PIV & MIV Loft Mounted Unit INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Similar documents
ECo 2 Wall USER GUIDE FOR RESIDENT

HOTLINE:

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Wiring the fan correctly...

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

HOTLINE:

Thank you for choosing EnviroVent

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent

Wiring the fan correctly...

230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5

ECo 2 Wall INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

November This product has been reconfigured Please read these instructions

Dust Mites. You are sharing your bed with thousands of them! Virus. Mould / Fungi. Mites. Allergy / Asthma. Tracheal Infection. Chemical Reactions

The Range Condensation Control Systems. Positive Input Ventilation

What is PIV? Positive Input Ventilation

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Condensation. 1

Application and Installation Guide (excluding Solar Air Collectors)

Watch the heatsava video

LANDLORDS & LETTINGS VENTILATION SOLUTIONS

Damp, Mould and condensation. The Facts About

DRI-ECO-HEAT-HCS Whole House Ventilation Unit with Hall Control

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Introducing the RetroVent

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

60cm Integrated Turbo Extractor

WHHR Midi & Midi Lite

A guide to. e Condensation. and how to reduce it

your home: Damp, condensation & mould

100cm Chimney Hood GB IE

DRIMASTER Anti-Condensation & Whole House Ventilation Unit Installation and Maintenance

DRI-ECO-HEAT-HC. Whole House Ventilation Unit with Hall Control. Installation, Maintenance and Operation

KUDOS. Instruction leaflet

ART cm Island Curved Glass

Purge Ventilation Unit. Product Manual. ventilation systems TP625

INSTALLATION & USER INSTRUCTIONS

DRIMASTER 2000 and DRI S Anti-Condensation & Whole House Ventilation Unit Installation and Maintenance

Installation Instructions & Operating Manual IMPORTANT

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

DRI-365 Anti-Condensation and Whole House Positive Input Ventilation Unit

Best Practice Guidance. Best Practice Guidance Positive Input Ventilation (PIV) System

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

HELPLINE If you have any difficulty with your appliance, do not hesitate to call us. Website

Stainless Steel and Glass Angled Extractor

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

anglia Condensation in your property A guide to the causes and how to remedy the problem

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

EH0533 Indoor Climate Control

Xpelair Simply Silent TM Contour Fan

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...

PANEL HEATER OPERATING INSTRUCTIONS. For Models: TWFP10000, TWFP PK

Keep your home free from damp and mould

DRI-ECO-LINK-HC 1.0 INTRODUCTION 4.0 DIFFUSER INSTALLATION 2.0 IMPORTANT NOTES TO INSTALLERS 3.0 LOFT INSPECTION

SmartVent. NZ's home ventilation specialists. Become the climate expert in your home. SMARTVENT HOME VENTILATION SYSTEMS

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

User Guide PLEASE READ BEFORE USE AND KEEP FOR FUTURE REFERENCE.

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Avoid damp and condensation in your home

MeacoCool MC Series Portable Air Conditioner

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

INSTALLATION & USER INSTRUCTIONS

USER MANUAL. ICON60H Version 00. Vertical Glass Hood

Stainless Steel Chimney Extractor

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

Chmney Hood - Model: H91PK H91PX H101PK H101PX. COOKER HOOD - User instructions

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Stainless Steel Chimney Extractor

How to get the most from your Integrated Tumble Dryer HJA 8800

KEEP YOUR HOME FREE FROM DAMP, CONDENSATION AND MOULD

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

Double Door - Dual Zone Wine Cooler

Meaco 10L small home dehumidifier Instructional Manual

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

USER INSTRUCTION MANUAL. Autofill Water Boiler

SH3020 USER INSTRUCTIONS

EH0554 Indoor Climate Control

Health and Safety PLEASE BE AWARE OF HOT SURFACES HANDLE WITH CARE. Treating scalds

HR100R. Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery. Installation and Servicing Instructions

Xpelair Simply Silent DX150

B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page Installation Guide

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

Transcription:

PIV & MIV Loft Mounted Unit INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Made in Harrogate UK Thank you for choosing EnviroVent The fastest growing ventilation company in the UK. You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore ensure that this product is treated with care and installed properly i.e. for the life of the building. If the unit is mishandled you might break it! This invalidates the warranty. And remember, if you have any problems please call our dedicated Technical Team. We are always pleased to help and in an emergency will come out to site quickly, completely free of charge. HOTLINE: 0345 27 27 810 1 PIV & MIV Loft Mounted Unit SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON: 0345 27 27 810

PRE-INSTALLATION CHECKLIST Check that the loft has adequate cross flow ventilation. Check that all party walls are intact, seek advice if the wall is missing or broken. Check that any flue which passes through the loft is not damaged, seek advice if the flue is in a poor state of repair. Check for any flued appliance which may draw air from the loft, report to the client. Check for any holes in the ceilings which may allow leakage of air to the loft and repair as appropriate. Check that the water storage tank is covered. FIXING KIT Description 8 X FOAM PADS 4 X PENNY WASHERS 4 X PLASTER BOARD PLUGS 4 X WOOD SCREWS (10 X 1.5) 4 X WOOD SCREWS (10 X 3) Item 4 X WOOD SCREWS (8 X 1) 4 X WOOD SCREWS (8 X 1.5) ROLL OF INSULATION TAPE AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 2

INSTALLATION INSTRUCTIONS IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. Smoke Detectors It is important that any open side of the plastic diffuser is not positioned within 1m of a smoke detector. If the diffuser cannot be repositioned, up to two sides of the diffuser may be closed off using the plastic blanking plate supplied (Loft only) so that the open sides face a minimum 1.5m unobstructed path away from the detector. In 3 floor properties a metal fire diffuser should be fitted at minimum of 1m from the detector (see page 8). SAFETY AND RECOMMENDATIONS All wiring must comply with Building Regulations and the current I.E.E. Wiring Regulations (BS7671) or the equivalent standards for your country. The final installation should be examined and tested by a qualified electrician. Precautions must be taken to avoid the backflow of gases into the dwelling from the open flue of gas or other fuel-burning appliances. Make sure the mains supply complies with the rating label for voltage, frequency and phase. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. 3 PIV & MIV Loft Mounted Unit SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON: 0345 27 27 810

INSTALLATION DIAGRAMS STANDARD INSTALLATION Also see page 7 for MIV Loft Mounted Unit (twin spigot) installation method, and page 8 for installations in 3 storey properties. Installation diagram for the EnviroVent Loft Mounted Unit 650mm x 50mm x 25mm batten Contents for unit Ceiling joists Heater enable/disable switch (Heater version only) volt-free *Unswitched fuse spur fitted with 3 Amp fuse 230V A.C. 3 core mains lead For fixing instructions, please refer to the fixing instructions (Fig. 1) on page 5 405mm 1 x Cardboard template 1 x Diffuser 1 x Fixing kit 1 x Unswitched fuse spur 1m x 200mm Flexi duct Additional contents for unit with heater 1 x Heater enable switch *Subject to capacity, it is possible to connect the EnviroVent Loft Unit with heater to a lighting circuit. If in doubt, wire through a ring main supply. Ensure the volt-free heater enable/disable switch is fitted in a suitable position for the user. This appliance must be earthed. UNIT DIMENSIONS Dimensions of the EnviroVent Loft Mounted Unit - 470 x 405 x 372mm 372mm 470mm AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 4

INSTALLATION INSTRUCTIONS FIRST STAGE Position a dustsheet beneath the site you have chosen for cutting the hole for the diffuser. Protect your lungs with a mask. Enter the loft space with the EnviroVent unit and check there are no obstructions to your chosen position for the diffuser. Using the template supplied mark the hole for the diffuser and cut the 220mm hole in the plasterboard (see page 7 for additional MIV installation instructions). N.B The unit is designed to be taken apart and re-assembled to overcome restricted access through small loft hatches. Fig.1 Fixing Instructions 10 x 3 screw Penny washer Foam pad 50mm x 25mm batten with 20mm clearance hole Foam pad Existing joist SECOND STAGE Position the EnviroVent unit on 50mm x 25mm wooden battens (not supplied) laid across the joists or raised platform if the insulate is thicker than the joists so that the ducting between the unit and the diffuser is not impeded. Lightly screw the drilled battens to the joist through the rubber mounts and metal penny washer provided. Fit the ducting to the unit spigot using half of the tape provided. THIRD STAGE Push ducting through the hole in the ceiling. Return to the hallway and connect the ducting onto the neck of the diffuser using rest of the tape provided. Ensure that the diffuser is aligned correctly with the walls of the hallway. Adjust if necessary. Fix the diffuser in position using plasterboard plugs and the screws provided. FOURTH STAGE The EnviroVent unit must only be installed by a competent person and should be connected to an electrical supply in accordance with the current electrical regulations. A disconnection device should be used in the fixed wiring. FIFTH STAGE Check the unit is working correctly. Set the unit s controls according to the house size and check that the filters are securely in place. SIXTH STAGE Method of operation: Adjust the settings on the top of the unit by pressing the house setting button. By pressing the button, the correct ventilation rate for the size of the house can be selected i.e. if the unit is on SMALL / TRICKLE and the button is pressed, the unit will then switch to MEDIUM. Similarly, if the unit is on BOOST and the button is pressed, the unit will then switch to SMALL / TRICKLE. SMALL / TRICKLE PRESS BUTTON MEDIUM PRESS BUTTON LARGE PRESS BUTTON BOOST PRESS BUTTON As a rule of thumb, the setting on the EnviroVent Loft Unit should match the number of bedrooms i.e. 1-4 5 PIV & MIV Loft Mounted Unit SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON: 0345 27 27 810

INSTALLATION INSTRUCTIONS SIXTH STAGE cont. - Wireless units only For heater enable/disable On commission the unit will default to the trickle flow rate with heater enable on Press button once, to indicate current fan speed and heater status. LEDs stay on constant for a few seconds Press button for five seconds turns heater enable off. LED will flash red for a few seconds Press button for five seconds turns heater enable on. LED will show constant red for a few seconds Remote Control in range (Green) LED Colours Constant Red To change speed setting Next press moves the unit to the next speed and so on. When the speed is chosen the LED remains on for a few seconds Boost (Green) To pair additional remote control switches: 1. Turn the unit off at the isolation point. 2. Restore power; for 20 seconds from restart the unit will be in pairing mode. 3. Press the remote button once within the 20 seconds and the control will pair to the unit. 4. Successful pairing is indicated by a green light on the control. N.B: When the battery needs replacing, unscrew the front cover. The battery is located on the back of the cover. Battery type - 3V Lithium, CR2032. Heater enable (Red) Heater enable ON Auto LED stays on constant for a few seconds. Heater enable OFF Auto LED flashes for a few seconds. Remote Control out of range (Red) Flashing Red Constant Green (Green) If the two LEDs situated just above the button flash alternately red and green (when it is pressed) the control will need to be reprogrammed. Call your maintenance company or EnviroVent for advice. AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 6

MIV INSTALLATION INSTRUCTIONS Twin Spigot This addition to the fixing instructions explains the methodology of installing the twin spigot system. This variation to the EnviroVent Loft Mounted Unit is necessary where: The hallway is very small, particularly when there is limited heating in the house The loft hatch fills the hallway ceiling Air is required to be diffused into a remote zone, such as a bedroom Cut two 105mm holes in the ceiling in the positions chosen where air is required to be delivered. Use the distance from the Loft Mounted Unit to each hole to balance/favour airflow: i. Equal air supply required - diffusers equidistant from unit ii. More air supply required in hallway - short run to diffuser in the hall (This is the recommended method of installation) Connect the flexi ducting to the twin spigot and hold in position with a cable tie on each outlet. MIV TWIN SPIGOT INSTALLATION Example of installation: More air is required in hall - shorter run Contents for unit with heater HALL Vent One BEDROOM Vent Two 1 x Fixing kit 1 x Unswitched fuse spur 2 x Mini diffuser 1 x Cable tie 2m x 3m x 100mm Flexi duct Additional contents for unit with heater 1 x Heater enable switch 7 PIV & MIV Loft Mounted Unit SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON: 0345 27 27 810

INSTALLATION INSTRUCTIONS Installations in 3 storey dwellings PIV Loft Mounted Unit Fire Installation Kit For installations in 3 storey dwellings, it is necessary to fit an EnviroVent PIV unit (EVL-W or EVL-H-W) with a fire kit, EnviroVent part number: KIT-PIV-SMOKE. It is important to follow the installation instructions that come with the kit. Smoke alarm For installations in 3 storey dwellings the loft unit should be wired in such a way that it shuts down completely when the smoke alarm system is triggered. This can be done by linking the PIV unit to relay type smoke alarm (N/C), see schematic. When the relay is triggered by the alarm, power to the PIV unit will be interrupted and the unit will stop. When the alarm resets, power will be resumed to the unit and the EnviroVent PIV will resume working at its previous settings. Ø125mm metal fire diffuser Installation checks and maintenance The fire system should be checked at installation to ensure proper function. The diffuser should be periodically checked to ensure they have not been activated and that they are still delivering air into the property. In the case of a fire, the system should be thoroughly checked. MIV Loft Mounted Unit For installations in 3 storey dwellings, it is necessary to fit an EnviroVent PIV unit (EVL-W or EVL-H-W) with a fire kit, EnviroVent part number: KIT-PIV-SMOKE. AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 8

USER GUIDE FOR RESIDENT

USER GUIDE About your EnviroVent PIV & MIV Loft Mounted Unit DO YOU KNOW WHAT S GOING ON IN YOUR OWN HOME? MOISTURE The typical household creates around 100 pints per week - from showers, baths, cooking etc. CHEMICAL EMISSIONS From everyday household furnishings, building products etc. FUMES From tobacco products, exhaust gases etc. DUST From furniture, carpets, bedding etc. = Poor Air Quality = Condensation, Damp & Mould THE CAUSE OF CONDENSATION, DAMP AND MOULD In a dwelling of 4 people, each will contribute approximately 4 pints of moisture per day through showers, boiling kettles, cooking etc totalling over 100 pints of liquid per week. Other airborne contaminants which exist in a typical dwelling like dust, tobacco products, exhaust gases even chemical emissions from furnishing and building products further deteriorate air quality. In older, less energy efficient dwellings, there is a natural escape for this hot, damp problem air through ill-fitting windows and doors, uncarpeted floorboards, lofts without insulation and so forth. Improved building features such as cavity wall insulation, double-glazing and draft proofing prohibit natural ventilation. Stale, humid air is trapped increasing the condensation problem in the dwelling. The Benefits Say goodbye to condensation & mould Whole house ventilation Condensation control Improved air quality Enhanced heat distribution Musty odours removed Benefits allergy and asthma sufferers Streaming windows stopped AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 10

How does my Loft Mounted Unit work? The Loft Mounted Units work by supplying fresh, filtered air throughout the home to transform a stagnant and stale atmosphere into a fresh, healthy and condensation-free environment. The units can deliver air into a home via a single input, usually located in a central landing (PIV Loft) or via twin inputs, located in a central landing and another area of the home (MIV Loft). How does my Loft Mounted Unit help? It prevents the build-up of moisture in the house, controlling steam/condensation during bathing and cooking to prevent the formation of black mould on walls, behind cupboards etc. It will also help to stop general dampness and musty smells caused by poor ventilation. 11 PIV & MIV Loft Mounted Unit SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON: 0345 27 27 810

Energy Saving Benefits Your Loft Units also help to save energy in the following ways: Minimum Energy Consumption Using the latest technology, the units are powered by ultra-low watt motors to achieve low running costs. Solar Gain The units* take maximum advantage of the benefits from solar gain within the loft space. This is the natural accumulation of heat from the sun on bright days. Temperatures in the loft are on average 3 C higher than outside, which results in a relative saving of around 150 Watts per day in an average modern family home. This equates to approximately 10% of annual heating costs. Heat Distribution Warm air accumulates at ceiling level. This air can be up to 7 C higher than the internal air at ground level. By introducing an air supply from the loft space, the Loft Units help to redistribute heat around the home to further reduce heating costs. No need to open windows To reduce humidity and condensation during the heating season, significant energy loss occurs by opening windows. The Loft Units provides fresh, filtered air to the home and reduces humidity without the need to open windows, saving energy and heat loss. Health Benefits: Reduces mould spores, a trigger for respiratory problems and allergies Reduces house dust mite populations by lowering humidity levels - a main trigger for asthma and allergies *except the Inline models How do I control my Loft Unit? The whisper quiet Loft Units operate continuously 24 hours a day. It is important that the unit is not turned off. On auto the flow rate of the unit will be set at the appropriate level for your home during installation. To enable or disable the heater press the heater enable switch on or off. Optional Wireless Switch Models If you have a remote control switch you can change the unit flow rate/speed at any time at the push of a button. You can also use it to enable or disable the heater (see page 6 for operation instructions). AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 12

What features does my Loft Unit have? The intelligent low temperature comfort heater* is designed to temper the air during periods of low external temperatures. It is capable of holding incoming air temperatures accurately at 10 C. With the function enabled, the heater may be on 10% of the time, depending on the fan speed setting and only at loft temperatures at or below 10 C. When the input air temperatures rises above 25 C, the unit will temporarily shut down the supply, to avoid bringing hot air into the property. The units have an automatic increased airflow setting. This function increases airflow rates per setting by 10% to deliver additional air into the property at temperatures above 19 C. *Heater may be omitted on request by the customer. Maintenance The Loft Units have been subjected to rigorous testing and are constructed from durable materials. There should be no requirement for any maintenance within the five year period. At the five year service, the loft filter located on the unit must be replaced to ensure maximum efficiency of the unit. The filter is mounted around the unit with velcro, simply pull off and replace. How much does my Loft Unit cost to run? The Loft Units are very energy efficient. On a constant medium setting with the heater enabled, the unit will cost around 30* a year to run. With the heater disabled the unit will cost less than 6* a year. *Based on an average electricity unit price of 15p. Costs will vary year on year depending on atmospheric conditions and unit settings. Helpful hints and tips Keeping your home condensation free: Try to keep the house as warm as possible for as long as possible Do not dry clothes over any radiators Vent your tumble dryer outside Do not use paraffin / Calor gas type heating Energy bills: To minimise energy bills you may need to adjust the central heating down if the input is in the same room as your thermostat. 13 PIV & MIV Loft Mounted Unit SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT, CALL US ON: 0345 27 27 810

WARRANTY CONDITIONS AND EXCLUSIONS The EnviroVent Loft Mounted Units are covered by a 5 year warranty (7 Year with Rapid Response - PIV only). Do not turn your unit off. It is important that the unit runs continuously. EnviroVent offer customers a full Supply and Fit service. This service also entitles our customers a unique 5 years parts and labour guarantee (7 Year with Rapid Response - PIV only) and if within the 5 years of installation the unit breaks down, we will repair it FREE of charge. Should you buy the fan from an approved wholesaler the product is protected by a 5 years parts guarantee (7 Year with Rapid Response - PIV only) and in the highly unlikely event of any problems you can call our helpline number or return it to the approved wholesaler. Please note that proof of purchase by the way of a receipt is required and that any fans bought from an unapproved source, including but not limited to Ebay, will render the guarantee invalid. What should I do if I have a problem? If, after thoroughly reading this booklet, you feel that your unit is not working correctly, you can telephone the number shown at the bottom of this page (operational from 8:30am to 5:00pm Monday to Friday), and ask for technical assistance. Serial number of the unit We appreciate you choosing this quality EnviroVent product, which is designed and manufactured to the highest specification in Harrogate, North Yorkshire. We are confident that you will be delighted with the performance of the system and the resulting improvement in air quality in your home after the installation of the unit. Your warranty covers any defect or break down that arises due to faulty materials or construction. Terms of Warranty The system must be correctly installed and operated according to the instructions contained in the user guide supplied. Periodic cleaning and maintenance must be carried out by a technically competent person. The warranty will be rendered invalid if the unit is turned off. Turning the unit off can damage it. The warranty does not cover accidental damage, misuse or abuse. The warranty is in addition to your statutory or legal rights. The warranty will only be honoured from approved suppliers. A further 5 year warranty can be obtained subject to the level of service carried out at the 5 year point (7 Year with Rapid Response - PIV only). AFTER INSTALLING THIS UNIT, PLEASE PASS ONTO END USER DO NOT THROW AWAY 14

Delivering innovative and sustainable ventilation solutions worldwide EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate HG2 8PA T / 01423 810 810 F / 01423 301 022 E / info@envirovent.com W / envirovent.com Please read carefully to ensure simple installation and a long trouble free life for the user. AFTER INSTALLING THIS FAN PLEASE PASS ONTO END USER DO NOT THROW AWAY E&OE MKT ENV225-V10-01.03.17 Due to our policy of continuous innovation and improvement EnviroVent reserves the right to alter products specification and appearance without notice. We want to hear from you Your feedback is important to us as we strive to improve our products, services, and overall customer experience. Please email us to help us serve you better: feedback@envirovent.com