DP86 Constant Voltage with Fitting

Similar documents
86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

D5100 Industrial Differential Pressure Transducer

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

D5100 Industrial Differential Pressure Transducer

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

86BSD Digital Output

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

Standard SPECIFICATIONS FEATURES APPLICATIONS

MSP100 Pressure Transducer

86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated

Sub psi SPECIFICATIONS

86BSD Digital Output

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

MSP340 Pressure Transducer

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

MSP100 Pressure Transducer

86BSD Digital Output

89BSD Digital Output

M7100 Pressure Transducer

MSP300 Pressure Transducer

SPECIFICATIONS. SENSOR SOLUTIONS ///LM Page 1 09/2015

FC23 Compression Load Cell

MS4525 SPECIFICATIONS

FC22 Compression Load Cell

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

LOW PRESSURE Intrinsically Safe Transducer AST44LP

M5200 Industrial Pressure Transducer

U5300 Industrial Pressure Transducer

U5700 Submersible Liquid Level Pressure Transducer

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

P125 High Pressure Sensor

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

M5800 Pressure Transducer with Rotatable Display

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

M5800 Pressure Transducer with Rotatable Display

MODEL 4000A & 4001A ACCELEROMETER

U5600. Wireless Pressure Transducer SPECIFICATIONS

ELAF LOAD CELL SPECIFICATIONS FEATURES

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

The Importance of Pressure Sensors in HVACR Systems

MODEL 834M1 ACCELEROMETER

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

PT9420 (Extended Range)

HM1520LF Relative Humidity Module

HM1500LF Relative Humidity Module

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

TS105-10L5.5MM Thermopile Sensor

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

Cable Actuated Sensor Industrial User Scalable VDC Output

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

OPERATION MANUAL MODEL & ACCELEROMETER

Cable Actuated Sensor Industrial User Scalable 4 20mA

PT9150 (Extended Range)

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

15203B 25203B 35203B Uniaxial Biaxia Triaxial

LMM-H03 Mass Air FLow Sensor

Cable Actuated Sensor Industrial Incremental Encoder Output

OPERATION MANUAL MODEL 4610 ACCELEROMETER

OPERATION MANUAL MODEL 805 ACCELEROMETER

OPERATION MANUAL MODEL 8102 ACCELEROMETER

LMM-H04 Mass Air FLow Sensor

OPERATION MANUAL Model 8011 & mA

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

MINIATURE ELECTRONIC PRESSURE SCANNERS ESP-16HD/32HD/64HD

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

OPERATION MANUAL MODEL 3038 ACCELEROMETER

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

PT9600. Cable Actuated Encoder Reel. General. Environmental

MODEL ACCELEROMETER

Pressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

MEAS EMITTER ASSEMBLY ELM-4000 SERIES

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

OPERATION MANUAL MODEL 805M1 ACCELEROMETER

TSEV01S01C10 SPECIFICATIONS

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

Gage Unamplified Noncompensated Flow-Through

DOG2 MEMS SERIES USB INCLINOMETER

Interactive Catalog Replaces Catalog Pages

OPERATION MANUAL MODEL 3255A ACCELEROMETER

TESS WIRELESS SENSOR TAG DEMO V1.1

CABLES AND ACCESSORIES FOR TRUBLUE DATA LOGGERS

Interactive Catalog Replaces Catalog Pages

NTC THERMISTOR SENSOR PERFORMANCE

FSS-SMT Series. Low Profile Force Sensor

Installation Instructions for the

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR IOS

Transcription:

SPECIFICATIONS 316L SS Wet/Wet Differential Low Pressure 0 100mV Output The DP86 constant voltage with fitting differential pressure sensor is a double-sided, media compatible, piezoresistive silicon pressure sensor packaged in a 316L stainless steel housing. The DP86 constant voltage with fitting can be designed with up to 8 different threaded process fittings. The sensing package utilizes silicone oil to transfer pressure from the two 316L stainless steel diaphragms to a single sensing element. The DP86 constant voltage with fitting is designed for high performance, low pressure applications where differential pressure measurement is required. The stainless steel package makes it suitable for use in liquids and corrosive environments. Please refer to the DP86, uncompensated, non-silicone oil, constant current and constant voltage (fittings and cable design) for more information on different features of the DP86. SENSOR SOLUTIONS ///DP86 6/2017 Page 1

FEATURES Threaded Process Fittings Up to -40ºC to +125ºC Operating Range Up to ±0.1% Pressure Non Linearity Solid State Reliability Low Pressure APPLICATIONS Level Controls Tank Level Measurement OEM Equipment Corrosive Fluids and Gas Measurement Systems Flow Measurements STANDARD RANGES Range psid Range bard 0 to 1 0 to.07 0 to 5 0 to.35 0 to 15 0 to 001 0 to 30 0 to 002 0 to 50 0 to 3.5 0 to 100 0 to 007 0 to 300 0 to 020 0 to 500 0 to 035 SENSOR SOLUTIONS ///DP86 6/2017 Page 2

PERFORMANCE SPECIFICATIONS Supply Voltage: 10Vdc Ambient Temperature: 25 C (unless otherwise specified) PARAMETERS Span 005PSI 015PSI MIN TYP MAX MIN TYP MAX 1psi: 77, 80, 83 5psi: 98, 100, 102 UNITS 99 100 101 mv Zero Pressure Output -2.0 0 2.0-1.0 0 1.0 mv 1 Pressure Non Linearity 1psi: -0.30 to 0.30 5psi: -0.20 to 0.20 NOTES -0.10 0.10 %Span 2 Pressure Hysteresis -0.10 ±0.02 0.10-0.05 ±0.02 0.05 %Span Repeatability ±0.02 ±0.02 %Span Accuracy RMS of NL,HY,RP ±0.6 ±1.0 ±0.6 ±1.0 %Span Input Resistance 5500 9000 12500 5500 9000 12500 Ω Output Resistance 4000 30000 4000 25000 Ω Temperature Error Span -1.5 1.5-1.0 1.0 %Span 3 Temperature Error Offset -2.5 2.5-1.0 1.0 %Span 4 Thermal Hysteresis Span -0.25 ±0.05 0.25-0.25 ±0.05 0.25 %Span 3 Thermal Hysteresis Offset -0.25 ±0.05 0.25-0.25 ±0.05 0.25 %Span 3 Long Term Stability Span ±0.10 ±0.10 %Span/Year Long Term Stability Offset ±0.25 ±0.10 %Span/Year Line (Common Mode) Pressure 1000 1000 psi Line Pressure Effect on Zero 1psi: 4.0 Max 5psi: 0.8 Max 0.5 %Span/1Kpsi Supply Voltage 10 14 10 14 V 4 Output Load Resistance 5 5 MΩ 5 Insulation Resistance (50Vdc) 50 50 MΩ 6 Output Noise (10Hz to 1KHz) 1.0 1.0 uv p-p Response Time (10% to 90%) 0.1 0.1 ms Pressure Overload Pressure Burst Compensated Temperature Operating Temperature 1psi: 10X Max 5psi: 3X Max 1psi: 12X Max 5psi: 4X Max 1psi: 0 C to 50 C 5psi: 0 C to 70 C 1psi: -40 C to +85 C 5psi: -40 C to +125 C 3X Rated 7 4X Rated 7-20 +85 C -40 +125 ºC 8 Storage Temperature -40 +125-40 +125 ºC 8 Voltage Breakdown Shock Vibration Media Pressure Port 500V rms @ 50Hz, Leakage Current < 1mA 50g, 1msec half sine shock per MIL-STD-202G, Method 213B, Condition A ±20g MIL-STD 810C, Procedure 514.2, Figure 514.2-2, Curve L Liquids and gases compatible with 316/316L Stainless Steel Notes 1. Measured at ambient. 2. Best fit straight line 3. Over the compensated temperature range with respect to 25 C. 4. Guarantees output/input ratiometricity. 5. Load resistance to reduce measurement errors due to output loading. 6. Between case and sensing element. 7. For H (high-end) port, rated or 1000psi whichever is less. For L (low-end) port rated or 150psi whichever is less. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer. 8. -40 C to +125 C for 5psi. Maximum temperature for product with standard cable and connector is -20 C to +105 C. SENSOR SOLUTIONS ///DP86 6/2017 Page 3

DIMENSIONS Dimensions are in inches [mm ] SENSOR SOLUTIONS ///DP86 6/2017 Page 4

CONNECTIONS ORDERING INFORMATION DP86-015P - 1 V R Electrical (C = Ribbon Cable with Connector, R = Ribbon Cable) Type (V = Constant Voltage, Compensated) Fitting (See Fitting Table) Unit (P = psi, B = Bar) Pressure Range Model NORTH AMERICA Measurement Specialties, Inc., Tel: 800-522-6752 Email: customercare.frmt@te.com EUROPE Measurement Specialties (Europe), Ltd., Tel: 800-440-5100 Email: customercare.lcsb@te.com ASIA Measurement Specialties (China), Ltd., Tel: 0400-820-6015 Email: customercare.shzn@te.com TE.com/sensorsolutions Measurement Specialties, Inc., a TE Connectivity company. Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity s obligations shall only be as set forth in TE Connectivity s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. 2015 TE Connectivity Ltd. family of companies All Rights Reserved. SENSOR SOLUTIONS ///DP86 6/2017 Page 5