15R HARDWARE INSTALLATION GUIDE

Similar documents
Installation and Operation Manual Low Power (LP) DC Power System

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Carbon Rack Enclosure

1U ULTRA Compact System

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

Installation Guide. For Models: E-MLV36BNK4LK1 E-MLV36ESP4LK1 E-MLV36WW4LK1 READ THESE INSTRUCTIONS AND AND SAVE THEM FOR FUTURE USE

ASTRO EXPRESS 2 HOT WATER DELIVERY SYSTEM

INSTALLATION INSTRUCTIONS

Installation Instructions

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Installation Guide. For Models: E-DCF52BNK5C3 E-DCF52FBZ5C3 E-DCF52MWW5C3 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

52 BARSTOW CEILING FAN

Installation Instructions

Installation Guide. For Models: E-PD52ABZ5C4 E-PD52BP5C4 E-PD52WW5C4 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

High-Density Industrial

Refrigerated Incubator Model and Operating Instructions

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

52 SAN LUCAS CEILING FAN

Smart Water Heater Controller

Installation. Built-in Full Height Wine Cellar VCWB301

BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS

WAILEA OWNER S MANUAL

Viking Installation Guide

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

Installation instructions for Glass Rack - Shelf Combo

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

VARIABLE SPEED GRINDER OWNER S MANUAL R MANUAL VERSION SERIAL #

Tank, Heater, and Control Operation Manual REV. E DATE: 04May2015

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

AGF Manufacturing Inc. Model Owner s Manual INST-5400A_V /15

Astro Express 2 - Hot Water Delivery System

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

SECAP Conveyor TC72 / Dryer TD72

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

CEILING FAN OWNER'S MANUAL

ELSTON 52 CEILING FAN

Cisco TelePresence MCU 4200 Series safety and compliance information

Installation and Operation Manual For Hunter Ceiling Fans

ACQUITY UPLC HT Column Heater Instructions

CEILING FAN OWNER S MANUAL

COMMERCIAL REFRIGERATOR AND FREEZER USER S MANUAL

T874 Multistage Thermostat and Q674 Subbase

TP970 Series CONVERTASTAT Kits

Microwave Oven. IMPORTANT SAFETY INSTRUCTION Never operate the oven when it is empty or without the glass turntable.

COR-20 STANDALONE MAIN TITLE GOES MODE USER GUIDE HERE

APARTMENT MAINTENANCE SERIES

FLCH4R Garage and Utility Electric Heater

HDCVI PTZ Camera. 6C Series. Quick Start Guide Version Dahua Technology USA Inc.

Basin Heater. user manual INSTALLATION OPERATION MAINTENANCE

TOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions

48 TAYLOR CEILING FAN

PRE INSTALLATION PROCEDURES

Mounting 4000 and Appliances with Telescoping Rails

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

20-GALLON MOBILE PARTS WASHER OWNER S MANUAL

Veritas Appliance Hardware Service Procedure

52 BAYTOWNE CEILING FAN

ST. KITTS CEILING FAN

CEILING FAN OWNER S MANUAL

CEILING FAN OWNER'S MANUAL

Emergency Lighting Transfer System Model: ELTS2 Installation and User Operation Manual

Owner s Guide and Installation Manual

HDCVI PTZ Network Camera

GA3650TB Blower Accessory

OPERATOR S MANUAL. BASIC PROJECT CENTERS Some instructions and drawings may not apply to your specific unit. SAFETY SERVICE PARTS CAPACITIES

Installation Instructions

SS1095 Ice Maker.

CEILING FAN OWNER'S MANUAL

AVANI Grinding Booth

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

18 INCHES, OSCILLATING STAND FAN

Instruction Manual Model Backup Switch, 1 for 8

Installation Instructions for Models: HES232U, HES236UHES246U, HES247U, HES245U, HES242U, HES256U, HES255U, HES252U

OPERATION MANUAL. Move it. Hang it. Rack it. Stack it. MaxPower Corporation 230 Yuma Street Denver, CO

Easy-Lam School Budget Roll Laminator

2 Installation Instructions For Vari-Fan Ceiling Fans Installation Instructions For Vari-Fan Ceiling Fans 11

Installation Instructions

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

52 STRATHMERE CEILING FAN

Owner s Guide and Installation Manual

STOP! Read this notice. STOP! Read before proceeding. These instructions are for gas conversion of the Evergreen boiler only.

36"x17" Portable Tool Chest and 6-Drawer Tool Cabinet

HOME CINEMA SPEAKER PACKAGE

CR24 INSTALLATION INSTRUCTIONS

SUTTON 52 CEILING FAN

Q7800H Integrated Burner Control Subpanel

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

User Manual. Power Distribution Unit. Version: 1.0

NS-AP6500M/NS-AP6500E

Torrena 42 Ceiling Fan

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

HX18 Heater. Read all instructions before using the heater. Contents

CEILING FAN OWNER'S MANUAL

3CLMR56XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3CLMR56XXD

PREMIUM 12 PIZZA & SNACK OVEN INSTRUCTION MANUAL. IMPORTANT: Safety Recommendations Inside 508FCG QUALITY VALUE PERFORMANCE

Viking Installation Guide

OPERATING INSTRUCTIONS MIGHTYLAM 2700 ROLL LAMINATOR

Transcription:

15R HARDWARE INSTALLATION GUIDE

Table of Contents Section 1 Ratings....................................................................... 3 Section 2 Site Preparation................................................................ 4 Section 3 Unpacking the Appliance........................................................ 4 Section 4A Installing the Appliance in a 4 Post Rack............................................ 5 Section 4B Installing the Appliance in a 2 Post Rack............................................ 6 Section 5 Rear Panel Connections and Cabling............................................... 7 Section 6 Front Panel Operation........................................................... 8 NetSpective Web Filter 15R Hardware Installation Guide Page 2

1. Ratings V: 100 240 VAC (auto range) Hz: 50 60 A: 2.6 Max 2. Site Preparation Setup location, rack and appliance precautions Elevated Operating Ambient Temperature If installed in a closed or multi unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. Always keep the rack s front door and all panels and components on the appliances closed when not servicing to maintain proper cooling. Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Leave enough clearance, approximately 25 inches in the front, and 30 inches in the back of the rack to enable you to access appliance components and allow for sufficient air flow. Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. ALL RACKS MUST BE MOUNTED SECURELY. Ensure that all leveling jacks or stabilizers are properly attached to the rack. If installing multiple appliances in a rack, make sure the overall loading for each branch circuit does not exceed the rated capacity. Do not slide more than one appliance out from the rack at a time. Extending more than one appliance at a time may result in the rack becoming unstable. Install your appliance in the lower part of the rack because of its weight and also for ease in accessing appliance components. Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern. Reliable Earthing Reliable earthing of rack mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips). Install near appropriate AC outlets, and Ethernet hubs or individual jacks. Be sure to install an AC Power Disconnect for the entire rack assembly. The Power Disconnect must be clearly marked. Ground the rack assembly properly to avoid electrical shock. NetSpective Web Filter 15R Hardware Installation Guide Page 3

3. Unpacking the Appliance Before you begin: Verify that the ship kit includes a power cord, the screws and the rack clips (shown below) that you will need to install the appliance in your rack. 4-POST RACK Four (4) M6 x 16 mm Four (4) Rack Clips Phillips Pan Head Screws 2-POST RACK Four (4) M5 x 12 Phillips Flat Head Screws and Four (4) M5 x 12 Cone Washers Front view Side view Front view Side view Rear view Front view Side view Cone washer NOTE: Use the hardware supplied with your specific rack if different from the hardware supplied in this kit. NetSpective Web Filter 15R Hardware Installation Guide Page 4

4A. Installing the Appliance in a 4 Post Rack Step 1 Install two rack clips into the top and bottom of three holes on each side in the rack as shown. The tabs on each should be on the top and bottom to help stabilize them in the holes. No tools are needed to install the clips, firmly press them into place Make sure the clips are level in height on the left and right sides for proper alignment to allow accurate appliance installation. Install two rack clips in the top and bottom of three holes 4-Post Rack Leave middle hole empty Step 2 Install the appliance in the rack as shown. Insert one M6 x 16 screw* through the top and bottom holes in the ears into the rack clips on each side of the rack. *NOTE: Refer to your rack s mounting hardware for the proper size and type of screws to secure the appliance in the rack. Two (2) M6 x 16 pan head screws on each side* Tighten each screw to secure the appliance in the rack. 4-Post Rack NOTE: When installing (or removing) the appliance from the rack make sure to support the unit at all times. NetSpective Web Filter 15R Hardware Installation Guide Page 5

4B. Installing the Appliance in a 2 Post Rack Step 1 Install the appliance in the 2 post rack as shown. Insert one M5 x 12 screw* and one M5 x 12 cone washer* through the top and bottom holes in the ears on each side into the threaded holes in the rack. *NOTE: Refer to your rack s mounting hardware for the proper size and type of screws to secure the appliance in the rack. * Tighten each screw to secure the appliance in the rack. NOTE: When installing (or removing) the appliance from the rack make sure to support the unit at all times. NetSpective Web Filter 15R Hardware Installation Guide Page 6

5. Rear Panel Connections and Cabling CAUTION Slide rail/mounted equipment is not to be used as a shelf or a work space. A B C D E F G H J L I K M N O P A Power Supply Module Fan G LAN Port 6 M LAN Port 2 B Power Supply AC Inlet H PCI Card Expansion Slot N LAN Port 4 C COM Port I USB Port 6 O LAN Port 7 D IPMI or LAN Port 5 J USB Port 7 P VGA Port E LAN Port 1 K USB Port 2 F LAN Port 3 L USB Port 3 1 3 2 1 2 Step 1 Connect the power cord. Step 2 Connect the Ethernet cables. Step 3 Connect any other required cables. Proceed to Section 6, Front Panel Operation on page 8. NetSpective Web Filter 15R Hardware Installation Guide Page 7

6. Front Panel Operation Power on the Appliance: Press the I/O Power Button located on the far right of the front panel. Blue LED Red LED I/O Power Corporate Office Grom Educational Services, Inc. 3280 Pointe Parkway, Suite 2500 Peachtree Corners, GA 30092 Phone 678 459 1410 Fax 678 459 1411 Email netspectivewebfilter@gromedu.com www.gromedu.com Copyright Grom Educational Services 2018