Speedlock AMC Connectors...KA1. Armored Cable Connectors...KB1-KB5 Metal Clad Cable Connectors...KB1-KB5 Flexible Metal Conduit Connectors...

Similar documents
Cable Connectors For Armored Cable, Flexible Metal Conduit, Interlocked AC-38 Cables, NM and SE Cable

AFC Cable Systems: the Cable Industry Leader for Over 80 Years

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

NELSON HEAT TRACING SYSTEMS

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

The Star Teck Extreme STE/STEX Series Connectors

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

NELSON HEAT TRACING SYSTEMS INSTALLATION

NELSON HEAT TRACING SYSTEMS

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

ELECTRICAL SUPPLIES NATIONAL REFRIGERATION PRODUCTS WIRE NUTS HEAT SHRINK TUBING CABLE STAPLES CABLE MARKERS

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Helically wound resistance wire coil made

SECTION (16140) - WIRING DEVICES

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Installation Instructions

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

SECTION BASIC ELECTRICAL MATERIALS AND METHODS. A. This Section includes basic electrical materials and methods including:

Vibratone Horns. Models 350 and 450

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

B C D. Strip Heaters. Channel Strip Heaters Ceramic Insulated. To order, call or shop online at omega.com SM

NELSON HEAT TRACING SYSTEMS

North American Cable Glands

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

NELSON HEAT TRACING SYSTEMS

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Circulation Heaters Selection Guidelines

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

S1L Series: Metal Bottom

FRP HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL FRP.IOM.R1

Installation Instructions

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS

NELSON HEAT TRACING SYSTEMS ALT-BC STANDARD POWER CONNECTION KIT

Heavy Industrial/Marine MaxGard

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

C Electrical Connection Kit

Electricity Unit Notes. Agriculture Mechanics I

Installation Instructions

BAND HEATERS TYPICAL APPLICATIONS: SPECIAL OPTIONAL FEATURES: Plastic Injection Molding. Two piece construction. Plastic, Food, or Candy Extruders

NELSON HEAT TRACING SYSTEMS

SECTION ELECTRICAL GENERAL PROVISIONS

Smart Products. Ingenious Solutions.

Chapter 1 General... 5

Circulation Heaters Selection Guidelines

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

Star Teck. Teck and Tray Cable Fittings. Table of Contents

MaxGard. Interconnection Systems. Durability. Performance. Safety

Marathon Special Products

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

ACCESSORIES GUIDE. RobroyEnclosures.com. Market-Leading Non-Metallic Enclosure Brands

EJB Custom-Built Control Panels

NELSON HEAT TRACING SYSTEMS

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Mineral Insulated Band Heater

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

Second Revision No. 601 NFPA [ Section No [Excluding

ULTRA-SAFE Explosion-proof Duct Heaters

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

CADDY CORPORATION. Utility Distribution Systems

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Cartridge Heaters. Components. Application Guidelines

Tubular Industrial Process

CATALOG OF REPLACEMENT PARTS

temperature Controllers

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Freezer Frost Heave Prevention

DIVISION 16 ELECTRICAL

Top Products - Modified HVAC Catalog

Installation Instructions

Vibratone Horns. Models 350 and 450

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

ChromaStar. Comfort. Infra-Red Radiant Heaters. Description. Portable. Applications. Fixed Overhead. 1.5 to 13.5 kw. 5,118 to 46,062 BTU/Hr

The Next Generation of Greenfield Connectors. Our flex System is Your Solution for Electrical Runs

Installation Instructions

Ozone Generator Systems

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Piggyback Mechanical Float Switch. Piggyback Vertical Mechanical Float Switch. Piggyback Diaphragm Switch. Accessories

CLASSIFICATION COMPARATOR

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

DRYER INSTALLATION INSTRUCTIONS

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

HPNLS-LO. Installation Manual

B. Product Certificates: For each type of meter and gage, from manufacturer.

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters.

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

SERGE BARIL HEAT TRACING SYSTEMS

Electric Dryer Installation Instructions

ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS

Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

All surfaces shall be restored where surface finish damage is evident. Physical material damage will require replacement of part.

Transcription:

SECTION K INDEX Product Description Page Number Speedlock AMC Connectors............................KA Armored Cable Connectors...........................KB-KB5 Metal Clad Cable Connectors.........................KB-KB5 Flexible Metal Conduit Connectors......................KB-KB5 45 Armored Cable Connectors............................KB2 45 Flexible Metal Conduit Connectors......................KB2 0 Armored Cable Connectors............................KB 0 Flexible Metal Conduit Connectors......................KB Aluminum Sheathed Cable Connectors......................KB6 Non Metallic Sheathed Cable Connectors................KB-KB8 0 N. Frontage Road Skokie, Illinois 600

Notes 0 N. Frontage Road Skokie, Illinois 600

KA Speedlock Steel Box Connectors Type AMC To ground and secure MC, AC, and Flexible Metal Conduit to boxes and enclosures. ETP Speedlock Steel Box Connectors KA No locknut required. Single-unit or duplex construction with captive clamp. Connects over 00 sizes of MC, AC and Flexible Metal Conduit with just four fittings. Easy to install. Just tilt, insert and snap down. Single-unit construction eliminates loose component parts. Integral red plastic insulated throat bushing provides maximum protection for wire insulation. Materials/Finish: Steel/Zinc Electroplated UL Listed: E-852 For Steel Box Installations CSA Certified: 2850 AMC-50 Trade Size Catalog Dim. in Inches (inches) Number A B C 2 Single AMC-50 8 2 4 Single AMC-5 5 8 5 2 KO; 4 capacity AMC-505 5 8 5 2 Duplex AMC-52 2 2 AMC-52 UL Standard: 54B CSA Standard: C22.2 No. 8 Exceeds UL specifications for electrical continuity and is suitable as a grounding means under NEC 250.8(5)&(6) and for hazardous locations under NEC 50.4(B), for Class, Div. 2 areas. AMC SELECTION CHART Cable AMC-50 AMC-505 AMC-5 AMC-52** Type 2 KO 2 KO 4 Capacity 4 KO 2 KO Duplex AC Steel 4/2 4/ 4/4 0/4 0/5 0/4 0/5 4/2 4/ 4/4 2/2 2/ 2/4 8/ 8/4 8/ 8/4 2/2 2/ 2/4 0/2 0/ 6/ 6/ HFC Steel 4/2 4/ 4/2 4/ Health Care 2/2 2/ 2/2 2/ Facilities 0/2 0/2 AC Aluminum 4/2 4/ 4/4 0/4 0/4 4/2 4/ 4/4 Interlocked 2/2 2/ 2/4 8/ 8/4 8/ 8/4 2/2 2/ 2/4 MC Steel *4/2 *4/ *4/4 *0/ *0/4 *0/ *0/4 4/2 4/ 4/4 *2/2 *2/ *2/4 *8/2 *8/ *8/2 *8/ 2/2 2/ 2/4 *0/2 *6/2 *6/2 0/2 MC Aluminum 4/2 4/ 4/4 0/ 0/4 0/ 0/4 4/2 4/ 4/4 Interlocked 2/2 2/ 2/4 8/2 8/2 2/2 2/ 2/4 0/2 MC Aluminum 4/ 4/4 *2/2 *2/ 2/4 0/2 0/ MC Aluminum 2/ Flat Flexible Metal Conduit /8 Steel & Alum /2 Steel /2 Steel (Standard and Reduced Wall) *Concrete tight when taped and used with PVC jacketed cable. **Accepts 2 cables of each size listed. 0 N. Frontage Road Skokie, Illinois 600

KA2 Notes KA2 0 N. Frontage Road Skokie, Illinois 600

KB Cable Connectors For Armored Cable & Flexible Metal Conduit KB Type C & Type 24 Straight Squeeze Connectors To ground and secure Armored Cable and Flexible Metal Conduit to boxes and enclosures. Male hub threads - NPS. Available with insulated throat. Furnished with locknuts. Materials/Finish: UL Listed: E-852 C-5 through C-8: UL Listed for armored cable. UL Listed: E-85 C-8, 24-4 through 24-00: UL Listed for flexible metal conduit UL Listed flexible metal conduit fittings are suitable for use in Hazardous Location under NEC 50.4(B), Class I, Div. II, and suitable as a grounding means under NEC 250.8(5)&(6). Type C-5 End Stopped Insulated Throat Dimensions in Inches Trade Size Catalog Catalog Body Thread Max. Flex. (inches) Number Number Length Length Width Opening 8 ( 2 KO) C-5 2 C-8 C-8T 5 4 24-4 24-4T 8 24-00 24-00T 4 24-25 24-25 4 2 24-50 24-50T 8 Type C-8 Type 24-25 Center Stopped 8 2 2 4 2-2 25 2-5 2 2-5 64 2 2-5 8 2 2-5 8 2 5 8 5 8-8 2 24-200 24-200T 2 4 5 2-2 8 2 2 24-250 24-250T 2 5 4 2 45 64-2 6 64 24-00 24-00T 2 5 4 4 5 8 8-2 Type 24-50 Type 24-00 Center Stopped CSA Certified: 5: Armored Cable Type C- Set-Screw Connector To ground and secure Armored Cable to boxes and enclosures. Male hub threads (NPS) Cable stop. UL Listed for armored cable. Furnished with locknuts. Materials/Finish: Malleable Iron/Zinc Plated UL Listed: 852 CSA Certified: 5 Dimensions in Inches Trade Size Catalog Body Thread Max. Flex. (inches) Number Length Length Width Opening 8 ( 2 KO) C-Z 2 2 64-5 8 UL Listed flexible metal conduit fittings are suitable for use in Hazardous Location under NEC 50.4(B) Class I, Div. II, and suitable as a grounding means under NEC 250.8(5)&(6). UL Standard: 54B CSA Standard C22.2 No. 8 NEMA: FB- Type C-Z 0 N. Frontage Road Skokie, Illinois 600

KB2 Cable Connectors For Armored Cable & Flexible Metal Conduit Type AC 45 Angle Squeeze Connectors KB2 To ground and secure Armored Cable and Flexible Metal Conduit to boxes and enclosures. Male hubs - NPS. Provided with center stop. Available with insulated throats. Furnished with locknuts Also suitable for NM and SE cable Type AC-8 Insulated Throat Dimensions in Inches Trade Size Catalog Catalog Body Thread Max. Flex. (inches) Number Number Length Length Width Opening Type AC-50 UL Listed: E-852 UL Listed for armored cable and flexible steel conduit. UL Listed flexible metal conduit fittings are suitable for use in Hazardous Location under NEC 50.4(B) Class I Div. II, and suitable as a grounding means under NEC 250.8(5)&(6). CSA Certified: 5. CSA Certified for armored cable. 8 ( 2 KO) AC-8 AC-8T 8 2 AC-50 AC-50T 5 4 AC-5 AC-5T 2 8 UL Standard: 54B CSA Standard C22.2 No. 8 NEMA: FB- 4 2 4 2-64 25 2-5 2 2 - Type 25-8C Duplex Connector To ground and secure two Armored Cables to boxes and enclosures. Dimensions in Inches Trade Size Catalog Body Thread Max. Flex. (inches) Number Length Length Width Opening 8 ( 2 KO) 25-8C 2-2 For armored cable 4/2 to 0/2 or combination of sizes Furnished with locknuts. Male hubs-nps Type 25-8C Malleable Iron/Zinc Plated UL Listed: E-852 UL Listed flexible metal conduit fittings are suitable for use in Hazardous Locations under NEC 50.4(B) Class I Div. II, and suitable as a grounding means under NEC 250.8(5)&(6). CSA Certified: 5 UL Standard: 54B CSA Standard C22.2 No. 8 NEMA: FB- 0 N. Frontage Road Skokie, Illinois 600

KB Cable Connectors Type AC & Type ACV 0 2-Screw Clamp Connectors 0 Angle Squeeze Connectors For Armored Cable & Flexible Metal Conduit KB To ground and secure Armored Cable and Flexible Metal Conduit to boxes and enclosures. Male hub threads - NPS. All center stopped. Furnished with locknuts. Available with insulated throat Also suitable for NM and SE cable Type ACV-8 Type AC-50 Type AC-200 UL Listed: E-852 ACV-8 through ACV-5: UL Listed for armored cable and flexible metal conduit. UL Listed: E-85 AC-00 through AC-400: UL Listed for flexible metal conduit. UL Listed flexible metal conduit fittings are suitable for use in Hazardous Locations under NEC 50.4(B) Class I Div. II, and suitable as a grounding means under NEC 250.8(5)&(6). CSA Certified: 5 and 584. Armored cable and Flexible Metal Conduit UL Standard: 54B CSA Standard C22.2 No. 8 NEMA: FB- Type ACV-50 Type AC-25 Insulated Throat Dimensions in Inches Trade Size Catalog Catalog Flex (inches) Number Number A B C Opening 8 ( 2 KO) ACV-8 ACV-8T 5 2 ACV-50 ACV-50T 4 4 ACV-5 ACV-5T 8 2 64-2 2 25 2-6 64 2 2-64 AC-00 AC-00T 2 4-8 4 AC-25 AC-25T 2 2 2-5 8 2 AC-50 AC-50T 2 4-2 2 AC-200 AC-200T 4 4 4 2-2 2 2 AC-250 AC-250T 6 4 4 5 8 2 4 - AC-00 AC-00T 4 5 8 4-2 2 AC-50 AC-50T 0 4 4 4 45 64-4 5 2 4 AC-400 AC-400T 4 4 4 64-4 Type AC-250 Type AC-400 0 N. Frontage Road Skokie, Illinois 600

KB4 Cable Connectors For Armored Cable, Flexible Metal Conduit, Interlocked Metal Clad Cables, NM & SE Cable Type KC 2-Screw & 4-Screw Clamp Connectors KB4 To ground and secure Armored Cable, Flexible Metal Conduit and Interlocked Metal Clad Cables to boxes and enclosures. To secure NM and SE Cables to boxes and enclosures. Available with insulated throats. Male hub threads - NPS. All center stopped. Provided with locknuts. UL Listed :E-852, E-858, E-856, E-85 CSA Certified: 5 UL Standard: 54B CSA Standard C22.2 No. 8 NEMA: FB- Type KC-50 Type KC-6 Type KC-00 Type KC-00 Type KC-50 Type KC-500 Insulated UL FILE NUMBER Throat Flex. Trade Size Catalog Catalog Metal Armored Metal Sheathed SE Dimensions in Inches Flex (inches) Number Number Clad Cable Conduit Cable Cable A B C Opening 2 KC-50 KC-50T E-852 E-852 E-852 E-852 E-852 8 2 ( 4 KO) KC-5 E-852 E-852 E-852 E-852 E-852 8 8 8 2-2 2 2-5 4 KC-5 KC-5T E-852 E-852 E-852 E-852 E-858 4 ( KO) KC-6 E-852 E-852 E-852 E-852 2 2 8 2 2 8 8-2 2 2-2 E-856 E-858 KC-00 KC-00T E-85 E-856 E-858 4 4 KC-25 KC-25T E-85 E-856 E-858 5 2 KC-50 KC-50T E-85 2-8 2 2-5 8 4 8-2 2 KC-200 KC-200T E-85 2 8 8 4 4 2 8-2 2 2 2 KC-250 KC-250T E-85 2 5 8 8 5 2 - KC-00 KC-00T E-85 5 2 2 5-2 2 KC-50 KC-50T E-85 4 6 2 2 2-4 4 KC-400 KC-400T E-85 4 4-4 5 KC-500 KC-500T UL & CSA Listing not applicable. 5 2 8 8 5 5-5 2 0 N. Frontage Road Skokie, Illinois 600

KB5 Cable Connectors For Armored Cable KB5 Type C-5L 2-Screw Connectors Trade Size Catalog Dimensions in Inches Cable (inches) Number A B C Opening To ground and secure Armored Cable to boxes and enclosures. 8 ( 2 KO) C-5L 2 8 8-5 8 End stopped Male hub threads NPS Provided with locknut Type C-5L UL Listed: E-852 CSA Certified: 5 UL Standard: 54B CSA Standard C22.2 No. 8 NEMA: FB- Front View 0 N. Frontage Road Skokie, Illinois 600

KB6 Cable Connectors Aluminum Sheathed For Smooth & Corrugated ALS Cable Type ALS-50-525 KB6 To ground and secure Aluminum Sheathed Cable to boxes and enclosures. End stopped Male hub thread NPS Furnished with locknut Type ALS-50-525 End Stopped UL Listed: E-04 UL Listed for smooth and corrugated aluminum sheathed cable. UL Standard: 54B NEMA: FB- Dimensions in Inches Length Length Width Cable Range Catalog K.O. Size of of of Dia. over Armor Number Inches Clamp Thread Clamp Min. Max. ALS-50-525 2 5 2 8.5.525 0 N. Frontage Road Skokie, Illinois 600

KB Cable and Flexible Cord Connectors For Non-Metallic Sheathed Cable Type C-LS Type 806 & Type 06 2-Screw Connector For round cable-open throat type KB Type C-LS - to secure Non-Metallic Sheathed Cable to boxes and enclosures. Type 806 and Type 06 Series - to secure Non-Metallic Sheathed Cable, Service Entrance Cable and Flexible Cords to boxes and enclosures. Type C-LS Type 806 Type 08 Available with insulated throats Furnished with locknuts. Male hub threads NPS. UL Listed: E-856 UL Listed for 806, 06Z, 08, 0 for NM and SE Cables UL Listed: E-858 UL Listed for 806, 06Z for SE Cable C-LS - UL Listed for NM Cable. Type 0 Insulated Throat Trade Size Catalog Catalog Clamp Opening Dimensions in Inches (inches) Number Number Min. Max. Width A B C Certified File No. 584 NM Cable UL Standard: 54B CSA Standard C22.2 No. 8 NEMA: FB- 2 *C-LS *C-LST..6 -- 4 806 806T..84.84 06Z 06T.42.05.05 4 0 0T.5.4.4 2 08 08T..45.55 8 2 0 0T. 2.0 2.0 5 *Longer screw to accommodate extra flexible cables. Not CSA Certified. 8 2 2 5 8 2 4 4 8 0 N. Frontage Road Skokie, Illinois 600

KB8 Cable and Flexible Cord Connectors For Non-Metallic Sheathed Flat Cable Type 806F & Type 06F 2-Screw Connector KB8 To secure Non-Metallic Sheathed Flat Cable, SE/SEU Flat Cable, and other oval (flat) non-metallic cables to boxes and enclosures. 2-screw double clamp - open throat type. Furnished with locknut. Male hub threads - NPS. Type 806F Type 08F Type 0F SEU Cable Range Clamp Opening Catalog K.O. Size (Braid Neoprene Dimensions in Inches Range Number (inches) and PVC Jacketed) A B C Min. Max. Width UL Listed: E-856 UL Listed for NM and SE Cables Certified File No. 584 UL Standard: 54B CSA Standard C22.2 No. 8 NEMA: FB- 806F* 4 #0 to #6 06F #0 to #2 0F 4 # to #/0 08F 2 #/0 to #/0 8 0F 2 #2/0 to #4/0 5 *Not CSA Certified Except PVC #4/0 only...82.82 2.0.06.06 2.50.5.5 5 8 2 4.5..56 4 8..4.8 0 N. Frontage Road Skokie, Illinois 600