GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

Similar documents
GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

AMVM97 (B) / ACVM97 (B)

ComfortNet -Compatible

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

GMH95/GCH9 MULTI-POSITION, DUAL$AVER CONVERTIBLE, MULTI-SPEED GAS FURNACE

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

TECHNICAL MANUAL. GMH95 40" 95% Gas Furnace

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

GMS9/GCS9 SERIES 93% AFUE

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units

AVPTC. Air Handlers 1½ to 5 Tons

GKS9 40" 90% Gas Furnaces

TECHNICAL MANUAL. ACVC9/AMVC95 GCVC9/GMVC95 90% UP TO 96% Gas Furnace Units

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

AVPTC Multi-Position, Internal Txv

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

AVPTC. Air Handler 1½ to 5 Tons

TECHNICAL MANUAL. GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

FG7T (C and L Series)

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

RG7D 1-Stage Heat Series

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

TECHNICAL SPECIFICATIONS

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

TECHNICAL MANUAL. GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

MBR. Multi-Position. Modular Blower

Technical Information

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

T9MPV SmartComfort VS90 Product Specifications

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

TECHNICAL SPECIFICATIONS

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Upflow/Horizontal Condensing, Gas-Fired Furnace

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price

Wt. Lbs Model Number (BTUH) Hz

Cooling Capacity CFM in. w.c. (125 Pa)

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

TECHNICAL INFORMATION MANUAL

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

MULTI POSITION GAS FURNACE

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Cooling Capacity CFM in. w.c. (125 Pa)

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Downflow/Horizontal Right Induced Draft Gas Furnace

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

G6RC Series TECHNICAL SPECIFICATIONS

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

40 Residential Gas Furnace Operation

Rheem Classic Series Multi-position Gas Furnaces

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

Transcription:

(B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Data... Wiring Diagrams... 0 Standard Features Integrated communicating omfortbridge Technology ommissioning and diagnostics via on board Bluetooth with the oolloud phone and tablet application Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Two-stage gas valve provides quiet, economical heating Durable Silicon Nitride igniter Quiet two-speed induced draft blower ompatible with any single-stage thermostat Self-diagnostic control board with constant memory fault code history output to a triple 7-segment display olor-coded low-voltage terminals with provisions for electronic air cleaner Efficient and quiet variable-speed airflow system gently ramps up or down according to heating or cooling demand Multiple continuous fan speed options offer quiet air circulation Auto-omfort and enhanced dehumidification modes available All models comply with alifornia 0 ng/j Low x emissions standard For installation in alifornia s South oast Quality Management District (SAQMD) only: This furnace does not meet the SAQMD Rule ng/j x emission limit, and thus is subject to a mitigation fee of up to $0. This furnace is not eligible for the SAQMD lean Furnace Rebate Program: www.leanfurnacerebate.com. abinet Features Designed for multi-position installation upflow, horizontal left or right ertified for direct vent (-pipe) or non-direct vent (-pipe) Easy to install top venting with optional side venting onvenient left or right connection for gas and electrical service abinet air leakage (QLeak) % Heavy-gauge steel cabinet with durable baked-enamel finish Fully insulated heat exchanger and blower section tight solid bottom or side-return with easy-cut tabs for effortless removal in bottom air-inlet applications * omplete warranty details available from your local dealer or at www.goodmanmfg. com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 0-Year Unit Replacement Limited Warranty and 0-Year Parts Limited Warranty, online registration must be completed within 0 days of installation. Online registration is not required in alifornia or Québec. SS- www.goodmanmfg.com 0/8 Supersedes 9/8

Nomenclature G M V 9 00 B N **, 7,8,9 0, Brand G - Goodman Brand Engineering Major / Minor Revisions * Not used for inventory control. onfiguration x M - Upflow/Horizontal N - Low x - Downflow/Horizontal abinet Width Motor B - 7½ - " V - Variable Speed EM/omfortBridge D - ½" E - Multi-Speed EM S - Single Speed Maximum FM - 800 FM - 00 FM Gas Valve - 00 FM - 000 FM M - Modulating - Two- Stage MBTU/h S - Single Stage 00-0,000 BTU/h 00-0,000 BTU/h AFUE 0-0,000 BTU/h 97-97% AFUE 9-9% AFUE 9-9% AFUE Accessories Model Description 00BNB 00BNB 080BNB 080NB 00NB 00DNB VENT- oncentric Vent Kit (") --- VENT- oncentric Vent Kit (") RF000 Drain Kit -Horizontal Left Vertical Flue EFR0 External Filter Rack with "x" Permanent Filter 070K00000S Flush Mount Vent Kit - " or " 070K0000S Flush Mount Vent Kit - " --- 0DNB HASFK High-Altitude Natural Gas Kit HASFK- HASFK- HASFK- HASFK- HASFK- TBD HASFK- HASFK High-Altitude LP Gas Kit HASFK- HASFK- HASFK- HASFK- HASFK- TBD HASFK- LPLP0 Low LP Gas Pressure Switch LPM-08 LP onversion Kits www.goodmanmfg.com SS-

Product Specifications 00BNB 00BNB 080BNB 080NB 00NB 00DNB 0DNB Heating Data High Fire Input¹ 0,000 0,000 80,000 80,000 00,000 00,000 0,000 High Fire Output¹ 8,00 7,00 7,800 7,800 9,000 9,000,00 Low-Fire Steady-State Input¹ 8,000,000,000,000 70,000 70,000 8,000 Low-Fire Steady-State Output¹,880 0,0,70,70 7,00 7,00 80,0 AFUE² 9 9 9 9 9 9 9 Temperature Rise Range ( F) 0-0 - - - - 0-0 - Vent Diameter³ " - " " - " " - " " - " " - " " - " " - " No. of Burners irculator Blower Available A @ 0." ESP. -. -. -. - - - - Size (D x W) 0" x 8" " x 8" " x 8" " x 0" " x 0" " x " " x " Horsepower @ 07 RPM ½ ½ ½ ¾ Speed VS EM VS EM VS EM VS EM VS EM VS EM VS EM Electrical Data Min. ircuit Ampacity⁴ 7.8 7.8 7.8 0.... Max. Overcurrent Device (amps)⁵ 0 0 0 Shipping Weight (lbs) 7 0 ¹ Natural Gas BTU/h ² DOE AFUE based upon Isolated ombustion System (IS) ³ Installer must supply one or two PV pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either " or " in diameter, depending upon furnace input, number of elbows, length of run and installation ( or pipes). The optional ombustion Pipe is dependent on installation/code requirements and must be " or " diameter PV. ⁴ Minimum ircuit Ampacity = (. x irculator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HAR-type circuit breakers of the same size as noted. Notes All furnaces are manufactured for use on VA, 0 Hz, single-phase electrical supply. Gas Service onnection ½" FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical ode and/or all existing local codes. For bottom return: Failure to unfold flanges may reduce airflow by up to 8%. This could result in performance and noise issues. For servicing or cleaning, a " front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. SS- www.goodmanmfg.com

Dimensions Discharge Discharge 8¾ Intake " Pipe Left-Side Drain Trap Exterior Holes ½ ¾ ⅝ enter Dimple For Alternate Intake Pipe " OD Hole High-Voltage Standard Gas Supply Location A B ⅞ ¾ ¾ Vent/ Flue Pipe " PV Right-Side Drain Trap Exterior Holes High-Voltage Alternate Gas Supply ½ 9½ Alternate Vent/ Flue Location ¾ ½ ½ 9¼ 9⅝ ⅞ ⅞ ½ ⅛ 9⅝ 9¼ ⅜ LEFT SIDE VIEW Low-voltage ⅞ ⅜ ½ ondensate Drain Trap Exterior onnection (Right or Left Side) ¾ PV FRONT VIEW D Unfolded Flanges E Folded Flanges ⅞ Low-Voltage ⅞ ⅜ ½ RIGHT SIDE VIEW Unfolded Flanges ½ Folded Flanges Minimum learances to ombustible Materials Discharge Model W D H A B D E Return 00BNB 7½" 8⅞" ½" 7½" " ⅞" ⅛" ⅝" 00BNB 7½" 8⅞" ½" 7½" " ⅞" ⅛" ⅝" 080BNB 7½" 8⅞" ½" 7½" " ⅞" ⅛" ⅝" 080NB " 8⅞" ½" " 9½" 7⅞" " 7½" 00NB " 8⅞" ½" " 9½" 7⅞" " 7½" 00DNB ½ 8⅞ ½ ½" " 0⅞" 9⅜" 0⅞" 0DNB ½" 8⅞" ½" ½" " 0⅞" 9⅜" 0⅞" Position Sides Rear Front Bottom Flue Top Upflow 0" 0" " 0" " Horizontal " 0" " 0" " = If placed on combustible floor, the floor MUST be wood ONLY. Minimum Filter Sizes 00BNB 00BNB 080BNB 080NB 00NB 00DNB Filter Size (in²) (Qty) () x (side or bottom) () 0 x (bottom) or () x (side) Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located. 0DNB www.goodmanmfg.com SS-

flow Data MODEL/TEMP RISE RANGE (MID RISE) 00BNB* 0-0 () 00BNB* - (0) 080BNB* - (0) 080NB* - (0) 00NB* - (0) 00DNB* 0-0 () 0DNB* - (0) FM RISE FM RISE FM RISE FM RISE FM RISE FM RISE FM RISE Recommended cfm for high heat / expected temperature rise Lowest recommended cfm for hi heat / expected temperature rise Maximum cfm for hi heat / expected temperature rise 00 07 0 00 0 70 0 770 0 980 0 0 70 0 80 090 00 0 80 0 0 00 00 8 0 70 0 00 0 00 0 00 8 TE: Low Heat FM = High Heat FM X.7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise ± % 00F00-A 00BNB* ooling Speed ( @. -.8 w.c. ESP) FM 00BNB* ooling Speed ( @. -.8 w.c. ESP) FM. 00 0. 00 0 800 0 800 0.,000 700.,000 700,00 80,00 80 MAX,00 MAX,00 080BNB* ooling Speed ( @. -.8 w.c. ESP) FM 080NB* ooling Speed ( @. -.8 w.c. ESP) FM. 00 0 800 0 800 0.,000 700.,000 700,00 80,00 80,00 0 MAX,0 MAX,70 00NB* ooling Speed ( @. -.8 w.c. ESP) FM 00DNB* ooling Speed ( @. -.8 w.c. ESP) FM 800 0 800 0,00 80,00 80,00,0,00,0,000,00,000,00 MAX,00 MAX,00 0DNB* ooling Speed ( @. -.8 w.c. ESP) FM 800 0,00 80,00,0,000,00 MAX,00 All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 00 FM per ton when cooling is desirable. Do not operate above. w.c. ESP in heating mode. Operating FM between. and.8 w.c. is tabulated for cooling purposes only. SS- www.goodmanmfg.com

HUM DEHUM Wiring Diagram GR YL BR TES: HOT SURFAE IGNITER IRUIT ONNET EM MTR HARNESS TWO STAGE GAS VALVE (ITE-RODGERS) LOW FIRE PRESSURE SWITH. SET HEAT ANTIIPAT ON ROOM THERMOSTAT AT 0.7 AMPS.. MANUFATURER'S SPEIFIED REPLAEMENT PARTS MUST BE USED EN SERVIING. BR AU RESET PRIMARY GN ONTROLS (SINGLE ONTROL ON LIMIT ONTROL HI PM MANUAL RESET ROLLOUT LIMIT BURNER OMPARTMENT 0 kbtu) OWER OMPARTMENT AU RESET AUXILIARY LIMIT ONTROL ONDENSATE SWITH (OPTIONAL) 0 IN 7 OUT EM FUSE A IRULAT OWER ID OWER TWO-STAGE PRESSURE GR SWITH ASSEMY FRONT OVER PRESSURE SWITH. IF ANY OF THE IGINAL WIRE AS SUPPLIED WITH THE FURNAE MUST BE REPLAED, IT MUST BE REPLAED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 0$. USE OPPER ONDUTS ONLY.. UNIT MUST BE PERMANENTLY GROUNDED AND ONFM N.E.. AND LOAL ODES. YL 8 9 ONDEN -SATE UEOTH BOA FS LINE R INDUED OWER DRAFT EA IGN-N IND-N IND-LO IND-HI IGN ENTER LEFT RIGHT RAT NA SAT R G W Y DE INDUT OIL (ON SOME MODELS) HIGH FIRE PRESSURE SWITH BR BR YL 0 VA TRANSFMER OL ODES: PINK BR BROWN ITE UE GRAY RED YL YELLOW ANGE RPLE GN GREEN AK FLAME SENS GN VA VA JUNTION BOX HASSIS GROUND OWER OMPARTMENT DO SWITH (OPEN EN DO OPEN) INTEGRATED ONTROL MODULE V THERMOSTAT ONNETIONS WIRING UNIT R Y VA/ Ø /0 HZ POWER SUPPLY WITH W G R WARNING: GROUNDED. FUSE A MIRO MIRO OVERURRENT PROTETION DEVIE DISONNET POWER BEFE SERVIING. MUST BE PROPERLY POLARIZED AND DO SWITH INDUT OIL (ON SOME MODELS) LINE LINE LOW VOLTAGE (V) LOW VOLTAGE FIELD HI VOLTAGE (V) HI VOLTAGE FIELD JUNTION EA IGN +VD TERMINAL INTERNAL INTEGRATED ONTROL PLUG ONNETION DISONNET FS TH () AU RESET AUXILIARY LIMIT ONTROLS HLO (0) PSO (7) PS () PS () HLI () MVL () () TR () HIGH FIRE PRESS. SWITH MVH () MV (8) () + VD () RX () TX () IND HI INTEGRATED ONTROL MODULE L JUNTION BOX IND LO HLI () HLI () INDO AIR IRULAT WR ELETRONI AIR LEANER L N ID WR HOT SURFAE IGNITER FLAME SENS VA/ Ø /0 HZ POWER SUPPLY WITH OVERURRENT PROTETION DEVIE VA VA WARNING:DISONNET POWER BEFE SERVIING. WIRING UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. INDO AIR IRULAT WR N 0 VA TRANSFMER MANUAL RESET ROLLOUT LIMIT ONTROLS FRONT OVER PRESSURE SWITH FIELD FIELD SPLIE DISONNET EQUIPMENT SWITH (TEMP.) IGNITER SWITH (PRESS.) OVERURRENT PROT. DEVIE AU RESET PRIMARY LIMIT ONTROL LOW FIRE PRESS. SWITH PM HI GAS VALVE INTEGRATED ONTROL MODULE High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. 00F00- Goodman Manufacturing ompany, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 08 Goodman Manufacturing ompany, L.P. Houston, Texas www.goodmanmfg.com SS-