LeakFilm. Protecting your high-tech assets with innovative, user-friendly technology for liquid leak detection

Similar documents
Technical Manual. LeakFilm Sensor. Film Type Liquid Leak Detection Sensor

Technical Manual. LeakFilm Pro. Single Channel Conductive and Chemical Liquid Leak Detection Controller with Leak Location Detection

Technical Manual. LeakFilm 5. 5 Channel Conductive Liquid Leak Detection Controller

Danfoss gas detection units

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Dräger Flame 2100 Flame Detection

Danfoss gas detection units

Touchpoint Plus. A whole new control experience

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Multi-Gas-Controller MGC2

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Minimize Leaks Maximize Asset Protection

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz.

Gas Controller Module GC-06

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Dräger Flame 2500 Flame Detection

Recalibrate the way you look at gas detection

MODEL DESCRIPTION PAGE

SPM Flex Chemcassette Tape-Based Gas Detector

Nitrogen Dioxide Stand-Alone Detector - Analog, ModBus

User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Zareba Sensepoint Pro

Digital 7 Square Plate Magnetic Stirrer

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

O3TH. Ozone Detector c/w Indicator for Temperature/Humidity. Automatikprodukter. Features. Technical Data. Description. Ordering Codes. Dec.

IGD.CO.UK

SAM-MAX Refrigerant Monitors

Danfoss gas detection unit Type GD Heavy Duty

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Pioneer-R16 Gas Monitor Operator s Manual

PolyGard 2-channel Gas Controller MGC-03

Gas detecting sensor Types GDA, GDC, GDHC, GDHF, GDH

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

Temperature Controllers

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

S5000 Gas Monitor. GMS5000.com

EC FX NH3. A new and improved approach to ammonia gas detection

AUTOMOTIVE REFRIGERANT ANALYZER OPERATION MANUAL. Analyzer Part Number: 68941

safe and your operations compliant

HALOGUARD TM II MULTI-GAS MULTI-SENSOR MONITOR INSTRUCTION MANUAL

DASPOS A/S Gammel Klausdalsbrovej Herlev Denmark Tel.: website: DASPOS USA, Inc NE 116th Street, PMB

SMART THERMOSTAT WITH HOT WATER CONTROL

Two-Channel Gas Controller

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Life insurance for your electronics

Omniguard 4: Features

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

Liquid Helium Level Instruments

incontrol Systems Inc. Flame and Gas Detection

BlueSpin Magnetic Hotplate Stirrer

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Gas Detection. Touchpoint Plus. A whole new control experience

USER MANUAL FOR OPERATING SYSTEM

MSA Flame and Gas Detection. [ for the Oil, Gas and Petrochemical Industries ]

Model OEM-2 INSTRUCTIONS FOR USE

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Carbon Monoxide Transmitter

EasyTronic III MANUAL SERVICE

Flopurge TS. Operation Manual

Model 3300 Technical Support and Installation Manual

CALIDUS tm the Modular micro Gas Chromatograph

Environmental simulation chamber for complex alternating climate profiles

VA301C CONTROLLER WITH BACnet OPTION

Zareba Metro Gas Detector

Flame Detector. Model: ZT-30P. User Guide. Document Ref: GLT Zeta Alarms Limited Morfa Road, Swansea, SA1 2EN, United Kingdom

Touchpoint Pro Flexible Gas Control System

2-zone application 2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX FEATURES APPLICATION MANUAL

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

SCAN200E USER S MANUAL

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Chillgard Refrigerant Monitor

SimpleVIS Viscometer Reference Guide P

Ammonia Leak Detector Manual

Product Training Module: Inertial Measurement Unit 6-D Motion Variant 6DF Series. Copyright 2013 Honeywell International Inc. All rights reserved.

Freeze Dry Systems and Accessories

Dräger Flame 2500 (IR3) Flame Detection

Freeze Dry Systems and Accessories

Octalarm-T: the latest in future-proof industrial alarm diallers

System 57. An advanced World of intelligent gas detection system management

IT S WHAT S INSIDE THAT

Sensepoint XCD RTD. Remotely monitor toxic gases in Class 1, Div 2 areas while reducing the maintenance, training and overall cost of gas monitoring

Your trusted partner in providing the best fixed Gas Detection Sales and Service in Western Canada

AirGard. Air Flow Monitors

DIESEL Engine Fire Pump Controllers Features

The SharpEye 40/40I (IR3) Flame Detection

Nardalert S3 TM Non-Ionizing Radiation Monitor

Dräger Flame 2350 (UV&IR) Flame Detection

Toxic Gas Detection. Model F12. Toxic Gas Detection

T6865 Series Large LCD Digital Thermostat 24 VAC 2-pipe fan coil control

Transcription:

Protecting your high-tech assets with innovative, user-friendly technology for liquid leak detection

The most reliable, durable, cost-effective solution Unlike some other forms of liquid leak detection, LeakFilm stands up to the challenges of your facility: Durable and flexible. You can walk on it, roll carts over it, wrap it around pipes, and subject it to varying levels of temperature, humidity and dust with no false alarms. Fast response. When LeakFilm senses a liquid leak, the LeakFilm controller immediately notifies you so you can address the situation without delay. Additionally, certain LeakFilm configurations can measure the distance from the leak point to the controller giving you increased visibility to the location of the leak. Long life. Unlike sensing cables, which may need to be replaced after exposure to some liquids, LeakFilm withstands water and conductive liquids*. In the event of exposure, just wipe off the ribbon and reuse it no replacement costs. Easy to install and maintain. Use the adhesive backing and supplied connectors to install LeakFilm wherever you need it. And if it tears, simply cut and reconnect the film no need to replace the whole section. You can even write on the ribbon if needed. *NOTE: Conductive and Conductive_D are reusable. Chemical and hydrocarbon LeakFilm detection must be replaced at the spot of the leak after contact. What happens if a leak causes liquid to come into contact with the sensitive equipment in your semiconductor facility? Would you know about it? Would you have time to correct the problem, preventing damage and costly downtime? LeakFilm uses innovative technology to alert you to leaks of water, chemicals and hydrocarbons so you can take immediate action to protect your assets, manage costs and ensure constant uptime. In addition to protecting your equipment, LeakFilm helps you protect your people by monitoring for liquid leaks that cause life-safety hazards such as slips, falls and inhalation of dangerous vapors. Flexible applications for liquid leak detection LeakFilm is a liquid leak detection system that combines unique liquid-sensing film which can be networked into broader building alarm systems. When liquid comes into contact with the LeakFilm, your controller will alarm within a few seconds, allowing you address the situation without delay. LeakFilm sensors can detect water, conductive liquids, strong acids, and hydrocarbons. The sensor can easily be installed with the adhesive tape backing, and in the event a sensor needs to be replaced LeakFilm can be easily spliced using the available connectors allowing easy and cost efficient replacement of LeakFilm sensors. Thanks to its flexible form and adhesive backing, our patented LeakFilm is easy to install in numerous applications on floors, walls, pipes, equipment and other areas that could be susceptible to leaks of hazardous chemicals. Use LeakFilm to monitor for liquid leaks around: Wet benches Photolithography equipment Chemical storage rooms Gas cabinets Boilers Distribution boxes And if your facility has a computer room or communications room, use LeakFilm to monitor for one of the biggest threats water. Leaks can come from such sources as air conditioning systems, concealed piping and plumbing in adjacent rooms.

System Components LeakFilm Sensor LeakFilm Conductive Water and conductive liquids leak detection film sensor Water and conductive liquids leak detection film sensor with leak location detection Strong acid liquids leak detection film sensor with leak location detection LeakFilm Hydrocarbon Hydrocarbon liquids leak detection film sensor LeakFilm Controller LeakFilm Mini One channel mini conductive liquid leak detection controller with broken sensor detection LeakFilm 5 Five channels conductive liquid leak detection controller with broken sensor detection LeakFilm Pro One channel conductive and chemical liquid leak detection controller with leak location detection LeakFilm HC One channel hydrocarbon liquid leak detection controller with broken sensor detection LeakFilm MC Master liquid leak detection controller LeakFilm Connector Connects controller and sensor Connect the sensor and sensor Connect the sensor and sensor End Connector 4 Lines End connector to LeakFilm Conductive_D, LeakFilm Chemical and LeakFilm Hydrocarbon film sensor End Connector 2 Lines End connector to LeakFilm Conductive film sensor LeakFilm System How LeakFilm Works LeakFilm is a one-inch wide ribbon with tiny holes on top and a conductive solution inside. When liquid passes through the holes and touches the circuit film s wires, a change in the electrical resistivity will be detected by the LeakFilm controller s algorithm, and will signal a leak detection so you can protect your assets and prevent downtime. The perfect complement to your toxic gas monitoring system Monitoring for liquid leaks is another important way to prevent costly downtime and ensure life safety, and LeakFilm delivers the best combination of accuracy, flexibility and ease of use.

Specifications Specifications - Sensor Product Name LeakFilm Conductive LeakFilm Hydrocarbon Target Water and conductive liquid Water and conductive liquid Sulfuric acid, Hydrofluoric acid, Nitric acid Liquid organic solvent Material PET PET PET PET Circuit Thickness 5 to 10 μm 5 to 10 μm 5 to 10 μm 5 to 10 μm Film Thickness Connector Material PBT PBT PBT PBT Storage Temperature -10 to 80 C -10 to 80 C -10 to 80 C -10 to 60 C Operating Temperature -10 to 55 C -10 to 55 C -10 to 55 C -10 to 55 C Operating Humidity 5 to 85 %RH 5 to 85 %RH 5 to 85 %RH 5 to 85 %RH Weight Under 20 g/m Under 20 g/m Under 20 g/m Under 20 g/m Response Time for Leakage* Under 4 sec Under 4 sec Under 10 sec Toluene: under 1min Benzene: under 1min Gasoline: under 1min Diesel: under 5min Kerosene: under 5min Chloroform: under 1min Response Time for Open Under 4 sec Under 10 sec Under 10 sec Under 17sec Leak Location Accuracy N/A ±1 m (above 10 m) ±1 m (above 10 m) N/A Length 0.5 m to 50 m 3 m to 200 m 3 m to 200 m 0.5 m to 50 m Specifications - Controller Product Name LeakFilm Mini LeakFilm 5 LeakFilm Pro LeakFilm HC LeakFilm MC Applicable Sensor LeakFilm Conductive LeakFilm Conductive LeakFilm Hydrocarbon N/A Applicable Controller N/A N/A N/A N/A LeakFilm Pro, LeakFilm 5, LeakFilm HC Display N/A N/A 8 X 2 Character LCD / LED 8 X 2 Character LCD / LED 20 X 4 Character LCD / LED Power 20 to 36 VDC 20 to 36 VDC 20 to 36 VDC 20 to 36 VDC 100 to 240VAC 50/60 Hz Power Consumption Max 1 Watt Max 4 Watt Max 4 Watt Max 4 Watt Max 10 Watt LED Indication Sound Level Over 80dB @ 10 cm Over 80dB @ 10 cm Over 80dB @ 10 cm Over 80dB @ 10 cm Over 80dB @ 10 cm Output Relay (NO) 30 VDC 5A, or 250VAC 5A Relay (NO) 30 VDC 5A, or 250VAC 5A * Typical response time at 20 C(68 F). ** To use the digital communication, please contact a Honeywell Analytics Representative for further details. Relay (NC, NO) 24VDC 2A or 120 VAC 1A Relay (NC, NO) 24VDC 2A or 120 VAC 1A Relay (NC, NO) 24VDC 2A or 120 VAC 1A LEAK Relay (NC, NO) BROKEN Relay (NC, NO) Com Err Relay (NC, NO) Communication N/A RS485 (**Modbus ) RS485 (**Modbus ) RS485 (**Modbus ) RS485 (**Modbus ) Communication Function N/A (Status Transmission) Leak Location Data Recording N/A N/A 9 event - year / month / day / hour / min / Leak location 9 event - year / month / day / hour / min / Leak or Broken message Leak Location Communication Error and Clearance 999 event - Detector ID / Leak and Leak location or Broken or Communication error/ year - month - day hour : min : sec / Storage Temperature -10 to 65 C -10 to 65 C -10 to 65 C -10 to 65 C -10 to 65 C Operating Temperature -10 to 55 C -10 to 55 C -10 to 55 C -10 to 55 C -10 to 55 C Operating Humidity 5 to 85 %RH 5 to 85 %RH 5 to 85 %RH 5 to 85 %RH 5 to 85 %RH Leak Location Accuracy N/A N/A ±1 m (above 10 meter) N/A N/A ID Setting N/A 1 to 15 1 to 200 1 to 200 1 to 32 IP Rating IP20 IP20 IP20 IP20 IP43 EMC Directive 2004/108/EC EN61000-6-4/A1:2011, EN61000-6-2:2005, EN61000-3-2/A2:2009, EN61000-3-3:2008 Electrical Safety 1) Low Voltage Directive 2006/95/EC:EN 61010-1:2010 2) US:UL 61010-1 3rd Edition 3) Canada: CAN/CSA-C22.2 No.61010-1 3rd Edition

Order Information and Configuration Rules Order Information 1. LeakFilm Controller HLFC1MNN LeakFilm Mini 1 Channel Mini Conductive Controller with Broken Sensor Detection HLFC5CRN LeakFilm 5 5 Channel Conductive Controller with Broken Sensor Detection HLFC1HRN LeakFilm HC 1 Channel Hydrocarbon Controller with Broken Sensor Detection HLFC1DRD LeakFilm Pro 1 Channel Conductive & Chemical Controller with Leak Location Detection HLFCMSRD LeakFilm MC Master Controller with RS485 2. LeakFilm Sensor HLFSSCNN-100 HLFSSCNN-050 HLFSSCNN-001 HLFSSCND-100 HLFSSCND-050 HLFSSCND-001 HLFSSAND-100 HLFSSAND-050 HLFSSAND-001 HLFSSHNN-100 HLFSSHNN-050 HLFSSHNN-020 HLFSSHNN-001 LeakFilm Conductive LeakFilm Hydrocarbon 100 m Conductive Sensor 50 m Conductive Sensor Custom Length Conductive Sensor (per meter) 100 m Conductive Sensor with Leak Location Detection 50 m Conductive Sensor with Leak Location Detection Custom Length Conductive Sensor with Leak Location Detection (per meter) 100 m Chemical Sensor with Leak Location Detection 50 m Chemical Sensor with Leak Location Detection Custom Length Chemical Sensor with Leak Location Detection (per meter) 100 m Hydrocarbon Sensor 50 m Hydrocarbon Sensor 20 m Hydrocarbon Sensor Custom Length Hydrocarbon Sensor (per meter) 3. LeakFilm Connector HLFNCSND-005 with 5 meters Lead Wire HLFNCJND-000 with 15 cm Lead Wire HLFNCJND-001 with 1 meter Lead Wire HLFNCLND-000 HLFNCEND-000 End Connector 4 Lines End Connector 4 Lines with Leak Location Detection HLFNCENN-000 End Connector 2 Lines End Connector 2 Lines Configuration Rules Master Controller LeakFilm MC Leak Film MC Leak Film MC Controller LeakFilm Pro LeakFilm HC LeakFilm 5 LeakFilm Mini Sensor LeakFilm Hydrocarbon LeakFilm Conductive LeakFilm Conductive End Connector End Connector 4 Lines End Connector 4 Lines End Connector 2 Lines End Connector 2 Lines Other Connectors