FC724 Fire control panel

Similar documents
FC722 Fire control panel

FC724 Fire control panel

FC723 Fire control panel

FC722 Fire control panel

FC2020 Fire control panel

FC2040. Fire control panel. Sinteso. FS20 series, MP6

Fire control panels FC726 FC726-XA

Fire control panel for modernization

Fire control panels FC360

FS20 Fire detection system

Sinteso TM product catalog.

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FDCL221-M Multi line separator module

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

FDCIO223 (ES 45) Transponder

FT2080 Fire terminal (Touch) Mounting Installation

FS720 Fire detection system Planning

FT2080 Fire terminal (Touch) Mounting Installation

Input module, input/output modules

Multi line separator module

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

Input module, input/output module

FDCL221-Ex Line adapter (Ex)

Fire safety products and accessories siemens.com/cerberus

OOH740, OOHC740 Automatic fire detectors

Synova TM product catalog.

OOH740-A9-Ex Multi-sensor fire detector

FS720 Fire detection system (marine) Technical Manual

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

Output module (230 V)

OOH740-A9-Ex Multisensor fire detector

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

XC10 Extinguishing control panels

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

DC1192 Input /Output module

FC700A Fire detection control unit

Mimic display driver, LED ribbon cable

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

DF1101-Ex Infrared flame detector

Answers for infrastructure. Cerberus PRO enjoy protecting

Cerberus FIT conventional system

ASA linear smoke detector

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

OH720, OP720, HI720, HI722

FDCW241 Radio gateway Mounting

FDBZ290 Air sampling smoke detection kit

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

Cerberus PRO A comprehensive fire-protection system

Cerberus PRO enjoy protecting A comprehensive fire protection system

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

FDBZ290 Air sampling smoke detection kit

FDOOT241-A9-Ex Multisensor fire detector

XC10 combined fire detection and extinguishing control

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

FDCL221 Line separator

Fire control panel detect 3004 plus and accessories

FP120-Z1 Power supply kit A (70 W) Technical Manual

FDCI221, FDCIO221 Input module, input/output module Technical Manual

FDOOT241-9, FDOOT241-A, FDO241, FDT241

Desigo TM Fire Safety System A comprehensive fire-protection system

ARCHITECT AND ENGINEER SPECIFICATIONS

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

XC10 combined fire detection and extinguishing control

FC721 Fire control panel Technical Manual

Call stations and extensions

Desigo TM Fire Safety System A comprehensive fire-protection system

FDA241, FDA221 Siemens ASD

Building Technologies. FDUL221 en Line tester operating instructions for electricians

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

Interbases. Sinteso FDSB221, FDSB228, FDSB229

SWING radio fire detection system

Desigo Fire Safety Marine Fire and Detection Equipment Models FH-2071-UM, BP-62 and USCG-HPLATE

FDOOT221, FDO221, FDT221

Cerberus ECO. Fire Safety Products and Accessories. Product Catalogue. siemens.com/buildingtechnologies

Fire Detection Systems Product Catalogue (Version )

FDA241, FDA221 Siemens ASD

DF1151-Ex Infrared flame detector

On the job around the clock 24/7: Fire detection systems

DM1131 / DM1133 / DM1134 Manual call points

FC121-ZA / FC122-ZA / FC123-ZA / FC124-ZA

Test units and accessories

Test units and accessories

Test units and accessories

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

Cerberus ECO enjoy protecting. Product Brouchure.

Inside a typical. Intelligent Voice Communication System. Mounting Diagram. 2 Cerberus PRO. 252 / 504-point Cerberus PRO fire / voice system

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Intelligent addressable fire alarm control panel

Radio fire detection system

CerberusTM. PRO intelligent protection. A comprehensive fire protection system. Answers for infrastructure.

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Solution F2. Fire Alarm Control Panels one step ahead.

MK8000 OPC Server Interface Specification for CS1115 Building Technologies

Planning Instructions MEW01776 Revision -

Transcription:

FC724 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as stand-alone version or networked Up to 64 stations (fire control panels and fire terminals) can be connected in one network Integrated emergency operation function Redundant network node, degrade operation according to EN 54 Fast Ethernet interface for heterogeneous network Integrated user-friendly operating unit Optional printer, key switch, LED indicators Slots for RS232, RS485 serial ports Emergency power supply for up to 72 h emergency power time Detection and automatic read-in (auto configuration) of all C-NET devices, providing immediate simple operation Processes signals from the Cerberus PRO FD720 detector series Floor repeater devices, alarm devices and mimic displays in the detector loop (C-NET) Flexible programming of complex applications and controls Stored data can be uploaded via remote access Firmware download of all processor controlled control panel components

avoid electrostatic charging! avoid electrostatic charging! System overview FC724 FT724 Repeater FN2002 Cluster (C-WEB/SAFEDLINK) FC724 Fire control panel Remote access Engineering Tool, Operating Tool DM0x DT0x-Ex Explosionhazard area DO0-Ex FT20 Floor repeater display 24VDC ext. possible HI722 FDCI222 FDS229 4 inputs DBS720 Detection line collective Siemens, TM Synova SynoLINE300 or SynoLINE600 SB3 FDM22x FDS22 or DBS72 / DBS729 OH720 output FDCIO22 input 24VDC ext. FDCIO223 2 in-/outputs optionally C-NET 4 (8) loops max. 504 addresses Mimic display FT200-A FDCI22 FDM22 HI720 FDCL22 OP720 OP720 OH720 stub line 4 outputs FT200 Floor repeater terminal input 4 inputs 24VDC ext. possible FDCIO222 Transmission of an alarm signal Transmission of a fault signal via FCI2007-A Conventional horn line via FCI2009-A Fire controls via FCI2008-A FC0 or XC0 Fire detection or Extinguishing control unit collective 2

Networking topologies Up to 32 fire control panels und fire control terminals can be connected in a single cluster (C-WEB/SAFEDLINK) or up to 6 stations when the cluster is connected to a danger management system. Using a fiber-optic Backbone (C-WEB/LAN) up to 4 of the above mentioned clusters (with up to 6 stations each) can be networked. The entire network may contain up to 64 stations. For details about system networking, please refer to product data sheet A6V0227649. 3

Characteristics The FC724 is a compact fire control panel with an integrated operating unit that can process signals from FD720 devices. The control panel can be used as a stand-alone unit or in a network. The control panel can be programmed with the user-friendly Cerberus-Engineering- Tool to create a system with great versatility. All detector lines are monitored for ground faults. Adaptation of the user text directly on the terminal or with the software engineering tool. Up to 2000 events can be stored according to various criteria. Automatic summer/winter time change. Connection of Siemens Danger Management System Functional elements Operating unit The following are located on the operating unit: CPU module and the electronics for the operating unit Ethernet connection Slots for RS232, RS485 modules and networking modules (SAFEDLINK) Space for 'Kaba' or 'Nordic' key switch Space for event printer Periphery board The following are located on the periphery board: Connection terminals for C-NET loops, remote transmission (alarm, fault), horn output, programmable control inputs/outputs, monitored alarm and fault output, degrade supply, power supply 2 plug-in position for loop extension (C-NET) Power supply 50 W, emergency power supply The power supply supplies the hardware and charges the batteries The batteries supply the emergency power in case of power failure Housing A pivoting mounting panel can be installed on the housing backplane to allow installation of: fire brigade periphery module (for Germany) sounder module (can also be mounted onto the U-rail TS35) Configuration The FXS722 Cerberus-Engineering-Tool permits the system to be adapted to specific customers' requirements. Application ranges The FC724 is ideally suited for medium-sized applications, e.g. in industrial plant, regional banks, office complexes, etc. or when networked as part of much larger applications. The FC724 can be used by the flexible cross-linking possibilities however also for extensive systems. Operation Each control panel has an integrated operating panel. Additionally the control unit can be operation for another separate FT724 operator terminal. For details and further information, please refer to product data sheet A6V0207898. 4

Overview of FC724 fire control panels Housing (Comfort) FC724-ZA FC724-ZE With 48 indicator groups with each one red + yellow LED 4 Loops 4 Loops With power supply (50 W) With power supply (50 W) Battery capacity max. 26 Ah Battery capacity max. 26 Ah Expansion External printer FH7202-Z3 FH7203-Z3 FTO200-A DL3750+ Housing (Standard) Housing (Comfort) Event printer Matrix printer (Extern) 430 x 398 x 60 mm 430 x 796 x 60 mm RS232 interface Empty housing for various applications Can be installed in all panels except RS232 module must be ordered separately RS232 module must be ordered separately e.g. for additional batteries, operating add-on or Operating add-on Event printer FCM72-Y3 Space for batteries 48 indicator groups 2 x FA2003-A (7 Ah) or with each one red + yellow LED 2 x FA2004-A (2 Ah) or 2 x FA2006-A (26 Ah) e.g. for additional batteries, operating add-on or Event printer For retrofitting Space for batteries 2 x FA2003-A (7 Ah) or 2 x FA2004-A (2 Ah) or 2 x FA2005-A (7 Ah) or 2 x FA2006-A (26 Ah) 5

Configuration of FC724 in housing (Comfort) 9 7 2 8 5 6 2 2 8 9 3 4 2 3 4 20 4 5 6 7 6 22 8 8 0 Basic equipment Designation Notes Rear (Comfort) FHA2003-A 2 Periphery board (4-Loop) FCI2004-A Pos. -5 > Basic equipment for each FC724-xx (Comfort) 3 Power supply (SV 24V-50 W) V24230-Z6-A4 4 Mains terminals on DIN mounting rail TS35 Space for socket, relay modules, etc. 5 Operating unit FCM72xx-xx Combined operating unit and CPU, incl. cover 6 Space for batteries 2 x 2 V / 7 26 Ah Expansion 7 Relay module Z3B7 Relay for fire controls 8 Event printer FTO200-A For event logging 9 Key switch (Kaba) FTO2005-C Key switch (Nordic) FTO2006-B For operating access rights 0 Mounting plate FHA2007-A E.g. for fire brigade peripheral Loop extension (FDnet/C-NET) FCI2003-A For loop extension of 2 to 4, number of addresses remains the same 2 RS485 module (isolated) FCA2002-A For peripheral devices with RS485 port 3 RS232 module (isolated) FCA200-A For stations with RS232 port 4 Networking module (SAFEDLINK) FN200-A For networking various stations 5 Repeater (SAFEDLINK) FN2002-A For the extension of the system bus C-WEB, max. between 2 stations (mounting direct onto plane surface, onto a U-rail TS35 or in housings FDCH22) 6 Sounder module FCA2005-A For split-up of to 4 conventional horn lines 6

Battery (2 V, 7 Ah, VDS) FA2003-A 7 Battery (2 V, 2 Ah, VDS) FA2004-A For emergency power supply Battery (2 V, 26 Ah, VDS) FA2006-A 8 Fire brigade periphery module FCI200-D For Germany (FBF, FSD, ÜE, FSE, ÖA, KL) 9 9" mounting kit FHA206-A For the installation in 3 rd party housings 20 License key L or FCA202-A For Cerberus-Remote License key (L2) FCA203-A For Management System (also includes Cerberus-Remote) 2 Cable kit (communication) FCA204-A For flexible cable connections to the modules on the operating unit 22 Power supply kit (50 W, B) FP2005-A For additional power supply Technical data Mains voltage Power supply Operating voltage Operating current Battery capacity Battery monitoring Mains monitoring Connectable detector series Number of lines Loops (with loop extension) or Stub lines AC 98 27 V / AC 96 253 V 50 W DC 2 28.6 V max. 5 A 2 x 2 V, 26 Ah yes yes Cerberus PRO FD720 (C-NET) 4 (8) 8 (6) Number of addresses max. 504 Integrated inputs/outputs Relay outputs RT alarm RT Fault Monitored outputs Alarm Fault Horn Free programmable inputs/outputs Operating unit 2 2 integrated Plug-in position for RS232, RS485 serial ports 2 Plug-in position for networking modules 2 Plug-in position for loop extension 2 Mounting place for cable kit (communication) 2 Sounder module max. 2 Ethernet connection RJ45 Operating temperature -8 +42 C Storage temperature -20 +60 C Humidity (no condensation permitted) 95 % rel. Dimensions (W x H x D) Without cover cap With cover cap Color Housing Cover Protection category (IEC 60529) Approvals VdS LPCB 430 x 796 x 60 mm 430 x 796 x 88 mm grey, ~RAL 7035 grey, ~RAL-Design 050 00 00 IP30 G209077 26aw/07 7

Details for ordering Type Part no Designation Weight Fire control panels FC724-ZA S54400-C30-A2 Fire control panel (4L) 8.280 kg FC724-ZE S54400-C30-A3 Fire control panel (4L, 2LED) 9.200 kg Expansion Z3B7 BPZ:484383000 Relay module 250 VAC / 0 A ( relay) 0.042 kg FTO200-A A5Q000026 Event printer 0.250 kg A5Q000769 Replacement printer rolls (0 rolls) 0.090 kg FTO2005-C A5Q00003 Key switch (Kaba) 0.03 kg FTO2006-B A5Q000029 Key switch (Nordic) 0.050 kg FHA2007-A A5Q00005 Mounting plate 0.800 kg FCI2003-A A5Q000036 Loop extension (FDnet/C-NET) 0.064 kg FCA2002-A A5Q00009923 RS485 module (isolated) 0.067 kg FCA200-A A5Q00005327 RS232 module (isolated) 0.068 kg FN200-A A5Q000285 Network module (SAFEDLINK) 0.077 kg FN2002-A S24236-B2502-A Repeater (SAFEDLINK) 0.54 kg FCA2005-A A5Q0004866 Sounder module 0.40 kg FCA204-A A5Q00023027 Cable kit (communication) 0.224 kg FCI200-D A5Q000300 Fire brigade periphery module 0.482 kg FH7202-Z3 S54400-B70-A0 Housing (Standard) 7.500 kg FH7203-Z3 S54400-B7-A0 Housing (Comfort) 5.000 kg FCM72-Y3 S54400-F75-A Operating add-on (2xLED-ind.) 2.600 kg FHA206-A A5Q0002079 9" mounting kit 3.000 kg FN2006-A S54400-A09-A Fiber network module (SM) 0.770 kg FN2007-A S54400-A0-A Fiber network module (MM) 0.770 kg Additional power FP2003-A A5Q0006005 Power supply kit (70 W) 0.650 kg supply FP2004-A A5Q00020825 Power supply kit (50 W) for installation in.366 kg empty housing FP2005-A A5Q0008779 Power supply kit (50 W, B) ) for cascading.00 kg Networks (backbone) FN2008-A S54400-F94-A Ethernet-Switch 0.800 kg FN2009-A S54400-F95-A Security module 0.800 kg FHA2029-A S54400-B79-A Mounting kit for Ethernet switch (Comfort) 0.500 kg FHA2030-A S54400-B8-A Mounting kit for Ethernet switch (Large Ext.) 0.500 kg Batteries FA2003-A A5Q0009353 Battery (2 V, 7 Ah, VDS) 2.450 kg FA2004-A A5Q0009354 Battery (2 V, 2 Ah, VDS) 3.930 kg FA2005-A A5Q0009677 Battery (2 V, 7 Ah, VDS) 5.640 kg FA2006-A A5Q0009356 Battery (2 V, 26 Ah, VDS) 7.572 kg Software license FCA202-A A5Q0008856 License key (L) 0.00 kg FCA203-A A5Q0008857 License key (L2) 0.00 kg External printer DL3750+ A5Q00023962 Matrix printer (Extern) 7.300 kg Spare part A5Q00023963 Black typewriter ribbon for matrix printer DL3750+ 0.078 kg Siemens Switzerland Ltd Infrastructure & Cities Sector Division International Headquarters Gubelstrasse 22 CH-630 Zug Tel. +4 4 724 24 24 www.siemens.com/buildingtechnologies 202 Copyright by Siemens Switzerland Ltd Data and design subject to change without notice. Supply subject to availability. Document no. A6V020776_d_en_-- Manual FS720 Edition 04.202 Section