SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

Similar documents
1 DOCUMENT REVISION CONTROL ELEMENTS... 9

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

ENERGY TOP. Condensing boiler solutions

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

CRIMSON & CRIMSON MAX

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

heat interface units A BOILER WITHOUT A FLAME

HT V2 HT Split

Installation Guide. Termix Distribution unit. 1.0 Table of Contents. 1.0 Table of Contents

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Heating and D.h.w. Controller RVL482 Basic Documentation

SHERPA. Air-water split heat pump. COP > 4 ACS a 60 C

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

HEATING REGULATOR EPC11 End user manual.

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

ST 53.1 User s manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

WHE 2.24 / WHE 2.24 FF

ThermoDual Domestic hot water charging system

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

Planning guide. (2010/09) en

INSTRUCTION FOR THE USER THC V E OIL BLU

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

T. +44 (0) E.

LZT High efficiency air to water heat pumps with E.V.I. compressors

ModuSat TP. Energy. Heat Interface Units

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Operating instructions

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

STREBEL S-CB + Cascade Kits

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

USERS MANUAL FOR GAS BOILERS

Solar Thermal Energy

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

Parameter guide 95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER WARNING WARNING

RVL481. Heating Controller. including d.h.w. heating

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

SPECIFICATIONS - NIKE

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

Solar heating systems

AFUE 95% Heating Input 50,000 to 200,000 Btuh

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

ACCUMULATION OF EUROPEAN CLASS

Project Name: Location: Engineer: Contractor: I. GENERAL

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

HIGH EFFICIENCY CIRCULATORS

INDUSTRIAL RANGE ACCESSORIES AND COMPONENTS

Product Data Sheet Refrigeration Dryer DFX

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

Gasketed and brazed plate heat exchangers

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Caleffi Hydronic Solutions Contact: Rex Gillespie, Director of Marketing Phone: (414)

Installation, operating and servicing instructions

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

1 VICTRIX ZEUS Superior kw I features

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

Programmable Towel Radiator Manual

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Technical Data Manual

BF1 GLASSLINED CYLINDERS WITH REMOVABLE STAINLESS STEEL HEAT EXCHANGER ( LITRES)

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

Operating instructions

LZA High efficiency air to water heat pumps with HP compressor

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

HW 22 District heating substation for indirect heating and domestic hot water systems

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

- Data Brochure Universal Reset Module 422

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Solar water heating system

INSTALLATION AND OPERATING INSTRUCTIONS BIOCLASS HM OD (FOR EXTERNAL USE)

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Installation, Operating and Servicing Instructions

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

AQUAMATIC HOT WATER IS YOUR NEW WELLNESS. Instant producer of sanitary hot water

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Herz York Direct Heat Interface Unit

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

QTS SELECTION TECHNICAL BOOKLET

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Akva Lux TDP-F District heating flat station for direct heating and domestic hot water systems

ELECTRIC BOILERS FOR CENTRAL HEATING

ModuSat TP. Energy. Heat Interface Units

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

Transcription:

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

INDEX Ed. 20150422 GENERAL INFORMATION... 2 Before installing... 2 Materials and PED (97/23/CE) Standards... 3 SKID-TYPE DISTRICT HEATING SUBSTATIONS... 4 Technical Features... 4 SKID-TYPE SUBSTATION FOR HEATING USE ONLY... 5 Hydraulic Diagram... 6 SKID-TYPE SUBSTATION FOR HEATING AND DOMESTIC HOT-WATER PRODUCTION (with heat exchangers in parallel configuration)... 7 Hydraulic Diagram... 8 WALL-MOUNTED DISTRICT HEATING SUBSTATIONS... 9 Technical Features... 9 WALL-MOUNTED SUBSTATION FOR HEATING USE ONLY...10 Capacities and Dimensions... 10 Hydraulic Diagram... 11 WALL-MOUNTED SUBSTATION FOR HEATING AND DOMESTIC HOT-WATER PRODUCTION (with heat exchangers in parallel configuration)...12 Capacities and Dimensions... 12 Hydraulic Diagram... 13 WALL-MOUNTED SUBSTATION FOR HEATING AND DOMESTIC HOT WATER PRODUCTION (with heat exchangers in series configuration)...14 Capacities and Dimensions... 14 Hydraulic Diagram... 15 EXAMPLES OF SYSTEM LAYOUTS... 16 LEGEND...16 DIAGRAM No. 1...17 DIAGRAM No. 2...17 DIAGRAM No. 3...17 DIAGRAM No. 4...18 DIAGRAM No. 5...18 DIAGRAM No. 6...18 DIAGRAM No. 7...19 This document was created by the TECHNO SYSTEM Technical Office. All rights reserved. This document may not be reproduced in whole or in part without explicit written authorization by Techno System. Techno System also reserves the right to modify the technical features and construction data of any product referred to herein at any time and without notice.

- 1 -

GENERAL INFORMATION TECHNO SYSTEM, a long-time leader in the district heating sector, builds skid-type substations (for medium and high capacity applications) complete with all the components needed for ensuring safety and for heat measurement and regulation as well as fittings for remote management. The substations are compact, can be completely dismantled, and can be installed even in small or difficult-to-access spaces. The TECHNO SYSTEM district heating substations are supplied as pre-assembled, pre-cabled units that interface with the vector fluid delivery system (superheated or hot water) distributed by the energy production and/or supply companies to permit the user system which operates at a lower temperature and pressure to draw off the quantity of energy (heat) needed for heating and/or production of domestic hot water. The district heating substation is a thermal exchange system comprising plate heat exchangers supplied by superheated or hot water for heating via radiators, fan coils, floor panels, etc., and/or for production of domestic hot water (DHW). The heat exchangers are the TECHNO SYSTEM plate type, correctly dimensioned in accordance with project data and technical specifications. The electrical panel supplied with the substation is the standard TECHNO SYSTEM panel for DHS substations, featuring small size and full conformity with pertinent laws, standards, and regulations. The TECHNO SYSTEM substations are pre-assembled and tested at our plant and can be supplied complete with insulation on the piping and heat exchangers. The overall dimensions of the substations reflect the principles of maximum compactness typical of all TECHNO SYSTEM DHS substations. Any special adaptations to the substations are subject to separate estimate. For building its DHS substations, TECHNO SYSTEMS uses only materials conforming to the requirements of the Pressure Equipment Directive ( PED Directive ) - 97/23/EC - and in compliance with the provisions of the Italian Raccolta R Edition 2009. The procedures and welding equipment used are DNV-qualified in accordance with EN 15614 and EN 287 PED. Where applicable, x-ray inspection of the piping welds is conducted in accordance with TECHNO SYSTEM standard procedures: 10% of the welded joins on category PED I, II, III, and IV substations are inspected, while no x-ray inspections are called for in the case of substations covered by Art. 3 3, which are also welded in accordance with EN 15614 and EN 287 PED standards. The construction materials and production and testing methods used for building, testing, and outfitting the TECHNO SYSTEM substations (carrying ISO 9001-2008 and PED certification issued by DNV) all meet the standards set by the PED Directive. Each substation is supplied complete with statement of PED compliance. In the wall-mounted DHS substations, the heat exchangers (in series or in parallel) are inserted in a loadbearing structure in hot-galvanized sheet with jacket (for the wall-hung version) or with epoxy- finished sheet-metal cornice (for the recessed version). In the version featuring parallel exchangers, heating may operate simultaneously with DHW production, while DHW takes priority over heating in the version with series-mounted exchangers. In the skid-type DHS substations, the heat exchangers are installed on a load-bearing carbon-steel base with singly-adjustable feet. All the TECHNO SYSTEM district heating substations are equipped with an electrical control panel featuring a customizable PID (Proportional Integral Derivative) programmable logic digital controller with the most widely-used combinations pre-programmed. Before installing Since there do not exist any technical standards making explicit reference to particular sites in which to install the substation for safety reasons, it is the responsibility of the system designer and/or installer to select the most suitable location for installation. It is nevertheless prudent to not install the substation in direct contact with walls and/or other equipment installed in the boiler room in order to guarantee the best possible access in view of future routine and extraordinary maintenance operations. Insofar as concerns the electrical supply system, refer to Italian Law no. 46/90 of March 1990 and to the pertinent CEI (IEC) standards. Also remember that this type of heat generator is subject to the provisions of Italian Presidential Decree no. 412/93 concerning energy consumption for thermal uses in buildings. - 2 -

All the pre-assembled substations built by TECHNO SYSTEM comply with the Pressure Equipment (PED) 97/23/EC, Low Voltage 73/23/EC, and Electromagnetic Compatibility 89/336/EC Directives, are supplied complete with all relevant documentation (Statement of PED Compliance, CE mark, use and maintenance manuals) called for by applicable laws, regulations, and standards, and are fully compliant with the prescriptions of said documents. All the pre-assembled substations built by TECHNO SYSTEM are constructed in conformity with the provisions of the Italian Raccolta R Edition 2009. Materials and PED (97/23/CE) Standards Following the entry into force of the Pressure Equipment Directive (PED - 97/23/EC), TECHNO SYSTEM accelerated its ongoing quest for quality al all levels, to ensure full compliance with the Directive of all the models of TECHNO SYSTEM heat exchangers. For the company, this step entailed obtaining certification of its Quality System certification and, at the same time, Form H and H1 PED certification. The ensuing comprehensive revision of heat exchanger design and construction entailed redefinition and consequent improvement of all the safety and quality parameters, through use of materials with excellent mechanical properties. - 3 -

Circuit Inlet SKID-TYPE DISTRICT HEATING SUBSTATIONS Secondary Circuit Flow Outlet Circuit Flow Outlet Secondary Return Inlet Technical Features Maximum operating pressure DHS network 16 bar (optional PN25) Maximum operating pressure Heating side according to demand (max 8 bar) Maximum operating pressure DHW side 6 bar (where applicable) Maximum differential pressure on primary side 16 bar Minimum differential pressure on primary side close to substation 2 bar Maximum pressure drop on primary side 1bar Test pressure (differential) 1.43 times design pressure. Protection Class IP54 Electrical supply voltage 230 V (optional 380 V) Electrical supply frequency 50 Hz The district heating substation is a fully pre-assembled, pre-cabled unit for heat transmission, featuring high yield and maximum operating safety. The base is built of steel sections which house: o Inspectable plate heat exchangers (corrugated or smooth plates) or braze welded heat exchangers o Safety accessories: Safety valves, ISPESL certified (PED) Expansion tank o Monitoring accessories: Pressure gauges Thermometers Immersion sensors o Protection accessories: Safety thermostats Temperature-control thermostat (for hot water) or regulation and safety dual thermostat (for superheated water) o Control accessories: Two-way seated poppet valves Electrical servo control for the above-mentioned valves o Automatic control accessories: Thermal regulation station for monitoring temperatures at various points and programming and defining parameters for the physical and electrical values to be managed. o Main electrical control panel On request, the skid-type district heating substations may be supplied fully insulated (exchanger and piping) or partially insulated (exchanger only or piping only). N.B. Substations of this type may also be constructed for domestic hot water production alone. Such a version does not include the electrical panel, thermal regulation unit, or the external sensor. The off-site elements (as shown in the diagram below) must be connected to the thermal regulation panel of another substation designed for heating use only. - 4 -

SKID-TYPE SUBSTATION FOR HEATING USE ONLY This type of substation is suitable for high and medium capacity systems supplied by superheated water or hot water. It is designed for heating use only and can be equipped with the SIEMENS RVD (or similar) controller or with the TECHNO SYSTEM TSRE 010 temperature-control system. These substations integrate perfectly with systems for instantaneous production of domestic hot water with accumulation tanks, boilers, solar panels, and for pool heating systems, for example through application of specific modules units produced by TECHNO SYSTEM (refer to the examples included as attachments in this folder). With this type of substation, users can: directly set the heating set-point using easy-access dedicated pushbuttons. (TSRE 010) manage heating independently, with separate onboard timers and weekly programs (TSRE 010) manage heating by external thermostat/timer-thermostat or on the basis of a weekly schedule programmed in the controller (on/off settings at half-hour intervals) (TSRE 010) set SUMMER or WINTER parameters (heating deactivated in SUMMER mode) manage heating temperature by the fixed-point or climate-curve method lock the heating-side set-point for systems serving floor panels (TSRE 010) set an ANTI-SCUFF cycle for the HEATING side pump (if installed) when system is in SUMMER mode set an ANTIFREEZE cycle with minimum threshold maintain temperature in the primary circuit via hydraulic bypass (with ball valve) or managed by the regulator (with times, intervals, and quantities set via the onboard calendar) (TSRE 010) connect a safety thermostat on the heating side (for floor-panel systems) featuring cut-in signal (by acoustic alarm and display message) signal sensor malfunction (by acoustic alarm and display message) (TSRE 010) signal excessive pressure in the heating circuit by acoustic alarm and display message and signal low water level in the heating circuit (and shutdown of the heating side pump, if applicable) by acoustic alarm and display message (TSRE 010) reset the values to factory defaults. Additionally, this type of substation is prepared for installing devices for: limiting the flow rate on the DHS side limiting the return temperature on the DHS side, with sensor malfunction signal (by acoustic alarm and display message) remote reading of the thermal energy meter remote control managing a GSM or PSTN modem connection, which permits sending SMSs or e-mails for notifying alarms or malfunctions (TSRE 010). Heating Capacity (kw) Design Temperature ( C) Overall dimensions (mm) Length x Height x Width Connections on Side Connections on Secondary Side Empty Weight (kg) 200 100 1390x1830x500 DN40 DN50 250 400 100 1560x1870x560 DN50 DN65 400 600 100 1770x1870x610 DN65 DN80 450 800 100 1730x1870x615 DN80 DN100 500 1000 100 1935x1890x1000 DN80 DN100 800 200 140 1160x1680x500 DN25 DN50 200 400 140 1405x1870x550 DN40 DN65 350 600 140 1520x1870x600 DN50 DN80 400 800 140 1780x1870x600 DN50 DN100 450 1000 140 1915x1840x1000 DN65 DN100 750 NOTE: each substation is dimensioned on the basis of the pressure on the two circuits, the thermal head, and/or the heating capacity requested by the customer. For this reason, the overall dimensions of the substations are subject to change, case by case; the maximum measurements are suggested by the above table (calculation of table values is based on TECHNO SYSTEM standard parameters). Wall-mounted substations are available for heating capacities equal to or less than 150 kw. - 5 -

Hydraulic Diagram Secondary Delivery Secondario Secondary Return COMPONENTS OPTIONALS 1 Plate heat exchanger for HEATING ON/OFF VALVE SET 3 Servo-controlled valve for HEATING 25 On/off butterfly valve, HEATING side 5 Servomotor for HEATING MISCELLANEOUS 7 Thermal energy meter 27 Filter, HEATING side 8 Controller 9 Electrical panel 10 On/off ball valve on PRIMARY side 11 PRIMARY side filter 12 Safety valve 13 Temperature sensor on PRIMARY side 14 Temperature sensor on HEATING side 15 Expansion tank 16 Thermometer 17 Pressure gauge + 3-way valve, pressure gauge housing 18 Thermostat (dual thermostat for superheated water) 19 ISPESL thermometer well 20 Drain valve 21 Fitting for thermometer 22 Fitting for pressure gauge 23 External sensor - 6 -

SKID-TYPE SUBSTATION FOR HEATING AND DOMESTIC HOT-WATER PRODUCTION (with heat exchangers in parallel configuration) This type of substation is suitable for high and medium capacity systems, supplied by superheated water or hot water, for heating and production of domestic hot water. This type of substation is recommended for systems requiring separate and independent management of the heating and domestic hot water circuits. These skid-type substations can be equipped with the SIEMENS RVD (or similar) controller or with the TECHNO SYSTEM TSRE 010 temperature-control system. With this type of substation, users can: directly set the heating set-point and the DHW set-point using easy-access dedicated pushbuttons. (TSRE 010) manage heating and DHW production independently, with separate onboard timers and weekly programs. manage heating by external thermostat/timer-thermostat or on the basis of a weekly schedule programmed in the controller (on/off settings at half-hour intervals). (TSRE 010) set SUMMER or WINTER parameters (DHW only activated in SUMMER mode, DHW and heating activated in WINTER mode). manage heating temperature by the fixed-point or climate-curve method. set the set-points for heating, DHW, and recirculation (if applicable) independently. with the special Economy function, give precedence to DHW over HEATING. (TSRE 010) lock the heating-side set-point for systems serving floor panels. (TSRE 010) set an ANTI-SCUFF cycle for the HEATING side pump (if installed) when system is in SUMMER mode. set an ANTIFREEZE cycle with minimum threshold. maintain temperature in the primary circuit via hydraulic bypass (with ball valve) or managed by the regulator (with times, intervals, and quantities set via the onboard calendar). (TSRE 010) connect a safety thermostat on the heating side (for floor-panel systems) featuring cut-in signal (by acoustic alarm and display message. connect a safety thermostat on the DHW side (for protection against scalding) featuring cut-in signal (by acoustic alarm and display message). signal sensor malfunction (by acoustic alarm and display message. (TSRE 010) signal excessive pressure in the heating circuit by acoustic alarm and display message and signal low water level in the heating circuit (and shutdown of the heating side pump, if applicable) by acoustic alarm and display message). (TSRE 010) reset the values to factory defaults. integrate into other systems with accumulators, traditional boilers, and solar panels. Additionally, this type of substation is prepared for installing devices for: managing recirculation via PID with set-point independent of DHW. managing an ANTI-LEGIONELLA thermal disinfection cycle via onboard calendar (the system must comprise recirculation). limiting the flow rate on the DHS side. limiting the return temperature on the DHS side, with sensor malfunction signal (by acoustic alarm and display message). remote reading of the thermal energy meter. remote control. managing a GSM or PSTN modem connection, which permits sending SMSs or e-mails for notifying alarms or malfunctions. Note: each substation is dimensioned on the basis of the pressure on the two circuits, the thermal head, and/or the heating capacity requested by the customer. For this reason, the overall dimensions of the substations are subject to change, case by case. - 7 -

Hydraulic Diagram Heating send Heating return Hot tap water outlet Cold water inlet Suggested diagram for district heating units working with hot water For district heating units working with superheated water Techno System suggests using a single substation and an additional TS Module for tap water production (see diagrams at p. 17), in order to avoid encrustation problems. COMPONENTS OPTIONALS 1 Plate heat exchanger for HEATING ON/OFF VALVE SET 2 Plate heat exchanger for DHW 25 On/off butterfly valve, HEATING side 3 Servo-controlled valve for HEATING 26 On/off butterfly valve, DHW side 4 Servo-controlled valve for DHW 5 Servomotor for HEATING MISCELLANEOUS 6 Servomotor for DHW 27 Filter, HEATING side 7 Thermal energy meter 28 Filter, DHW side 8 Controller 9 Electrical panel 10 On/off ball valve on PRIMARY side 11 PRIMARY side filter 12 Safety valve 13 Temperature sensor on PRIMARY side 14 Temperature sensor on HEATING side 15 Expansion tank 16 Thermometer 17 Pressure gauge + 3-way valve, pressure gauge housing 18 Thermostat (dual thermostat for superheated water) 19 ISPESL thermometer well 20 Drain valve 21 Fitting for thermometer 22 Fitting for pressure gauge 23 External sensor 24 Temperature sensor on DHW side - 8 -

WALL-MOUNTED DISTRICT HEATING SUBSTATIONS Technical Features Maximum operating pressure DHS network 16 bar (optional PN25) Maximum operating pressure Heating side 2.7 bar Maximum operating pressure DHW side 6 bar (where applicable) Maximum differential pressure on primary side 12 bar (for some models optional 3.5 bar) Minimum differential pressure on primary side close to substation 2 bar Maximum pressure drop on primary side 1bar Test pressure (differential) 1.43 times design pressure. Minimum guaranteed residual head on Heating side 2.5 m.c.a. Protection Class IP54 Electrical supply voltage 230 V Electrical supply frequency 50 Hz The district heating substation is a fully pre-assembled, pre-cabled unit for heat transmission, featuring high yield and maximum operating safety. The structure consists of a zinc-plated frame covered with protective jackets in painted sheet metal which define the overall dimensions of the substation and houses: o Braze welded plate heat exchangers o Safety accessories: Safety valves, ISPESL certified (PED) Expansion tank o Monitoring accessories: Pressure gauges Thermometers High-sensitivity immersion sensors o Protection accessories: Safety thermostats Safety dual thermostat for superheated water and single thermometer for hot water o Control accessories: Two-way seated poppet valves Electrical servo control for the above-mentioned valves o Automatic control accessories: Thermal regulation station for monitoring temperatures at various points and programming and defining parameters for the physical and electrical values to be managed. o Main electrical control panel The wall-mounted district heating substations are available in two installation versions: wall-hung recessed The wall-mounted district heating substations are available: for heating only for heating and DHW production On request, the wall-mounted district heating substations can be supplied fully insulated, with a shell installed inside the frame. - 9 -

WALL-MOUNTED SUBSTATION FOR HEATING USE ONLY This type of substation is suitable for small capacity systems supplied by hot water or superheated water. It is designed for heating use only (radiators, fan coils, floor panels, etc.) when production of domestic hot water is not required. This type of substation is equipped with the TECHNO SYSTEM TSRE 010 temperature-control system. With this type of substation, users can: directly set the heating set-point using easy-access dedicated pushbuttons. read the heating delivery temperatures directly on the controller display. manage heating independently, with separate onboard timers and weekly programs. manage heating by external thermostat/timer-thermostat or on the basis of a weekly schedule programmed in the controller (on/off settings at half-hour intervals). set SUMMER or WINTER parameters (heating deactivated in SUMMER mode). manage heating temperature by the fixed-point or climate-curve method. lock the heating-side set-point for systems serving floor panels. set an ANTI-SCUFF cycle for the HEATING side pump (if installed) when system is in SUMMER mode. set an ANTIFREEZE cycle with minimum threshold. maintain temperature in the primary circuit managed by the regulator (with times, intervals, and quantities set via the onboard calendar) or on request with by-pass through the ball valve. connect a safety thermostat on the heating side (for floor-panel systems) featuring cut-in signal (by acoustic alarm and display message). signal sensor malfunction (by acoustic alarm and display message). (TSRE 010) signal excessive pressure in the heating circuit by acoustic alarm and display message and signal low water level in the heating circuit (and shutdown of the heating side pump, if applicable) by acoustic alarm and display message. reset the values to factory defaults. integrate into other systems with accumulators, traditional boilers, and solar panels. Additionally, this type of substation is prepared for installing devices for: limiting the flow rate on the DHS side. limiting the return temperature on the DHS side, with sensor malfunction signal (by acoustic alarm and display message). remote reading of the thermal energy meter. remote control. managing a GSM or PSTN modem connection, which permits sending SMSs or e-mails for notifying alarms or malfunctions. Capacities and Dimensions Model Heating Capacity (kw) Overall dimensions (mm) Length x Height x Width Connections on Side Connections on Heating Side Empty Weight (kg) R34T 34 580x685x220 G 1 G 3/4 20 R50T 50 580x685x220 G 1 G 1 28 R75T 75 760x765x275 G 11/4 G 11/4 60 R100T 100 760x765x275 G 11/4 G 11/4 61 R116T 116 760x765x275 G 11/4 G 11/4 62 NOTE: the dimensions reported are purely indicative and refer to wall-hung substations constructed in accordance with TECHNO SYSTEM standards (dimensions may differ in the case of the recessed version). - 10 -

Hydraulic Diagram COMPONENTS OPTIONALS 1 Plate heat exchanger for HEATING ON/OFF VALVE SET 3 Servo-controlled valve for HEATING 21 On/off ball valve on PRIMARY side 5 Servomotor for HEATING 22 On/off ball valve on HEATING side 7 Thermal energy meter TEMPERATURE LIMITER SET PRIMARY SIDE 8 Controller 24 Limit temperature sensor for PRIMARY side 9 Electrical panel DELIVERY LIMITER SET PRIMARY SIDE 11 Filter 25 Thermal energy meter with pulse counter card 12 Safety valve TEMPERATURE SAFETY SET HEATING SIDE FOR FLOOR 13 Temperature sensor on HEATING side PANEL SYSTEM 15 Expansion tank 26 Thermostat on HEATING side 16 Vent ball valve on PRIMARY side SUPERHEATED WATER 18 Vent valve on HEATING side 27 Dual thermostat 28 ISPESL thermometer well PRESSURE SAFETY SET HEATING SIDE 31 Maximum/Minimum pressure switch PUMP SET 32 Minimum pressure switch 33 Circulation pump MISCELLANEOUS 34 External sensor 35 Bypass ball valve - 11 -

WALL-MOUNTED SUBSTATION FOR HEATING AND DOMESTIC HOT-WATER PRODUCTION (with heat exchangers in parallel configuration) This type of substation is suitable for small capacity systems, supplied by hot water (or superheated) for heating (via radiators, fan coils, floor panels, etc.) and production of domestic hot water. This type of substation is recommended for systems requiring separate and independent management of the heating and domestic hot water circuits (the system may also be configured to give precedence to production of hot water over heating). This type of substation is equipped with the TECHNO SYSTEM TSRE 010 temperature-control system. With this type of substation, users can: directly set the heating set-point and the DHW set-point using easy-access dedicated pushbuttons. read the heating delivery, DHW, and recirculation (if applicable) temperatures directly on the controller display. manage heating and DHW production independently, with separate onboard timers and weekly programs. manage heating by external thermostat/timer-thermostat or on the basis of a weekly schedule programmed in the controller (on/off settings at half-hour intervals. set SUMMER or WINTER parameters (DHW only activated in SUMMER mode, DHW and heating activated in WINTER mode). manage heating temperature by the fixed-point or climate-curve method. set the set-points for heating, DHW, and recirculation (if applicable) independently. with the special Economy function, give precedence to DHW over HEATING. lock the heating-side set-point for systems serving floor panels. set an ANTI-SCUFF cycle for the HEATING side pump (if installed) when system is in SUMMER mode. set an ANTIFREEZE cycle with minimum threshold. maintain temperature in the primary circuit via bypass (with ball valve) or managed by the regulator (with times, intervals, and quantities set via the onboard calendar). connect a safety thermostat on the heating side (for floor-panel systems) featuring cut-in signal (by acoustic alarm and display message). connect a safety thermostat on the DHW side (for protection against scalding) featuring cut-in signal (by acoustic alarm and display message). signal sensor malfunction (by acoustic alarm and display message. signal excessive pressure in the heating circuit by acoustic alarm and display message and signal low water level in the heating circuit (and shutdown of the heating side pump, if applicable) by acoustic alarm and display message). reset the values to factory defaults. integrate into other systems with accumulators, traditional boilers, and solar panels. Additionally, this type of substation is prepared for installing devices for: managing recirculation via PID with set-point independent of DHW. managing an ANTI-LEGIONELLA thermal disinfection cycle via onboard calendar (the system must comprise recirculation). limiting the flow rate on the DHS side. limiting the return temperature on the DHS side, with sensor malfunction signal (by acoustic alarm and display message). remote reading of the thermal energy meter. remote control. managing a GSM or PSTN modem connection, which permits sending SMSs or e-mails for notifying alarms or malfunctions. Capacities and Dimensions Model Heating Capacity (kw) Overall dimensions (mm) Length x Height x Width Connections on Side Connections on Heating Side Connections on DHW Side Empty Weight (kg) RI34T.P 34+34 580x685x220 G 1 G 3/4 G 1/2 30 RI50T.P 50+34 760x765x275 G 11/4 G 1 G 1/2 45 NOTE: the dimensions reported are purely indicative and refer to wall-hung substations constructed in accordance with TECHNO SYSTEM standards (dimensions may differ in the case of the recessed version). - 12 -

Hydraulic Diagram Recirculation Cold Water Inlet COMPONENTS OPTIONALS 1 Plate heat exchanger for HEATING ON/OFF VALVE SET 2 Plate heat exchanger for DHW 21 On/off ball valve on PRIMARY side 3 Servo-controlled valve for HEATING 22 On/off ball valve on HEATING side 4 Servo-controlled valve for DHW 23 On/off ball valve on DHW side 5 Servomotor for HEATING TEMPERATURE LIMITER SET PRIMARY SIDE 6 Servomotor for DHW 24 Limit temperature sensor for PRIMARY side 7 Thermal energy meter DELIVERY LIMITER SET PRIMARY SIDE 8 Controller 25 Thermal energy meter with pulse counter card 9 Electrical panel TEMPERATURE SAFETY SET HEATING SIDE FOR FLOOR 10 Flow switch PANEL SYSTEM 11 Filter 26 Thermostat on HEATING side 12 Safety valve TEMPERATURE SAFETY SET DHW SIDE (ANTI-SCALDING) 13 Temperature sensor on HEATING side 27 Thermostat on DHW side 14 Temperature sensor on DHW side RECIRCULATION SET 15 Expansion tank 28 Temperature sensor on RECIRCULATION side 16 Vent ball valve on PRIMARY side 29 Safety valve on DHW side 17 Bypass ball valve 30 Vent valve on DHW side 18 Vent valve on HEATING side 31 On/off ball valve on RECIRCULATION side 19 Filling ball valve PRESSURE SAFETY SET HEATING SIDE 20 Pressure gauge 32 Maximum/Minimum pressure switch 33 Minimum pressure switch MISCELLANEOUS 34 Circulation pump 35 External sensor - 13 -

WALL-MOUNTED SUBSTATION FOR HEATING AND DOMESTIC HOT WATER PRODUCTION (with heat exchangers in series configuration) This type of substation is suitable for small capacity systems supplied by superheated water (or by hot water at sufficiently high temperature). It is designed for heating (via radiators, fan coils, floor panels, etc.) and production of domestic hot water. This type of substation is recommended for systems in which independent management of the heating and domestic hot water circuits is not required (hot water production always takes precedence over heating). This type of substation is equipped with the TECHNO SYSTEM TSRE 010 temperature-control system. With this type of substation, users can: directly set the heating set-point using easy-access dedicated pushbuttons. read the heating delivery, DHW, and recirculation (if applicable) temperatures directly on the controller display. manage heating and DHW production independently, with separate onboard timers and weekly programs. manage heating by external thermostat/timer-thermostat or on the basis of a weekly schedule programmed in the controller (on/off settings at half-hour intervals. set SUMMER or WINTER parameters (DHW only activated in SUMMER mode, DHW and heating activated in WINTER mode). manage heating temperature by the fixed-point or climate-curve method. set the set-points for heating, DHW, and recirculation (if applicable) independently. lock the heating-side set-point for systems serving floor panels. set an ANTI-SCUFF cycle for the HEATING side pump (if installed) when system is in SUMMER mode. set an ANTIFREEZE cycle with minimum threshold. maintain temperature in the primary circuit managed by the regulator (with times, intervals, and quantities set via the onboard calendar) or on request with by-pass through the ball valve. connect a safety thermostat on the heating side (for floor-panel systems) featuring cut-in signal (by acoustic alarm and display message). connect a safety thermostat on the DHW side (for protection against scalding) featuring cut-in signal (by acoustic alarm and display message. signal sensor malfunction (by acoustic alarm and display message. signal excessive pressure in the heating circuit by acoustic alarm and display message and signal low water level in the heating circuit (and shutdown of the heating side pump, if applicable) by acoustic alarm and display message). reset the values to factory defaults. integrate into other systems with accumulators, traditional boilers, and solar panels. Additionally, this type of substation is prepared for installing devices for: managing recirculation via PID with set-point independent of DHW. managing an ANTI-LEGIONELLA thermal disinfection cycle via onboard calendar (the system must comprise recirculation). limiting the flow rate on the DHS side. limiting the return temperature on the DHS side, with sensor malfunction signal (by acoustic alarm and display message). remote reading of the thermal energy meter. managing remote control. managing a GSM or PSTN modem connection, which permits sending SMSs or e-mails for notifying alarms or malfunctions. Capacities and Dimensions Model Heating Capacity Overall dimensions (mm) Length x Height x Width Connections on Side Connections on Heating Side Connections on DHW Side Empty Weight (kg) (kw) RI34T.S 34 580x685x220 G 3/4 G 3/4 G 1/2 32 NOTE: the dimensions reported are purely indicative and refer to wall-hung substations constructed in accordance with TECHNO SYSTEM standards (dimensions may differ in the case of the recessed version). - 14 -

Hydraulic Diagram Recirculation Cold Water Inlet COMPONENTS OPTIONALS 1 Interface plate heat exchanger ON/OFF VALVE SET 2 Plate heat exchanger for DHW 21 On/off ball valve on PRIMARY side 3 Servo-controlled valve 22 On/off ball valve on HEATING side 4 Servomotor 23 On/off ball valve on DHW side 5 3-way valve TEMPERATURE LIMITER SET, PRIMARY SIDE 6 Circulation pump 24 Limit temperature sensor for PRIMARY side 7 Thermal energy meter DELIVERY LIMITER SET, PRIMARY SIDE 8 Controller 25 Thermal energy meter with pulse counter card 9 Electrical panel TEMPERATURE SAFETY SET HEATING SIDE FOR FLOOR 10 Flow switch PANEL SYSTEM 11 Filter 26 Thermostat on HEATING side 12 Safety valve TEMPERATURE SAFETY SET DHW SIDE (ANTI-SCALDING) 13 Temperature sensor on HEATING side 27 Thermostat on DHW side 14 Temperature sensor on DHW side RECIRCULATION SET 15 Expansion tank 28 Temperature sensor on RECIRCULATION side 16 Vent ball valve on PRIMARY side 29 Safety valve on DHW side 17 Dual thermostat 30 On/off valve on DHW side 18 Vent valve on HEATING side PRESSURE SAFETY SET HEATING SIDE 19 Filling ball valve 32 Maximum/Minimum pressure switch 20 Pressure gauge MISCELLANEOUS 31 Minimum pressure switch 33 Bypass ball valve 34 External sensor - 15 -

EXAMPLES OF SYSTEM LAYOUTS LEGEND The symbols shown and explained in this section refer to the system layout diagrams reproduced below. Although these diagrams have been modified according to the needs of the designer, they are all highly reliable and thoroughly field-tested. Heat exchanger Ball valve ISPESL thermometer well Radiator Butterfly valve Expansion tank Hot domestic water outlet Safety valve Electrical panel Accumulation tank Thermal energy meter Logic unit (not supplied) Boiler Flow switch Non-return valve Solar panel External sensor A Water-softening unit Pool Room thermostat Pressure reducer 2-way valve Temperature-control thermostat Bypass valve 3-way valve Maximum pressure switch Water treatment 3-way mixing valve Minimum pressure switch Pool filter Circulation pump Thermometer Pump with pre-filter Y filter Pressure gauge Hydraulic separator Sensor Vent valve - 16 -

DIAGRAM No. 1 Skid-type substation for heating use only with integrated TS module for instantaneous domestic hot water production Primario Primario DHS Substation A Recirculation Cold Water Inlet TS MDI Module DIAGRAM No. 2 Skid-type substation for heating use only with integrated TS Module for use with accumulation tank for domestic hot water production DHS Substation TS MDA Module Cold Water Inlet DIAGRAM No. 3 Skid-type substation for heating use only with integrated TS Module for pool heating A DHS Substation TS MDP Module - 17 -

DIAGRAM No. 4 Skid-type or wall-mounted substation for heating use only with integrated boiler for domestic hot water production DHS Substation Cold Water Inlet A Warning: in case of system installation employing wall-mounted substation, the heating side pump should not be supplied (or is supplied, should not be connected to the controller on the substation but, instead, to a logic unit external to the substation). DIAGRAM No. 5 Wall-mounted substation with heat exchangers in parallel configuration and integrated accumulation tank DHS Substation Cold Water Inlet A DIAGRAM No. 6 Wall-mounted substation with heat exchangers in parallel configuration and integrated accumulators and solar panels DHS Substation - 18 - Cold Water Inlet A

DIAGRAM No. 7 Wall-mounted substation with parallel exchangers and hydraulic separator on heating circuit DHS Substation A Cold Water Inlet - 19 -