Ho-Chunk Gaming THUNDERBIRD ENGINEERING, INC. MILWAUKEE: (414) MADISON: (608)

Similar documents

FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED.

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES


ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

PHOTOS. December 8, 2017

Executive Summary. CNBC Global Headquarters Christine Cajilig

Building Electrical System Overview

Chandler City Hall Chandler, Arizona

SINGLE CONVENIENCE OUTLET, WALL MOUNTED RECESSED +18" AFF

TONY ESPOSITO LIGHTING/ELECTRICAL TECHNICAL REPORT II SEPTEMBER 15, 2011 HUNTER S POINT SOUTH INTERMEDIATE SCHOOL AND HIGH SCHOOL QUEENS, NY

Subcontract Agreement No.

I P. Tough Starters for Tough Environments. Explosion Proof Starter. Ready to Install, Completely Wired and Assembled

Exhibit J. Subcontract Agreement No.

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER

GRILLE, REGISTER AND DIFFUSER SCHEDULE

TABLE LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS ASHRAE Uncovered Parking Areas. Building Grounds. Walkways 10 feet wide or greater

Heat Recovery Units. EXTERNAL STATIC REQUIRED (in.h2o) (Pa) MOTOR (Bhp/Hp) (bkw/kw) SPEED (rpm)

Element D Services Electrical

Electrical Systems Existing Conditions and Building Load Summary Broadway Plaza, Rochester, MN. Appendix A

Note: The office/work area is not in the scope of the PER. Existing Condition

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

GARCIA GALUSKA DESOUSA Consulting Engineers

TRANS ATLANTIC TRADING ENTERPRISE INC.

Technical Report #2. Newseum and Freedom Forum Headquarters. Washington, D.C. Ryan Wise Lighting/Electrical Prof. Dannerth November 2, 2007

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

Prefunctional Checklist

DRAWING SCHEDULE TAB REQUIREMENTS BY EQUIPMENT TYPE TYPE OF EQUIPMENT DESCRIPTION COMPONENT TAB REQUIREMENTS

ULTRA-SAFE Explosion-proof Duct Heaters

Division 26 ELECTRICAL TABLE OF CONTENTS

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

ULTRA-SAFE Explosion-proof Duct Heaters

MONROE MIDDLE SCHOOL SCHOOL

Renovate MCRC Facilities Great Lakes, IL

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

SOUTHVIEW MEDICAL CENTER

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

Lindsay Frederick. Lighting + Electrical. Ron Dodson Faculty Advisor. Native American Cultural Center Arizona. Technical Report 2

Technical II Report Electrical Systems

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

MEDICAL OFFICE BUILDING

SECTION : MEPS IDENTIFICATION & LABELING

Direct Gas-Fired Make-Up Air

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM.

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY

GENERAL CONTRACTOR NOTES GEN WALK-IN NOTES 1. E.C. TO VERIFY EXACT SIZE & LOCATION OF COMPRESSORS FOR WALK-IN BOXES W/ KEC & ARCHITECT.

DRY AND PRE-ACTION SYSTEM INSPECTOR'S TEST DRAIN DETAIL

Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram

INDEX. Page 2 to 7 Electrical Specifications. Page 8 Electrical Schemes: Basement Plan. Page 9 Electrical Schemes: First Floor Plan

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

Electrical Safety Through Design. Mersen EP formerly Ferraz Shawmut

Spring Test 6 due 04/26/2013

1. Please see the attached document as it applies to North Central high School Classroom Addition Project. End of Addendum No. 15

B. Section Transfer Switches: Automatic transfer switch.

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Newark, Delaware Architectural Engineering Senior Thesis Portfolio. Electrical Analysis

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

NYC Department of Education

SECTION : FIRE ALARM & DETECTION SYSTEMS

Corbin Building. Technical Assignment 2. Matthew Trethaway Lighting/ Electrical AE 481W 10/26/2011 Advisor: Ted Dannerth

SECTION LIGHTING CONTROLS

CONNECTICUT. Downloaded

Replacement of Fire Pump and Generator Upgrade, H Building, Sexton Campus

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

UNIVERSITY OF PENNSYLVANIA NEURAL AND BEHAVIORAL SCIENCES BUILDING 415 University Ave, Philadelphia, PA 19104

Providing Comfort Through Efficient Energy Solutions PRICE BOOK (USD) - LIST EFFECTIVE JUNE 1,

Machinery Room Electrical Best Practices

TOWER IQ Stand Alone or Building Automation Controlled Options Scalable to meet any application Energy Saving VFDs

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION

Fluid Cooler Fan and Pump control panel

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

DANFOSS OPTYMA PLUS INVERTER UNITS

Electrical System (N) PANELBOARD "L1" VOLTAGE: 208/120 A, 3P :MAIN C/B PHASE: 3 A :BUSSING WIRE: 4 :MOUNTING

HVAC HEATING PRODUCTS

Indirect Gas-Fired Make-Up Air

SECTION STEAM CONDENSATE PUMPS

Digital Inverter 4 series 8 & 10HP

Chapter 1 General... 5

AVPTC Multi-Position, Internal Txv

Sprecher + Schuh Motor Control and Protection Products

NOTICE TO ALL FIRMS. Bid RFI Questions and Answers

AGORA PALM UNIT TYPE A2, A2A, A2B, A2C, A2D, A2F, A2G, A2H, A2J UNIT TYPE A1 & A1-A UNIT TYPE A3-A, A3B, A3C, A3E, A3F, A3H UNIT TYPE A4, A4A

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

YourRepair Home & Boiler Cover

A WORD ABOUT PORTABLE ELECTRIC GENERATORS

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E

JH Series Installation

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Technical Assignment 3 11/15/04. Executive Summary

AVPTC Multi-Position, Internal Txv

SHOE PALACE HUNTINGTON PARK M.200

Job Name Control Systems Description Date

THERMOSTATS & CONTROLS

GA Gas Unit Heater Assemblies Technical Guide

Transcription:

Ho-Chunk Gaming

POWER SYMBOLS X ELECTRICAL PANEL - REFER TO DRAWINGS FOR WIDTH AND PANEL SCHEDULES PANEL NAMING: XXP-#X: DENOTES PANEL FUNCTION: L = LIGHTING P = GENERAL POWER E = EMERGENCY S = OPTIONAL STANDBY C = CRITICAL LOADS A AFF AFG AMP ATS AMP ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMPLIFIER AUTOMATIC TRANSFER SWITCH GC GEN GFI GRD H, HV PROJECT GENERAL CONTRACTOR GENERATOR GROUND FAULT INTERRUPTER TYPE GROUND HEATING/VENTILATING CONTRACTOR PCL# PBL PBS PC PL PRV PHOTOCELL, # INDICATES PHOTOCELL DESIGNATION PUSH BUTTON WITH PILOT LIGHT PUSH BUTTON STATION PLUMBING CONTRACTOR PILOT LIGHT POWER ROOF VENTILATION XXP-#X: DENOTES VOLTAGE: H = 480Y/277V L = 208Y/120V XXP-#X: DENOTES FLOOR PANEL IS ON (1, 2, 3...) XXP-#X: DENOTES WHICH PANEL ON FLOOR (A, B, C...) BFG C CB, C/B CD BELOW FINISHED GRADE CONDUIT CIRCUIT BREAKER(S) CANDELA HOA HP IG IU HAND/OFF/AUTO SELECTOR SWITCH HORSEPOWER ISOLATED GROUND IN UNIT R RAF RAI RD RECEPTACLE RETURN AIR FAN REMAIN AS IS REMOVE EXISTING AND DISPOSE OFF SITE DP/X MSB INV/X DISTRIBUTION PANELBOARD - REFER TO DRAWINGS FOR WIDTH AND PANEL SCHEDULES MAIN SWITCHBOARD - REFER TO DRAWINGS FOR DIMENSIONS AND ONE LINE DIAGRAM BATTERY INVERTER - REFER TO DRAWINGS FOR WIDTH AND INVERTER SCHEDULES CEF CF CKT CM CO CEILING EXHAUST FAN COMBINATION FUSIBLE FULL VOLTAGE STARTER CIRCUIT CONSTRUCTION MANAGER CARBON MONOXIDE JB KS KVA JUNCTION BOX KEY SWITCH KILOVOLT-AMPERES RESD RVS SB SF REMOVE EXISTING; SAVE AND/OR DISPOSE OFF SITE (OWNER'S OPTION) REDUCED VOLTAGE STARTER SOUNDER BASE SUPPLY FAN T T/X ELECTRICAL PANEL - REFER TO DRAWINGS FOR DIMENSIONS AND ONE LINE DIAGRAM CPT CS CONTROL PANEL TRANSFORMER COMBINATION STARTER KW KILOWATT SPD SPS SURGE PROTECTION DEVICE SELECTOR SWITCH MCC/X J J M TCP VFD CB TC UPS M SPD ATS MOTOR CONTROL CENTER - REFER TO DRAWINGS FOR DETAILS NON-FUSED DISCONNECT SWITCH FUSED DISCONNECT SWITCH MOTOR STARTER COMBINATION MOTOR STARTER-DISCONNECT MANUAL MOTOR STARTER W/ THERMAL OVERLOAD SPECIAL OUTLET - SEE SPECIAL OUTLET SCHEDULE JUNCTION BOX - FLOOR / CEILING MOUNTED JUNCTION BOX - WALL MOUNTED MOTOR MOTORIZED DAMPER TEMPERATURE CONTROL PANEL VARIABLE FREQUENCY DRIVE SURGE PROTECTIVE DRIVE ENCLOSED CIRCUIT BREAKER TIME CLOCK UNITERRUPTIBLE POWER SUPPLY AUTOMATIC TRANSFER SWITCH NOTE: ALL SYMBOLS MAY NOT BE USED FOR THIS PROJECT CU CUH D, DS DD DM DN DP DRWGS EC EDH EF EM EP ERL ET ETR EUH EWH CONDENSING UNIT CABINET UNIT HEATER DISCONNECT SWITCH DOUBLE DUPLEX DOOR MANUFACTURER DOWN DISTRIBUTION PANELBOARD DRAWINGS BY ELECTRICAL CONTRACTOR ELECTRIC DUCT HEATER EXHAUST FAN EMERGENCY EXPLOSION PROOF EXISTING TO BE RELOCATED ELAPSED TIMER EXISTING TO REMAIN ELECTRIC UNIT HEATER ELECTRIC WALL HEATER LD LS LV LVC LVT MAG MC MCA MCB MCC MD MFR MLO MR# MS MSB MTD NFD LOAD (KW OR HP) LIFE SAFETY LOW VOLTAGE LOW VOLTAGE CONTRACTOR LINE VOLTAGE THERMOSTAT (120V) MAGNETIC STARTER MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MOTORIZED DAMPER MANUFACTURER MAIN LUGS ONLY MULTI-RECEPTACLE, # INDICATES MULTI-RECEPTACLE DESIGNATION MANUAL STARTER MAIN SWITCHBOARD MOUNTED NON-FUSIBLE DISCONNECT SWITCH SS SSP SVS SWBD SWGR T, XFMR T-STAT TC TCC TCP TL# TS TV TYP UFD UG UGD UH SOFT START START-STOP WITH PILOT LIGHT SUPERVISORY SWITCH SWITCHBOARD SWITCH GEAR TRANSFORMER THERMOSTAT TIME CLOCK TEMPERATURE CONTROL CONTRACTOR TEMPERATURE CONTROL PANEL TRACK LIGHT, # INDICATES TRACK LIGHT DESIGNATION TAMPER SWITCH TELEVISION TYPICAL UNDERFLOOR DUCT UNDERGROUND UNDERGROUND DUCT UNIT HEATER EX EXISTING NIC NOT IN CONTRACT UOI UNLESS OTHERWISE INDICATED NL NIGHT LIGHT - 24 HOUR OPERATION UPS UNINTERRUPTIBLE POWER SUPPLY FB FURNISHED BY NP NEAR PUMP (REFER TO HVAC & PLUMBING DRAWINGS FOR EXACT LOCATION) USS UNIT SUBSTATION FC FOOTCANDLE NTS NOT TO SCALE FD FUSIBLE DISCONNECT SWITCH NU NEAR UNIT (REFER TO HVAC & PLUMBING DRAWINGS FOR EXACT LOCATION) V VENDOR SUPPLYING EQUIPMENT FLA FULL LOAD AMPS FS FLOW SWITCH OOS ON/OFF SWITCH W WATTS FZS FREEZE STAT OU ON UNIT W/ WITH WP WEATHERPROOF WR WEATHER RESISTANT NOTE: ALL ABBREVIATIONS MAY NOT BE USED FOR THIS PROJECT NOTE: ALL ABBREVIATIONS MAY NOT BE USED FOR THIS PROJECT NOTE: ALL ABBREVIATIONS MAY NOT BE USED FOR THIS PROJECT SHEET INDEX E-1 E-2 E-3 E-4 ELECTRICAL SYMBOLS AND ABBREVIATIONS OVERALL FLOOR PLAN PROPOSED ELECTRICAL SINGLE LINE - MAIN ELECTRICAL ROOM & ELECTRICAL ROOM X1805 ELECTRICAL ROOM ELEVATIONS & FLOOR PLANS - ROOM X1659 & T3 ELECTRICAL ROOM FLOOR PLANS - MAIN ELECTRICAL ROOM & X1805