Intermittent open-circuit (yes/no)... : No No Fourth cycle time (start/end)... : 1h (6000 a) 1h (5400 a) Intermittent open-circuit (yes/no)... : No No Fourth cycle is extra test for more critical condition (10.1 Visual inspection after mechanical load test) Test Date (YYYY/MM/DD)... : 2015/03/23 Sample # Nature and position of findings comments or attach photos 7-1 No findings (10.2 Maximum power determination after mechanical load test) Test Date (YYYY/MM/DD)... : 2015/03/23 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 7-1 9,83 40,5 9,21 32,9 302,7 76,0-1,78-5 (10.3 Insulation test after mechanical load test) Test Date (YYYY/MM/DD)... : 2015/03/23 Test Voltage applied (V, DC)... : 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 7-1 > 999 25 -- Size of module 1,64 m².

age 25 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.16 E1 TABLE: Mechanical load test Sample #... : 7-2 Test Date (YYYY/MM/DD)... : 2015/03/13, 2015/03/23 Mounting method... : See manual(clamp method) Load applied to... : front side back side Mechanical load [a]... : 2400 / 5400 / 6000 2400 / 5400 First cycle time (start/end)... : 1h 1h Intermittent open-circuit (yes/no)... : No No Second cycle time (start/end)... : 1h 1h Intermittent open-circuit (yes/no)... : No No Third cycle time (start/end)... : 1h (5400 a) 1h Intermittent open-circuit (yes/no)... : No No Fourth cycle time (start/end)... : 1h (6000 a) 1h (5400 a) Intermittent open-circuit (yes/no)... : No No Fourth cycle is extra test for more critical condition (10.1 Visual inspection after mechanical load test) Test Date (YYYY/MM/DD)... : 2015/03/23 Sample # Nature and position of findings comments or attach photos 7-2 No findings (10.2 Maximum power determination after mechanical load test) Test Date (YYYY/MM/DD)... : 2015/03/23 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 7-2 9,79 40,5 9,20 32,9 302,7 76,3-1,08-5 (10.3 Insulation test after mechanical load test) Test Date (YYYY/MM/DD)... : 2015/03/23 Test Voltage applied (V, DC)... : 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 7-2 > 999 25 -- Size of module 1,64 m².

age 26 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.17 E2 TABLE: Hail impact test Test Date (YYYY/MM/DD)... : 2015/04/01 Ice ball size [mm]... : 25 Ice ball weight [g]... : 7,53 Ice ball velocity [m/s]... : 23,0 Number of impact locations... : 12 Sample # Open circuits (yes/no) 8 No (impact location descriptions) (10.1 Visual inspection after hail impact test) Test Date (YYYY/MM/DD)... : 2015/04/01 Sample # Nature and position of findings comments or attach photos 8 No findings (10.2 Maximum power determination after hail impact test) Test Date (YYYY/MM/DD)... : 2015/04/01 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 8 9,76 40,6 9,20 33,0 303,7 76,6-1,01-5 (10.3 Insulation test after hail impact test) Test Date (YYYY/MM/DD)... : 2015/04/01 Test Voltage applied (V, DC)... : 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 8 > 999 25 -- Size of module 1,64 m².

age 27 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.2 F TABLE: Maximum power determination (final) Test Date (YYYY/MM/DD)... : 2015/03/16 2015/04/02 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Voc (V) Vmp (V) Isc (A) Imp (A) mp (W) FF (%) Degradation (%) Limit (%) 1 40,6 33,3 9,85 9,32 310,1 77,5-1,40-8 2 40,6 33,2 9,80 9,26 307,5 77,3-1,69-8 3 40,6 33,1 9,78 9,23 305,3 76,9-2,08-8 4 40,6 33,1 9,87 9,29 307,2 76,7-2,13-8 5 40,5 33,1 9,87 9,32 308,9 77,3-1,78-8 6 40,5 33,1 9,85 9,23 305,7 76,6-2,71-8 7-1 40,5 32,9 9,83 9,21 302,7 76,0-3,26-8 7-2 40,5 32,9 9,79 9,20 302,7 76,3-3,38-8 8 40,6 33,0 9,76 9,20 303,7 76,6-2,85-8 10.15 F TABLE: Wet leakage current test (final) Test Date (YYYY/MM/DD)...: 2015/03/02 2015/04/02 Test Voltage applied (V, dc)...: 1000 Solution resistivity (Ω cm)... : < 3500 Ω cm at 22 3 C Surface tension (Nm -2 )...: < 0.03 Nm -2 at 22 3 C Solution temperature ( C)...: 23 Sample # Measured (MΩ) Limit (MΩ) Result 1 > 999 25 2 > 999 25 3 > 999 25 4 661 25 5 > 999 25 6 > 999 25 7-1 > 999 25 7-2 > 999 25 8 > 999 25 Size of module 1,64 m².

age 28 of 186 Test Report Ref. No.: VDE 208039-ET2-1 erformance at STC:

age 29 of 186 Test Report Ref. No.: VDE 208039-ET2-1 erformance at NOCT:

age 30 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Test Report issued under the responsibility of: TEST REORT IEC 61730-1 V Module Safety Qualification art 1: Requirements for construction Test Report Reference No.... : 208039-ET2-1 Date of issue (YYYY/MM/DD)... : 2015/04/22 Total number of pages... : CB Testing Laboratory... : Address... : Applicant s name... : Address... : 186 (104 pages of this report/ part of CB report) VDE rüf- und Zertifizierungsinstitut GmbH VDE Testing and Certification Institute Merianstrasse 28, D-63069 Offenbach, Germany LG Electronics Inc. 168, Suchul-daero, Gumi-si, Gyeongsangbuk-do, 730-903, Rep. of Korea Test specification: Standard... : IEC 61730-1 Ed. 1 + A1:2011 + A2:2013 Test procedure... : Non-standard test method..: Test Report Form No.... : TRF Originator... : CB- Scheme IEC61730_1A TÜV Rheinland roduct Safety GmbH Master TRF... : Dated 2007-11, VDE modified 2014-09 Copyright 2007 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-iecee members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. Test item description... : hotovoltaic (V) Module(s) Trade Mark... : Model/Type reference... : Manufacturer... : LGxxxN1W-G4, LGxxxN1C-G4 (xxx 280~340, 5steps) LGxxxN9W-G4, LGxxxN9C-G4 (xxx 270~290, 5steps) LG Electronics Inc. Ratings... : See page 4

age 31 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Testing procedure and testing location: CB/CCA Testing Laboratory: Testing location/ address... : Associated CB Laboratory: Testing location/ address... : Tested by (name + signature)... : Approved by (name + signature). : Testing procedure: CTF stage 1 Tested by (name + signature)... : Approved by (name + signature)... : Testing location/ address... VDE rüf- und Zertifizierungsinstitut GmbH VDE Testing and Certification Institute Section ET2 Merianstrasse 28, D-63069 Offenbach, Germany (Authorization of test report) (Authorization of test report) Testing procedure: CTF stage 2 Tested by (name + signature)... : Kwang-sik Hyoung Witnessed by (name + signature).. : Approved by (name + signature)... : Roland Herbert (Authorization of test report) Jürgen Bärwinkel Testing location/ address...umyeon R&D Campus, 16, Umyeon-dong, Seocho-Gu, Seoul, Korea Testing procedure: SMT Tested by (name + signature)...: Approved by (name + signature)..: Supervised by (name + signature): Testing location/ address... : Testing procedure: RMT Tested by (name + signature)...: Approved by (name + signature)..: Supervised by (name + signature): Testing location/ address... :

age 32 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Summary of testing: Tests performed (name of test and test clause): Full test, IEC 61730-1 Testing location: See page 1 Summary of compliance with National Differences: See appended Report EUROEAN GROU DIFFERENCES AND NATIONAL DIFFERENCES to IEC 61730-1. Copy of marking plate:

age 33 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Test item particulars... : Accessories and detachable parts included in the evaluation... : -- Other options included... : --... :... : ossible test case verdicts: - test case does not apply to the test object... : - test object does meet the requirement... : (ass) - test object does not meet the requirement... : F (Fail) Abbreviations used in the report: CTI Comparative Tracking Index FF Fill factor Ipm Maximum power current Isc Short circuit current MST Module Safety Test D artial Discharge STC Standard Test Conditions RTI Relative Thermal Index Voc Open circuit voltage Vpm Maximum power voltage max Maximum power Testing Date of receipt of test item... : 2015/01/27 Date (s) of performance of tests... : 2015/01/27 ~ 2015/04/02 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma (point) is used as the decimal separator. This Test Report Form is intended for the investigation of V module in accordance with IEC 61730-1. It can only be used together with IEC 61730-2 Test Report. List of test equipment must be kept on file and available for review. Factory (for information only) Name... : Address... : LG Electronics Inc. 168, Suchul-daero, Gumi-si, Gyeongsangbuk-do, 730-903, Rep. of Korea

age 34 of 186 Test Report Ref. No.: VDE 208039-ET2-1 General product information: V module type reference... : LGxxxN1W-G4 roduct Electrical Ratings at STC Nominal maximum power (max)...: 310 W Nominal short circuit current at (Isc)...: 9,96 A Nominal open circuit voltage at (Voc)...: 40,4 V Nominal maximum power current (Ipm)...: 9,45 A Nominal maximum power voltage (Vpm)...: 32,8 V roduct Safety Ratings Maximum system voltage...: 1000 V Maximum over-current protection rating...: 20 A Safety application class...: A Safety class in accordance with IEC 61140...: II Fire safety class...: C Recommended maximum series/parallel module configurations...: 19/1 Scope of Module Safety Qualification Testing Initial Module Safety Qualification Extension of Module Safety Qualification Original Test Report Ref. No : Change in cell technology Modification to encapsulation system Modification to superstrate Increase in module size Modification to frame and/or mounting structure Modification to junction box/el. termination Change in cell interconnect materials/technique Change in el. circuit of an identical package Modification to backsheet/substrate Higher or lower output by 10% Note (1) Use the General product information field to give any information on model differences within a product type family covered by the test report. Note (2) Use the General product information field to describe the range of electrical and safety ratings, if the TRF covers a type family of modules. Note (3) Use Annex 1 to list the used materials and components of the module (manufacturer, type reference)

age 35 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict 3 ALICATION CLASSES The module has been evaluated for the following Application Class (Class A, B, C)... : Class A 4 CONSTRUCTION REQUIREMENTS 4.1 General requirements 4.1.1 It is stated that the module is able to operate under environmental condition type AB8 according to IEC 60364-5-51. 4.1.2 The module/s is/are completely assembled when shipped from the factory. The module is provided in subassemblies. 4.1.3 Incorporation of a module into the final assembly does not require any alteration of the module from its originally evaluated form. If YES, specific details describing necessary modification(s) are provided in the installation instructions. 4.1.4 If the module must bear a definite relationship to another module, it is constructed to permit incorporation into the final assembly without the need for alteration. 4.1.5 The construction of the module is such that ground continuity is not interrupted by installation. 4.1.6 arts of the module are prevented from loosening or turning, if such loosening or turning may result in a risk of fire, electric shock, or injury to persons. 4.1.7 Friction between surfaces is not used as the sole means to inhibit the turning or loosening of a part. 4.1.8 Any adjustable or movable structural part is provided with a locking device to reduce the likelihood of unintentional movement. 4.2 Metal parts Metals used in locations that are exposed to moisture shall not be employed alone or in combinations that could result in deterioration, such that the product would not comply with the requirements in this standard. Iron or mild steel serving as a necessary part of the module but not exposed to the weather are plated, painted, or enameled for protection against corrosion. Simple sheared or cut edges and punched holes are not required to be additionally protected. No 5 OLYMERIC MATERIALS

age 36 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict 5.1 General olymeric materials serving as an enclosure for live metal parts... : olymeric materials serving as support for live metal parts... : olymeric materials serving as the outer surface for the module... : See Sub clause 5.2 See Sub clause 5.3 See Sub clause 5.4 olymeric materials serving as barriers... : See Sub clause 5.5 All polymeric materials have a minimum thermal index (electrical and mechanical, as defined by IEC 60216-5) of 20 C above the maximum measured operating temperature of said material in application, as measured during the Temperature Test MST 21 given in IEC 61730-2. All concerned polymer passed the IEC 61730-2, MST 21 test The RTI of junction box is approved by UL. (E82268, 644(f1)(c)) Considering of minimum thickness (2,0 mm), RTI is 125 (Electrical), 125, 125 (Strength). 5.2 olymers serving as an enclosure for live parts Information is provided that polymers serving as an enclosure for live parts comply with: Junction box separately approved by TUV Rheinland based on EN 50548:2011+A1 (R 50298578) The polymers is approved by UL. (E82268, 644(f1)(c)) -. f1: Suitable for outdoor use with respect to exposure to Ultraviolet Light, Water Exposure and Immersion in accordance with UL 746C a) 5-V flammability rating (IEC 60695-1-1) From the drawing design, the minimum size is 2,25 mm. b) 5-V flammability rating, after water immersion and exposure of the end-product (IEC 60695-1-1) V-0, 5VA is applied for 2,0 mm The enclosure for live parts is not immersed in the water. But this material is suitable for water immersion based on UL approval c) Ultraviolet radiation resistance (ANSI/UL 746C) No direct UV. This part is shaded. But this material is suitable for outdoor UV radiation based on UL approval d) Minimum hot wire ignition rating of 30 (IEC 60695-1-1) For 2,0 mm, LC assigned is 2. HWI range mean ignition time is 30 s through 59 s

age 37 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict 5.3 olymers serving to support live parts Information is provided that polymers serving to support live parts comply with: a) Flammability classification and high-current arc ignition rating (IEC 60695-1-1) as given in Table 1 of IEC 61730-1 Junction box separately approved by TUV Rheinland based on EN 50548:2011+A1 (R 50298578) The minimum thickness is over 2,25 mm. The flammability classification is V-0, 5VA. Material s assigned LC is 0. So, HAI range mean number of arcs is 120. b) Comparative Tracking Index (CTI) 250 V Comparative Tracking Index (IEC 60112) : c) Inclined plane tracking rating of 1 h, using the time to track method at 2.5 kv (ASTM D2303), if the maximum system operating voltage rating is in the range 600 1500 V. The IT is 120 min at 1.5 kv Maximum system operating voltage rating (V): 1000 V d) Ultraviolet radiation resistance (ANSI/UL 746C) No direct UV. This part is shaded. 5.4 olymers serving as an outer surface Information is provided that polymeric substrates or superstrates used in the module have: 5.4.1 a) A thermal index, both electrical and mechanical, as determined in accordance with IEC 60216 of at least 90 C. b) A thermal index of at least 20 C above the maximum measured operating temperature of the material as measured during the Temperature Test MST21 of IEC 61730-2. 5.4.2 olymeric materials that serve as the outer enclosure for a module that (1) is intended to be installed in a multi-module or -panel system or (2) have an exposed surface area greater than 1 m² or a single dimension larger than 2 m, has a maximum flame spread index of 100 as determined under ASTM E162-1990. 5.4.3 If exposed to direct sunlight in the application, the polymeric material has been evaluated for ultraviolet (UV) radiation resistance as determined in accordance with ANSI/UL 746C. 5.4.4 olymeric materials intended for use as a superstrate or substrate, without appropriate IEC insulation pre-qualification, comply with the requirements of the artial Discharge Test MST 15 of IEC 61730-2. Middle layer of Toray backsheet, type LTW-09ST-2 is Toray, Lumirror -10S with RTI 125 (UL file E86511) Approved by JET (1543-C9801-049) D test by TUV Rheinland for system voltage 1135 Vdc 5.5 olymers serving as barriers

age 38 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict Insulation barriers are of adequate thickness and of a material appropriate for the application, as defined by IEC 61140 Barriers or liners are held in place and are not adversely affected See Annex 2 for technical details 5.6 olymers serving as structural glazing materials olymers serving as structural glazing materials comply with the requirements for safety glazing by material certification (ANSI Z97.1-93) or by testing in accordance with Module Breakage Test MST 32 of IEC 61730-2. Tested according to MST 32 6 INTERNAL WIRING AND CURRENT-CARRYING ARTS Any current-carrying part and wiring has the mechanical strength and current-carrying capacity necessary for its application. 6.1 Internal wiring 6.1.1 Wiring used within a module has an insulation rating for a minimum of 90 C, with a gauge and voltage rating acceptable for the application as defined by the requirements of IEC 60189-2. 6.1.2 The wiring of a module is located so that after installation of the module in the intended manner the insulation is not exposed to degrading effects of direct sunlight. Cable is separately approved by TUV Rheinland (R 50205246) based on 2 fg 1169/08.07 and by UL based on UL Subject 4703(E343893) The insulation rating temperature is 90 6.2 Splices Splices are insulated equivalent to that required for the wiring involved. No splices is present 6.3 Mechanical Securement 6.3.1 Joints or connections are mechanically secure and provide electrical contact without strain on connections and terminals. 6.3.2 Uninsulated live parts are secured to its supporting surface so that they are prevented from turning or shifting in position. 7 CONNECTIONS 7.1 Field connections general requirements

age 39 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict 7.1.1 The module is provided with wiring terminals, connectors, or leads to accommodate currentcarrying conductors of the load circuit. 7.1.2 Field connections are rated for exposure to direct sunlight as defined in Clause 5 of IEC 61730-1. Field connections are exposed to the degrading effects of direct sunlight. Lead is connected to the connector directly. Connector is separately approved by TUV Rheinland (R 50175587) based on EN 50521:2008 and by UL based on UL Subject 6703 (E341975) Lead is connected to the connector directly. Connector is separately approved by TUV Rheinland (R 50175587) based on EN 50521:2008 and by UL based on UL Subject 6703 (E341975) Lead is connected to the connector directly. Connector is separately approved by TUV Rheinland (R 50175587) based on EN 50521:2008 and by UL based on UL Subject 6703 (E341975) 7.2 Field wiring terminals 7.2.1 Field wiring terminal blocks are rated for the appropriate voltage and current for the application and constructed in compliance with IEC 60947-1. 7.2.2 Wiring terminals integral to the construction of the terminal enclosure comply with the following requirements: 7.2.2.1 a) Screws and nuts which clamp external conductors have a thread conforming with ISO 261 or ISO 262 (or comparable standards) The screws and nuts used for field wiring do not serve to fix any other component. 7.2.2.2 b) Terminal screws have a minimum nominal thread diameter as shown in Table 2 of IEC 61730-1. Stud terminals are provided with nuts and washers. 7.2.2.3 c) Terminals are designed that they clamp the conductor between metal surfaces with sufficient contact pressure and without damage to the conductor. Terminals are designed or located that the conductor cannot slip out when the clamping screws or nuts are tightened. Terminals are fixed suitably when the means of clamping the conductor is tightened or loosened: The terminal itself does not work loose, Internal wiring is not subjected to stress,

age 40 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict Creepage distances and clearances are not reduced below the values specified in clause 9 of IEC 61730-1. 7.3 Connectors 7.3.1 The connector intended for use in the output circuit of the module is rated for the appropriate voltage and current, as per the requirements of the IEC 60130 series. Connectors comply with the requirements of Clause 5 of IEC 61730-1, with respect to flammability, comparative tracking index and relative thermal index for the support of live parts. 7.3.2 The connector has been appropriately evaluated for disconnect overload performance. 7.3.3 Connectors intended for exposure to the outdoor environment are enclosed by material which complies with the following: a) UV resistance in accordance with the requirements of Clause 5. b) Resistance to inclusion of water acc. to IEC 60529 (equivalent to I55) Lead is connected to the connector directly. Connector is separately approved by TUV Rheinland (R 50175587) based on EN 50521:2008 and by UL based on UL Subject 6703 (E341975) No I 67 c) Steel ball impact test acc. to IEC 61721 d) Accessibility Test MST 11 of IEC 61730-2 Verified with test MST 11 of 61730-2 7.3.4 Separable multi-pole connectors are polarized. 1 connector is male type. 1 is female type. Improper connection is not possible If two or more separable connectors are provided, they are configured or arranged so that the other will not accept the mating connector for one. 7.3.5 For a connector incorporating a grounding member, the grounding member is the first to make and the last to break contact with the mating connector. 7.3.6 Connectors that can be separated without the use of a tool do not have accessible conductive parts, as determined under the Accessibility Test MST 11 of IEC 61730-2. No grounding member in the connector No accessible conductive part Verified with test MST 11 of 61730-2 7.4 Output lead or cables

age 41 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict Leads extending from the module are rated for the appropriate system voltage, ampacity, wet locations, temperature and sunlight resistance.. System voltage: 600 V (UL), 1000 V (TUV). Ampacity: 12 AWQ, 4,0. Wet location: WET or DRY. Temperature: -40-90. Sunlight resistance : SUN RES 8 BONDING AND GROUNDING 8.1 If accessible conductive parts of the module form a perimeter framing or mounting system, or if the module has a conductive surface area of greater that 10 cm² accessible after installation, then the module has provisions for grounding. 8.2 If the module is rated as safety class II and provided with provisions for functional grounding, the functional grounding is isolated from live parts by reinforced insulation (Sub clause 7.3.2.2 of IEC 61140). 8.3 Each exposed conductive part of the module, that is assessable during normal operation, is bonded together, as verified by Ground Continuity Test MST 13 of IEC 61730-2. Note: If conductive materials are used only as fasteners for installation and separated from the conductive components of the module by both appropriate insulation and spacings, they are not required to be bonded. 8.4 Routine maintenance of the module does not involve breaking or disturbing the bonding path. A bolt, screw, or other part used for bonding purposes is not intended for securing the complete device. 8.5 Bonding is by a positive means, such as clamping, riveting, bolted or screwed connections, or welding, soldering or brazing. The bonding connection penetrates all nonconductive coatings, such as paint, anodized coatings or vitreous enamel. 8.6 All joints in the bonding path are mechanically secure. 8.7 If the bonding connection depends upon screw threads, two or more screws or two full threads of a single screw engage the metal. Grounding position and the way to grounding are stated in the installation instruction. Verified by 10.3 of IEC 61215 Verified by MST 13 of IEC 61730-2 Bonding position is not broken or disturbed during the routine maintenance. There are installation holes except for ground hole. Bolted connection or Clamping connection (Verified by MST 13 of 6173002) The washer s pin is screwed in side of coatings. Mechanically secure, without soldering.

age 42 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict 8.8 The diameter of the grounding screw or bolt is sized appropriately to the gauge of the bonding conductor, as per Table 2 of IEC 61730-1. 8.9 Ferrous metal parts in the grounding path are protected against corrosion by metallic or nonmetallic coatings. 8.10 The module has metal-to-metal multiple-bearing pin-type hinges. These are considered to be an acceptable means for bonding. 8.11 A wiring terminal or bonding location is identified with the appropriate symbol (IEC 60417-5019) or has a green-colored part. No other terminal or location is identified in this manner. 8.12 If a marking is used to identify an equipment grounding terminal, it is located on or adjacent to the terminal, or on a wiring diagram affixed to the module or panel near the terminal. See the construction details No ferrous metal parts contained Multiple-bearing pin-type hinge not present Identified Grounding mark is attached near the grounding point. 9 Creepage and Clearance distances 9.1 Creepage and clearance distances between uninsulated live parts not of the same potential and between a live part and an accessible metal part, are not less than the values specified in Tables 3 and 4 of IEC 61730-1. Class A, Max. system voltage: 1000 V Minimum measured creepage and clearance distances between field wiring terminals (mm)... : Minimum Measured clearance distances between internal current carrying parts and accessible points (mm)... : 9.2 Creepage and clearance distances at field wiring terminals have been judged on module open-circuit voltage (V oc ). If additional unmarked terminals exist in the terminal block, or if wiring terminals are marked specifically for grounding, the creepage and clearance distances have been judged on the basis of the maximum system operating voltage. 9.3 The spacings at a field-wiring terminal have been measured with and without wire connected to the terminal. If the terminal will properly accommodate it, and if the product was not marked to restrict its use, the wire is one size larger than that required, otherwise, the wire is of the required size.. Cell to edge : >8,4 mm. Ribbon to edge : >8,4 mm. The frameless module was used. No such terminals

age 43 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict 9.4 Surfaces separated by a gap of 0,4 mm or less have been considered to be in contact with each other. Considered 10 FIELD WIRING COMARTMENTS WITH COVERS 10.1 General If the module is designed for the application of a permanently attached wiring system by an installer in the field, it is to be provided with an enclosed wiring compartment 10.2 Wall thickness If the wiring compartment is intended for the attachment of a field-applied permanent wiring system, the minimum wall thickness for the material complies with Table 5 of IEC 61730-1. 10.3 Internal volume The internal volume for each intended conductor complies with the requirements of Table 6 of IEC 61730-1. In the space comprising the minimum required volume, no enclosure dimension is less than 20 mm. 10.4 Openings All openings are provided with appropriate coverings, whose functions comply with the requirements of: Sub clause 5.2.1 of IEC 61730-1 Wet leakage Current test of Sub clause 10.20 of IEC 61646 or 10.17 of IEC 61215 Ed. 2. Accessibility test MST 11 of IEC 61730-2 Coverings can only be removed by the use of a tool 10.5 Gaskets and seals Gaskets and seals do not deteriorate beyond limits during accelerated ageing, and are not used where they may be subject to flexing during normal operation. 10.6 Strain relief

age 44 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict Any strain relief is provided so that stress on a lead intended for field connection, or otherwise likely to be handled in the field, including a flexible cord, is not transmitted to the electrical connection inside the module. Note: Mechanical securement means which comply with Sub clause 10.14 (Robustness of Terminations Test) of IEC 61215 meet this requirement. 10.7 Sharp edges 10.7.1 The enclosure is smooth and free from sharp edges, burrs, or the like that may damage insulation or conductors. 10.7.2 The inner edges of conduit openings and knockouts are smooth and free from sharp edges, burrs, or the like that may damage insulation or conductors. 10.8 Conduit applications Metallic 10.8.1 Any threaded hole in a metal wiring compartment intended for the connection of rigid metal conduit is reinforced to provide metal not less than 6,4 mm thick. Any threaded hole is tapered unless a conduit end stop is provided. 10.8.2 If threads for the connection of conduit are tapped all the way through a hole in a compartment wall, there are not less than 3.5 nor more than 5 threads in the metal and the construction was such that a conduit bushing can be attached as intended. The construction is such that a conduit bushing can be attached as intended. 10.8.3 If threads for the connection of conduit are not tapped all the way through a hole in a compartment wall, there are not less than 5 full threads in the metal and there was a smooth, rounded inlet hole for the conductors. There are smooth, rounded inlet holes for the conductors. 10.8.4 For a non-threaded opening in a metal wiring compartment intended to accommodate rigid metallic conduit, a flat surface of sufficient area is provided around the opening to accept the bearing surfaces of the bushing and lock washer. 10.8.5 Conduit complies with the Conduit bending test MST 33 of IEC 61730-2. 10.9 Conduit applications Non-metallic 10.9.1 The thickness of sides, end walls, and bottom of a non-metallic wiring enclosure specified for conduit applications is not less than the values specified in Table 7 of IEC 61730-1.

age 45 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict 10.9.2 A non-metallic wiring compartment intended to accommodate non-metallic conduit fulfils the following requirements: a) It has one or more unthreaded conduitconnection sockets; b) It has one or more threaded or unthreaded openings for a conduit-connection socket, or one or more knockouts that comply with the requirements of Knockout Test MST 44 of IEC 61730-2; c) It complies with the Conduit Bending Test MST 33 of IEC 61730-2, if intended for rigid non-metallic conduit. 10.9.3 Sockets for the connection of non-metallic conduit provide a positive end stop for the conduit. The socket diameters, the throat diameter at the entrance to the box, the socket depths, and the wall thickness of the socket are within the limits specified in the applicable conduit system. 10.9.4 A knockout or opening in a non-metallic wiring compartment intended to accommodate rigid nonmetallic conduit complies with the dimensional requirements of the applicable conduit system. 11 MARKING 11.1 The module includes the following clear and indelible markings: Name, monogram or symbol of manufacturer Type or model number LG310N1W-G4 Serial number Yes olarity of terminals or leads + and - mark on connectors Maximum system voltage 1000 V Safety class (IEC 61140) Symbol The date and place of manufacture are marked on the module or are traceable from the serial number. International symbols are used where applicable. 11.2 The following additional markings are applied to either the module or placed into the instruction and installation data (required documents). Traceable by non-recurring serial number/ date on label Voltage at open-circuit On label Current at short-circuit On label

age 46 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict Maximum over-current protection rating, as verified by the Reverse Current Overload Test MST 26 of IEC 61730-2 Recommended maximum series/parallel module configurations On label / in manual In manual Application class On label / in manual All electrical data are given relative to Standard Test Conditions (1000W/m 2 @ 25 C) 11.3 Connectors suitable only for field assembly of modules are marked Do not disconnect under load. 11.4 For modules with open-circuit voltage in excess of 50 V, and/or modules rated for maximum system voltage in excess of 50 V, a highly visible warning label regarding the shock hazard is applied near the means of connection to the module. On label / in manual On connectors, additionally marked on label 12 REQUIREMENTS FOR SULIED DOCUMENTS 12.1 The module or panel is supplied with installation instructions describing the methods of electrical and mechanical installation and the electrical ratings of the module. The instructions state the application class under which the module was qualified and any specific limitations required for that application class. 12.2 When the fire rating is dependent on a specific mounting structure, specific spacing, or specific means of attachment to the roof or structure, details of the specific parameter or parameters are included in the instructions. 12.3 The electrical installation instructions include a detailed description of the wiring method. The description of the wiring method includes the following information: Electrical rating given in Datasheet, installation is described in an extra manual Grounding method Size, type, and temperature rating of the conductors Recommended maximum series/parallel module configurations 4 mm 2 V-cable, applicable for 90 minimum 19/1 (N1-types, 60 cells), 22/1 (N9-types, 54 cells) Type of over-current protection and diode bypassing to be used Minimum cable diameters when the wiring method is cable 20 A 4 mm 2

age 47 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict Any limitations on wiring methods that apply to the wiring compartment or box 12.4 The mechanical installation instructions for roof mounting include: A statement indicating the minimum mechanical means for securing the module or panel to the roof A statement that the assembly is to be mounted over a fire resistant roof covering rated for the application (only for non-integral modules or panels) Indication of any slope required for maintaining a fire class rating 12.5 The installation instructions include a statement advising that artificially concentrated sunlight shall not be directed on the module or panel. 12.6 Assembly instructions are provided with a product shipped in subassemblies, and are detailed and adequate to the degree required to facilitate total assembly of the product. 12.7 The installation instructions include the proposed statement given in this Sub clause (or equivalent) to allow for increased output of the module resulting from certain conditions of use. In manual

age 48 of 186 Test Report Ref. No.: VDE 208039-ET2-1 ATTACHMENT TO TEST REORT IEC 61730-1A EUROEAN GROU DIFFERENCES AND NATIONAL DIFFERENCES (hotovoltaic (V) module safety qualification - art 1: Requirements for construction) Differences according to...: EN 61730-1: 2007 Attachment Form No....: EU_GD_IEC61730-1A Attachment Originator... : TÜV SÜD roduct Service GmbH Master Attachment...: 2011-07 Copyright 2011 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. Clause Requirement + Test Result - Remark Verdict General Replace all references to this part of IEC 61730 and IEC 61730-2 by this part of EN 61730 and EN 61730-2 Considered 3.2 CLASS A: GENERAL ACCESS, HAZARDOUS VOLTAGE, HAZARDOUS OWER ALICATIONS Replace the text by: Considered Modules rated for use in this application class may be used in systems operating at greater than 120 V DC. Modules qualified for safety through this part of EN 61730 and EN 61730-2 within this application class are considered to meet the requirements for safety class II. Voltage (V) : Considered 3.4 CLASS C: LIMITED VOLTAGE Replace the text by: Considered Modules rated for use in this application class are restricted to systems operating at less than 120 V DC. Modules qualified for safety through this part of EN 61730 and EN 61730-2 within this application class are considered to meet the requirements for safety class Ill. Voltage (V) : Considered Note: Safety class are defined within EN 61140 Considered 5.1 GENERAL Replace the second paragraph by: Exception: Encapsulation materials (such as EVA, V, TU etc.) are not required to meet these requirements. Considered 5.2 olymers serving as an enclosure for live parts In item c), replace ANSI/UL 746C by EN ISO 4892 series. Considered

age 49 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Clause Requirement + Test Result - Remark Verdict 5.3 olymers serving to support live parts In item b), replace 250 V by 250. Considered Add the following notes: Considered Note 1: olymeric materials having a CTI of 250 or more fall within insulation class IIIa of EN 60664-1. Note 2: The use of polymeric materials requires consideration of the system voltage rating and pollution class. In this context Table 4 of EN 60664-1 shall be referenced. Delete item c). Considered In item d), replace ANSI/UL 746C by EN ISO Considered 4892 series. Renumber the note into note 3. Considered 5.4 olymers serving as an outer surface 5.4.3 Replace ANSI/UL 746C by EN ISO 4892 series. Considered 7.3 Connectors Add the following sentence: Considered The standardization of connectors for V application is an ongoing activity in CENELEC. This sub clause will be superseded by a future European Standard. 7.3.1 Replace IEC 60130 series by IEC 61984. Considered 7.3.3 Replace IEC 61721 series by IEC 60512-5-1 and EN 60512-5-2. Considered 11 MARKING Considered Add the following sentence: Considered The marking should be done in conformance with EN 50380. 11.1 Add to the list: Considered Application class of the product Considered For class A modules, the Safety Class II symbol (see IEC 60417, symbol 5172). Considered

age 50 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Test Report issued under the responsibility of: TEST REORT IEC 61730-2 V Module Safety Qualification art 2: Requirements for testing Test Report Reference No.... : 208039-ET2-1 Date of issue (YYYY/MM/DD)... : 2015/04/22 Total number of pages... : CB/CCA Testing Laboratory... : Address... : Applicant s name... : Address... : 186 (104 pages of this report/ part of CB report) VDE rüf- und Zertifizierungsinstitut GmbH VDE Testing and Certification Institute Merianstrasse 28, D-63069 Offenbach, Germany LG Electronics Inc. 168, Suchul-daero, Gumi-si, Gyeongsangbuk-do, 730-903, Rep. of Korea Test specification: Standard... : IEC 61730-2 Ed. 1, modified + A1 2011 Test procedure... : Non-standard test method..: Test Report Form No.... : TRF Originator... : CB- Scheme IEC61730_2A TÜV Rheinland roduct Safety GmbH Master TRF... : Dated 2007-11, VDE modified 2014-09 Copyright 2007 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-iecee members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. Test item description... : hotovoltaic (V) Module(s) Trade Mark... : Model/Type reference... : Manufacturer... : LGxxxN1W-G4, LGxxxN1C-G4 (xxx 280~340, 5steps) LGxxxN9W-G4, LGxxxN9C-G4 (xxx 270~290, 5steps) LG Electronics Inc. Ratings... : See page 4

age 51 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Testing procedure and testing location: CB/CCA Testing Laboratory: Testing location/ address... : Associated CB Laboratory: Testing location/ address... : Tested by (name + signature)... : Approved by (name + signature). : Testing procedure: CTF stage 1 Tested by (name + signature)... : Approved by (name + signature)... : Testing location/ address... VDE rüf- und Zertifizierungsinstitut GmbH VDE Testing and Certification Institute Section ET2 Merianstrasse 28, D-63069 Offenbach, Germany (Authorization of test report) (Authorization of test report) Testing procedure: CTF stage 2 Tested by (name + signature)... : Kwang-sik Hyoung Witnessed by (name + signature).. : Approved by (name + signature)... : Roland Herbert (Authorization of test report) Jürgen Bärwinkel Testing location/ address...umyeon R&D Campus, 16, Umyeon-dong, Seocho-Gu, Seoul, Korea Testing procedure: SMT Tested by (name + signature)...: Approved by (name + signature)..: Supervised by (name + signature): Testing location/ address... : Testing procedure: RMT Tested by (name + signature)...: Approved by (name + signature)..: Supervised by (name + signature): Testing location/ address... :

age 52 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Summary of testing: Tests performed (name of test and test clause): Full Test, IEC 61730-2 Testing location: See page 1 Summary of compliance with National Differences: See appended Report EUROEAN GROU DIFFERENCES AND NATIONAL DIFFERENCES to IEC 61730-2. Copy of marking plate:

age 53 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Test item particulars... : Accessories and detachable parts included in the evaluation... Mounting system used... : Continuous bar mounting Other options included... :... : ossible test case verdicts: - test case does not apply to the test object... : - test object does meet the requirement... : (ass) - test object does not meet the requirement... : F (Fail) Abbreviations used in the report: CTI Comparative Tracking Index FF Fill factor Ipm Maximum power current Isc Short circuit current MST Module Safety Test max Maximum power D artial Discharge RTI Relative Thermal Index STC Standard Test Conditions TC Thermal Cycling Voc Open circuit voltage Vpm Maximum power voltage Testing Date of receipt of test item... : 2015/01/27 Date (s) of performance of tests... : 2015/01/27 ~ 2015/04/02 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma (point) is used as the decimal separator. This Test Report Form is intended for the investigation of V module in accordance with IEC 61730-2. It can only be used together with IEC 61730-1 Test Report. List of test equipment must be kept on file and available for review. Factory (for information only) Name... : Address... : LG Electronics Inc. 168, Suchul-daero, Gumi-si, Gyeongsangbuk-do, 730-903, Rep. of Korea

age 54 of 186 Test Report Ref. No.: VDE 208039-ET2-1 General product information: V module type reference... : LGxxxN1W-G4 roduct Electrical Ratings at STC Nominal maximum power (max)...: 310 W Nominal short circuit current at (Isc)...: 9,96 A Nominal open circuit voltage at (Voc)...: 40,4 V Nominal maximum power current (Ipm)...: 9,45 A Nominal maximum power voltage (Vpm)...: 32,8 V roduct Safety Ratings Maximum system voltage...: 1000 V Maximum over-current protection rating...: 20 A Safety application class...: A Safety class in accordance with IEC 61140...: II Fire safety class...: C Recommended maximum series/parallel module configurations...: 19/1 Scope of Module Safety Qualification Testing Initial Module Safety Qualification Extension of Module Safety Qualification Original Test Report Ref. No : Change in cell technology Modification to encapsulation system Modification to superstrate Increase in module size Modification to frame and/or mounting structure Modification to junction box/el. termination Change in cell interconnect materials/technique Change in el. circuit of an identical package Modification to backsheet/substrate Higher or lower output by 10% Note (1) Use the General product information field to give any information on model differences within a product type family covered by the test report. Note (2) Use the General product information field to describe the range of electrical and safety ratings, if the TRF covers a type family of modules. Note (3) Use Annex 1 to list the used materials and components of the module (manufacturer/supplier and type reference)

age 55 of 186 Test Report Ref. No.: VDE 208039-ET2-1 TEST SEQUENCES FOR MODULE SAFETY TESTING UNDER IEC 61730-2

age 56 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict 3 ALICATION CLASSES The module has been evaluated for the following Application Class (Class A, B, C)... : Class A REQUIRED TESTS DEENDING ON THE ALICATION CLASS Application Class A B C * * - - - - - Module Safety Test reconditioning tests: MST 51 Thermal cycling (TC50 or TC200) MST 52 Humidity freeze MST 53 Damp heat MST 54 UV resistance General inspection test: MST 01 Visual Inspection Electrical shock hazard tests: MST 11 Accessibility test MST 12 Cut Susceptibility test MST 13 Ground Continuity test MST 14 Impulse Voltage test MST 16 Dielectric Withstand test MST 17 Wet Leakage Current test MST 42 Robustness of terminations ** - - - - - - - Fire Hazard tests: MST 21 Temperature test MST 22 Hot spot test MST 23 Fire test MST 26 Reverse current overload test Mechanical stress tests: MST 32 Module breakage test MST 34 Mechanical load test Component tests: MST 15 artial discharge test MST 33 Conduit bending MST 44 Terminal box knockout test Legend: Test required - Test not required * Different test levels for Application class A and B ** Minimum Fire Resistance Class C is necessary for building roof-mounted modules.

age 57 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict 6 SAMLING The modules tested (modules and laminate) were taken at random from a production batch and subjected to manufacturer s normal quality control and inspection for safety testing The modules tested (modules and laminate) were prototypes of a new design and not taken from a production batch. reconditioning of test samples was performed within IEC 61215 or IEC 61646 performance testing reconditioning of test samples was performed separately from IEC 61215 or IEC 61646 performance testing List of test samples Sample No. Type/model Remark 1 LG310N1W-G4 C1501062 (Control) 2 LG310N1W-G4 C1501063 (MST22, MST25) 3 LG310N1W-G4 C1501006 (MST11, MST12, MST13, MST42, MST51b, MST52, MST54) 5 LG310N1W-G4 C1501067 (MST11, MST12, MST13, MST51a) 7-1 LG310N1W-G4 C1501025 (MST11, MST12, MST13, MST34, MST53) 7-2 LG310N1W-G4 C1501026 (MST11, MST13, MST34, MST53) 9 LG310N1W-G4 C1501070 (MST11, MST12, MST13, MST14) 10 LG310N1W-G4 C1501071 (MST32) 11 LG310N1W-G4 C1501073 (MST21, MST26)

age 58 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict 9 ASS CRITERIA The module under evaluation was judged to have passed all safety qualification test. The test samples met all of the criteria of each individual safety test. See appended Tables 10 TEST ROCEDURES Safety qualification testing included the following Module Safety Tests (MST) of IEC 61730-2: 10.1 MST 01 Visual inspection... : See appended Table 10.1 10.2 MST 11 Accessibility test... : See appended Table 10.2 10.3 MST 12 Cut susceptibility test... : See appended Table 10.3 10.4 MST 13 Ground continuity test... : See appended Table 10.4 10.5 MST 14 Impulse voltage test See appended Table 10.5 10.6 MST 16 Dielectric withstand test... : See appended Table 10.6 10.7 MST 21 Temperature test... : See appended Table 10.7 10.8 MST 23 Fire test... : Fire test with Toray backsheet has been already perfomed with project #172987, CB/ DE1 51577 10.9 MST 26 Reverse current overload Test... : See appended Table 10.9 10.10 MST 32 Module breakage test... : See appended Table 10.10 Component Tests 11.1 MST 15 artial discharge test... : Approved by TUV Rheinland 11.2 MST 33 Conduit bending test... : - 11.3 MST 44 Terminal box knockout test... : -

1 2 3 5 7-1 7-2 11 10 9 age 59 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Overview of MST items for each test sample MST item Sample No. Control module MST 01 Visual inspection MST 11 Accessibility test MST 12 Cut susceptibility test MST 13 Ground continuity test MST 14 Impulse voltage test MST 15 artial discharge test MST 16 Dielectric withstand test MST 17 Wet leakage current test MST 21 Temperature test MST 22 Hot-spot test MST 23 Fire test MST 25 Bypass diode thermal test MST 26 Reverse current overload test MST 32 Module breakage test MST 33 Conduit bending test MST 34 Mechanical load test MST 42 Robustness of terminations MST 44 Terminal box knock out test MST 51b Thermal cycling test (TC50) MST 51a Thermal cycling test (TC200) MST 52 Humidity freeze test MST 53 Damp heat test MST 54 UV preconditioning test Legend: n Test performed, where n gives the sequence of testing (n =1, 2 etc.)

age 60 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Table 10.1 MST 01 VISUAL INSECTION Sample No. osition in test sequence: 2 Initial examination No findings reconditioning: MST 25, MST 22 MST 12, Cut susceptibility test Final examination No findings 3 Initial examination No findings reconditioning: MST 54, MST 51b, MST 52, MST 42 MST 12, Cut susceptibility test Final examination No findings 5 Initial examination No findings reconditioning: MST 51a MST 12, Cut susceptibility test Final examination No findings 7-1 Initial examination No findings reconditioning: MST 53, MST 34 MST 12, Cut susceptibility test Final examination No findings 7-2 Initial examination No findings reconditioning: MST 53, MST 34 Final examination No findings 9 Initial examination No findings MST 14, Impulse voltage test Final examination No findings 11 Initial examination No findings MST 21, Temperature test MST 26, Reverse current overload Final examination No findings

age 61 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Table 10.2 MST 11 ACCESSIBILITY TEST Sample No. osition in test sequence: 3 Initial examination No access reconditioning: MST 54, MST 51b, MST 52, MST 42 MST 12, Cut susceptibility test Final examination No access 5 Initial examination No access reconditioning: MST 51a MST 12, Cut susceptibility test Final examination No access 7-1 Initial examination No access reconditioning: MST 53, MST 34 MST 12, Cut susceptibility test Final examination No access 7-2 Initial examination No access 9 Initial examination No access

age 62 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Table 10.3 MST 12 CUT SUSCETIBILITY TEST Applied force (N)... : 8,9 Sample No. 3 No visual evidence that the superstrate or substrate have been cut No exposure of active circuitry of the module Requirement of MST 13, MST 16, MST 17 are met (see appended Tables 10.4, 10.6, MST17) 5 No visual evidence that the superstrate or substrate have been cut No exposure of active circuitry of the module Requirement of MST 13, MST 16, MST 17 are met (see appended Tables 10.4, 10.6, MST17) 7-1 No visual evidence that the superstrate or substrate have been cut No exposure of active circuitry of the module Requirement of MST 13, MST 16, MST 17 are met (see appended Tables 10.4, 10.6, MST17)

age 63 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Table 10.4 MST 13 GROUND CONTINUITY TEST Maximum over-current protection rating (A)... : 20 Current applied (A)... : 50 Location of designated grounding point... : See manual Location of second contacting point... : See manual Sample No. osition in test sequence: Voltage (V) Resistance ( ) 3 Initial examination 0,527 0,0105 reconditioning: MST 54, MST 51b, MST 52, MST 42 MST 12, Cut susceptibility test Final examination 0,153 0,0031 5 Initial examination 0,129 0,0026 reconditioning: MST 51a MST 12, Cut susceptibility test Final examination 0,170 0,0034 7-1 Initial examination 0,086 0,0017 reconditioning: MST 53, MST 34 MST 12, Cut susceptibility test Final examination 0,169 0,0034 7-2 Initial examination 0,051 0,0010 9 Initial examination 0,228 0,0046 Table 10.5 MST 14 IMULSE VOLTAGE TEST Sample No. Maximum system voltage (V)... : 1000 Impulse voltage (V)... : 8000 Thickness of conductive foil (mm)... : 0,07 (with glue) 9 No evidence of dielectric breakdown or surface tracking observed No evidence of major visual defects (See appended table 10.1)

age 64 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Table 10.6 MST 16 DIELECTRIC WITHSTAND TEST Maximum system voltage (V d.c.)... : 1000 Test voltage applied (V d.c.)... : 1000 / 6000 Minimum allowable insulation resistance (MΩ)... : 25 Sample No. osition in test sequence: Dielectric breakdown Insulation resistance (MΩ) 3 Initial test... : >999 MST 54, MST 51b, MST 52, MST42 reconditioning Intermediate test... : >999 MST 12, Cut susceptibility test MST Final test... : >999 5 Initial test >999 MST 51a reconditioning Intermediate test >999 MST 12, Cut susceptibility test MST Final test >999 7-1 Initial test >999 MST 53, MST 34 reconditioning Intermediate test >999 MST 12, Cut susceptibility test MST Final test >999 7-2 Initial test >999 MST 53, MST 34 reconditioning Final test >999 9 Initial test >999 MST 14, Impulse voltage test MST Final test >999 11 Initial test >999 MST 21, MST 26 MST Final test >999

age 65 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Table 10.7 MST 21 TEMERATURE TEST Measuring location: Sample No.... : 11 Reference solar irradiance (W/m²)... : 1000 W/m² Reference ambient temperature ( C)... : 40 (Open 23,1 / Short 23,3) Mounting platform surface underneath centre cell Module open-circuited Component temperature T OBS ( C) Normalized temperature T CON ( C) Component temperature limit ( C) 42,0 59,8 90 Substrate backsheet behind area of centre cell 70,9 87,8 110 Module output leads 40,9 57,8 90 J-box inside surface(base) 44,9 61,8 90 Field wiring connection or connector 41,4 58,3 90 Backsheet beneath J-box 60,1 77,0 110 ositive terminal block 47,5 64,4 90 ositive wiring lead inside junction box 49,9 66,8 90 Frame 50,4 67,3 90 Mounting platform surface (wood) 48,8 65,7 90 Diode #1 case 51,5 68,4 188 Diode #2 case 52,5 69,4 188 Diode #3 case 51,5 68,4 188 Superstrate glass surface 69,7 86,6, Glass Mounting platform surface underneath centre cell Measuring location: Mounting platform surface underneath centre cell Module short-circuited 42,9 59,8 90 Component temperature T OBS ( C) Normalized temperature T CON ( C) Component temperature limit ( C) 44.3 61.0 90 Substrate backsheet behind area of centre cell 68.3 85.0 110 Module output leads 42 58.7 90 J-box inside surface(base) 42.3 59.0 90 Field wiring connection or connector 41.2 57.9 90 Backsheet beneath J-box 55.2 71.9 110 ositive terminal block 44.9 61.6 90 ositive wiring lead inside junction box 47.3 64.0 90 Frame 48.6 65.3 90

age 66 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Mounting platform surface (wood) 49.5 66.2 90 Diode #1 case 48.7 65.4 188 Diode #2 case 49.7 66.4 188 Diode #3 case 49.1 65.8 188 Superstrate glass surface 65.5 82.2, Glass T CON = T OBS + (40 C T AMB ) Temperature limits are given in Table 9 of IEC 61730-2.

age 67 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Table 10.8 MST 23 FIRE TEST Module fire resistance class (A, B, C)... : No. of modules provided to create the test assembly... : Sample No. The module complies with the requirements for the fire resistance class Table 10.9 MST 26 REVERSE CURRENT OVERLOAD TEST Module over-current protection rating (A)... : 20 Test current (A)... : 27,0 Range of applied voltage (V)... : 50 Test duration... : 2 hours Sample No. 9 No flaming of the module No flaming or charring of the cheesecloth No flaming of the tissue paper MST 17 requirements fulfilled (see appended Table MST17) Maximum temperature is 82,2 C

age 68 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Table 10.10 MST 32 MODULE BREAKAGE TEST Weight of impactor (kg)... : 45 Thickness of sample (mm)... : 40 Mounting technique used... : Schletter Sample No. Module breakage... : Weight of particles in case of breakage (g)... : No breakage Breakage at 300 mm Breakage at 450 mm Breakage at 1220 mm 10 Breakage occurred, but no shear or opening large enough for a 76 mm diameter sphere to pass freely has developed. Disintegration occurred, but the ten largest crack-free particles selected 5 min subsequent to the test didn t weigh more in grams than 16 times the thickness of the sample in millimeters. Breakage occurred, but no particles larger than 6,5 cm² have been ejected from the sample.

age 69 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Table MST 17 MST 17 WET LEAKAGE CURRENT TEST Maximum system voltage (V)...: 1000 Test voltage applied V TEST (V d.c.)...: 1000 Module area A (m²)...: 1,64 Resistivity of wetting agent (Ω cm)...: < 3500 Average wetting agent temperature ( C)...: 23 Sample No. osition in test sequence: Insulation resistance at V TEST (MΩ) Required Insulation resistance (M ) 2 Initial test >999 25 MST 25 >999 25 MST 22 >999 25 3 Initial test >999 25 MST 54, MST 51b, MST 52, MST 42 reconditioning MST 12, Cut Susceptibility >999 25 5 Initial test >999 25 MST 12, Cut Susceptibility >999 25 7-1 Initial test >999 25 MST 53, Damp Heat >999 25 MST 34, Mechanical Load Test >999 25 MST 12, Cut Susceptibility >999 25 7-2 Initial test >999 25 MST 53, Damp Heat >999 25 MST 34, Mechanical Load Test >999 25 9 Initial test >999 25 11 MST 26, Reverse Current Overload >999 25

age 70 of 186 Test Report Ref. No.: VDE 208039-ET2-1 ATTACHMENT TO TEST REORT IEC 61730-2 EUROEAN GROU DIFFERENCES AND NATIONAL DIFFERENCES (hotovoltaic (V) module safety qualification - art 2: Requirements for testing) Differences according to : EN 61730-2: 2007 Attachment Form No. : EU_GD_IEC61730-2A Attachment Originator : TÜV SÜD roduct Service GmbH Master Attachment : 2011-07 Copyright 2008 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. Clause Requirement + Test Result - Remark Verdict General Replace all references to IEC 61730-1, IEC 61730-2 and this part of IEC 61730 by EN 61730-1, EN 61730-2 and this part of EN 61730. Considered 3.2 CLASS A: GENERAL ACCESS, HAZARDOUS VOLTAGE, HAZARDOUS OWER ALICATIONS Replace the text by: Considered Modules rated for use in this application class may be used in systems operating at greater than 120 V DC. Modules qualified for safety through EN 61730-1 and this part of EN 61730 within this application class are considered to meet the requirements for safety class II. Voltage (V) : Considered 3.4 CLASS C: LIMITED VOLTAGE Replace the text by: Considered Modules rated for use in this application class are restricted to systems operating at less than 120 V DC. Modules qualified for safety through EN 61730-1 and this part of EN 61730 within this application class are considered to meet the requirements for safety class Ill. Voltage (V) : Considered Note: Safety class are defined within EN 61140 Considered 5 ALICATION CLASSES AND THEIR NECESSARY TEST ROCEDURES Table 7 Delete MST 23 from the row referring to Fire test and replace the content of footnote ** by: ** A European fire test is under consideration. Considered 8 TESTING Figure 1 Delete MST 23 from the box referring to Fire test and add * referring to a footnote reading: * A European fire test is under consideration. Considered

age 71 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Clause Requirement + Test Result - Remark Verdict 10 TEST ROCEDURES 10.4 Ground continuity test MST 13 10.4.2 Renumber the note into NOTE 1. Considered Add the following notes: Considered NOTE 2: The maximum over-current protection Considered rating of a module can be interpreted as the module series fuse rating. A series fuse may be required in the installation of V arrays. According to sub clause 12.2 of EN 61730-1 the maximum over-current protection rating has to be provided by the manufacturer. NOTE 3: A procedure for determination of maximum reverse current is described in EN 50380. Considered 10.8 Fire test MST 23 Replace entire sub clause by: 10.8 Fire test Under consideration. Considered 10.9 Reverse current overload Test MST 26 10.9.2 Renumber the note into NOTE 1. Considered Add the following notes: NOTE 2: The maximum over-current protection rating of a module can be interpreted as the module series fuse rating. A series fuse may be required in the installation of V arrays. According to sub clause 12.2 of EN 61730-1 the maximum over-current protection rating has to be provided by the manufacturer. Considered 10.10 Module breakage test MST 32 Add the following notes: NOTE: If the glass is qualified in accordance with EN 12150-1 this test can be omitted. Considered 11 COMONENT TESTS 11.1 MST 15 artial discharge test 11.1.2 Replace the text by: Considered It is advisable to perform the partial discharge-test before using the back sheet foil in the V module construction. NOTE: In order to achieve a certain statistical Considered relevance 10 pieces should undergo the test. The size of the specimen depends on requirement originating from the test apparatus. 11.1.3 Add the following sentence: The geometry of the electrodes shall be in conformance with EN 60243-1. Considered

age 72 of 186 Test Report Ref. No.: VDE 208039-ET2-1 11.1.4 In item a) add the following notes: Considered NOTE 1: Any voltage below maximum systems voltage can be used but the test should start at zero voltage because it may happen that maximum systems voltage is not stated or unknown. NOTE 2: When increasing the test voltage partial discharges may appear periodically. In that case, the inception voltage is the test voltage at which permanent discharges occur for a duration of at least 60 s. In item b) add the following notes: Considered NOTE 3: Because partial discharges can disappear periodically, partial discharges at extinction voltage should stay below 1 pc for minimum of 60 s In item e) replace Uoc by Voc Considered

age 105 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Test Report issued under the responsibility of: TEST REORT IEC 61215: 2005 2nd Edition Crystalline Silicon Terrestrial hotovoltaic (V) Modules - Design Qualification and Type Approval Test Report Reference No....: 208039-ET2-1 revious report no.: 208040-ET2-1 dated 2015/04/16 Date of issue (YYYY/MM/DD)...: 2015/04/22 Total number of pages...: 186 (82 pages of this report/ part of CB report) CB Testing Laboratory...: VDE rüf- und Zertifizierungsinstitut GmbH VDE Testing and Certification Institute Address...: Merianstrasse 28, D-63069 Offenbach Testing location/procedure...: CBTL RMT SMT CTF stage 1 stage 2 Address...: LG Electronics Inc. Umyeon R&D Campus, 16, Umyeon-dong, Seocho-Gu, Seoul, Korea Applicant s name...: LG Electronics Inc. Address...: 168, Suchul-daero, Gumi-si, Gyeongsangbuk-do, 730-903, Rep. of Korea Test specification... : Standard...: IEC 61215: 2005 2nd Edition Test procedure...: CB- Scheme Non-standard test method...: Test Report Form No....: IEC61215C Test Report Form Originator...: Underwriters Laboratories Inc. Master TRF...: Dated 2007-03, VDE modified 2014-09 CB-Full Certification Scheme Copyright 2007 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-iecee members, the IECEE/IEC logo shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. Test item description... : hotovoltaic (V) Module(s) Trade Mark...: Model/Type reference...: LGxxxN1K-G4 (xxx 280~330, 5steps) Manufacturer...: LG Electronics Inc. Ratings...: See page 4

age 106 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Testing procedure and testing location: CB Testing Laboratory: VDE rüf- und Zertifizierungsinstitut GmbH VDE Testing and Certification Institute Testing location/ address... : Section ET2 / 110720 Merianstrasse 28, D-63069 Offenbach, Germany Associated CB Test Laboratory: Testing location/ address... : Tested by (name + signature)... : (Authorization of test report) Approved by (name + signature)... : Testing procedure: CTF stage 1 Tested by (name + signature)... : (Authorization of test report) Approved by (name + signature)... : Testing location/ address... : Testing procedure: CTF stage 2 Tested by (name + signature)... : Kwang-sik Hyoung Witnessed by (name + signature).. : Roland Herbert (Authorization of test report) Approved by (name + signature)... : Jürgen Bärwinkel Testing location/ address... : Umyeon R&D Campus, 16, Umyeon-dong, Seocho-Gu, Seoul, Korea Testing procedure: SMT Tested by (name + signature)...: Approved by (name + signature)...: (Authorization of test report) Supervised by (name + signature).: Testing location/ address... : Testing procedure: RMT Tested by (name + signature)...: Approved by (name + signature)...: (Authorization of test report) Supervised by (name + signature).: Testing location/ address... : CB/ DE1-55514

age 107 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Summary of testing: Tests performed (name of test and test clause): Testing location: Retest clause e) Backsheet(V-BS MGEW-SbR, V-BS MGEW-SbR) addition, Black string connector (Black 0.3-5.0, Sn-b, 40 μm) addition. Both backsheets have identical chemical, electrical and physical properties. Due to engineering decision only the V-BS MGEW-SbR backsheet was tested. The testing on the black patterned back sheet BS V-BS MGEW-SbR was omitted since it was considered less critical all black version. Testing procedure New module type See page 1 Modifications (if yes, please choose the applicable modification according to the Retesting Guideline) to Basic Test Report: 208039-ET2-1 Change in cell technology Modification to encapsulation system Modification to superstrate Increase in module size Modification to backsheet/ substrate Modification to frame and/ or mounting structure Modification to junction box/ electrical termination Change in cell interconnect materials or technique Change in electrical circuit of an identical package Higher or lower power output (by 10%) in the identical package including size and using the identical cell process Qualification of a frameless module after the design has received certification as a framed module Change in bypass diode or number of diodes Testing Date of receipt of test item : 2015/01/27 Date (s) of performance of tests : 2015/01/27 ~ 2015/03/23 Module group assignment: Sample # Sample Group ID Sample S/N 1 A C1501074 3 C1 C1501076 4 C2 C1501077 7-1 E1 C1501059 7-2 E1 C1501060 8 E2 C1501040 9 MST C1501078 11 MST C1501079 CB/ DE1-55514

age 108 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Test item particulars: Accessories and detachable parts included in the evaluation... : -- Options included...: -- ossible test case verdicts: - test case does not apply to the test object...: - test object does meet the requirement...: ass () - test object does not meet the requirement...: Fail (F) Abbreviations used in the report: HF Humidity Freeze DH Damp Heat Imp Maximum power current Isc - Short circuit current mp Maximum power NOCT Nominal Operating Cell Temperature STC Standard Test Conditions TC Temperature Cycling Vmp Maximum power voltage Voc Open circuit voltage FF Fill Factor α Current temperature coefficient β Voltage temperature coefficient δ power temperature coefficient General remarks: "This report is not valid as a CB Test Report unless appended to a V-CB Conformity Assessment Certificate issued by a NCB, in accordance with IECEE 02 and IECEE 03". "(See Enclosure #)" refers to additional information appended to the report. "(See table)" refers to a table appended to the report. Throughout this report a point is used as the decimal separator. The tests results presented in this report relate only to the object tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. List of test equipment must be kept on file and available for review. Summary of compliance with National Differences: General product information and considerations: roduct Electrical Ratings: Module type LGxxxN1K-G4 Isc (Adc) 9,53 9,94 Voc (Vdc) 38,1 41,6 Imp (Adc) 9,04 9,47 Vmp (Vdc) 31,0 34,9 mp (W) 280 330 Maximum system voltage (V) Series Fuse Rating (A) 1000 20 CB/ DE1-55514

age 110 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Copy of marking plate: CB/ DE1-55514

age 111 of 186 Test Report Ref. No.: VDE 208039-ET2-1 hotos of the module (front and back): hotos of the junction box: hotos of the connector: CB/ DE1-55514

age 112 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10 TEST ROCEDURES (if it is not a full test, strikethrough non-performed test) Note: Deviations from test sequence are possible but must be documented. 5 Modules reconditioning 10.1 Visual Inspection 10.2 Maximum ower determination 10.3 Insulation test 10.15 Wet leakage current test A B C1 C2 D1 D2 E1 E2 10.4 Measurement of temperature coefficients α, β and δ 10.10 UV-test 10.11 Thermal cycling test 200 cycles -40 c to + 85 C 10.13 Damp heat test 1000h 85 C 85% RH 10.5 NOCT 10.11 Thermal cycling test 50 cycles -40 c to + 85 C 10.16 Mechanical load test 10.17 Hail test 10.6 erformance at NOCT 10.12 Humidity-freeze test 10 cycles -40 C to +85 C C 1 10.7 erformance at low irradiance 10.14 Robustness of terminations test 10.8 Outdoor exposure 60kWh/m² 10.18 Bypass-diode test 10.9 Hot-spot endurance test 10.15 Wet leakage current test CB/ DE1-55514

age 113 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61215 Ed.2 Design qualification and type approval Clause Requirement + Test Result - Remark Verdict 4 MARKING Name, monogram or symbol of manufacturer... : Type or model number... : LG300N1W-G4 Serial number... : Yes olarity of terminals or leads... : + and - mark on connectors Maximum system voltage... : 1000 V The date and place of manufacture... : Traceable by serial number Initial examination All modules 10 reconditioning...: 5 kwh/ m2 10.1 Visual inspection...: See table 10.1 Int 10.2 Maximum power determination...: See table 10.2 Int 10.3 Insulation test...: See table 10.3 Int 10.15 Wet leakage current test See table 10.15 Int Group A Control Module Sample Group ID A CB/ DE1-55514

age 114 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61215 Ed.2 Design qualification and type approval Clause Requirement + Test Result - Remark Verdict Group C 2 Modules Sample Group ID C1, C2 10.10 UV test...: 15 kwh/m² Final measurements See table 10.10 C 10.11 Thermal cycling test (50 cycles)...: Final measurements See appended table 10.11 C 10.12 Humidity freeze (10 cycles)... : Final measurements See table 10.12 C Group C1 1 Module Sample Group ID C1 10.14 Robustness of terminations test... : Final measurements See table 10.14 C1 Group E 3 Modules Sample Group ID E1, E2 10.13 Damp heat test... : Final measurements See table 10.13 E Group E1 2 Modules Sample Group ID E1 10.16 Mechanical load test...: 10.16.4 -No open-circuits or ground faults detected Final measurements See table 10.16 E1 Final measurement All modules 10.15 Wet leakage current test See table 10.15 F 10.2 Maximum power determination (final) See table 10.2 F CB/ DE1-55514

age 115 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.1 Int TABLE: Visual inspection (Initial) Test Date (YYYY/MM/DD)...: 2015/01/27 2015/03/02 Sample # Nature and position of initial findings comments or attach photos 1 No findings 3 No findings 4 No findings 7-1 No findings 7-2 No findings 8 No findings 9 No findings 11 No findings 10.2 Int TABLE: Maximum power determination (initial) Test Date (YYYY/MM/DD)...: 2015/01/27 2015/03/02 Module temperature ( C)...: 25 Irradiance (W/m 2 )...: 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) 1 9,74 40,7 9,25 33,3 308,4 77,8 3 9,78 40,6 9,27 33,4 309,3 77,9 4 9,75 40,7 9,24 33,3 307,9 77,6 7-1 9,74 40,7 9,23 33,4 307,9 77,7 7-2 9,77 40,6 9,25 33,2 306,9 77,3 8 9,75 40,6 9,27 33,3 308,6 78,0 9 9,75 40,6 9,24 33,4 308,8 78,0 11 9,79 40,6 9,28 33,4 310,1 78,0 CB/ DE1-55514

age 116 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.3 Int Table: Insulation test (initial) Test Date (YYYY/MM/DD)...: 2015/01/27 2015/03/02 Test Voltage applied (V, DC)...: 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 1 > 999 25 -- 3 > 999 25 -- 4 > 999 25 -- 7-1 > 999 25 -- 7-2 > 999 25 -- 8 > 999 25 -- 9 > 999 25 -- 11 > 999 25 -- Size of module 1,64 m². 10.15 Int TABLE: Wet leakage current test (Initial) Test Date (YYYY/MM/DD)...: 2015/01/27 2015/03/02 Test Voltage applied (V, dc)...: 1000 Solution resistivity (Ω cm)... : < 3500 Ω cm at 22 3 C Surface tension (Nm -2 )...: < 0.03 Nm -2 at 22 3 C Solution temperature ( C)...: 22 Sample # Measured (MΩ) Limit (MΩ) Result 1 > 999 25 3 > 999 25 4 > 999 25 7-1 > 999 25 7-2 > 999 25 8 > 999 25 9 > 999 25 11 > 999 25 Size of module 1,64 m². CB/ DE1-55514

age 117 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.10 C TABLE: UV preconditioning test Test Date (YYYY/MM/DD) start/end... : 2015/01/27 2015/02/03 Module temperature [ C]... : 60 Irradiation total [kwh/ m²]... : 15,0 Sample # Open circuits (yes/no) 3 No 4 No (10.1 Visual inspection after UV preconditioning test) Test Date (YYYY/MM/DD)... : 2015/02/03 Sample # Nature and position of findings comments or attach photos 3 No findings 4 No findings (10.2 Maximum power determination after UV preconditioning test) Test Date (YYYY/MM/DD)... : 2015/02/03 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 3 9,71 40,5 9,18 33,3 305,7 77,7-1,16-5 4 9,70 40,5 9,17 33,2 304,9 77,6-0,97-5 (10.3 Insulation test after UV preconditioning test) Test Date (YYYY/MM/DD)...: 2015/02/03 Test Voltage applied (V, DC)...: 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 3 > 999 25 -- 4 > 999 25 -- Size of module 1,64 m². CB/ DE1-55514

age 118 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.11 C TABLE: Thermal cycling 50 test Test Date (YYYY/MM/DD) start/end... : 2015/02/23 2015/03/04 Total cycles (50)... : 50 Sample # Open circuits (yes/no) 3 No 4 No (10.1 Visual inspection after thermal cycling 50 test) Test Date (YYYY/MM/DD)... : 2015/03/04 Sample # Nature and position of findings comments or attach photos 3 No findings 4 No findings (10.2 Maximum power determination after thermal cycling 50 test) Test Date (YYYY/MM/DD)... : 2015/03/04 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 3 9,70 40,5 9,17 33,2 305,1 77,7-0,20-5 4 9,71 40,5 9,17 33,3 304,8 77,5-0,03-5 (10.3 Insulation test after thermal cycling 50 test) Test Date (YYYY/MM/DD)... : 2015/03/04 Test Voltage applied (V, DC)... : 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 3 > 999 25 -- 4 > 999 25 -- Size of module 1,64 m². CB/ DE1-55514

age 119 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.12 C TABLE: Humidity freeze 10 test Test Date (YYYY/MM/DD) start/end... : 2015/03/06 2015/03/16 Total cycles (10)... : 10 Sample # Open circuits (yes/no) 3 No 4 No (10.1 Visual inspection after humidity freeze 10 test) Test Date (YYYY/MM/DD)... : 2015/03/16 Sample # Nature and position of findings comments or attach photos 3 No findings 4 No findings (10.2 Maximum power determination after humidity freeze 10 test) Test Date (YYYY/MM/DD)... : 2015/03/16 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 3 9,69 40,5 9,13 33,2 303,6 77,4-0,49-5 4 9,69 40,6 9,13 33,2 303,2 77,1-0,52-5 (10.3 Insulation test after humidity freeze 10 test) Test Date (YYYY/MM/DD)... : 2015/03/16 Test Voltage applied (V, DC)... : 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 3 > 999 25 -- 4 > 999 25 -- Size of module 1,64 m². CB/ DE1-55514

age 120 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.14 C1 TABLE: Robustness of terminations test Test Date (YYYY/MM/DD) start/end.. : 2015/03/17 Types of terminations Type A: wire of flying lead Type B: tags, threaded stubs, screws, etc. Type C: connector Applied force in all directions [N]... : 40(Tensile) / 20(Bending) Sample # Open circuits (yes/no) 3 No (10.1 Visual inspection after robustness of terminations test) Test Date (YYYY/MM/DD)... : 2015/03/17 Sample # Nature and position of findings comments or attach photos 3 No findings (10.2 Maximum power determination after robustness of terminations test) Test Date (YYYY/MM/DD)... : 2015/03/17 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 3 9,67 40,5 9,15 33,2 303,5 77,5-0,03-5 (10.3 Insulation test after robustness of terminations test) Test Date (YYYY/MM/DD)... : 2015/03/17 Test Voltage applied (V, DC)... : 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 3 > 999 25 -- Size of module 1,64 m². CB/ DE1-55514

age 121 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.13 E TABLE: Damp heat 1000 test Test Date (YYYY/MM/DD) start/end... : 2015/01/28 2015/03/12 Total hours (1000)... : 1000 Sample # Open circuits (yes/no) 7-1 No 7-2 No 8 No (10.1 Visual inspection after damp heat 1000 test) Test Date (YYYY/MM/DD)... : 2015/03/12 Sample # Nature and position of findings comments or attach photos 7-1 No findings 7-2 No findings 8 No findings (10.3 Insulation test after damp heat 1000 test) Test Date (YYYY/MM/DD)...: 2015/03/12 Test Voltage applied (V, DC)...: 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 7-1 > 999 25 -- 7-2 > 999 25 -- 8 > 999 25 -- (10.15 Wet leakage current test after damp heat 1000 test) Test Date (YYYY/MM/DD)... : 2015/03/12 Test Voltage applied (V, dc)... : 1000 Solution resistivity (Ω cm)... : < 3500 Ω cm at 22 3 C Surface tension (Nm -2 )... : < 0.03 Nm -2 at 22 3 C Solution temperature ( C)... : 23 Sample # Measured (MΩ) Limit (MΩ) Result 7-1 > 999 25 7-2 > 999 25 8 > 999 25 Size of module 1,64 m². CB/ DE1-55514

age 122 of 186 Test Report Ref. No.: VDE 208039-ET2-1 (10.2 Maximum power determination after damp heat 1000 test) Test Date (YYYY/MM/DD)... : 2015/03/12 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 7-1 9,64 40,6 9,10 33,1 301,6 77,1-2,05-5 7-2 9,64 40,5 9,09 33,1 301,6 77,0-2,05-5 8 9,65 40,5 9,11 33,1 301,2 77,1-2,40-5 CB/ DE1-55514

age 123 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.16 E1 TABLE: Mechanical load test Sample #... : 7-1 Test Date (YYYY/MM/DD)... : 2015/03/16, 2015/03/23 Mounting method... : See manual(bolt/nut method) Load applied to... : front side back side Mechanical load [a]... : 2400 / 5400 / 6000 2400 / 5400 First cycle time (start/end)... : 1h 1h Intermittent open-circuit (yes/no)... : No No Second cycle time (start/end)... : 1h 1h Intermittent open-circuit (yes/no)... : No No Third cycle time (start/end)... : 1h (5400 a) 1h Intermittent open-circuit (yes/no)... : No No Fourth cycle time (start/end)... : 1h (6000 a) 1h (5400 a) Intermittent open-circuit (yes/no)... : No No Fourth cycle is extra test for more critical condition (10.1 Visual inspection after mechanical load test) Test Date (YYYY/MM/DD)... : 2015/03/23 Sample # Nature and position of findings comments or attach photos 7-1 No findings (10.2 Maximum power determination after mechanical load test) Test Date (YYYY/MM/DD)... : 2015/03/23 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 7-1 9,60 40,6 9,09 33,2 301,3 77,3-0,10-5 (10.3 Insulation test after mechanical load test) Test Date (YYYY/MM/DD)... : 2015/03/23 Test Voltage applied (V, DC)... : 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 7-1 > 999 25 -- Size of module 1,64 m². CB/ DE1-55514

age 124 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.16 E1 TABLE: Mechanical load test Sample #... : 7-2 Test Date (YYYY/MM/DD)... : 2015/03/16, 2015/03/23 Mounting method... : See manual(clamp method) Load applied to... : front side back side Mechanical load [a]... : 2400 / 5400 / 6000 2400 / 5400 First cycle time (start/end)... : 1h 1h Intermittent open-circuit (yes/no)... : No No Second cycle time (start/end)... : 1h 1h Intermittent open-circuit (yes/no)... : No No Third cycle time (start/end)... : 1h (5400 a) 1h Intermittent open-circuit (yes/no)... : No No Fourth cycle time (start/end)... : 1h (6000 a) 1h (5400 a) Intermittent open-circuit (yes/no)... : No No Fourth cycle is extra test for more critical condition (10.1 Visual inspection after mechanical load test) Test Date (YYYY/MM/DD)... : 2015/03/23 Sample # Nature and position of findings comments or attach photos 7-2 No findings (10.2 Maximum power determination after mechanical load test) Test Date (YYYY/MM/DD)... : 2015/03/23 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Isc (A) Voc (V) Imp (A) Vmp (V) mp (W) FF (%) Degradation (%) Limit (%) 7-2 9,58 40,5 9,05 32,0 298,5 76,9-0,70-5 (10.3 Insulation test after mechanical load test) Test Date (YYYY/MM/DD)... : 2015/03/23 Test Voltage applied (V, DC)... : 1000 / 6000 Sample # Measured Required Dielectric breakdown Result MΩ MΩ Yes (description) No 7-2 > 999 25 -- Size of module 1,64 m². CB/ DE1-55514

age 125 of 186 Test Report Ref. No.: VDE 208039-ET2-1 10.2 F TABLE: Maximum power determination (final) Test Date (YYYY/MM/DD)... : 2015/03/12 2015/03/23 Module temperature ( C)... : 25 Irradiance (W/m 2 )... : 1000 Sample # Voc (V) Vmp (V) Isc (A) Imp (A) mp (W) FF (%) Degradation (%) Limit (%) 1 40,6 33,4 9,66 9,15 305,6 77,9-0,91-8 3 40,5 33,2 9,67 9,15 303,3 77,5-1,94-8 4 40,6 33,2 9,69 9,13 303,2 77,1-1,53-8 7-1 40,6 33,2 9,60 9,09 301,3 77,3-2,14-8 7-2 40,5 33,0 9,58 9,05 298,5 76,9-2,74-8 8 40,5 33,1 9,65 9,11 301,2 77,1-2,40-8 10.15 F TABLE: Wet leakage current test (final) ㅖ Test Date (YYYY/MM/DD)...: 2015/03/12 2015/03/23 Test Voltage applied (V, dc)...: 1000 Solution resistivity (Ω cm)... : < 3500 Ω cm at 22 3 C Surface tension (Nm -2 )...: < 0.03 Nm -2 at 22 3 C Solution temperature ( C)...: 23 Sample # Measured (MΩ) Limit (MΩ) Result 1 > 999 25 3 313 25 4 > 999 25 7-1 > 999 25 7-2 > 999 25 8 > 999 25 Size of module 1,64 m². CB/ DE1-55514

age 126 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Test Report issued under the responsibility of: TEST REORT IEC 61730-1 V Module Safety Qualification art 1: Requirements for construction Test Report Reference No.... : 208039-ET2-1 revious report no.: 208040-ET2-1 dated 2015/04/16 Date of issue (YYYY/MM/DD)... : 2015/04/22 Total number of pages... : CB Testing Laboratory... : Address... : Applicant s name... : Address... : 186 (82 pages of this report/ part of CB report) VDE rüf- und Zertifizierungsinstitut GmbH VDE Testing and Certification Institute Merianstrasse 28, D-63069 Offenbach, Germany LG Electronics Inc. 168, Suchul-daero, Gumi-si, Gyeongsangbuk-do, 730-903, Rep. of Korea Test specification: Standard... : IEC 61730-1 Ed. 1 + A1:2011 + A2:2013 Test procedure... : Non-standard test method..: Test Report Form No.... : TRF Originator... : CB- Scheme IEC61730_1A TÜV Rheinland roduct Safety GmbH Master TRF... : Dated 2007-11, VDE modified 2014-09 Copyright 2007 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-iecee members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. Test item description... : hotovoltaic (V) Module(s) Trade Mark... : Model/Type reference... : Manufacturer... : LGxxxN1K-G4 (xxx 280~330, 5steps) LG Electronics Inc. Ratings... : See page 4 CB/ DE1-55514

age 127 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Testing procedure and testing location: CB/CCA Testing Laboratory: Testing location/ address... : Associated CB Laboratory: Testing location/ address... : Tested by (name + signature)... : Approved by (name + signature). : Testing procedure: CTF stage 1 Tested by (name + signature)... : Approved by (name + signature)... : Testing location/ address... VDE rüf- und Zertifizierungsinstitut GmbH VDE Testing and Certification Institute Section ET2 Merianstrasse 28, D-63069 Offenbach, Germany (Authorization of test report) (Authorization of test report) Testing procedure: CTF stage 2 Tested by (name + signature)... : Kwang-sik Hyoung Witnessed by (name + signature).. : Approved by (name + signature)... : Roland Herbert (Authorization of test report) Jürgen Bärwinkel Testing location/ address...umyeon R&D Campus, 16, Umyeon-dong, Seocho-Gu, Seoul, Korea Testing procedure: SMT Tested by (name + signature)...: Approved by (name + signature)..: Supervised by (name + signature): Testing location/ address... : Testing procedure: RMT Tested by (name + signature)...: Approved by (name + signature)..: Supervised by (name + signature): Testing location/ address... : CB/ DE1-55514

age 128 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Summary of testing: Tests performed (name of test and test clause): Retest clause e) Backsheet(V-BS MGEW-SbR, V-BS MGEW-SbR) addition, Black string connector (Black 0.3-5.0, Sn-b, 40 μm) addition. Both backsheets have identical chemical, electrical and physical properties. Due to engineering decision only the V-BS MGEW- SbR backsheet was tested. The testing on the black patterned back sheet BS V-BS MGEW-SbR was omitted since it was considered less critical all black version. Testing location: See page 1 Summary of compliance with National Differences: See appended Report EUROEAN GROU DIFFERENCES AND NATIONAL DIFFERENCES to IEC 61730-1. Copy of marking plate: CB/ DE1-55514

age 129 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Test item particulars... : Accessories and detachable parts included in the evaluation... : -- Other options included... : --... :... : ossible test case verdicts: - test case does not apply to the test object... : - test object does meet the requirement... : (ass) - test object does not meet the requirement... : F (Fail) Abbreviations used in the report: CTI Comparative Tracking Index FF Fill factor Ipm Maximum power current Isc Short circuit current MST Module Safety Test D artial Discharge STC Standard Test Conditions RTI Relative Thermal Index Voc Open circuit voltage Vpm Maximum power voltage max Maximum power Testing Date of receipt of test item... : 01/27/2015 Date (s) of performance of tests... : 01/27/2015 ~ 03/23/2015 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma (point) is used as the decimal separator. This Test Report Form is intended for the investigation of V module in accordance with IEC 61730-1. It can only be used together with IEC 61730-2 Test Report. List of test equipment must be kept on file and available for review. Factory (for information only) Name... : Address... : LG Electronics Inc. 168, Suchul-daero, Gumi-si, Gyeongsangbuk-do, 730-903, Rep. of Korea CB/ DE1-55514

age 130 of 186 Test Report Ref. No.: VDE 208039-ET2-1 General product information: V module type reference... : LGxxxN1K-G4 roduct Electrical Ratings at STC Nominal maximum power (max)...: 300 W Nominal short circuit current at (Isc)...: 9,70 A Nominal open circuit voltage at (Voc)...: 39,7 V Nominal maximum power current (Ipm)...: 9,26 A Nominal maximum power voltage (Vpm)...: 32,5 V roduct Safety Ratings Maximum system voltage...: 1000 V Maximum over-current protection rating...: 20 A Safety application class...: A Safety class in accordance with IEC 61140...: II Fire safety class...: C Recommended maximum series/parallel module configurations...: 20/1 Scope of Module Safety Qualification Testing Initial Module Safety Qualification Extension of Module Safety Qualification Original Test Report Ref. No : 208039-ET2-1 Change in cell technology Modification to encapsulation system Modification to superstrate Increase in module size Modification to frame and/or mounting structure Modification to junction box/el. termination Change in cell interconnect materials/technique Change in el. circuit of an identical package Modification to backsheet/substrate Higher or lower output by 10% Note (1) Use the General product information field to give any information on model differences within a product type family covered by the test report. Note (2) Use the General product information field to describe the range of electrical and safety ratings, if the TRF covers a type family of modules. Note (3) Use Annex 1 to list the used materials and components of the module (manufacturer, type reference) CB/ DE1-55514

age 131 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict 3 ALICATION CLASSES The module has been evaluated for the following Application Class (Class A, B, C)... : Class A 4 CONSTRUCTION REQUIREMENTS 4.1 General requirements 4.1.1 It is stated that the module is able to operate under environmental condition type AB8 according to IEC 60364-5-51. 4.1.2 The module/s is/are completely assembled when shipped from the factory. The module is provided in subassemblies. 4.1.3 Incorporation of a module into the final assembly does not require any alteration of the module from its originally evaluated form. If YES, specific details describing necessary modification(s) are provided in the installation instructions. 4.1.4 If the module must bear a definite relationship to another module, it is constructed to permit incorporation into the final assembly without the need for alteration. 4.1.5 The construction of the module is such that ground continuity is not interrupted by installation. 4.1.6 arts of the module are prevented from loosening or turning, if such loosening or turning may result in a risk of fire, electric shock, or injury to persons. 4.1.7 Friction between surfaces is not used as the sole means to inhibit the turning or loosening of a part. 4.1.8 Any adjustable or movable structural part is provided with a locking device to reduce the likelihood of unintentional movement. 4.2 Metal parts Metals used in locations that are exposed to moisture shall not be employed alone or in combinations that could result in deterioration, such that the product would not comply with the requirements in this standard. Iron or mild steel serving as a necessary part of the module but not exposed to the weather are plated, painted, or enameled for protection against corrosion. Simple sheared or cut edges and punched holes are not required to be additionally protected. No 5 OLYMERIC MATERIALS CB/ DE1-55514

age 132 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict 5.1 General olymeric materials serving as an enclosure for live metal parts... : olymeric materials serving as support for live metal parts... : olymeric materials serving as the outer surface for the module... : See Sub clause 5.2 See Sub clause 5.3 See Sub clause 5.4 olymeric materials serving as barriers... : See Sub clause 5.5 All polymeric materials have a minimum thermal index (electrical and mechanical, as defined by IEC 60216-5) of 20 C above the maximum measured operating temperature of said material in application, as measured during the Temperature Test MST 21 given in IEC 61730-2. All concerned polymer passed the IEC 61730-2, MST 21 test The RTI of junction box is approved by UL. (E82268, 644(f1)(c)) Considering of minimum thickness (2,0 mm), RTI is 125 (Electrical), 125, 125 (Strength). 5.2 olymers serving as an enclosure for live parts Information is provided that polymers serving as an enclosure for live parts comply with: Junction box separately approved by TUV Rheinland based on EN 50548:2011+A1 (R 50298578) The polymers is approved by UL. (E82268, 644(f1)(c)) -. f1: Suitable for outdoor use with respect to exposure to Ultraviolet Light, Water Exposure and Immersion in accordance with UL 746C a) 5-V flammability rating (IEC 60695-1-1) From the drawing design, the minimum size is 2,25 mm. b) 5-V flammability rating, after water immersion and exposure of the end-product (IEC 60695-1-1) V-0, 5VA is applied for 2,0 mm The enclosure for live parts is not immersed in the water. But this material is suitable for water immersion based on UL approval c) Ultraviolet radiation resistance (ANSI/UL 746C) No direct UV. This part is shaded. But this material is suitable for outdoor UV radiation based on UL approval d) Minimum hot wire ignition rating of 30 (IEC 60695-1-1) For 2,0 mm, LC assigned is 2. HWI range mean ignition time is 30 s through 59 s CB/ DE1-55514

age 133 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict 5.3 olymers serving to support live parts Information is provided that polymers serving to support live parts comply with: a) Flammability classification and high-current arc ignition rating (IEC 60695-1-1) as given in Table 1 of IEC 61730-1 Junction box separately approved by TUV Rheinland based on EN 50548:2011+A1 (R 50298578) The minimum thickness is over 2,25 mm. The flammability classification is V-0, 5VA. Material s assigned LC is 0. So, HAI range mean number of arcs is 120. b) Comparative Tracking Index (CTI) 250 V Comparative Tracking Index (IEC 60112) : c) Inclined plane tracking rating of 1 h, using the time to track method at 2.5 kv (ASTM D2303), if the maximum system operating voltage rating is in the range 600 1500 V. The IT is 120 min at 1.5 kv Maximum system operating voltage rating (V): 1000 V d) Ultraviolet radiation resistance (ANSI/UL 746C) No direct UV. This part is shaded. 5.4 olymers serving as an outer surface Information is provided that polymeric substrates or superstrates used in the module have: 5.4.1 a) A thermal index, both electrical and mechanical, as determined in accordance with IEC 60216 of at least 90 C. b) A thermal index of at least 20 C above the maximum measured operating temperature of the material as measured during the Temperature Test MST21 of IEC 61730-2. 5.4.2 olymeric materials that serve as the outer enclosure for a module that (1) is intended to be installed in a multi-module or -panel system or (2) have an exposed surface area greater than 1 m² or a single dimension larger than 2 m, has a maximum flame spread index of 100 as determined under ASTM E162-1990. 5.4.3 If exposed to direct sunlight in the application, the polymeric material has been evaluated for ultraviolet (UV) radiation resistance as determined in accordance with ANSI/UL 746C. 5.4.4 olymeric materials intended for use as a superstrate or substrate, without appropriate IEC insulation pre-qualification, comply with the requirements of the artial Discharge Test MST 15 of IEC 61730-2. Middle layer of DN backsheet type V-BS MGEW-S is Toray, Lumirror M70 with RTI 125 (UL file E86511) D test by TUV Rheinland for system voltage 1075 Vdc 5.5 olymers serving as barriers CB/ DE1-55514

age 134 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict Insulation barriers are of adequate thickness and of a material appropriate for the application, as defined by IEC 61140 Barriers or liners are held in place and are not adversely affected See Annex 2 for technical details 5.6 olymers serving as structural glazing materials olymers serving as structural glazing materials comply with the requirements for safety glazing by material certification (ANSI Z97.1-93) or by testing in accordance with Module Breakage Test MST 32 of IEC 61730-2. Tested according to MST 32 6 INTERNAL WIRING AND CURRENT-CARRYING ARTS Any current-carrying part and wiring has the mechanical strength and current-carrying capacity necessary for its application. 6.1 Internal wiring 6.1.1 Wiring used within a module has an insulation rating for a minimum of 90 C, with a gauge and voltage rating acceptable for the application as defined by the requirements of IEC 60189-2. 6.1.2 The wiring of a module is located so that after installation of the module in the intended manner the insulation is not exposed to degrading effects of direct sunlight. Cable is separately approved by TUV Rheinland (R 50205246) based on 2 fg 1169/08.07 and by UL based on UL Subject 4703(E343893) The insulation rating temperature is 90 6.2 Splices Splices are insulated equivalent to that required for the wiring involved. No splices is present 6.3 Mechanical Securement 6.3.1 Joints or connections are mechanically secure and provide electrical contact without strain on connections and terminals. 6.3.2 Uninsulated live parts are secured to its supporting surface so that they are prevented from turning or shifting in position. 7 CONNECTIONS 7.1 Field connections general requirements CB/ DE1-55514

age 135 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict 7.1.1 The module is provided with wiring terminals, connectors, or leads to accommodate currentcarrying conductors of the load circuit. 7.1.2 Field connections are rated for exposure to direct sunlight as defined in Clause 5 of IEC 61730-1. Field connections are exposed to the degrading effects of direct sunlight. Lead is connected to the connector directly. Connector is separately approved by TUV Rheinland (R 50175587) based on EN 50521:2008 and by UL based on UL Subject 6703 (E341975) Lead is connected to the connector directly. Connector is separately approved by TUV Rheinland (R 50175587) based on EN 50521:2008 and by UL based on UL Subject 6703 (E341975) Lead is connected to the connector directly. Connector is separately approved by TUV Rheinland (R 50175587) based on EN 50521:2008 and by UL based on UL Subject 6703 (E341975) 7.2 Field wiring terminals 7.2.1 Field wiring terminal blocks are rated for the appropriate voltage and current for the application and constructed in compliance with IEC 60947-1. 7.2.2 Wiring terminals integral to the construction of the terminal enclosure comply with the following requirements: 7.2.2.1 a) Screws and nuts which clamp external conductors have a thread conforming with ISO 261 or ISO 262 (or comparable standards) The screws and nuts used for field wiring do not serve to fix any other component. 7.2.2.2 b) Terminal screws have a minimum nominal thread diameter as shown in Table 2 of IEC 61730-1. Stud terminals are provided with nuts and washers. 7.2.2.3 c) Terminals are designed that they clamp the conductor between metal surfaces with sufficient contact pressure and without damage to the conductor. Terminals are designed or located that the conductor cannot slip out when the clamping screws or nuts are tightened. Terminals are fixed suitably when the means of clamping the conductor is tightened or loosened: The terminal itself does not work loose, Internal wiring is not subjected to stress, CB/ DE1-55514

age 136 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict Creepage distances and clearances are not reduced below the values specified in clause 9 of IEC 61730-1. 7.3 Connectors 7.3.1 The connector intended for use in the output circuit of the module is rated for the appropriate voltage and current, as per the requirements of the IEC 60130 series. Connectors comply with the requirements of Clause 5 of IEC 61730-1, with respect to flammability, comparative tracking index and relative thermal index for the support of live parts. 7.3.2 The connector has been appropriately evaluated for disconnect overload performance. 7.3.3 Connectors intended for exposure to the outdoor environment are enclosed by material which complies with the following: e) UV resistance in accordance with the requirements of Clause 5. f) Resistance to inclusion of water acc. to IEC 60529 (equivalent to I55) Lead is connected to the connector directly. Connector is separately approved by TUV Rheinland (R 50175587) based on EN 50521:2008 and by UL based on UL Subject 6703 (E341975) The RTI of junction box is approved by UL. (E82268, 644(f1)(c)) No I 67 g) Steel ball impact test acc. to IEC 61721 h) Accessibility Test MST 11 of IEC 61730-2 Verified with test MST 11 of 61730-2 7.3.4 Separable multi-pole connectors are polarized. 1 connector is male type. 1 is female type. Improper connection is not possible If two or more separable connectors are provided, they are configured or arranged so that the other will not accept the mating connector for one. 7.3.5 For a connector incorporating a grounding member, the grounding member is the first to make and the last to break contact with the mating connector. 7.3.6 Connectors that can be separated without the use of a tool do not have accessible conductive parts, as determined under the Accessibility Test MST 11 of IEC 61730-2. No grounding member in the connector No accessible conductive part Verified with test MST 11 of 61730-2 7.4 Output lead or cables CB/ DE1-55514

age 137 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict Leads extending from the module are rated for the appropriate system voltage, ampacity, wet locations, temperature and sunlight resistance.. System voltage: 600 V (UL), 1000 V (TUV). Ampacity: 12 AWQ, 4,0. Wet location: WET or DRY. Temperature: -40-90. Sunlight resistance : SUN RES 8 BONDING AND GROUNDING 8.1 If accessible conductive parts of the module form a perimeter framing or mounting system, or if the module has a conductive surface area of greater that 10 cm² accessible after installation, then the module has provisions for grounding. 8.2 If the module is rated as safety class II and provided with provisions for functional grounding, the functional grounding is isolated from live parts by reinforced insulation (Sub clause 7.3.2.2 of IEC 61140). 8.3 Each exposed conductive part of the module, that is assessable during normal operation, is bonded together, as verified by Ground Continuity Test MST 13 of IEC 61730-2. Note: If conductive materials are used only as fasteners for installation and separated from the conductive components of the module by both appropriate insulation and spacings, they are not required to be bonded. 8.4 Routine maintenance of the module does not involve breaking or disturbing the bonding path. A bolt, screw, or other part used for bonding purposes is not intended for securing the complete device. 8.5 Bonding is by a positive means, such as clamping, riveting, bolted or screwed connections, or welding, soldering or brazing. The bonding connection penetrates all nonconductive coatings, such as paint, anodized coatings or vitreous enamel. 8.6 All joints in the bonding path are mechanically secure. 8.7 If the bonding connection depends upon screw threads, two or more screws or two full threads of a single screw engage the metal. Grounding position and the way to grounding are stated in the installation instruction. Verified by 10.3 of IEC 61215 Verified by MST 13 of IEC 61730-2 Bonding position is not broken or disturbed during the routine maintenance. There are installation holes except for ground hole. Bolted connection or Clamping connection (Verified by MST 13 of 6173002) The washer s pin is screwed in side of coatings. Mechanically secure, without soldering. CB/ DE1-55514

age 138 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict 8.8 The diameter of the grounding screw or bolt is sized appropriately to the gauge of the bonding conductor, as per Table 2 of IEC 61730-1. 8.9 Ferrous metal parts in the grounding path are protected against corrosion by metallic or nonmetallic coatings. 8.10 The module has metal-to-metal multiple-bearing pin-type hinges. These are considered to be an acceptable means for bonding. 8.11 A wiring terminal or bonding location is identified with the appropriate symbol (IEC 60417-5019) or has a green-colored part. No other terminal or location is identified in this manner. 8.12 If a marking is used to identify an equipment grounding terminal, it is located on or adjacent to the terminal, or on a wiring diagram affixed to the module or panel near the terminal. See the construction details No ferrous metal parts contained Multiple-bearing pin-type hinge not present Identified Grounding mark is attached near the grounding point. 9 Creepage and Clearance distances 9.1 Creepage and clearance distances between uninsulated live parts not of the same potential and between a live part and an accessible metal part, are not less than the values specified in Tables 3 and 4 of IEC 61730-1. Class A, Max. system voltage: 1000 V Minimum measured creepage and clearance distances between field wiring terminals (mm)... : Minimum Measured clearance distances between internal current carrying parts and accessible points (mm)... : 9.2 Creepage and clearance distances at field wiring terminals have been judged on module open-circuit voltage (V oc ). If additional unmarked terminals exist in the terminal block, or if wiring terminals are marked specifically for grounding, the creepage and clearance distances have been judged on the basis of the maximum system operating voltage. 9.3 The spacings at a field-wiring terminal have been measured with and without wire connected to the terminal. If the terminal will properly accommodate it, and if the product was not marked to restrict its use, the wire is one size larger than that required, otherwise, the wire is of the required size.. Cell to edge : >8,4 mm. Ribbon to edge : >8,4 mm. The frameless module was used. No such terminals CB/ DE1-55514

age 139 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict 9.4 Surfaces separated by a gap of 0,4 mm or less have been considered to be in contact with each other. Considered 10 FIELD WIRING COMARTMENTS WITH COVERS 10.1 General If the module is designed for the application of a permanently attached wiring system by an installer in the field, it is to be provided with an enclosed wiring compartment 10.2 Wall thickness If the wiring compartment is intended for the attachment of a field-applied permanent wiring system, the minimum wall thickness for the material complies with Table 5 of IEC 61730-1. 10.3 Internal volume The internal volume for each intended conductor complies with the requirements of Table 6 of IEC 61730-1. In the space comprising the minimum required volume, no enclosure dimension is less than 20 mm. 10.4 Openings All openings are provided with appropriate coverings, whose functions comply with the requirements of: Sub clause 5.2.1 of IEC 61730-1 Wet leakage Current test of Sub clause 10.20 of IEC 61646 or 10.17 of IEC 61215 Ed. 2. Accessibility test MST 11 of IEC 61730-2 Coverings can only be removed by the use of a tool 10.5 Gaskets and seals Gaskets and seals do not deteriorate beyond limits during accelerated ageing, and are not used where they may be subject to flexing during normal operation. 10.6 Strain relief CB/ DE1-55514

age 140 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict Any strain relief is provided so that stress on a lead intended for field connection, or otherwise likely to be handled in the field, including a flexible cord, is not transmitted to the electrical connection inside the module. Note: Mechanical securement means which comply with Sub clause 10.14 (Robustness of Terminations Test) of IEC 61215 meet this requirement. 10.7 Sharp edges 10.7.1 The enclosure is smooth and free from sharp edges, burrs, or the like that may damage insulation or conductors. 10.7.2 The inner edges of conduit openings and knockouts are smooth and free from sharp edges, burrs, or the like that may damage insulation or conductors. 10.8 Conduit applications Metallic 10.8.1 Any threaded hole in a metal wiring compartment intended for the connection of rigid metal conduit is reinforced to provide metal not less than 6,4 mm thick. Any threaded hole is tapered unless a conduit end stop is provided. 10.8.2 If threads for the connection of conduit are tapped all the way through a hole in a compartment wall, there are not less than 3.5 nor more than 5 threads in the metal and the construction was such that a conduit bushing can be attached as intended. The construction is such that a conduit bushing can be attached as intended. 10.8.3 If threads for the connection of conduit are not tapped all the way through a hole in a compartment wall, there are not less than 5 full threads in the metal and there was a smooth, rounded inlet hole for the conductors. There are smooth, rounded inlet holes for the conductors. 10.8.4 For a non-threaded opening in a metal wiring compartment intended to accommodate rigid metallic conduit, a flat surface of sufficient area is provided around the opening to accept the bearing surfaces of the bushing and lock washer. 10.8.5 Conduit complies with the Conduit bending test MST 33 of IEC 61730-2. 10.9 Conduit applications Non-metallic 10.9.1 The thickness of sides, end walls, and bottom of a non-metallic wiring enclosure specified for conduit applications is not less than the values specified in Table 7 of IEC 61730-1. See Annex 2 for technical details CB/ DE1-55514

age 141 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict 10.9.2 A non-metallic wiring compartment intended to accommodate non-metallic conduit fulfils the following requirements: a) It has one or more unthreaded conduitconnection sockets; b) It has one or more threaded or unthreaded openings for a conduit-connection socket, or one or more knockouts that comply with the requirements of Knockout Test MST 44 of IEC 61730-2; c) It complies with the Conduit Bending Test MST 33 of IEC 61730-2, if intended for rigid non-metallic conduit. 10.9.3 Sockets for the connection of non-metallic conduit provide a positive end stop for the conduit. The socket diameters, the throat diameter at the entrance to the box, the socket depths, and the wall thickness of the socket are within the limits specified in the applicable conduit system. 10.9.4 A knockout or opening in a non-metallic wiring compartment intended to accommodate rigid nonmetallic conduit complies with the dimensional requirements of the applicable conduit system. 11 MARKING 11.1 The module includes the following clear and indelible markings: Name, monogram or symbol of manufacturer Type or model number LG300N1K-G4 Serial number Yes olarity of terminals or leads + and - mark on connectors Maximum system voltage 1000 V Safety class (IEC 61140) Symbol The date and place of manufacture are marked on the module or are traceable from the serial number. International symbols are used where applicable. 11.2 The following additional markings are applied to either the module or placed into the instruction and installation data (required documents). Traceable by non-recurring serial number/ date on label Voltage at open-circuit On label Current at short-circuit On label CB/ DE1-55514

age 142 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict Maximum over-current protection rating, as verified by the Reverse Current Overload Test MST 26 of IEC 61730-2 Recommended maximum series/parallel module configurations On label / in manual In manual Application class On label / in manual All electrical data are given relative to Standard Test Conditions (1000W/m 2 @ 25 C) 11.3 Connectors suitable only for field assembly of modules are marked Do not disconnect under load. 11.4 For modules with open-circuit voltage in excess of 50 V, and/or modules rated for maximum system voltage in excess of 50 V, a highly visible warning label regarding the shock hazard is applied near the means of connection to the module. On label / in manual On connectors, additionally marked on label 12 REQUIREMENTS FOR SULIED DOCUMENTS 12.1 The module or panel is supplied with installation instructions describing the methods of electrical and mechanical installation and the electrical ratings of the module. The instructions state the application class under which the module was qualified and any specific limitations required for that application class. 12.2 When the fire rating is dependent on a specific mounting structure, specific spacing, or specific means of attachment to the roof or structure, details of the specific parameter or parameters are included in the instructions. 12.3 The electrical installation instructions include a detailed description of the wiring method. The description of the wiring method includes the following information: Electrical rating given in Datasheet, installation is described in an extra manual Grounding method Size, type, and temperature rating of the conductors 4 mm 2 V-cable, applicable for 90 minimum Recommended maximum series/parallel module configurations Type of over-current protection and diode bypassing to be used Minimum cable diameters when the wiring method is cable Any limitations on wiring methods that apply to the wiring compartment or box 20/1 20 A 4 mm 2 CB/ DE1-55514

age 143 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-1 Clause Requirement Test Result Remark Verdict 12.4 The mechanical installation instructions for roof mounting include: A statement indicating the minimum mechanical means for securing the module or panel to the roof A statement that the assembly is to be mounted over a fire resistant roof covering rated for the application (only for non-integral modules or panels) Indication of any slope required for maintaining a fire class rating 12.5 The installation instructions include a statement advising that artificially concentrated sunlight shall not be directed on the module or panel. 12.6 Assembly instructions are provided with a product shipped in subassemblies, and are detailed and adequate to the degree required to facilitate total assembly of the product. 12.7 The installation instructions include the proposed statement given in this Sub clause (or equivalent) to allow for increased output of the module resulting from certain conditions of use. In manual CB/ DE1-55514

age 144 of 186 Test Report Ref. No.: VDE 208039-ET2-1 ATTACHMENT TO TEST REORT IEC 61730-1A EUROEAN GROU DIFFERENCES AND NATIONAL DIFFERENCES (hotovoltaic (V) module safety qualification - art 1: Requirements for construction) Differences according to...: EN 61730-1: 2007 Attachment Form No....: EU_GD_IEC61730-1A Attachment Originator... : TÜV SÜD roduct Service GmbH Master Attachment...: 2011-07 Copyright 2011 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. Clause Requirement + Test Result - Remark Verdict General Replace all references to this part of IEC 61730 and IEC 61730-2 by this part of EN 61730 and EN 61730-2 Considered 3.2 CLASS A: GENERAL ACCESS, HAZARDOUS VOLTAGE, HAZARDOUS OWER ALICATIONS Replace the text by: Considered Modules rated for use in this application class may be used in systems operating at greater than 120 V DC. Modules qualified for safety through this part of EN 61730 and EN 61730-2 within this application class are considered to meet the requirements for safety class II. Voltage (V) : Considered 3.4 CLASS C: LIMITED VOLTAGE Replace the text by: Considered Modules rated for use in this application class are restricted to systems operating at less than 120 V DC. Modules qualified for safety through this part of EN 61730 and EN 61730-2 within this application class are considered to meet the requirements for safety class Ill. Voltage (V) : Considered Note: Safety class are defined within EN 61140 Considered 5.1 GENERAL Replace the second paragraph by: Exception: Encapsulation materials (such as EVA, V, TU etc.) are not required to meet these requirements. Considered 5.2 olymers serving as an enclosure for live parts In item c), replace ANSI/UL 746C by EN ISO 4892 series. Considered CB/ DE1-55514

age 145 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Clause Requirement + Test Result - Remark Verdict 5.3 olymers serving to support live parts In item b), replace 250 V by 250. Considered Add the following notes: Considered Note 1: olymeric materials having a CTI of 250 or more fall within insulation class IIIa of EN 60664-1. Note 2: The use of polymeric materials requires consideration of the system voltage rating and pollution class. In this context Table 4 of EN 60664-1 shall be referenced. Delete item c). Considered In item d), replace ANSI/UL 746C by EN ISO Considered 4892 series. Renumber the note into note 3. Considered 5.4 olymers serving as an outer surface 5.4.3 Replace ANSI/UL 746C by EN ISO 4892 series. Considered 7.3 Connectors Add the following sentence: Considered The standardization of connectors for V application is an ongoing activity in CENELEC. This sub clause will be superseded by a future European Standard. 7.3.1 Replace IEC 60130 series by IEC 61984. Considered 7.3.3 Replace IEC 61721 series by IEC 60512-5-1 and EN 60512-5-2. Considered 11 MARKING Considered Add the following sentence: Considered The marking should be done in conformance with EN 50380. 11.1 Add to the list: Considered Application class of the product Considered For class A modules, the Safety Class II symbol (see IEC 60417, symbol 5172). Considered CB/ DE1-55514

age 146 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Test Report issued under the responsibility of: TEST REORT IEC 61730-2 V Module Safety Qualification art 2: Requirements for testing Test Report Reference No.... : 208039-ET2-1 revious report no.: 208040-ET2-1 dated 2015/04/16 Date of issue (YYYY/MM/DD)... : 2015/04/22 Total number of pages... : CB/CCA Testing Laboratory... : Address... : Applicant s name... : Address... : 186 (82 pages of this report/ part of CB report) VDE rüf- und Zertifizierungsinstitut GmbH VDE Testing and Certification Institute Merianstrasse 28, D-63069 Offenbach, Germany LG Electronics Inc. 168, Suchul-daero, Gumi-si, Gyeongsangbuk-do, 730-903, Rep. of Korea Test specification: Standard... : IEC 61730-2 Ed. 1, modified + A1 2011 Test procedure... : Non-standard test method..: Test Report Form No.... : TRF Originator... : CB- Scheme IEC61730_2A TÜV Rheinland roduct Safety GmbH Master TRF... : Dated 2007-11, VDE modified 2014-09 Copyright 2007 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-iecee members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. Test item description... : hotovoltaic (V) Module(s) Trade Mark... : Model/Type reference... : Manufacturer... : LGxxxN1K-G4 (xxx 280~330, 5steps) LG Electronics Inc. Ratings... : See page 4 CB/ DE1-55514

age 147 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Testing procedure and testing location: CB/CCA Testing Laboratory: Testing location/ address... : Associated CB Laboratory: Testing location/ address... : Tested by (name + signature)... : Approved by (name + signature). : Testing procedure: CTF stage 1 Tested by (name + signature)... : Approved by (name + signature)... : Testing location/ address... VDE rüf- und Zertifizierungsinstitut GmbH VDE Testing and Certification Institute Section ET2 Merianstrasse 28, D-63069 Offenbach, Germany (Authorization of test report) (Authorization of test report) Testing procedure: CTF stage 2 Tested by (name + signature)... : Kwang-sik Hyoung Witnessed by (name + signature).. : Approved by (name + signature)... : Roland Herbert (Authorization of test report) Jürgen Bärwinkel Testing location/ address...umyeon R&D Campus, 16, Umyeon-dong, Seocho-Gu, Seoul, Korea Testing procedure: SMT Tested by (name + signature)...: Approved by (name + signature)..: Supervised by (name + signature): Testing location/ address... : Testing procedure: RMT Tested by (name + signature)...: Approved by (name + signature)..: Supervised by (name + signature): Testing location/ address... : CB/ DE1-55514

age 148 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Summary of testing: Tests performed (name of test and test clause): Retest clause e) Backsheet(V-BS MGEW-SbR, V-BS MGEW-SbR) addition, Black string connector (Black 0.3-5.0, Sn-b, 40 μm) addition. Both backsheets have identical chemical, electrical and physical properties. Due to engineering decision only the V-BS MGEW- SbR backsheet was tested. The testing on the black patterned back sheet BS V-BS MGEW-SbR was omitted since it was considered less critical all black version. Testing location: See page 1 Summary of compliance with National Differences: See appended Report EUROEAN GROU DIFFERENCES AND NATIONAL DIFFERENCES to IEC 61730-2. Copy of marking plate: CB/ DE1-55514

age 149 of 186 Test Report Ref. No.: VDE 208039-ET2-1 Test item particulars... : Accessories and detachable parts included in the evaluation... Mounting system used... : Continuous bar mounting Other options included... :... : ossible test case verdicts: - test case does not apply to the test object... : - test object does meet the requirement... : (ass) - test object does not meet the requirement... : F (Fail) Abbreviations used in the report: CTI Comparative Tracking Index FF Fill factor Ipm Maximum power current Isc Short circuit current MST Module Safety Test max Maximum power D artial Discharge RTI Relative Thermal Index STC Standard Test Conditions TC Thermal Cycling Voc Open circuit voltage Vpm Maximum power voltage Testing Date of receipt of test item... : 2015/01/27 Date (s) of performance of tests... : 2015/01/27 ~ 2015/03/23 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma (point) is used as the decimal separator. This Test Report Form is intended for the investigation of V module in accordance with IEC 61730-2. It can only be used together with IEC 61730-1 Test Report. List of test equipment must be kept on file and available for review. Factory (for information only) Name... : Address... : LG Electronics Inc. 168, Suchul-daero, Gumi-si, Gyeongsangbuk-do, 730-903, Rep. of Korea CB/ DE1-55514

age 150 of 186 Test Report Ref. No.: VDE 208039-ET2-1 General product information: V module type reference... : LGxxxN1K-G4 roduct Electrical Ratings at STC Nominal maximum power (max)...: 300 W Nominal short circuit current at (Isc)...: 9,70 A Nominal open circuit voltage at (Voc)...: 39,7 V Nominal maximum power current (Ipm)...: 9,26 A Nominal maximum power voltage (Vpm)...: 32,5 V roduct Safety Ratings Maximum system voltage...: 1000 V Maximum over-current protection rating...: 20 A Safety application class...: A Safety class in accordance with IEC 61140...: II Fire safety class...: C Recommended maximum series/parallel module configurations...: 20/1 Scope of Module Safety Qualification Testing Initial Module Safety Qualification Extension of Module Safety Qualification Original Test Report Ref. No : 208039-ET2-1 Change in cell technology Modification to encapsulation system Modification to superstrate Increase in module size Modification to frame and/or mounting structure Modification to junction box/el. termination Change in cell interconnect materials/technique Change in el. circuit of an identical package Modification to backsheet/substrate Higher or lower output by 10% Note (1) Use the General product information field to give any information on model differences within a product type family covered by the test report. Note (2) Use the General product information field to describe the range of electrical and safety ratings, if the TRF covers a type family of modules. Note (3) Use Annex 1 to list the used materials and components of the module (manufacturer/supplier and type reference) CB/ DE1-55514

age 151 of 186 Test Report Ref. No.: VDE 208039-ET2-1 TEST SEQUENCES FOR MODULE SAFETY TESTING UNDER IEC 61730-2 CB/ DE1-55514

age 152 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict 3 ALICATION CLASSES The module has been evaluated for the following Application Class (Class A, B, C)... : Class A REQUIRED TESTS DEENDING ON THE ALICATION CLASS Application Class A B C * * - - - - - Module Safety Test reconditioning tests: MST 51 Thermal cycling (TC50 or TC200) MST 52 Humidity freeze MST 53 Damp heat MST 54 UV resistance General inspection test: MST 01 Visual Inspection Electrical shock hazard tests: MST 11 Accessibility test MST 12 Cut Susceptibility test MST 13 Ground Continuity test MST 14 Impulse Voltage test MST 16 Dielectric Withstand test MST 17 Wet Leakage Current test MST 42 Robustness of terminations ** - - - - - - - Fire Hazard tests: MST 21 Temperature test MST 22 Hot spot test MST 23 Fire test MST 26 Reverse current overload test Mechanical stress tests: MST 32 Module breakage test MST 34 Mechanical load test Component tests: MST 15 artial discharge test MST 33 Conduit bending MST 44 Terminal box knockout test Legend: Test required - Test not required * Different test levels for Application class A and B ** Minimum Fire Resistance Class C is necessary for building roof-mounted modules. CB/ DE1-55514

age 153 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict 6 SAMLING The modules tested (modules and laminate) were taken at random from a production batch and subjected to manufacturer s normal quality control and inspection for safety testing The modules tested (modules and laminate) were prototypes of a new design and not taken from a production batch. reconditioning of test samples was performed within IEC 61215 or IEC 61646 performance testing reconditioning of test samples was performed separately from IEC 61215 or IEC 61646 performance testing List of test samples Sample No. Type/model Remark 1 LG300N1K-G4 C1501062 (Control) 3 LG300N1K-G4 C1501076 (MST12, MST42, MST51b, MST52, MST54) 7-1 LG300N1K-G4 C1501059 (MST12, MST34, MST53) 7-2 LG300N1K-G4 C1501060 (MST34, MST53) 9 LG300N1K-G4 C1501078 (MST14) 11 LG300N1K-G4 C1501079 (MST21) 12-1 LG300N1K-G4 C1501058 (MST23) 12-2 LG300N1K-G4 C1501080 (MST23) CB/ DE1-55514

age 154 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict 9 ASS CRITERIA The module under evaluation was judged to have passed all safety qualification test. The test samples met all of the criteria of each individual safety test. See appended Tables 10 TEST ROCEDURES Safety qualification testing included the following Module Safety Tests (MST) of IEC 61730-2: 10.1 MST 01 Visual inspection... : See appended Table 10.1 10.2 MST 11 Accessibility test... : See appended Table 10.2 10.3 MST 12 Cut susceptibility test... : See appended Table 10.3 10.4 MST 13 Ground continuity test... : See appended Table 10.4 10.5 MST 14 Impulse voltage test See appended Table 10.5 10.6 MST 16 Dielectric withstand test... : See appended Table 10.6 10.7 MST 21 Temperature test... : See appended Table 10.7 10.8 MST 23 Fire test... : See appended Table 10.8 10.9 MST 26 Reverse current overload Test... : See appended Table 10.9 10.10 MST 32 Module breakage test... : See appended Table 10.10 Component Tests 11.1 MST 15 artial discharge test... : Approved by TUV Rheinland 11.2 MST 33 Conduit bending test... : - 11.3 MST 44 Terminal box knockout test... : - CB/ DE1-55514

1 3 7-1 7-2 11 9 12-1 12-2 age 155 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Overview of MST items for each test sample MST item Sample No. Control module MST 01 Visual inspection MST 11 Accessibility test MST 12 Cut susceptibility test MST 13 Ground continuity test MST 14 Impulse voltage test MST 15 artial discharge test MST 16 Dielectric withstand test MST 17 Wet leakage current test MST 21 Temperature test MST 22 Hot-spot test MST 23 Fire test MST 25 MST 26 MST 32 MST 33 Bypass diode thermal test Reverse current overload test Module breakage test Conduit bending test MST 34 Mechanical load test MST 42 Robustness of terminations MST 44 Terminal box knock out test MST 51b Thermal cycling test (TC50) MST 51a Thermal cycling test (TC200) MST 52 Humidity freeze test MST 53 Damp heat test MST 54 UV preconditioning test Legend: n Test performed, where n gives the sequence of testing (n =1, 2 etc.) CB/ DE1-55514

age 156 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Table 10.1 MST 01 VISUAL INSECTION Sample No. osition in test sequence: 3 Initial examination No findings reconditioning: MST 54, MST 51b, MST 52, MST 42 MST 12, Cut susceptibility test Final examination No findings 7-1 Initial examination No findings reconditioning: MST 53, MST 34 MST 12, Cut susceptibility test Final examination No findings 7-2 Initial examination No findings reconditioning: MST 53, MST 34 Final examination No findings 9 Initial examination No findings MST 14, Impulse voltage test Final examination No findings 11 Initial examination No findings MST 21, Temperature test Final examination No findings CB/ DE1-55514

age 157 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Table 10.3 MST 12 CUT SUSCETIBILITY TEST Applied force (N)... : 8,9 Sample No. 3 No visual evidence that the superstrate or substrate have been cut No exposure of active circuitry of the module Requirement of MST 13, MST 16, MST 17 are met (see appended Tables 10.4, 10.6, MST17) 7-1 No visual evidence that the superstrate or substrate have been cut No exposure of active circuitry of the module Requirement of MST 13, MST 16, MST 17 are met (see appended Tables 10.4, 10.6, MST17) Table 10.5 MST 14 IMULSE VOLTAGE TEST Sample No. Maximum system voltage (V)... : 1000 Impulse voltage (V)... : 8000 Thickness of conductive foil (mm)... : 0,07 (with glue) 9 No evidence of dielectric breakdown or surface tracking observed No evidence of major visual defects (See appended table 10.1) CB/ DE1-55514

age 158 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Table 10.6 MST 16 DIELECTRIC WITHSTAND TEST Maximum system voltage (V d.c.)... : 1000 Test voltage applied (V d.c.)... : 1000 / 6000 Minimum allowable insulation resistance (MΩ)... : 25 Sample No. osition in test sequence: Dielectric breakdown Insulation resistance (MΩ) 3 Initial test... : >999 MST 54, MST 51b, MST 52, MST42 reconditioning Intermediate test... : >999 MST 12, Cut susceptibility test MST Final test... : >999 7-1 Initial test >999 MST 53, MST 34 reconditioning Intermediate test >999 MST 12, Cut susceptibility test MST Final test >999 7-2 Initial test >999 MST 53, MST 34 reconditioning Final test >999 9 Initial test >999 MST 14, Impulse voltage test MST Final test >999 11 Initial test >999 MST 21 MST Final test >999 CB/ DE1-55514

age 159 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Table 10.7 MST 21 TEMERATURE TEST Measuring location: Sample No.... : 11 Reference solar irradiance (W/m²)... : 1000 W/m² Reference ambient temperature ( C)... : 40 (Open 23,4 / Short 23,8) Mounting platform surface underneath centre cell Module open-circuited Component temperature T OBS ( C) Normalized temperature T CON ( C) Component temperature limit ( C) 44,6 61,2 90 Substrate backsheet behind area of centre cell 72,1 88,7 110 Module output leads 40,4 57,0 90 J-box inside surface(base) 44,4 61,0 90 Field wiring connection or connector 38,6 55,2 90 Backsheet beneath J-box 64,3 80,9 110 ositive terminal block 50,2 66,8 90 ositive wiring lead inside junction box 52,8 69,4 90 Frame 52,2 68,8 90 Mounting platform surface (wood) 48,3 64,9 90 Diode #1 case 53,9 70,5 188 Diode #2 case 55,0 71,6 188 Diode #3 case 55,9 72,5 188 Superstrate glass surface 68,1 84,7, Glass Mounting platform surface underneath centre cell Measuring location: Mounting platform surface underneath centre cell Module short-circuited 44,6 61,2 90 Component temperature T OBS ( C) Normalized temperature T CON ( C) Component temperature limit ( C) 44,5 60,7 90 Substrate backsheet behind area of centre cell 69,4 85,6 110 Module output leads 39,6 55,8 90 J-box inside surface(base) 42,6 58,8 90 Field wiring connection or connector 37,6 53,8 90 Backsheet beneath J-box 60,0 76,2 110 ositive terminal block 48,0 64,2 90 ositive wiring lead inside junction box 50,9 67,1 90 Frame 50,6 66,8 90 CB/ DE1-55514

age 160 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Mounting platform surface (wood) 48,7 64,9 90 Diode #1 case 51,6 67,8 188 Diode #2 case 52,6 68,8 188 Diode #3 case 53,9 70,1 188 Superstrate glass surface 63,8 80,0, Glass T CON = T OBS + (40 C T AMB ) Temperature limits are given in Table 9 of IEC 61730-2. CB/ DE1-55514

age 161 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict Table 10.8 MST 23 FIRE TEST Module fire resistance class (A, B, C)... : Class C No. of modules provided to create the test assembly... : 2 Sample No. 12-1, 12-2 The module complies with the requirements for the fire resistance class Condition: Wind speed (5, 25 ~ 5, 37 m/s), Temp. (718,5 ), Heat supply (18023 BTU/min) Spread of fire (Sample #12-1): Glass crack (4:12), Backsheet delamination. (3:14), Flame distinguishing (4:10) No flame drop or spread after firing (ass) CB/ DE1-55514

age 162 of 186 Test Report Ref. No.: VDE 208039-ET2-1 IEC 61730-2 Clause Requirement Test Result Remark Verdict. Burning brands test(sample #12-2): Burning temperature (888,5 C) No flame drop or spread after firing (ass) CB/ DE1-55514