WEAVE RADIANT TEXTILE PANEL. Credit Reimann Architecture

Similar documents
NEW AR-L AR-C AND HIGH-CAPACITY LINEAR COOLING PANELS. Higher energy efficiency. Increased thermal comfort

METALWORKS. Airtite Panels. Radiant Ceiling Systems

FDCLP2 Low Profile, Series Flow Fan Powered Terminal Unit

photo by PFC Price Fan Column

Operating Room Diffuser System with Integrated LED Lighting

EMBEDDED PIPE SYSTEMS. SURFACE HEATING AND COOLING Heat transfer coefficient COOLING CAPACITY. Max. heating-cooling-capacity

KLIMA Active Chilled Beams

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

WHAT - HOW - WHY - WHERE PROTERCEILING RADIANT CHILLED CEILINGS COMFORT - EFFICIENCY - SAVINGS - AESTHETICS

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

Kvadrat Soft Cells and Philips Large Luminous Surfaces

Active & Passive Beams

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active.

Radiant Ceiling. Metawell Klimadecke 1

VARICOOL Velum. System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

RoofPak Applied Rooftop Systems

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Centeral Station Air Handling Unit

Modular Active. Chilled. Beams

Chilled Beam and Radiant Cooling Basics. Salt Lake City, UT ASHRAE Chapter December 2013 Nick Searle

APPLICATION GUIDE BEAMS

Units for suspended ceilings Type DID632

Module 1: Introduction to Radiant Cooling. Pierre Jaboyedoff

Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Alumline Radiant Heating and Cooling Ceiling Panels

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

Ray Magic Quad Metal panels for suspended ceiling

CHILLED & HEATED CEILINGS

Active Chilled Beams

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

PRODUCTS TAO TAO PRODUCT: ADVANCING THE SCIENCE OF AIR DISTRIBUTION. temperature ambient optimizer. Redefine your comfort zone.

Halton CPT Passive Chilled Beam

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

SeasonMaker ThinLine Fan-coil Units

SECTION H. Engineering Guide Radiant Products. Please refer to the Price Engineer s HVAC Handbook for more information on Radiant Heating and Cooling

textile air dispersion products

Rittling Element. Catalog

Cabinet Unit Heaters Type CHF & CHB

IDL20e (2 way discharge) IDS60e (4 way discharge) Inffusers. UDI (vertical discharge) Frequently Asked Questions

Integrated Solution PARTNERS

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

SilverScreen. The innovation in solar heat and light control

Static cooling ceiling system SKS-4/3 DS 4094 E /1. Technical Selection

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

FLEX. Innovative lighting engineered for seamless integration into the DESIGNFlex ceiling system by

LOW STATIC HYDRONIC DUCTED UNIT

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

ACBH/ACBV ACTIVE CHILLED BEAM INSTALLATION MANUAL. Date: 05/12 Reference # : L-50.

INDOOR, SUSPENDED, STEAM OR HOT WATER HYDRONIC UNIT HEATER FOR VERTICAL OR HORIZONTAL CONFIGURATION

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Hydronic Heating Fan Coils Radiant ceiling systems Water Source Heat Pumps Rittling Econo-Line Enclosures

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

Trane Performance Climate Changer Air Handlers. An air handler for every need.

Easdale International INFINITY

The only lighting product that is designed, approved, and patented to replace the cross members in a suspended grid ceiling system.

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

Single Package Vertical Air Conditioners. Vert-I-Pak

lindab ventilation Lindab Comfort Waterborne indoor climate solutions Product overview

Cabinet Unit Heaters Steam / Hot Water

Trane Performance Climate Changer Air Handlers. An air handler for every need.

fire protection glass

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heating and Cooling Ceiling Systems Comfortable and energy efficient. Heating Cooling Fresh Air Clean Air

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

CHAPTER 4. HVAC DELIVERY SYSTEMS

Feel safe inside. Lets the fresh air in but that s all.

Feel safe inside. Lets the fresh air in but that s all.

Using high light reflectance acoustical ceilings to increase the energy efficiency of buildings

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Chilled Ceiling Elements

CAT-SIUH-2000(3) SUPERSEDES CAT-SIUH-98(2) SARAVEL INDUSTRIAL UNIT HEATERS

Ceiling air diffuser INDULTHERM INDULTHERM-e

Heating Installation Guide published by

Q-Tec TM QC-Series Chilled Water Air Conditioner

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

We are Kvadrat Brand breakdown

Vert-I-Pak Series. Single Package Vertical Air Conditioners. Installs easily in a closet for quiet operation THE EXPERTS IN ROOM AIR CONDITIONING

HYDRONIC COMPONENTS & SYSTEMS

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

Ceiling office High-performance Radiant Ceiling Systems

Küba SG commercial

SECTION AIR HANDLING UNIT

Krantz. Multifunction exposed ceiling AVACS. Cooling and heating systems

H Y D R O C O U R S E T R E N C H H E A T I N G

7. MECHANICAL SYSTEM DESIGN

Enriching Environments

High-Speed Roll Doors An intelligent entrance solution for every location. ASSA ABLOY Entrance Systems

DIVISION FURNISHINGS. WINDOW TREATMENTS Page 63 of WINDOW TREATMENTS WINDOW BLINDS

Open Cell / Cell Frame Ceiling Systems

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Radiant Heating & Cooling for Commercial Buildings

enviroblinds external blinds & shutters the secret to low carbon comfort

MECHANICAL SERVICES 101. Ian White

Transcription:

RADIANT TEXTILE PANEL Credit Reimann Architecture

Developed in conjunction with Kvadrat Soft Cells, Weave radiant textile panels by Price provide thermal and acoustic comfort as well as infinite design possibilities. Radiant panels function as part of a hydronic system to provide sensible heating and cooling for superior thermal comfort. Innovative textile technology allows the transmission of thermal radiation through the textile face to provide a unique aesthetic without compromising performance. Copper pipe coil Tensioning extrusion mechanism Heat transfer saddle Thermal and acoustic insulation Perforated aluminum radiant panel Thermally participative textile 2 For more information visit radiant@priceindustries.com v001

ENERGY EFFICIENT + + Radiant panel hydronic systems efficiently satisfy the sensible loads of a space while relying on a separate airside system to provide ventilation and satisfy latent loads. + + Hybrid air-hydronic systems require significantly lower supply air volumes than all-air systems, reducing fan power requirements by 60-80% and resulting in a smaller, more efficient system. SUPERIOR THERMAL COMFORT + + Radiant cooling and heating efficiently conditions a space while maintaining a high degree of thermal comfort. + + As a result of the reduced supply air volume requirements associated with hydronic-air systems, air velocities are kept low, minimizing draught risk and fan energy. + + For superior thermal comfort, radiant panels work to change the operative temperature of a space including both the air temperature and the surface temperatures within the space. All-air systems change only the air temperature, neglecting surface temperatures that are an important aspect in determining thermal comfort. TYPICAL APPLICATIONS Available in bespoke shapes and sizes, Weave radiant textile panels are upholstered in Kvadrat textiles to provide colour and texture options for seamless integration with any design scheme. Capable of both heating and cooling, Weave can be applied to most spaces, especially those with high sensible loads, high indoor air quality requirements, or where thermal comfort and energy conservation are major design considerations. Typical applications include office buildings, schools, public buildings and airports that have 50-75% of the ceiling area active with radiant panels. OPTIMAL HEAT TRANSFER + + Weave is made up of three layers: copper tubing, aluminum panels, and a textile panel face, all of which are kept in direct contact to optimize heat transfer between layers. + + The perforated aluminium panels incorporate a saddle to optimise energy exchange between the pipe and the panel. + + A non-hardening heat paste between the saddles and the copper tubes ensures efficient and even heat distribution to the textile panel face. + + The thermally activated textile panel face is held in contact with the aluminium panel using Soft Cells patented tensioning mechanism for optimal heat transfer. The quality of the contact will not diminish over time. v001 For more information visit radiant@priceindustries.com 3

AESTHETIC OPTIONS + + Weave is available with countless customization options including: + + Four textile colour options + + Maximum standard size of a single panel 1250 mm x 2470 mm + + Custom shape and size including flat curves + + Three mounting options: + + Torsion spring + + Hinged + + Weave can be refreshed to meet changing interior requirements as often as required. Quick to install, each panel can just as easily be demounted, reupholstered and reinstalled. + + Weave radiant textile panels can easily integrate with other ceiling fixtures including Price Node for integration of lighting and services. + + Optional end caps provide a finished look for applications with exposed edges. + + Wall 4 For more information visit radiant@priceindustries.com v001

Torsion spring Installation Hinged Ceiling Solution End Caps Wall Mounting and Custom Shapes Credit Ed Reeve v001 For more information visit radiant@priceindustries.com 5

QUALITY CONSTRUCTION & EASY MAINTENANCE + + Weave features an innovative tensioning mechanism that prevents the textile covering from sagging as a result of temperature and humidity changes over time. + + The tensioning mechanism allows for easy removal and replacement of the textile covering in the event of a design change or damage to the panel. + + High quality flexible hoses prevent leaks, can be rerouted as necessary, and allow access to individual panels for maintenance. + + Anodized aluminum components prevent corrosion to maintain the original, pleasing aesthetic. MINIMAL SPACE REQUIREMENT + + The reduced supply air volume of hydronic systems reduces ductwork requirements allowing smaller plenum heights, making radiant systems ideal for installation in tight spaces and creating the potential for lower construction costs, higher ceilings and more usable floor space. + + Air-handling equipment can be downsized, saving initial cost, energy costs and providing more flexibility in equipment location. ACOUSTIC PERFORMANCE + + Weave provides an acoustic panel solution for meeting the required sound absorption criteria in many spaces. Weave provides Class B acoustic performance and is typically applied with higher ceiling coverage than standard acoustic panels. + + The reduction in air-side mechanical equipment, inherent with radiant systems, results in less noise, and thus a quieter, more comfortable occupant experience. 6 For more information visit radiant@priceindustries.com v001

DIMENSIONAL DATA 83 86 120 130 MIN. 36 44 PERFORMANCE DATA Cooling performance Heating performance 120 240 110 100 220 200 180 W/m 2 Cooling 90 80 70 W/m 2 Heating 160 140 120 100 60 50 80 60 40 40 6 7 8 9 10 11 12 20 5 7 9 11 13 15 17 19 21 23 25 Mean Water Temperature - Air Temp (K) Mean Water Temperature - Air Temp (K) Tested to DIN EN 14240. Tested to DIN EN 14037. Sound Absorption Coefficient Rating according to ISO 11654: + + Weighted Sound Absorption Coefficient αw = 0.8 + + Sound absorption class: B v001 For more information visit radiant@priceindustries.com 7

Product Improvement is a continuing endeavour at Price. Therefore, specifications are subject to change without notice. Consult your Price Sales Representative for current specifications or more detailed information. Not all products may be available in all geographic areas. All goods described in this document are warranted as described in the Limited Warranty shown at priceindustries.com. The complete Price product catalog can be viewed online at priceindustries.com. Price is a registered trademark of Price Industries Limited. 2018. Printed in Canada. v001