ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.

Similar documents
Advanced Venting Systems

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

BDM Direct Vent systems are for use with direct vent gas fired appliances.

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

Z-FLEX LINERS AND DIRECT VENTING

PelletVent Multi-fuel venting system. UL 641.

NovaVent. Dimensional Data

Installation Instructions

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

Pellet Stove. Flex Pipe. Appliance Connector

Installation and Maintenance Instructions

CHIMNEYS AND VENTS CHAPTER 8

VP Pellet Pipe. For pellet burning stoves. FEATURES

CHAPTER 8 CHIMNEYS AND VENTS

Z-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Installation and Maintenance Instructions

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

Mitchell Metal Products, Inc.

PelletVent Pro horizontal Kit. PelletVent Pro. PelletVent Pro Vertical Kit - Cathedral. PelletVent Pro Pellet Chimney

CHAPTER 8 CHIMNEYS AND VENTS

CVS. Venting System for Category II, III, and IV gas appliances. Listed to UL-1738 and ULC S636.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

TYPE L VENT / VENT SYSTEM FOR PELLET BURNING APPLIANCES

VENT SYSTEM COMPONENTS

2012 INTERNATIONAL FUEL GAS CODE VENTS

Installation & Maintenance Instructions

Ventis Direct Vent. Installation Instructions

The intelligent alternative for flue gas venting systems

Pellet Vent INSTALLATION INSTRUCTIONS

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

Installation and Maintenance Instructions

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

Venting System For Pellet and Corn Stoves. PelletVent Pro. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Installation and Maintenance Instructions

Installation and Maintenance Instructions

CQS POWER VENT. General. Venting Requirements. Venting Instructions PREEVA Indoor, Power-Vented Heater Model PDH

MODEL CF CEILING SUPPORTED CHIMNEY

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

INSTALLER'S GUIDE MASONRY CHIMNEY VENT KIT WARNING: BAYVENT800B 18- CH23D2-05

SUBJECT: SELKIRK MODEL DT DIRECT VENT SYSTEM FOR PELLET & CORN FIRED APPLIANCES / TERMINATION CLEARANCES TO OPENINGS IN BUILDINGS

Saf-T Vent Model EZ Seal Plus/EZ 316 Single Wall Gas Vent Connector Chimney Liner & Special Gas Vent (USA) / Type BH Vent Class I/II (Canada)

INSTALLATION AND SERVICE MANUAL

5"x 8" DIRECT VENT INSTALLATION INSTRUCTIONS FOR DECORATIVE GAS APPLIANCES AND DIRECT VENT HEATERS APPLICATION

PelletVent Pro. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Model IVSI Positive Pressure Venting Systems

INSTALLATION INSTRUCTIONS

Z-DENS Polypropylene Vent Systems

Installation and Maintenance Instructions. Double Wall AL 29-4C Stainless Steel Special Gas Vent and Type L Vent

INSTALLATION AND SERVICE MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

SIZING HANDBOOK & APPLICATION GUIDE

SEPARATED COMBUSTION WARNING

DuraPlus HTC. All-fuel, double-wall chimney system. ULC S629.

EUTECTIC EC-10DV Series

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

H35 Direct Vent Gas Stove. 17,500 BTU/h (5.13 kw) 34,000 BTU/h (9.97 kw) 15,000 BTU/h (4.39 kw) 28,500 BTU/h (8.35 kw)

Installation Instructions. PolyPro Single-Wall Gas Vent System for Category II & IV Gas-Burning Appliances. PolyPro

Venting of Gas Fired Equipment RV

FasNSeal. Installation Instructions

Saf-T Vent SC Plus/SC 316

See Ordering Terms and Conditions for Details

DURAVENT POLYPRO VENTING PRODUCTS

EXHAUST SYSTEMS COMMERCIAL CHIMNEY LINING SYSTEMS.

R5-9/09. Price - $5.00

SIZING HANDBOOK & APPLICATION GUIDE

ASX7-5-IOM-3 J

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE

GB125 Concentric Vent

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

Gas Stoves. C34-10 Direct Vent Gas Stove. Side wall E F. Back wall F E. Model C34-NG10 C34-LP10

ASX7-4-IOM-6 J

Installation Instructions. Venting System for Pellet, Corn, Oil, and Biofuel appliances. PelletVent Pro

Crown Boiler Company

GOLD GV. Venting Supplement for 3 venting. Water Boiler Series 3 & 4

Adopting Agency BSC SFM. Adopt Entire Chapter X X X X X X X X X X Adopt Entire Chapter as amended (amended sections listed below)

INSTALLATION INSTRUCTIONS

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

ICC Model VIC SINGLE WALL SPECIAL GAS VENT INSTALLATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS

INSTALLATION INSTRUCTIONS

Installation Instructions for PTS Chimney Liners: Ventinox /DuraFlex Pro /DuraFlex SW

Do not use this vent pipe or fittings for venting incinerators of any kind.

POWER VENT. Standard Power Vent, Fan Type Unit Heaters: Standard Power Vent, Blower Type Unit Heaters: General WARNING WARNING. Model UDAP & Model APD

Forced Draft Boiler Flue Gas Venting: Problems & Solutions. Presented by Steve Connor and Patrice Gouin January 27, 2016

Venting Supplement Saf-T Vent 3" venting Special gas vent system vent and combustion air supplement for 3" diameter venting Hazard definitions

Pellet Vent INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION AND SERVICE MANUAL

Venting. Vent Material. Approved Venting Accessories Simpson Dura-Vent DV unless otherwise specified. Wall Thickness

Transcription:

ANY EVERY ONE ONE No matter what the venting application, from gas fired to oil to all fuel heating equipment, Z-FLEX is your one-stop solution.

Specialists in Flexible Z-FLEX has been providing flexible answers to gas, oil, pellet and wood venting applications since 1979. We have pioneered flexible chimney liner solutions and special gas vent (AL29-4C ). A variety of innovations in materials and construction have led to products that deliver: Superior performance and increased efficiency Easier handling and faster, simpler installation Greater reliability, safety and increased service life To that we add responsive customer service along with expert technical support. Z-FLEX is the leading manufacturer of specialty venting systems for furnaces, boilers, water heaters, oil heaters, fireplaces, and more. Advanced products for maximum performance Patented Triple-Lock Design for Strength Compressed to Lower Shipping Costs Best Available Materials/Alloys 20+ Years of Manufacturing Experience Immediate Availability (24 72 Hr. Lead Time) Listed by Underwriters Laboratories 1

Venting Solutions Safety Issues Since the federal government required modern heating equipment to achieve higher efficiencies in 1992, safely venting them has become more of a challenge. Today s more efficient equipment produces lower flue gas temperatures than pre-1992 equipment. The low temperature flue gas provides little natural draft in chimneys and is more likely to condense into an acidic, and corrosive, solution. The result can cause property damage, personal injury, or death. The natural laws of physics that control this phenomenon pertain to all gas and oil fired equipment. Our three major product lines; chimney liners, special gas vent (AL29-4C stainless steel), and flexible vent connectors are all designed to prevent flue gas condensation or protect against its corrosive effects. Most of the products Z-FLEX has developed are now recommended or required by the following national codes and testing agencies: 1992 National Fuel Gas Code Venting Tables for sizing Chimney Liners and Vent Connectors when adding or replacing equipment Insulated Connectors required in attics and other cold spaces 1997 NFPA 31 Installation of Oil Burning Equipment Venting Tables for sizing Chimney Liners International Approval Services (formerly AGA) June, 1996 IAS requires all Category III gas boilers and furnaces to use a UL 1738 approved vent system (like our Z-Vent) July, 1998 IAS requires all Category III gas residential unit heaters to use a UL 1738 approved vent system (like our Z-Vent) HEAT DISTRIBUTION 28% UP CHIMNEY 18% UP CHIMNEY 70% TO HOUSE 80% TO HOUSE 400-550ºF 2% STANDBY 275-350ºF 2% STANDBY LOWER EFFICIENCY before 1992 HIGHER EFFICIENCY after 1992 Higher Efficiency Produces Lower Stack Temperatures 2

Aluminum Chimney Gas Kit Rain Cap Wind-proof Bird Resistant Attractive Prevents Entrance of Moisture/Debris Flashing 16 x 16 Plate Galvanized Material Strong Fireplace Connector Gas Fireplace Kits only Flexible Aluminum Liner Special Characteristics Patented Triple-Lock Mechanical Joint Manufactured from Dead Soft Pure Aluminum Significant Advantages Greater Flexibility Exceptional Strength Corrosion Resistant Air-tight and Leakproof Vibration Deadening Properties Light Weight Highly Puncture Resistant High Pressure Rating Mortar Collar Simple to Install Clean Look Corrosion-resistant Material Z-FLEX CHIMNEY LINERS ARE LISTED WITH U NDERWRITERS L ABORATORIES, FILE MH 13681 3

GAS Liner Kits Z-FLEX Aluminum Chimney Liner Kits come complete with everything you need to quickly and easily install a professional venting system. Z-FLEX liner is manufactured by using a dead soft aluminum strip which is spirally wound and MECHANICALLY joined together forming an air-tight and leakproof TRIPLE-LOCK seam. Z-FLEX s specially designed deep corrugations provide for greater flexibility and ease of installation. The result is a clearly superior product offering incredible longevity. When to Z-FLEX a Chimney (FROM NATIONAL GAS CODE) When a masonry chimney has no liner at all When damage to existing chimney lining is evident When retrofit appliance has fan-assisted combustion and is vented alone When additional or replacement equipment is installed or an appliance is converted to gas from another fuel When the existing chimney is oversized relative to heating requirement 10 YEAR L IMITED WARRANTY Aluminum Liner Kit Kit Includes : 2-Ply Aluminum Liner Chimney Flashing Rain Cap Mortar Collar 3 Screws Part # 2GACKIT Dia. Lgth. Available in 3-10 Diameters 15-50 Lengths. Gas Fireplace Kit 2-Ply Aluminum Liner Chimney Flashing Rain Cap Fireplace Adapter (Single Appliance) 3 Screws Part # 2GAFKKIT Dia. Lgth. Available in 3-10 Diameters 15-50 Lengths. Additional Length Aluminum 2-Ply Liner Part # 2GAXXXX Dia. Lgth. Available in multiples of 5. Liner Coupling Part # 2CNNTRG Dia. Available in 3 10 diameters Custom sizes available. Used to attach two lengths of pipe. B-Vent Connector Part # 2CNNBFC Dia. Available in 3 10 diameters Connects B-Vent to Z-FLEX liner. Galvanized Y Part # 2WYEGAL Dia. Available in: 3 to. Connects two vent connectors to common vent. Nose Cone Part # 2NCXXXX Dia. Available in 3, 4, 5, 6, 7, 8, 10 Diameters. Z-FLEX Insul-Liner Pre-insulated Chimney Liner for Category I Gas Heating Equipment & Gas Fireplaces Insul-Liner is another simple solution from Z-FLEX. The National Fuel Gas Code (NFPA 54, ANSI Z223.1) recommends, but does not require, that liners be insulated in certain situations. A good rule of thumb is to use an insulated liner in exterior chimneys or when a brick chimney has no clay liner at all. The insulation will keep the flue gases warm to prevent condensation. Also refer to the equipment manufacturer s instructions for their recommendations. Insul-Liner can be substituted for B-Vent when relining a masonry chimney. Insul-Liner is insulated at the factory and protected with an outer aluminum jacket. This eliminates the time needed to insulate on the jobsite and prevents damage to the insulation during installation. Simply remove from the box and install. Insul-Liner Kit Insulated Aluminum Liner Chimney Flashing Rain Cap Mortar Collar 3 Screws Part # 02GIAKXX Dia. Lgth. Available in 3 20 Lengths. Insul-Liner Gas Fireplace Kit Insulated Aluminum Liner Chimney Flashing Rain Cap Fireplace Connector 3 Screws Part # 02GBAFK Dia. Lgth. Available in 4, 5, 6 Diameters 20 Lengths. 4

Stainless Steel Oil Kit Solid Fuel Kit Rain Cap Wind-proof Bird Resistant Attractive Prevents Entrance of Moisture/Debris Corrosion Resistant Flashing 16 x 16 Base Plate Stainless Steel Material Strong Corrosion Resistant Flexible Stainless Steel Liner Special Characteristics Patented Triple-Lock Mechanical Joint Manufactured from special high temperature and acid-resistant stainless steel exclusive to Z-FLEX Significant Advantages Greater Flexibility Exceptional Strength Corrosion Resistant Air-tight and Leakproof Vibration Deadening Properties Light Weight Highly Puncture Resistant High Pressure Rating Mortar Collar Convenient Clean Look Corrosion Resistant Material Easy to Install Double Wall Dripless Type C Connector Base Tee ( Cleanout) 3pc. with removeable snout and clean out All stainless steel Fail-safe mechanical connection from snout to body 5 NOTE: Some inspectors may require a cleaning tee on oil fired applications. Consult your local authority having jurisdiction. SS Kits may also be used with natural gas and propane equipment.

ALL FUEL Chimney Liner Kits Z-FLEX Stainless Steel Chimney Liner Kits come complete with everything you need to quickly and easily install a professional venting system. Z-FLEX is engineered to quickly conduct heat, assisting in a natural draft system. It is manufactured from special high temperature and acid resistant stainless steel exclusive to Z-FLEX. Z-FLEX s specially designed deep corrugations provide for greater flexibility and ease of installation. The result is a clearly superior product offering incredible longevity. When to Z-FLEX a Chimney When a masonry chimney has no liner at all When damage to existing chimney lining is evident When new burner is installed on existing equipment When firing rate of existing burner is reduced When a new appliance is connected to an existing chimney When the existing chimney is oversized relative to heating equipment Pellet, Oil & Gas Kit Stainless Steel Liner Chimney Flashing Rain Cap Mortar Collar Top Support Part # 2OILKIT Dia. Lgth. Available in 3-24 Diameters Lengths to 50. Solid Fuel Kit* Stainless Steel Liner Chimney Flashing Rain Cap Top Support Stacking Tee C-Connector Part # 2ZFKIT Dia. Lgth. Available in 3-24 Diameters Lengths to 50. *Insulating Blanket Kit must be installed for a woodburning application (U.S. only) Flexible S/S Round Part # 2ZLSSXX Dia. Lgth. Part # 2ZL294C Dia. Lgth. Available in 2, 3, 4, 5, 6, 7, 8, 9, 10 Diameters 2 24 Lengths in multiples of 5. Double Wall Dripless Type C Connector Part # 2CNNTAC Dia. Available in 2, 3, 4, 5, 6, 7, 8, 10 Diameters Used to mate Z-FLEX Liner to the T-Section, stove-pipe or when going through a fireplace adapter. 3-Piece 45 Adjustable Elbow Part # 2RE45XX Dia. Available in 2, 3, 4, 5, 6, 7, 8, 10 Diameters. 4-Piece 90 Adjustable Elbow Part # 2RE90XX Dia. Available in 2, 3, 4. 5, 6, 7, 8, 10 Diameters. Reducer/Increaser Reducer Part # 2RD (dia)r (dia)x Increaser Part # 2IN (dia)i (dia)x Available in 3-4, 4-5, 5-6, 6-7, 6-8, 7-8, 8-10 Diameters. Nose Cone Part # 2NCXXXX Dia. Available in 2, 3, 4, 5, 6, 7, 8, 10 Diameters To attach to liner, attach rope to cone and pull rope down chimney. Insulating Blanket w/wrap & Gear Clamps Part # 2INSKIT Dia. Includes 2 gear clamps per 5 section. Stacking Tee w/cap Part # 2ZRBTXX Dia. Available in 2, 3, 4, 5, 6, 7, 8, 10 Diameters. Note: Z-FLEX Tees are designed to be used with both the Flex and Rigid Lining Systems. Use Type C Connector to attach Flex to Tee section. Stainless Steel Chimney Flashing Starter Collar 16 x 16 Base Part # 2ZSCSXX Dia. 8, 9, 10 Diameters. Storm Collar Part # 2GAC Dia. Available in 2, 3, 4, 5, 6, 7, 8, 9, 10 Diameters To be used as a rain guard. Stainless Steel Locking Bands Part #2ZRLBXX Dia. 8, 10 Diameters. Stainless Steel Rigid Liner Part # 2ZR321X Dia. Lgth. 8, 9, 10 Diameters. Rain Cap Part # 2RNCAPS Dia. 8, 10 Diameters. Top Support Part #2ZTSXXX Dia. 8, 10 Diameters. LifeTime L IMITED WARRANTY Z-FLEX CHIMNEY LINERS ARE LISTED WITH U NDERWRITERS L ABORATORIES, FILE MH 13681 6

GAS Flexible Gas Vent Connector System Insul-Vent TM is a double-wall insulated vent connector. Insul-Vent is designed to make insulated connections between appliance and common vent (i.e. B-Vent, masonry chimney, or Z-FLEX chimney liner products), easy and economical. Simply cut to desired length and attach quickconnect ends. No drilling or screwing is required. Plus it eliminates costly elbows and accessories. Single-Vent TM is a single wall flexible vent connector. Single-Vent, like Insul-Vent, is designed to make difficult installations easy and economical. It replaces rigid single pipe as a vent connector. Both products, like all our other flexible products, are manufactured with our patented triple lock seam. Insul-Vent and Single-Vent are UL listed. Insul-Vent TM Double Wall Insulated Vent Connector Kit Length of Double Wall Flex Appliance Connector Universal Connector Part # 2ZIKXXX Dia. Lgth. Single-Vent TM Single Wall Vent Connector Kit Length of Single Wall Flex Appliance Connector Universal Connector Part # 2SVKXXX Dia. Lgth. Insul-Vent Universal Connector Part # 2IVUCXX Dia. The universal connectors fit any type of single wall pipe, any Type B-Vent or Z-FLEX Chimney Liner. Insul-Vent Appliance Connector Part # 2ZICPRP Dia. Additional Length of Insul-Vent Part # 2INSGAC Dia. Lgth. TYPICAL APPLICATION No drilling or screwing required No costly elbows Cut to length on site 1 clearance to combustibles Single-Vent Universal Connector Part # 2SVUCXX Dia. The universal connectors fit any type of single wall pipe, any Type B-Vent or Z-FLEX Chimney Liner. Single-Vent Appliance Connector Part # 2ZSCPRP Dia. Additional Length of Single-Vent Part # 2GAXXXX Dia. Lgth. I NSUL-VENT AND S INGLE-VENT ARE LISTED WITH U NDERWRITERS L ABORATORIES FILE MH 17194 7

OIL Flexible Oil Vent Connector System Oil-Vent double-wall insulated vent connector is designed to make insulated connections between appliance and common vent (i.e. L-Vent, masonry chimney, or Z-FLEX chimney liner products), easy and economical. Simply cut to desired length and attach quick-connect ends. No drilling or screwing is required. Plus it eliminates costly elbows and accessories. Equivalent to Type L. Oil-Vent single wall flexible vent connector is designed to make difficult installations easy and economical. It replaces rigid single pipe as a vent connector. Both products, like all our other flexible products, are manufactured with our patented triple lock seam. Double-Wall and Single-Wall Oil-Vent are UL listed and offer 1 clearance to combustibles. Oil-Vent TM Double Wall Insulated Vent Connector Kit Length of Double Wall Appliance Connector Universal Connector Part # 2OVIKIT Dia. Lgth. Oil-Vent TM Single Wall Vent Connector Kit Length of Single Wall Appliance Connector Universal Connector Part # 2OVSKIT Dia. Lgth. Quick Connect Ends Oil-Vent Double Wall Universal Connector Part # 2OVIUCX Dia. The universal connectors fit any type of single wall pipe, any Type L-Vent or Z-FLEX Chimney Liner. Oil-Vent Double Wall Appliance Connector Part # 2OVIACX Dia. Additional Length of Oil-Vent Double Wall Part # 2OILVENT Dia. Lgth. Oil-Vent Single Wall Universal Connector Part # 2OVSWUC Dia. The universal connectors fit any type of single wall pipe, any Type L-Vent or Z-FLEX Chimney Liner. Oil-Vent Single Wall Appliance Connector Part # 2OVSWAC Dia. Additional Length of Oil-Vent Single Wall Part # 2ZLSSXX Dia. Lgth. O IL I NSUL-VENT AND O IL S INGLE-VENT ARE LISTED WITH U NDERWRITERS L ABORATORIES FILE MH 17194 8

SPECIAL Z-Vent III Special Gas Vent for Category II, III, IV Heating Equipment Connects in a Snap! Simple gasketed connection no sealant needed* Features the highest pressure rating in the industry The only metallic special gas vent you can cut to length on site New fusion welded pipe seams for a smoother finish and better fit 1 clearance to combustibles can be installed where clearances are minimal * Patent Pending 9

GAS VENT Features: Gasketed connections The highest pressure rating in the industry Fusion welded pipe seams The only metallic special gas vent that can be cut to length on site 1 clearance to combustibles Benefits: No sealant required No cure time, no call backs More than 3 times the industry standard Provides an air-tight seam, smooth finish and a better fit Being able to cut the product in the field will save you time and money. Pipe available from 6 thru 10 Can be installed with minimum clearance to combustibles *The lengths of pipe may be cut on non-expanded end using aviation snips or a hacksaw (24 tpi). The cut end must be filed or sanded smooth before joining. Z-Vent is manufactured using AL29-4C advanced ferritic stainless steel** with unmatched corrosion resistance for use with condensing furnaces and boilers. Z-Vent was developed in the early 1980 s and has thousands of field installations to date. Z-Vent is now manufactured utilizing a fail-safe gasket connection. No sealant is required. Z-Vent is suitable for use with boilers, high efficiency furnaces, pool heaters, unit heaters and water heaters. See website for list of equipment 15 YEAR LIMITED WARRANTY Typical Installations:* HORIZONTAL DRAINPIPE B PIPE* B Rain Cap A A Firestop Spacer/Support Flashing 4 Min. Air Space Female End To Appliance Male End Catalogue No. Size A B 2SVEDWC 3 3 8.5 2SVEDWC 4 4 10.5 45 DEG. ELBOW Catalogue No. Size A 2SVEPWC03 3 3 2SVEPWC04 4 4 90 DEG. ELBOW Gear Clamp Joint Detail B A B A Firestop Spacer Hanger Straps Hanger Strap One Piece Drain Tee Minimum above ground or normally expected snow accumulation level Termination 48 max. C Catalogue No. Size A B C 2SVEEWC0345 3 3 8.25 5.5 2SVEEWC0445 4 4 7 5.7 Catalogue No. Size A B 2SVEEWC0390 3 3 8.25 2SVEEWC0490 4 4 7.2 Elbow To drain dispose of condensate according to local codes Drain Trap Horizontal run 1/4 rise/ft. Appliance Vertical Elbow Appliance Wall Thimble Drain Trap To drain dispose of condensate according to local codes Side Wall **All drawings are for illustrative purposes only. Please refer to guide for specific U.L. installation instructions. Always defer to local building codes. **AL29-4C is a registered trademark of Allegheny Ludlum Steel Corporation 12 VERTICAL DRAIN/TEE B A Catalogue No. Size A B 2SVEVWC03 3 3 7.5 2SVEVWC04 4 4 7.5 B TERMINATION A Catalogue No. Size A B C 2SVSTTX03 3 3 6 6.25 2SVSTTX04 4 4 7 9.25 *Pipe lengths available 6, 1, 2, 3, 4, 5, 8, 10 Appliance connectors available for most equipment. Please refer to price guide. C 10

All Fuel Oval Liner System Flexible S/S Oval to Round Part # 2ZLSSOR Dia. Lgth. Available in 6, 7, 8, 10 Diameters Note: To be used in those areas that are re-sealable in one application. Oval accessories available. Flexible S/S Full Oval Part # 2ZLSSOX Dia. Lgth. Available in 6, 7, 8, 10 Diameters Note: Oval accessories available. Stainless Steel Dripless Type A Oval Connector Part # 2CNNTRA Dia. Available in 6, 7, 8, 10 Diameters Used to join Z-FLEX Oval Liner to Oval T-Section and Oval to Oval Liner or when going through a fireplace adapter. Stainless Steel Single Oval Base/Tee Part # 2ZRBTOX Dia. Available in 5, 7, 8, 10 Diameters. Oval to Round Adapter Part # 2ZRORAX Dia. Available in 6, 7, 8, 10 Diameters. Round to Oval Adapter Part # 2ZRROAX Dia. Available in 6, 7, 8, 10 Diameters. Liner Finders The easy-to-apply solution Apply the right liner every time with LINER FINDER from Z-FLEX. Our Gas and Oil Liner Finders make it fast and easy to match the right Z-FLEX product and size to the liner application. The convenient slide rule design is simple to use, portable, and foolproof. U.S.A. 20 Commerce Park North, Bedford, NH 03110-6911 Tel (603) 669-5136 1-800-654-5600 Fax 1-888-889-3539 CANADA 452 Attwell Drive Etobicoke, ON M9W 5C3 Tel (416) 679-0045 Fax (416) 679-0051 E-mail: sales@z-flex.com Website: www.z-flex.com 09/01