Assigning profiles to an e-stack or Passive Stack (S1500, S1200 & R-Series)

Similar documents
Assigning profiles to a Breathing Buildings NVHR Unit (NVHR900 & NVHR1100)

Copyright 2017 Integrated Environmental Solutions Limited. All rights reserved.

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Autodesk Moldflow Insight AMI Molding Window Analysis

Daikin VRV Sizing & Simulation Plug-in User Guide

INDOOR CLIMATE OF A SINGLE ZONE

Integration Guide AXIS Camera Station and AXIS A8004-VE

Daikin VRV Systems Plugin VE2012 User Guide

Installing ProSeries 2005

Installing ProSeries software for stand-alone use

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

INTELLIGENT VENTILATION CONTROLS: NATURAL AND HYBRID SYSTEMS

rvm4c Installation Guide Remote Video Module

HYBRID PLUS2 AIRCOOL VENTILATORS

INTELLIGENT VENTILATION CONTROLS NATURAL AND HYBRID PLUS SYSTEMS

Residential Smart Thermostat Qualified Products List Updated 5/1/2017

Alarm System Example

Avigilon Control Center System Integration Guide

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

Metasys Integrator TITUS Application

Modeling projects that require very tight space temperature control

Before you install ProSeries Express Edition software for network use

Setting up and Managing Alarms in McAfee ESM 10.x

Eco Active H E A T R E C O V E R Y S Y S T E M S H Y B R I D U N I T. W: T:

Installing ProSeries 2004

Avigilon Control Center 5 System Integration Guide

Synergy 405PLUS User Guide Manual

ThermoBarScan TM Electronics UK Ltd INSTRUCTION BOOKLET

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

Manage Alarm Profiles

Avigilon Control Center 5 System Integration Guide

Avigilon Control Center System Integration Guide

ACTIVE VENTILATION SYSTEMS

TRACE 700. Slide 1. Hello, my name is Nick Cavitt and I m a marketing engineer in the C.D.S. group at TRANE.

Milestone XProtect. Central 3.7 User s Manual

Selected Laboratory Energy Efficiency Measures

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat

CLIMATE SEPARATION SOLUTION. SensAir

ApacheHVAC in VE 2012

TV2 Clean Room Monitor

Step 1 - Install ProSeries Basic software

RVRC Training Manual Fast Trace Installer Menu

Before you install ProSeries software for network use

HikCentral Web Client. User Manual

Modelling Appliance Loads in Multi-Unit Residential Buildings

Bosch TCU Integration Module Administrator's Guide

PHD Dolphin Installation

Tutorial: How to Download and Install Lumberyard v or greater

Tstat9. Bacnet Thermostat

AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS

Avigilon Control Center 5 System Integration Guide

Ventilation & Heat Recovery. The whole house system from OMNIE

Before you install ProSeries software for network use

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

Solar thermal solutions within the Energy Labelling Context

Cooling the Data Center

Pack Calculation Pro. Users guide. Version Morten Juel Skovrup

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

Patriot Systems Limited

Updates to the Ground Infiltration Module in InfoWorks ICM 8.0

1 Air Handling Units In ICE

How can you reduce radon in a home?

AIR CURTAIN GUIDE WHAT IS AN AIR CURTAIN?

The Corbioli House is a single-family house situated

Advanced Installation and Configuration Instructions

Network Hardware and wiring (quiz)...

ArchestrA Direct Connect

Hello, my name is Sarah Hilden and I am a Marketing Engineer in the C.D.S. group at Trane.

MicroTech Unit Ventilator

Comfortable indoor climate regardless of the season

External insulated volume. control damper

ApacheHVAC User Guide Part F: Loads Analysis and Reporting Tools

DX-9100 Applications from Engineering Services

Avigilon Control Center System Integration Guide

HikCentral Web Client. User Manual

MULTISITE. Multisite Activation. Microsoft Dynamics AX White Paper

New Features. IES Virtual Environment 6.4

CLIMATE SEPARATION SOLUTION. SensAir

Installation, Configuration and User Manual

Kaleidescape Programming Manual for Elan Home Systems

Building Regulations Approved Document F1 Means of Ventilation April 2006

Microelectronic Programmable Thermostat Owner s Manual. 1 J.H Form Number

Ion Gateway Cellular Gateway and Wireless Sensors

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

DEEP SEA ELECTRONICS PLC DSE94xx Battery Charger Series Configuration Suite PC Software Manual

WeatherLink for Alarm Output Addendum

Product Manual SZ1009

ApacheHVAC User Guide Part B: Equipment, Loops, Components, and Controls

Configuring IndigoVision Control Center. Configuring IndigoVision Control Center

Milestone XProtect Alarm Matrix Integration 1.0

Metasys System Extended Architecture Fire System Integration Using the IFC BACnet Gateway

Welcome to ProSeries Express Edition tax software

Simplex Panel Interface Guide

TV2 Room Pressure Monitor Quick Start Guide

Help. Help Software Tutorial. Building a Load Sizing Project with an SETC Humidifier and a mini SAM-e Distributor

Complete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks

VENTILATION = WELL-BEING

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

AK SM 800 Commissioning Guide

Elegance. SMT-700 User manual. Ver

Transcription:

Assigning profiles to an e-stack or Passive Stack (S1500, S1200 & R-Series) This document provides a comprehensive step-by-step guide to assigning opening profiles for an e-stack to an existing IES VE model. Should you have any questions please contact Joe Clawley or Matthew Waterson at joe.clawley@breathingbuildings.com / matthew.waterson@breathingbuildings.com, or call the office on 01223 450 060. Table of Contents Table of Contents... 1 Modelling natural hybrid ventilation in IES VE... 2 Download, unzip and attach the e-stack geometry file... 3 Modelling functionality of the e-stack in IES VE... 3 Importing e-stack profiles into your project... 4 BB e-stack Damper Profile setup... 8 BB e-stack Auxiliary Ventilation Profile setup... 10 BB e-stack Windows Profile setup... 12 Heating and Cooling defaults within the building... 13 1

Modelling natural hybrid ventilation in IES VE One of the big advantages of the e-stack system over other natural ventilation systems is that in the winter, we do not bring in air via opening windows, as this requires a potentially large amount of preheating energy. This would of course make for a less energy efficient and environmentally friendly solution to keeping temperatures and CO2 levels comfortable. Instead we operate in mixing mode where we bring air at high-level and mix it with the warm room air to create a tempered air stream which is comfortable for occupants. However, as IES VE does not take into account the thermal comfort in the context of cold draughts, this major advantage does not need to be modelled. IES VE models a room with a bulk air temperature, which means the requirement to preheat the incoming air (and associated energy consumption) of other conventional natural ventilation systems is not included in the IES model. It is however worth noting that in a real-world situation our systems would have you covered to comply with the new BB101 regulations. The e-stack system is not a heat exchanger, and therefore cannot be modelled as a mechanical system with heat recovery. The system saves energy by bringing air into the space and mixing it with the room air to reduce cold draughts. This document explains in detail how to set up an E-Stack unit in in IES VE, which for the purpose of this user guide we have selected the S1500 unit for this example. 2

Download, unzip and attach the e-stack geometry file Start by creating the model of your room or building within the VE. Once you have your building set up, with the necessary construction properties applied, you are ready to add an e-stack system. http://www.breathingbuildings.com/wp-content/uploads/2017/04/adding-an-e-stack-unit-to-amodel.pdf Follow the above link to our dedicated guidance, download Importing & Installing the E-Stack Geometry Files, then follow the instructions to attach the e-stack to your model as shown in the image below. Modelling functionality of the e-stack in IES VE The functional control of an e-stack system takes into account: modulating damper control, window opening, fan operation, temperature sensing, CO2 sensing, and timed functions. The complexity of this system can be difficult to model in any dynamic simulation software. We have therefore created all the profiles necessary and included them in the cabinet file folder. The geometry file contains an easily importable e-stack unit which can be copied as many times as required. 3

Importing e-stack profiles into your project Once the geometry file has been imported into your project, you ll be in a comparable situation as shown below, with the e-stack attached to the roof of the required room: Next you will need to import the profiles, in this case from the BB S1500 [VE2017] cabinet file using the master template Wizard option as shown below: 4

Click the find folder button: Find the relevant unit folder, in this case the BB S1500 folder in the location it was saved after being downloaded from our website, and select the VE Document entitled BB S1500 : 5

Click the Import data button: Select the MacroFlo Openings Templates, Apache Profiles, Air Exchanges and MacroFlo Openings options as shown below: Click next, and then Start : 6

Your IES VE file will now contain the Breathing Buildings e-stack profiles required to control the unit. The profiles have been prefixed, in this case with BB S1500 for the S1500 e-stack unit, to make them easy to identify and group within the Profiles Database: The profiles included are daily and weekly profiles culminating in: e-stack (BB S1500) Damper Profile Damper control of the actual e-stack unit in your project e-stack (BB S1500) Fan Profile (this accounts for all fan operations) Auxiliary ventilation control e-stack (BB S1500) Windows Profile Window opening profiles as controlled by the unit e-stack (BB S1500) School Term weekly Profile UK school term times 7

BB e-stack Damper Profile setup Through the MacroFlo tab select the four opening doors of the S1500 unit. Click the edit selection set opening types button as shown below: Select the appropriate e-stack unit roof cowl type (mushroom or penthouse) and click replace. 8

You now have the Macroflo opening profiles set up correctly. This will enable the roof vent to open and close automatically, depending on internal and external conditions, replicating the real-life operation of our e-stack system. 9

BB e-stack Auxiliary Ventilation Profile setup Breathing Buildings' e-stack systems are hybrid natural ventilation systems, which include lowpowered fans, primarily there to enable mixing ventilation in colder weather - Breathing Buildings' energy saving method for mitigating cold draughts whilst ensuring occupancy comfort. Since these low-powered fans are present, it makes sense to utilise them, wherever possible, to assist the predominantly natural ventilation airflow in warmer weather - i.e. summer mode. In summer mode, we are able to run the fans to assist the natural ventilation airflow. This fan assistance should be represented within IES as an auxiliary ventilation within the room. The fans in the unit are modelled in IES as auxiliary ventilation within the room, added through the building templates manager Air Exchanges tab as shown below (Note Please skip the BB e- stack Auxiliary Ventilation Profile setup section for passive stack only (not fans) versions of these units): Click the Add/Edit button. Add the BB e-stack Fan profile to the template. 10

Below is a completed version of all auxiliary ventilation modules required: By allowing for the Infiltration you can avoid CO2 being trapped in the room during unoccupied hours, this is a more realistic model of the building and we recommend 0.25 ach as is the default for IES VE. All air exchanges through the unit have now been set up: Click save and OK. 11

BB e-stack Windows Profile setup The e-stack system is designed to perform optimally when working in conjunction with openable windows at low-level. In a real building, the opening and closing of these windows would be done by the room occupants. When simulating the building, however, we need to set the window opening profiles in line with the internal and external conditions. The profiles you need are all included in the CAB file you downloaded and imported into your IES. You simply need to assign them to the windows in your building by selecting the BB S1500Window Profile in the area of MacroFlo Opening Types as detailed below. Please ensure the hours for when windows can be used are altered accordingly in the highlighted window profile below (currently assumed to be 9am to 4pm). Click Save and OK 12

Heating and Cooling defaults within the building IES VE will automatically set your room up to have heating set at 19 degrees continuously, and cooling set at 23 degrees continuously throughout the year. These should be changed to suit the building using the Space Conditions tab of the building template manager. Please note that in the summer months an automatic night cool strategy operates, the heating profile should be chosen in order not to conflict with this scheme. 13