Energy Efficient Easy to Install Extended Service Life. Vertical Direct Drive Blower Coils

Similar documents
DIRECT DRIVE BLOWER COILS

BUILD YOUR REPUTATION ON OURS. Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG

Vertical V*B Series Fan Coil Technical Catalog

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

FCC Fan-Coil Units High-Performance, Vertical

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

SSL & SBS Engineering Guide

PRODUCT CATALOG BLOWER COILS.

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

C13-Series Engineering Guide

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

VertiCool Aurora Engineering Guide

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

VariCool VAV Engineering Guide

catalog CDV Fan-Coil Units High-Performance, Vertical

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Energy Efficient Easy to Install Extended Service Life. Vertical Direct Drive Blower Coils INSTALLATION, OPERATIONS AND MAINTENANCE MANUAL

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

SKYPAK II, 3 Ton Series, gives you a

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

Product Specifications. Vertical Floor Consoles By First Co.

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

SKYPAK II, 3 Ton Series, gives you a

Product Data. Fig. 1 - Unit 50VR -A

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

PAJ3. Product Specifications

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Water-Cooled Self-Contained Units

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

Q-TEC QC-Series Chilled Water Air Conditioner

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

CWA4 Chilled & Hot Water Fan Coil

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

Bosch BVA Series Air Handler

RGE 13 A T - 1 A

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

Q-Tec TM QC-Series Chilled Water Air Conditioner

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

GREEN REFRIGERANT R-410A

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

MERIT Series R-410A - Upflow / Horizontal

VERTICAL FAN COIL UNITS

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

MAC-120HE-03 Air-Cooled Chiller

High Heat COP. High/Low Stage

engineering guide FN Fan-Coil Units High-Performance, Horizontal

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

technical guide Water-Cooled Self-Contained Units

MERIT Series R-410A - Upflow / Horizontal

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

MERIT SERIES Up Flow / Horizontal

13 GEP A L P - 1 A

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

WALL-MOUNT HEAT PUMPS - (60HZ)

SECTION CONVECTION HEATING AND COOLING UNITS

Product Data FEATURES/BENEFITS. 524J PACKAGED AIR -HANDLING UNITS WITH PURONr REFRIGERANT SIZES 07, 08, 12, 14, 16. Indoor air quality features

Energy Efficient Easy to Install Extended Service Life. Horizontal Direct Drive Blower Coils

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

WJH4 Product Specifications

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Transcription:

Energy Efficient Easy to Install Extended Service Life Engineered to save our customers money Eliminate the belt and pulleys Energy efficient EC Motor Improve indoor air quality Nominal CFM range of 00 to 3,000 CFM

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils

Table of content 3 Table of Contents -5 Features and Benefits -7 Unit Nomenclature 8 Nominal Capacity and Listing 9- Cooling Capacity Tables -5 Heating Capacity Tables Component Static Resistance Table 7 Sound Power Data 8- Fan Curves -3 Physical Data -5 Piping Stub-Out Location Electric Heaters Availability, Single Phase 7 Electric Heaters Availability, Three Phase 8 Motor Data 9 Factory-Installed Options 30 Distributed Weight Calculations 3 Filters 3-33 Options - Mixing Box 3 Serial Plate example International Environmental Corporation (IEC) works continually to improve its products. As a result, the design and specifications of each product may be changed without notice and may not be as described herein. Please contact IEC for information regarding current design and product specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties but are merely IEC s opinion or commendation of its products. Manufacturer s standard limited warranty applies. 3 3

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils Direct Drive Blower Coils Meet the Versatile Needs of Our Customer These compact blower coils are ideally suited for a variety of ducted applications that require a range of 00 to 3000 CFM, capacities between.5 tons to 9 tons, and generally rated for applications up to.5 w.g of total static pressure. These units provide comfort cooling and heating while offering a broad range of application flexibility between the traditional fan coil unit and a central station air handling unit. Several configurations are available to meet the needs of different climates and applications. The Direct Drive units can be ordered as: -pipe system -pipe system with electric heat -pipe system Direct expansion system cooling Direct expansion cooling with electric heat Direct expansion cooling with hot water heating VDY units are floor-mounted and have a small footprint, allowing fit through a standard 3 door. HDY/VDY are available with left- or right-hand arrangements for design flexibility. Standard Features Variable speed EC Motors (/ HP to 3 HP with built-in thermal overload protection) provides energy savings, quiet operation and easy field adjustment. The motor/ blower assembly is easily removable for fast and efficient maintenance Double-sloped stainless-steel drain pan eliminates water accumulation to prevent mold growth Removable design for easy cleaning Three-sided tool-less filter access with magnetic panels and large size cabinet access panels make routine maintenance fast and efficient. Small footprint allows installation in variety of building constructions and applications Galvanized steel heavy gage cabinet construction enhances unit durability duct collar enables quick field installation Durable filter rack designed to accept, or filters for better IAQ Forward curved, statically and dynamically balanced fans for quieter unit operations Left or Right Hand arrangements for installation and design flexibility Options Variety of heating and cooling coil configurations offer flexibility to meet comfort requirements for most applications Double wall construction provides an easy-to-clean durable surface. Solid or perforated, it helps to reduce case-radiated sound in ducted applications and protects from water and mechanical damage Fully assembled mixing box with low-leak dampers supports outside air ventilation requirements MERV 8 and MERV 3 filter options up to media provide greater IAQ Electric heaters are factory mounted and ETL/cETL certified as an assembly Condensate float switch to prevent leaks and water damage Interlocking disconnect switch to shut off power when an emergency occurs

Standard Vertical Direct Drive Blower Coil Features Eliminating the belt reduces install time, parts and maintenance Efficient EC Motor reduces operating costs: Soft start performance reduces the inrush current 3 speed operation allows the fan to run at low speed during light load conditions No belt squeal Soft start motor performance gradually increases fan speed Removable double-sloped stainless steel drain pan eliminates water accumulation Mixing box option circulates in outside fresh air Your Benefit Reduce Costs Experience Quieter Operation Improve Indoor Air Quality Applications Where the application calls for cooling capacities or external static pressures that can not be met with standard or high performance direct drive fan coil units; use an IEC vertical direct drive blower coil. Application Fit Vertical configuration, with 8 different sizes meet a multitude of room layouts and ventilation needs Wide variety of coil options Large Public Areas These units are ideal for applications with a large common area such as restaurants, airports, sports arenas, stadiums, private boxes, gymnasiums, exercise areas, locker rooms, atriums and foyers, auditoriums, shopping malls, equipment or mechanical rooms, and casinos, to name a few. Quality and Safety Every unit tested and inspected at the factory for trouble-free startup Optional condensate float switch Motors have built-in thermal overload protection Optional Interlocking Disconnect Switch ETL and cetl listed Operating Limitations The fan curves outline the airflow and static pressure range where it is acceptable to run these units. On units with electric heat, the minimum airflow shown on the operating envelope must be maintained to prevent electric heat nuisance trips. Installation Considerations (Reference IOM for details) The VDY units are typically installed in a closet or mechanical room. Attention should be paid to have enough clearance around the units for service and maintenance. Units are installed on a pad. Ensure that you have adequate pad height for proper trapping of the condensate drain. Acoustical Considerations With sound becoming more of a concern to design engineers, building owners and occupants, proper consideration should be given to the selection and placement of these units. To further reduce the sound level, additional measures can be taken. Some examples include: using flexible duct connectors lining the main supply and return ducts with acoustical absorption material placing the return air grilles as far away from the unit as possible. 5 5

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils UNIT SIZE 0 00 CFM 08 800 CFM 0 000 CFM 00 CFM 00 CFM 0 000 CFM 00 CFM 30 3000 CFM CABINET OPTIONS Drain Pan AS Double Slope Stainless Steel Filter Options C sets of throwaway F Pleated MERV 8 G Pleated MERV8 M MERV with pleated pre-filter U MERV W MERV 3 Insulation C* Closed Cell W Standard Fiberglass S* Premium IAQ Fiberglass (Edges Sealed) G* Foil Face (Edges Sealed) *C, S & G not allowable w/ Double-Wall Mixing box N Front & Top Entering Air comes Standard with Single-blade Dampers Walls Construction Y Single-Wall (Standard) A Double-Wall Construction (Solid Liner) B Double-Wall Construction (Perforated) UNIT NOMENCLATURE COIL Rows BY KY LY 8 B / B7 / K / K7 / PY row DX GY Row DX P row heating (pre-heat position) & row DX G row heating (pre-heat position) row DX 7P row heating (pre-heat position) row DX 7G row heating (pre-heat position) row DX QY row DX 0A FY Row DX 0A Q row heating (pre-heat position) and row DX 0A F row heating (pre-heat position) row DX 0A 7Q row heating (pre-heat position) row DX 0A 7F row heating (pre-heat position) row DX 0A Total rows allowed is 8. Hand R L Right-hand Coil Connections Left-hand Coil Connections Standing in front of the unit facing the filter, hand is determined by looking into the air supply and assigning the hand to match the location of the cooling coil connections. Material(Tube/Fin/Coatings) Y Aluminum Fins w/ Galvanized Wrap S Aluminum Fins w/ Stainless Steel Wrap C Copper Fins with Stainless Steel Wrap

Accessories - Vents/Drains Y MAV(Std) A AAV(-Pipe) B AAV(-Pipe) C MAV w/ Drain (-Pipe) D MAV w/ Drain (-Pipe) E AAV w/ Drain (-Pipe) F AAV w/ Drain (-Pipe) MAV - Manual Air Vent AAV - Automatic Air Vent Accessories - TXV T TXV Valve (DX Only) Y None EC MOTOR Motor-Voltage/Phase/Hertz C 5//50-0 D 08//50-0 E 30//50-0 F 77//50-0 N 08/3/50-0 P 30/3/50-0 G 0/3/50-0 Horsepower C / HP E HP F.5 HP (Three Phase only) H 3 HP (Three Phase only) Motor Type M EC Motor, no board (0-0 VDC) N EC Motor, POT board, 3 discrete speeds ELECTRIC HEAT Heater Voltage Y None F 77//0 C 0//0 N 08/3/0 D 08//0 P 0/3/0 E 0//0 G 80/3/0 Heater Kilowatt Y None BY.0 EY.5 GY CY.5 FY 3 GA.5 DY FA 3.5 HY 5 JY PY NL 8 KY 7 QY RY 9.9 LY 8 NH 5 RH 5 NY 9.9 NJ SY 30 Note: Voltage rules required, motor & heater voltage must match. Dual power source is not available. Heater Stage Y None A -Stage, Single-Phase (- kw) B -Stage, Single-Phase (3- kw) C -Stage, 3-Phase (-30 kw) D -Stage, 3-Phase (-30 kw) E 3-Stage, 3-Phase (-30 kw) Rules apply for stages Applications BAY BA3Y BAJ BA3J BPR BP3R CONTROLS BPK BPH BPL BP3K BP3H BP3L st Digit is Control Voltage (B= volt); nd Digit is Type of Control (A=Motor Controls;P=Electric Heat & Motor Controls);Third Digit is Phase (=Single Phase;3=3 Phase);th Digit is Fusing and Disconnect (Y=Std. V Control Fusing and No Disconnect; J=Y plus 0 amp Disconnect; R=Std. V Control Fusing and Heater Fusing, No Disconnect; K=R plus 0 amp Disconnect; H=R plus 0 amp Disconnect; L=R plus 80 amp Disconnect (All electric heat includes thermal limit switch) Special Controls O Overflow Condensate Switch Low Voltage Package V 3-Speed Adjustable (Default) W Proportional (requires 0-0 VDC controller) 7 7

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils AHRI Certification IEC s Vertical Direct Drive Blower Coil units are certified in compliance with Air-Conditioning, Heating, and Refrigeration Institute (AHRI) industry standard AHRI-0 for room fan coil units. Approved standard ratings are tabulated below. Nominal Capacity Range Model Unit Size Coil Rows Nominal CFM VDY C-ETL-US Listing IEC s Direct Drive Series blower coil units are listed by Intertek Testing Services (ITS). ITS s C-ETL-US listing signifies that IEC s blower coil units have been examined by ITS and comply with the minimum requirements of U.S. and Canadian national product safety standard, UL 995/CSA C. No. 3, and that IEC s manufacturing site has been audited. ITS s re-examination service includes periodic visits to IEC s factory to ensure continued compliance for all listed products. Water Pressure Drop (ft.water) Cooling Capacity (BTUH) Total Sensible 307 HEATING AND COOLING EQUIPMENT Power Input (Watts) 0 00.5 900 0 90 0 00.8 00 700 5 0 8 00.0 800 700 5 08 800.0 9300 5000 70 08 800.0 300 800 85 08 8 800.0 500 700 5 0,000 5.0 9300 900 30 0,000 9.0 300 000 55 0 8,000 3.0 3500 00 75,00 5.8 33500 500 355,00. 0000 800 370 8,00 7.0 700 900 00,00 3.5 00 300 35,00 7. 5900 3700 5 8,00.8 5800 3900 550 0,000.3 500 000 78 0,000 9. 8900 8000 90 0 8,000 5.0 77800 5900 50,00.8 5800 00 05,00 0.5 700 5300 30 8,00 7.3 85000 5900 95 30 3,000.0 83000 3900 830 30 3,000 9.8 500 77900 905 30 8 3,000.8 30 8800 935 NOTES:. Ratings are based on 80 F (.7 C) DB and 7 F (9. C) WB EAT, 5 F (7. C) EWT, 0 F (5. C) water temperature rise, high fan speed, motor voltage 5//0, and air flow under dry coil conditions.. For all application ratings, use IEC s computer selection program, the quick-selection ratings provided in this catalog, or contact your local IEC representative. 3. For additional information, please consult AHRI s website at www.ahrinet.org. 8 8

Cooling Capacity Unit Size CFM Rows 0 (/ HP) 08 ( HP) 0 (/ HP) 500 00 700 700 800 900 900 000 00 EAT ( F) DB/WB EWT ( F) 75 / 3 5 75 / 3 5 8 75 / 3 5 75 / 3 5 75 / 3 5 8 75 / 3 5 75 / 3 5 75 / 3 5 8 75 / 3 5 75 / 3 5 75 / 3 5 8 75 / 3 5 75 / 3 5 75 / 3 5 8 75 / 3 5 75 / 3 5 75 / 3 5 8 75 / 3 5 75 / 3 5 75 / 3 5 8 75 / 3 5 75 / 3 5 75 / 3 5 8 75 / 3 5 75 / 3 5 75 / 3 5 8 75 / 3 5 ΔT Total Sensible WPD GPM ( F) (MBH) (MBH) (ft. wg.) 0 9. 8..8 0. 8.5 8.0. 0. 0 0. 8.8.. 9. 8.3. 0.7 0 0.5 8...5 9.5 8.0..0 0.0 9.9. 0.8 9.8 9.. 0.5 0.8 0..5.5.5 0.0.9.0 0.9 0.3... 9.8.9.3 0.8.5.5.0.3 0.9.9 0. 0.9. 3.9 3.5.8.. 0 5.3. 3.7 3.9..3.7 0.8.5.5.0.3 0.9.9 0. 0.9. 3.9 3.5.8.. 0 5.3. 3.7 3.9..3.7 0.5 3.0.9..9.. 0.8 0 7.. 3.. 5.5 3.5..5 0 7.. 3.5 3.. 3..7. 0.. 3...5 3.9. 0.9 0 9. 5.9 3.8.9 7.5 5..9.9 0 0.0 5.9. 8.3 5. 3.7 0 0.3 7.3. 8.7. 3..7 0.9 8..5.7.3 7.7 3.5 3. 0 3. 8...5.5 7. 3..3 0. 9.0. 3.0 0.5 8.3 3..0 0 5. 0.3 5 5.5 3. 9. 3.9 3.7 0 5.8 0. 5. 7.7. 9.5 5. 0.0 0.7.8 3..3 0.0 3.7.3 0 7..3 5.5. 5.8..3.3 0 8.5.3 5.7 9.0.7... 9 9

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils Cooling Capacity, Cont d. Unit Size CFM Rows ( HP) (HP) 0 ( HP) 00 00 300 0 00 0 0 000 00 EAT ( F) DB/WB EWT ( F) 75/3 5 75/3 5 8 75/3 5 75/3 5 75/3 5 8 75/3 5 75/3 5 75/3 5 8 75/3 5 75/3 5 75/3 5 8 75/3 5 75/3 5 75/3 5 8 75/3 5 75/3 5 75/3 5 8 75/3 5 75/3 5 75/3 5 8 75/3 5 75/3 5 75/3 5 8 75/3 5 75/3 5 75/3 5 8 75/3 5 ΔT Total Sensible WPD GPM ( F) (MBH) (MBH) (ft. wg.) 0.0 0.7.8 3..3 0.0 3.7.3 0 7..3 5.5. 5.8..3.3 0 8.5.3 5.7 9.0.7... 0 5.8. 5. 3.8.0.7.5 0 9.9.3 5.9 7. 8.0 3.5..9 0 3..5. 0.3 9.3 3.7.8 7.0 0 7.5.0 5.5. 5.7 3.3.3.8 0 3... 8.0 30. 5. 5 5.5 0 33.9..7.7 3.7 5.7 5. 7.9 0 8..7 5..9 5.7 3..3. 0 3.3 7.7.8 3.8 3.7. 5..5 0 3.9 8. 7.3 5.8 3. 7. 5. 3.8 0 3.0 7.9.3.3 9..8.8.5 0 38.9 3.5 7.7.7 3.0 30.3 3. 0. 3.9 8. 7. 39.3 3.7.5.8 0 35.3 3. 7. 3. 9.9 5..7 0 3.3 35.3 8. 5.5 0. 3..7 3.7 0 7. 37. 9. 8.5.3 35.8 7.3 5.7 0 37. 3. 7.5.3 3. 3.0 5.7.5 0. 3.8 9..9.9 35. 7. 3.3 0 5.0 38.8 0. 7. 7. 37. 7.8 5. 0. 35. 8..7 37. 3...7 0 50.9 0.7 0. 5.7 7.3 39. 7.8 3.8 0 5. 3.. 9.0 5.7.5 8.7.0 0.3 38.7 8.8 3.0 0.8 37..7.0 0 55.3.5.5 5.7.9 8.5. 0.9 7.5.3 0. 57.8 5.7 9. 7.0 0 0

Cooling Capacity, Cont d. Unit Size CFM Rows (-/ HP) 30 (3 HP) 000 00 00 800 3000 300 EAT ( F) DB/WB EWT ( F) 75/3 5 75/3 5 8 75/3 5 75/3 5 75/3 5 8 75/3 5 75/3 5 75/3 5 8 75/3 5 75/3 5 75/3 5 8 75/3 5 75/3 5 75/3 5 8 75/3 5 75/3 5 75/3 5 8 75/3 5 ΔT Total Sensible WPD GPM ( F) (MBH) (MBH) (ft. wg.) 0. 35. 8..7 37. 3...7 0 50.9 0.7 0. 5.7 7.3 39. 7.8 3.8 0 5. 3.. 9.0 5.7.5 8.7.0 0.3 38.7 8.8 3.0 0.8 37..7.0 0 55.3.5.5 5.7.9 8.5. 0.9 7.5.3 0. 57.8 5.7 9. 7.0 0 7.5.7 9. 3. 3.9 0.3 7.3. 0 59.8 8.3.9 7.3 55.9.7 9..9 0 7.3 5.8 3.3.8 3. 50.0 0. 8.0 0 0.3 5.7. 55. 50.7 9.. 0 78.5. 5. 5.5 73.3 0.0. 3.7 0 90.5 7.7 7.9 9. 8.7 5.. 0 3.8 5.0.7. 58.8 53.9 9.7.7 0 83..5.. 78.3.3.9. 0 97. 7.8 9.3 0.3 90.9 70. 5 7.0 0 7. 59. 3.3.8.0 57.0 0..9 0 88. 70.7 7..7 83. 8. 3.7.5 0 03. 77. 0.5. 97. 7.9. 7.7

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils Heating Capacity Unit Size CFM Rows 0 (/ HP) 08 ( HP) 500 00 700 700 800 900 EWT ( F) ΔT LAT WPD MBH GPM ( F) ( F) (ft. wg.) 0 8.8 8.3 0. 0.5 0.8 93.8.3.5 0 9.0 05..5 0...3 5. 0. 97. 0.7 0. 0 0.8 08...8 0 3. 7... 0 35.8 3. 3.7 3.9 0 9.9 85.3 0.5 0. 0. 9..5.9 0.3 0.9..8 0 5. 08.8..7 0.7 95.7 0.8 0. 0 3.7 0... 0 35.3.5.8.3 0 0.9 33...8 0 0.9 8. 0.5 0.7 0 5.8 90.9. 3. 0 3. 00.9. 0 7.7 0..8 7.8 0 8.5 9.5 0.9 0.5 0.3 0.8.7. 0 39..9.5 0 5.5 30.. 5.7 0 0.0 83.3 0.5 0. 0.7 89..5 3 0.7 98.7..8 0 5. 03.9..9 0 7.3 9.9 0.9 0.5 0.8 0.8.5.3 0 3.8 8.7.9. 0.9.7. 5. 0. 8.9 0. 0.7 0. 88.7. 3.5 0 3.9 97.7.. 0 8.3 0.8.9 8. 0 9.3 9.3 0.5 0 7.5 0.8.8.7 0 0.9 7.3..7 0 7.7 5..9. 0. 8.5 0. 0.8 0 7. 88..8 0. 9.8.3. 0 30.9 0.8 3. 9.3 0. 9.7. 0. 0 30. 0 3 3. 0.8..3.9 0 5.3 3.8 5.3 7. NOTES:. Based on 70 F (. C) entering air temperature.. For leaving air temperature above 30 F (5. C) consult the factory.

Heating Capacity, Cont d. Unit Size CFM Rows 0 (/ HP) ( HP) 900 000 00 00 00 300 EWT ( F) ΔT LAT WPD MBH GPM ( F) ( F) (ft. wg.) 0. 8.5 0.8.5 0.0 9.. 7. 0 3. 03..7.3 0 37.8 08.9 3.9 5.9 0 7.3 98... 0 3. 07. 3. 5.3 0 5. 5.7.8 3. 0. 33..3.5 0 7. 85.9 0.9.7 0 3. 9.7. 7.9 0 3.8 0..8.8 0 0. 07.. 7.7 0 9.3 97..5.3 0 38.9 0 3.9 5.9 0 58. 3.9 3 3. 0.3 3..8 3 0 8. 85. 0.9.8 0.8 90.9.5 8.7 0 3.8 0.9 5. 0.8 0. 9. 0 3. 9... 0.5 05..5 0.. 3. 0 70.9 9.7 7.. 0 8. 85. 0.9.8 0.8 90.9.5 8.7 0 3.8 0.9 5. 0.8 0. 9. 0 3. 9... 0.5 05..5 0.. 3. 0 70.9 9.7 7.. 0 9.0 8.7 0. 90.. 9. 0 38.8 99.9 5.7 0 5. 0.8. 0 33.0 95..7. 0.0 0. 7. 0 5.8 0.7 3.3. 0 75. 8 7.7 5.8 0 9.9 8.. 0 7. 89.5.8 0. 0 0.7 99.. 0 0.0 0 3.7 9.7.7.7 0. 03..7 7.8 0 9.3 9. 3.5.7 0 79.. 8. 7. NOTES:. Based on 70 F (. C) entering air temperature.. For leaving air temperature above 30 F (5. C) consult the factory. 3 3

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils Heating Capacity, Cont d. Unit Size CFM Rows ( HP) 0 ( HP) 0 00 0 0 000 00 EWT ( F) ΔT LAT WPD MBH GPM ( F) ( F) (ft. wg.) 0. 8. 0.5 0 3. 90.7 3..5 0. 00.5.3.5 0 5.7 0. 5. 5.7 0 39.5 9. 0.9 0 53. 05.3 5.. 0 79.7.7..5 0 9. 30. 9.3 9. 0 3.0 83.3. 0.5 0 33.8 89. 3..8 0 50.0 98.9.5.7 0 59.3 0.3.5 0 3. 95. 0 58. 03.8 5.9.8 0 87. 0.5..9 0 00. 8 0. 0. 0.7 8.7. 0. 0 3.3 88.7 3.7 3. 0 53. 97.5.7.9 0 3.7 0.7.5 7.3 0.5 93.9.3. 0 3. 0.5. 5. 0 9. 8..8 3.3 0 08.5 5.8. 0 8. 8.. 0.9 0 39.7 90.. 0 58.8 00. 3. 0 9.0 05.5 7 9.9 0 5.9 93..3 0.5 0 5. 03...7 0 97. 0.9.7 0 3.3 8.3.5. 0 9.9 83.8.5 0.3 89..3.8 0.5 99 3..9 0 73.5 0 7.5 0.9 0 9.3 9.8.5 0. 0 70. 0.5 7. 3 0 0. 8. 5.3.8 0.7.3..9 0 3. 83.3. 0.7 88.8.5 5. 0. 97.8 3. 3. 0 77.8 0.7 7.9.9 0 5. 9.. 0.7 0 7. 0. 7.5 3. 0 0.8.7 5. 0 9.7. 3. 7. NOTES:. Based on 70 F (. C) entering air temperature.. For leaving air temperature above 30 F (5. C) consult the factory.

Heating Capacity, Cont d. Unit Size CFM Rows ( / HP) 30 (3 HP) 000 00 00 800 3000 300 EWT ( F) ΔT LAT WPD MBH GPM ( F) ( F) (ft. wg.) 0 9.9 83.8.5 0.3 89..3.8 0.5 99 3..9 0 73.5 0 7.5 0.9 0 9.3 9.8.5 0. 0 70. 0.5 7. 3 0 0. 8. 5.3.8 0.7.3..9 0 3. 83.3. 0.7 88.8.5 5. 0. 97.8 3. 3. 0 77.8 0.7 7.9.9 0 5. 9.. 0.7 0 7. 0. 7.5 3. 0 0.8.7 5. 0 9.7. 3. 7. 0 33. 8.8.7. 0 7.0 88..7 5.7 0 9.5 9.8 3.5 3. 0 8.9 0. 8.3.9 0 55. 9..8 0.7 0 78.9 00. 8 3.7 0 7. 5.. 0 37.3 3 8.3 0 3.8 80.5. 0. 0 58.0 89. 5.8 0 85. 98..3 0. 0 0. 0. 0..5 0 7. 93. 3. 0.5 0 0.3 03.8 0.3.3 0 5.3 0. 7.7. 0 77. 8. 8. 5. 0 33. 80..7 0. 0 0. 88.7.. 0 88.7 97..5 0.7 0 08.5 03.5.. 0 7.9 93. 3.8 0.5 0 07. 03. 0.8.5 0 59. 9. 8..5 0 85.7 7.3 8.9 5. 0 35. 80..8 0. 0.8 88..3. 0 9. 9.7.7 0.7 0.7 0..5.8 0 78. 9. 3.9 0.5 0.8 0..3. 0.3 8. 8.. 0 9.0. 9.8 5.9 5 5

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils Component Static Resistance Table (in w.c.) Unit Size 0 08 0 0 30 Nominal CFM Dry Coil (includes cabinet) Row 5 Row Row 7 Row 8 Row " MERV 8 Pleated (Qty. ) " Throwaway " MERV 8 Pleated Filters " MERV w/prefilter MERV Pleated MERV 3 Pleated Mixing Box 00 0.07 0.08 0.0 0. 0. 0.07 0.05 0.0 0.0 0.03 0.0 0.0 500 0. 0.3 0. 0.8 0.9 0. 0.07 0.05 0.0 0.05 0.0 0.03 00 0.5 0.9 0. 0. 0.7 0. 0.09 0.0 0.07 0.0 0.08 0.0 700 0.0 0. 0.8 0.3 0.3 0.7 0. 0.08 0.09 0.08 0.0 0.0 800 0. 0.9 0.3 0.38 0. 0. 0. 0.09 0. 0.09 0. 0.08 00 0.5 0.9 0. 0. 0.7 0. 0.09 0.0 0.07 0.0 0.08 0.0 700 0.0 0. 0.8 0.3 0.3 0.7 0. 0.08 0.09 0.08 0.0 0.0 800 0. 0.9 0.3 0.38 0. 0. 0. 0.09 0. 0.09 0. 0.08 900 0.8 0.3 0.0 0.5 0.9 0. 0. 0.0 0. 0.0 0. 0.0 000 0.33 0.0 0. 0.5 0.57 0.7 0.8 0. 0. 0. 0. 0. 800 0. 0. 0. 0.8 0. 0.0 0.08 0.0 0.3 0.05 0.05 0.0 900 0.5 0.8 0. 0. 0. 0. 0.09 0.07 0. 0.0 0.0 0.05 000 0.9 0. 0. 0.9 0.3 0. 0. 0.08 0.8 0.07 0.07 0.0 00 0. 0. 0.30 0.3 0.37 0. 0.3 0.09 0. 0.08 0.08 0.08 00 0.5 0.30 0.35 0.39 0.3 0.8 0. 0.0 0.3 0.09 0.09 0.09 000 0.9 0. 0. 0.9 0.3 0. 0. 0.08 0.8 0.07 0.07 0.0 00 0. 0. 0.30 0.3 0.37 0. 0.3 0.09 0. 0.08 0.08 0.08 00 0.5 0.30 0.35 0.39 0.3 0.8 0. 0.0 0.3 0.09 0.09 0.09 300 0.9 0.3 0.0 0. 0.8 0.9 0. 0. 0.5 0.0 0.0 0. 0 0.3 0.38 0. 0.9 0.5 0. 0.8 0. 0.8 0. 0. 0.3 0 0.9 0.3 0.8 0.3 0.3 0. 0.7 0.0 0. 0.09 0.09 0.07 500 0. 0. 0.3 0.35 0.38 0. 0.9 0.0 0. 0.0 0.0 0.09 00 0. 0.9 0.35 0.38 0. 0.7 0. 0. 0. 0. 0. 0.0 700 0.7 0.3 0.38 0. 0.7 0.9 0. 0. 0.8 0. 0. 0. 0 0.9 0.35 0. 0. 0.5 0.0 0. 0.3 0.30 0. 0.3 0. 0 0. 0.7 0.3 0.37 0. 0.8 0.7 0. 0. 0.0 0.3 0.07 900 0. 0.30 0.3 0. 0. 0.9 0.8 0. 0. 0. 0. 0.08 000 0.7 0.33 0.39 0.5 0.50 0. 0.0 0.3 0.8 0. 0.5 0.09 00 0.9 0.3 0. 0.9 0.55 0. 0. 0.3 0.30 0.3 0. 0.0 00 0.3 0.39 0. 0.53 0.59 0. 0.3 0. 0.3 0. 0.7 0. 300 0.3 0. 0.9 0.57 0. 0.5 0.5 0.5 0.3 0.5 0.8 0. 00 0.3 0. 0.53 0.0 0.8 0.7 0. 0. 0.3 0. 0.0 0.3 0 0. 0.7 0.3 0.37 0. 0.8 0.7 0. 0. 0.0 0.3 0.07 900 0. 0.30 0.3 0. 0. 0.9 0.8 0. 0. 0. 0. 0.08 000 0.7 0.33 0.39 0.5 0.50 0. 0.0 0.3 0.8 0. 0.5 0.09 00 0.9 0.3 0. 0.9 0.55 0. 0. 0.3 0.30 0.3 0. 0.0 00 0.3 0.39 0. 0.53 0.59 0. 0.3 0. 0.3 0. 0.7 0. 300 0.3 0. 0.9 0.57 0. 0.5 0.5 0.5 0.3 0.5 0.8 0. 00 0.3 0. 0.53 0.0 0.8 0.7 0. 0. 0.3 0. 0.0 0.3 00 0.7 0. 0. 0.8 0.33 0.5 0. 0.0 0.9 0.07 0. 0.07 00 0.0 0. 0.8 0.33 0.38 0. 0. 0. 0. 0.08 0.3 0.09 800 0.3 0.7 0.3 0.38 0.3 0.8 0.7 0. 0. 0.09 0. 0.0 3000 0. 0.3 0.3 0. 0.9 0.0 0.9 0. 0. 0.0 0. 0. 300 0.9 0.3 0.0 0.7 0.5 0. 0. 0.5 0.8 0. 0.8 0.3 300 0.3 0.38 0. 0.5 0.59 0. 0.3 0. 0.3 0.3 0.9 0.5

Sound Power Data UNIT SIZE RATING FAN SPEED CFM SOUND POWER LEVEL, Lw (db reference one picowatt) 5 Hz 50 Hz 500 Hz K Hz K Hz K Hz 8K Hz A-wgt (dba) Motor HP CASING RADIATED NOTE DUCTED DISCHARGE NOTE 3 90 00 @.50 ESP 8 59 5 50 38 58 58 5 5 5 5 39 55 / 8 CASING RADIATED NOTE DUCTED DISCHARGE NOTE 3,05 800 @.50 ESP 9 5 7 0 7 59 3 58 5 0 NOTE CASING RADIATED NOTE DUCTED DISCHARGE NOTE 3,095,000 @.50 ESP 70 3 55 9 7 3 5 0 55 9 3 / NOTE CASING RADIATED NOTE DUCTED DISCHARGE NOTE 3,0,00@.50 ESP 70 73 59 5 5 5 9 70 5 8 0 5 7 NOTE 5 CASING RADIATED NOTE DUCTED DISCHARGE NOTE 3,0,00@.50 ESP 75 8 5 7 5 5 7 9 7 7 7 3 57 9 0 NOTE 5 CASING RADIATED NOTE DUCTED DISCHARGE NOTE 3,00,000@.50 ESP 7 7 7 5 58 5 5 7 7 9 70 3 53 8 NOTE 5 CASING RADIATED NOTE DUCTED DISCHARGE NOTE 3,085,00@.50 ESP 79 73 7 9 57 8 9 75 7 7 7 8 73 -/ 30 NOTE 5 CASING RADIATED NOTE DUCTED DISCHARGE NOTE 3 95 3,000@.50 ESP 77 7 7 7 57 8 7 7 7 77 7 8 7 59 7 Notes:. Unit Test Configuration: Front Return/Top Supply, Row, 0 FPI Coil, 5/ PH/ 0HZ VAC Motor, Fiberglass Filter, dual density fiberglass insulation.. Testing per AHRI 0-00:...3 Casing radiated with free inlet, Sound Rating of Ducted Air Moving and Conditioning Equipment. 3. Testing per AHRI 0-00:... Ducted discharge, Sound Rating of Ducted Air Moving and Conditioning Equipment.. Unit Test Configuration: Front Return/Top Supply, Row, 0 FPI Coil, 30/ PH/ 0HZ VAC Motor, Fiberglass Filter, dual density fiberglass insulation. 5. Unit Test Configuration: Front Return/Top Supply, Row, 0 FPI Coil, 30/3 PH/ 0HZ VAC Motor, Fiberglass Filter, dual density fiberglass insulation.. Sound power data is expressed in decibels, db RE: x 0- w (picowatts). 3 7 7

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils VDY Fan Curves Operating units outside the recommended operating range can cause the electric heater nuisance tripping, condensate carryover and/or fan instability. Recommended operating range control voltage settings shown for reference only. Consult factory for specific voltage settings per application..5 VDY0, / HP Motor.75 TOTAL STATIC PRESSURE.5.5 0.75 0.5 RECOMMENDED OPERATING RANGE (0.0 VDC) (5. VDC) 0.5 0 (.7 VDC) 0 00 00 00 800 000 00 SCFM RPM 00 00 800 000 00 0 VDY08, HP Motor.75.5.5 (9.7 VDC) (0.0 VDC) TOTAL STATIC PRESSURE.75.5.5 0.75 (5. VDC) RECOMMENDED OPERATING RANGE 0.5 (5. VDC) 0.5 (3.5 VDC) 0 0 00 00 00 800 000 00 0 00 SCFM RPM 00 00 800 000 00 0 00 0 8 8

VDY Fan Curves, Cont d. VDY0, / HP Motor.5.5 TOTAL STATIC PRESSURE.75.5.5 0.75 (. VDC) (0.0 VDC) RECOMMENDED OPERATING RANGE (8.5 VDC) 0.5 0.5 (. VDC) (3.7 VDC) 0 00 00 00 800 000 00 0 00 0 000 SCFM.5 RPM 00 800 000 00 0 00 0 VDY, HP Motor.5 (0.0 VDC) (0.0 VDC).75 TOTAL STATIC PRESSURE.5.5 (. VDC) RECOMMENDED OPERATING RANGE (8. VDC) 0.75 0.5 (.0 VDC) 0.5 (3.5 VDC) 0 00 00 00 800 000 00 0 00 0 000 SCFM RPM 00 800 000 00 0 00 0 9 9

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils VDY Fan Curves, Cont d. 3 VDY, HP Motor.75.5 (0.0 VDC).5 TOTAL STATIC PRESSURE.75.5.5 0.75 (5.3 VDC) RECOMMENDED OPERATING RANGE (9.0 VDC) 0.5 (.5 VDC) 0.5 (3.7 VDC) 0 00 00 800 000 00 0 00 0 000 00 00 SCFM RPM 00 800 000 00 0 00 3 VDY0, HP Motor.75.5.5 TOTAL STATIC PRESSURE.75.5.5 0.75 (0.0 VDC) RECOMMENDED OPERATING RANGE (8.5 VDC) 0.5 0.5 (.8 VDC) (. VDC) 0 00 800 00 00 000 00 800 SCFM RPM 00 800 000 00 0 0 0

VDY Fan Curves, Cont d. VDY,.5 HP Motor 3.75.5 (0.0 VDC).5 (0.0 VDC) TOTAL STATIC PRESSURE.75.5.5 (8.8 VDC) RECOMMENDED OPERATING RANGE 0.75 0.5 0.5 (. VDC) (5. VDC) 0 00 800 00 00 000 00 800 SCFM RPM 00 800 000 00 0 VDY30, 3 HP Motor 3.5 3.5 3.75.5 TOTAL STATIC PRESSURE.5.75.5 (0.0 VDC) (9.0 VDC).5 0.75 (5.9 VDC) RECOMMENDED OPERATING RANGE 0.5 (5. VDC) 0.5 (3.7 VDC) 0 0 500 000 500 000 500 3000 3500 000 500 SCFM RPM 00 800 000 00 0

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils VDY Unit Vertical Direct Drive Drawing is not to scale and is provided for reference only. Dimensions may vary with options ordered. Consult IEC website for up-to-date drawings. Size Fan Size 0 9 x 08 9 x 0 9 x 9 x 0 x 7 0/ x 0 30 x Depth Width Height 0 (508) 0 (508) (559) (559) (559) (0) 8 (7) 8 (7) 8 (7) 37 (90) 37 (90) 7 (9) 8 (9) 8 (9) 3-/ (97) 3-/ (97) 39-3/8 (000) 39-3/8 (000) 39-3/8 (000) 5-/8 () 5-/ (378) Supply Duct Return Duct Aux.Ctrl. Box Unit side to Unit bottom duct flange to duct flange A B C E F L M N 8-7/8 0-7/8 5-/8 -/ -/ -7/8-7/8 (5) (7) (38) () (35) () (8) (73) 8-7/8 0-7/8 5-/8 -/ -/ -7/8-7/8 (5) (7) (38) () (35) ( (8) (73) 8-7/8 0-7/8 -/ 33-/ 5-3/ 0-7/8-7/8 (5) (7) (5) (85) (0) (0) (8) (73) 8-7/8 0-7/8 -/ 33-/ 5-3/ 0-7/8-7/8 (5) (7) (5) (85) (0) (0) (8) (73) 0-3/8-5/8 3-7/8 5-3/ -5/8-7/8 3(7) () (305) () (5) (0) (8) (73) 3-7/8 3 7-/8 -/ 8 -/ -7/8 3-/8 (35) (330) (35) () (57) () (8) (79) -/ -/ -/ 3-5/8-7/8-3/ (3) (35) (0) () (73) (9) (8) (70) NOTES:. RH shown, LH opposite.. All dimensions are +/- /" ( mm). 3. Product specifications are subject to changes without notice.. Dimensions in parenthesis are shown in (millimeters). 5. Allow adequate spacing for maneuverability around unit to allow service through recommended access area.. C dimension is measured from coil side of unit. 7. Mixing Box option will vary return duct dimensions, refer to mixing box submittal.

VDY Unit with Optional Mixing Box Drawing is not to scale and is provided for reference only. Dimensions may vary with options ordered. Consult IEC website for up-to-date drawings. Size Fan Size Depth Unit Depth Width Height Supply Duct Return Duct Mix Box Aux.Box Unit side to duct flange Unit bottom to duct flange A B C E F H L M N 0 9 x 35-/ 0 8 3-/ 8-7/8 0-7/8 5-/8 -/ -7/8-7/8 (90) (508) (7) (97) (5) (7) (38) (0) (5) (79) () (8) (73) 08 9 x 35-/ 0 8 3-/ 8-7/8 0-7/8 5-/8 -/ -7/8 (90) (508) (7) (97) (5) (7) (38) (0) (5) (79) () (5) (73) 0 9 x 39-/ 37 39-3/8 8-7/8 0-7/8 -/ 33 8 3 0-7/8-7/8 (003) (559) (90) (000) (5) (7) (5) (838) (03) (330) (0) (8) (73) 9 x 39-/ 37 39-3/8 8-7/8 0-7/8 -/ 33 8 3 0-7/8-7/8 (003) (559) (90) (000) (5) (7) (5) (838) (03) (330) (0) (8) (73) 0 x 7 39-/ 7 39-3/8 0-3/8-5/8 3 8 3 3-5/8-7/8 (003) (559) (9) (000) () (305) () (09) (03) (330) (7) () (73) 0/ x 0 -/ 8 5-/8 3-7/8 3 7-/8 8 3 -/ -7/8 3-/8 (05) (0) (9) () (35) (330) (35) (8) (03) (330) () (8) (79) 7-/ 8 8 5-/ -/ 0 5 3-5/8-7/8-7/8 30 x (07) (7) (9) (378) (3) (35) (0) (8) (5) (38) (9) (8) (73) NOTES:. RH shown, LH opposite.. All dimensions are +/- / ( mm). 3. Product specifications are subject to changes without notice.. Dimensions in parenthesis are shown in (millimeters). 5. Allow adequate spacing for maneuverability around unit to allow service through recommended access area.. C dimension is measured from coil side of unit. 7. Mixing Box option will vary return duct dimensions, refer to mixing box submittal. 8. Mixing Box options include: A) Knockdown base rails for field assembly; B) Pre-assembled Mixing Box. 9. Linkage kit supplied with Mixing Box is provided for field installation of actuator, consisting of crank arms, swivels, and either a 5 (sizes 0-) or 3 (sizes 0-30) length of 5/ rod. 0. Add (5) if using a Prefilter, or (0) filter. 3 3

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils Piping Connection Location (Centerline to Centerline) Hydronic Cooling and Heating Coils Vertical, right hand unit with re-heat coil shown. D C CR - Cold Water Return HR - Hot Water Return CS - Cold Water Supply HS - Hot Water Supply RH - Right Hand LH - Left Hand B DRAIN A (5) -5/8() 0 0 -/(8) RH UNIT TELL-TALE -7/8(75) G 8-5/8(9) F 0-3/8() E LH UNIT TELL-TALE Coil Header Connection Size 8 Row Row Row Row HW Row HW Unit Size Nom. OD Nom. OD Nom. OD Nom. OD Nom. OD Size Size Size Size Size 0-.5 3/ 0.875 3/ 0.875 / 0.5 / 0.5 -.5.5.5.5 / 0.5 30 -/.5 -/.5 -/.5 -/.5 -/.5 Unit Size 0/08 0/ 0/ 30 Coil Rows Cool Heat A B C D E F G 3-/ 5-/ 7 7 5-5/ 3-3/ 5-3/ 7-9/ 7-9/ -/8-3/ 3-/ 5-/ 9-3/ 9-3/ 8-/8 3-3/ 5-3/ 9-3/ 9-3/ 8 0-/ 5-/8 7-/8 7 7 5-5/ 5-7/ 7-7/ 7-9/ 7-9/ 7-3/ -3/8 5-/8 7-/8 9-3/ 9-3/ 8-/8 5-7/ 7-7/ 9-3/ 9-3/ 8 0-/ 7-3/ LH 0-5/8 5-5/8 9-5/8 7 7-3/ RH 3-3/8 9-5/8 7 5-5/ 7-3/8 3-5/8 0-3/8 7-9/ 7-3/ LH 0-5/8 5-5/8-3/ 9-3/ 7-3/ RH 3-3/8-3/ 9-3/ 8-/8 7-3/8 3-5/8 -/ 9-3/ 8 9-/ 5-5/8 0-/ 7-3/ LH -5/ 5-5/ 7-3/ 3-5/ 9-5/8 RH -/ 7-9/ 7-7/8 5-3/ 9-/ 5 7-3/ 8-3/ LH -5/ 8-/8 7-3/ 3-5/ -3/ RH -/ 9-3/ -9/ 7-7/8 5-3/ -/ 7-/8 8 7-3/ 0-/ 5-5/ 7-/ 5-3/ 9 0-5/ 3-3/ 9-/8 7-7/8 5-5/ -5/ 8-/8 7-/ 5-3/ -/8 0-5/ 3-3/ -5/ 9-/8 7-/ 8 0-/

Piping Connection Location (Centerline to Centerline) R-0A Cooling with Hot Water Heating Vertical, right hand unit with pre-heat coil shown. D Coil Header Connection Size (Nominal OD in Inches) LL SL Row HW Row HW Unit Size Nom. Nom. Nom. Nom. OD OD OD OD Size Size Size Size 0- / 0.375 3/ 0.875 / 0.5 / 0.5 - / 0.375.5.5 / 0.5 30 / 0.5 -/.5 -/.5 -/.5 C B A (5) -5/8() 0 DRAIN HR - Hot Water Return HS - Hot Water Supply LL - Liquid Line SL - Suction Line 0 RH UNIT TELL-TALE H G -7/8(75) 8-5/8(9) F E LH UNIT TELL-TALE SIZE 0/08 0/ 0/ 30 COIL ROWS DX ONLY WATER A B C D E F G PRE-HEAT H -3/ -3/ 5-/ -/ 3-3/ -5/8-5/8 8-7/8 3-/ 3-/ -3/ -/ 7-/8 -/ 3-3/ -5/8-5/8 5-/8 7-/8-7/8 3-/ 3-/ -3/ 7-/8 -/ 5-/8 7-/8 -/ 3-3/ -5/8-5/8-3/8 0 3-5/8 -/8 -/8-5/8-3/ -/ 7-/8 5-/ 9-3/ -/ 3-3/ -5/8-5/8-3/ 7-/ -5/8 5-7/8-3/ -/ -5/8-5/8 5-3/8-3/ -/8 5-7/8 -/ -/8-7/8 5-3/8 0-3/8 3-7/8-3/8 -/ -5/8 5 5

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils Electric Heater Selection Electric heaters are available on IEC Direct Drive blower coils for total electric heat. Total Electric Heat Total electric heat eliminates the requirement for a boiler and provides heating and/or cooling on an individual basis throughout the year. Electric heat is available only for single source power (motor and heater voltage the same). Heater Construction Single Phase Electric Heater Availability The heater coils are made of high-grade resistance wire and they are supported by ceramic insulators on plated steel brackets. These heat elements are suspended directly in front of the outlet after the blower and the coil. An auto and a manual thermal limit switch protect the heater in the event of air failure. For electric heat control options refer to page 9. kw Electric Heat Amps Unit Size Heater Stages Single Phase ( or stage) 8 0 0 0V 08V 0V 77V stg stg stg stg stg stg stg stg stg stg stg stg.0 8.3.8. 3. X X.5.5 7..3 5. X X X X.0.7 9. 8.3 7. X X X X.5 0.8.0 0. 9.0 X X X X X 3.0 5.0..5 0.8 X X X X X X X X X X 3.5 9..8.. X X X X X X X X X X X X.0 33.3 9..7. X X X X X X X X X X X X.5 37.5. 8.8. X X X X X X X X X X X X 5.0.0 0.8 8. X X X X X X X X X X X X.0 8.8 5.0.7 X X X X X X X X X X X X 7.0 33.7 9. 5.3 X X X X X X X X X X 8.0 38.5 33.3 8.9 X X X X X X X X X X 9.9 35.7 X X X X X X X X.0 3.3 X X X X X X X Available option Not available option NOTES:. Electric Heating Capacities BTUh)=Heater kw x 33. Electric Heater Amperage for Single-phase Power = (Heater kw x 000)/Applied Voltage

Three Phase Electric Heater Availability kw Electric Heat Amps Three Phase (, or 3 stage) Unit Size Heater Stages 8 0 0/ 30 08V 0V 80V stg stg stg stg stg stg stg stg 3stg stg stg 3stg stg stg 3stg stg stg 3stg.0.8.. X X.5. 3..8 X X X X.0 5..8. X X X X.5.9.0 3.0 X X X X X 3.0 8.3 7. 3. X X X X X 3.5 9.7 8.. X X X X X X.0. 9..8 X X X X X X X X X X X X.5.5 0.8 5. X X X X X X X X X X X X 5.0 3.9.0.0 X X X X X X X X X X X X.0.7. 7. X X X X X X X X X X X X X X 7.0 9..8 8. X X X X X X X X X X X X 8.0. 9. 9. X X X X X X X X X X X X 9.9 7.5 3.8.9 X X X X X X X X X X.0 33.3 8.9. X X X X X X X X X X X X.0 38.9 33.7.8 X X X X X X X X X 5.0. 3. 8.0 X X X X X X X X X.0 38.5 9. X X X X X X X X X 8.0.7 X X X X X X 9.9 3.9 X X X X X X 5.0 30. X X X 30.0 3. X X X X Available option Not available option NOTES:. Electric Heating Capacities BTUh)=Heater kw x 33. Electric Heater Amp. for 3-phase Power = (Heater kw x 000)/(Applied Voltage x.73). 7 7

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils Motor Data Thermal Overload Protection All standard motors on Vertical Direct Drive units furnished by IEC contain internal thermal overload protection. The overload automatically resets when the temperature returns to a safe limit. These thermal overloads replace the need for motor starters. Motor Performance Data (Full Load AMPS) MOTOR TYPE VOLTAGE UNIT SIZE 0, 0 08,,, 0 30 MOTOR HORSEPOWER AND FLA / HP HP -/ HP 3 HP -PHASE SINGLE SPEED STANDARD EFFICIENCY 3-PHASE SINGLE SPEED STANDARD EFFICIENCY 5V/ PHASE/50-0 HZ. 0.7 N/A N/A 08V/ PHASE/50-0 HZ 3.8.3 N/A N/A 30V/ PHASE/50-0 HZ 3. 5.8 N/A N/A 77V/ PHASE/50-0 HZ 3. 5. N/A N/A 08V/3 PHASE/50-0 HZ.0 3.7. 8.9 30V/3 PHASE/50-0 HZ.85 3.3. 8.9 0V/3 PHASE/50-0 HZ.0.75.. 8 8

Factory Installed Options Controls: Motor Controls: Two controls schemes are available: 3 - Speed adjustable. Proportional (0-0 VDC) Electric Heat Controls Electric heaters come standard with a transformer, heater contactors, electric heat fusing, a terminal strip and -volt control fusing. Condensate Float Switch A water-level sensing device designed to prevent drain pan overflow. The standard switch is wired normally closed. Switches are available only in V. An optional interlocking disconnect switch is available. Control Box Electric Heater Limit Switch Knob Auxillary Control Box (supplied when ordered with Heater Fuses 3-speed controls) Disconnect Switch Bonded Ground V Control Fuse Wrapper Serial Plate Wiring Diagram Contactors Terminal Strip (inside the door) Transformer Above is the example of Control box for Size 0 unit with electric heat and disconnect switch. Equipment Ground Terminal Motor Control Board 9 9

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils Unit Total Weight The following operating weight information is based on 8-row water-filled coils and double wall cabinet construction. For a different coil and cabinet options, use the weight correction factor table. Vertical Units (Top View) B A A B LH COIL RH COIL D C C D NOTE: Some unit components are removed for clarity. Vertical Unit Corner Weight VDY Unit No Electric Heat (lb.) With Electric Heat (lb.) A B C D Total A B C D Total 0 7 38 35 9 85 0 9 8 08 85 39 37 38 99 9 8 7 3 0 78 5 78 5 8 58 55 8 83 8 5 80 55 97 58 9 309 85 7 8 30 05 79 70 9 3 0 90 8 77 88 339 88 8 99 379 0 90 73 90 33 33 88 9 99 30 7 3 8 58 0 3 37 58 Total Unit Weight Adjustment (lb.) VDY These weights are for 8-row water-filled coils and double wall construction. For a different number of rows, total unit weight can be determined by steps below: a. Identify the size of unit and number of rows b. From the previous table, identify the total weight of the unit c. From the table below, identify the correction factor and deduct this factor from the total weight. Options 8 0 0 30 -Row Coil - - -8-8 -39 - - -98 5-Row Coil - - - - -9-35 -35-7 -Row Coil - - - - -0-3 -3-9 7-Row Coil -5-5 -7-7 -0 - - -5 Single Wall Construction -3-3 -0-0 -7-58 -58-7 NOTE:. Unit weights (shown in pounds), +/- 0 percent, are based on the largest water-filled coil. 30 30

Filters The Direct Drive cabinet model unit has a set of pleated MERV 8 filters furnished as standard equipment. Unit Size Filter Quantity Nominal Filter Sizes Inches (Millimeters) VDY 0 -/" x " (9 x 0) 08 -/" x " (9 x 0) 0 8-/" x 33" ( x 838) 8-/" x 33" ( x 838) 8-/" x -/" ( x 5) 0/ 0-/ x " (5 x 559) 30 9" x " (737 x 559) Universal Filter Rack Design - Features and Benefits Side and top filter removal No tools needed for easy filter change, usage of super strong magnets in place of hardware Choice of, or filters Easy to modify in the field for either, or filters Robust design eliminates unit s sagging " FILTER " FILTER C SEE DETAIL X MAGNETS SEE DETAIL Y DETAIL X FILTER SUPPORT ANGLE BRACKET D " FILTER A B FILTER SUPPORT ANGLE BRACKET " FILTER BRACKET MOUNTING HOLES " FILTER BRACKET MOUNTING HOLES DETAIL Y 3 3

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils Mixing Boxes Mixing boxes can be used when outside air is required. Mixing boxes come with base rails. Refer to the drawings on pages 3 and 33 for additional information. Mixing Box with Base Rails Mixing box option includes : ) knockdown base rails for field assembly, and ) pre-assembled mixing box. Base rails are letter coded for ease of assembly and all hardware required for assembly is included. Linkage kit consists of crank arms, swivels, and either a 5 (sizes 0-) or a 3 (sizes 0-30) length of 5/ rod provided for field installation of actuator. Consult factory for the V damper actuator option. Mixing box option adds 3 to the unit height due to the base rails. TOP/FRONT INLET MIXING BOX Base Rail Details (5) A W FRONT VIEW (5) D SIDE VIEW 3(7) Vertical Units Dimensions - Inches (Millimeters) Unit Type and Size W D A VDY0 8 (7) 35.5 (90). (09) VDY08 8 (7) 35.5 (90). (09) VDY0 37 (90) 39.5 (003) 8. (0) VDY 37 (90) 39.5 (003) 8. (0) VDY 7 (9) 39.5 (003) 8. (0) VDY0/ 8 (9).5(05) 8. (0) VDY30 8 (9) 7.5(07) 0. (5) 3 3

Mixing Boxes Mixing Box Details TOP VIEW TOP/FRONT INLET - VDY A (0).().() B W A H 3(7) (5) C (5) Dimensions - Inches (Millimeters) Unit Size H W A B C 0 8.5 (70) 8 (7) (5) (0) (79) 08 8.5 (70) 8 (7) (5) (0) (79) 0 0.5 (5) 37 (90) 8 (03) 33 (838) 3 (330) 0.5 (5) 37 (90) 8 (03) 33 (838) 3 (330) 0.5 (5) 7 (9) 8 (03) 3 (09) 3 (330) 0/.75 (578) 8 (9) 8 (03) (8) 3 (330) 30 3 (787) 8 (9) 0 (5) (8) 5 (38) Note: Add (5) to total unit length if using prefilter or filter with mixing box option. 33 33

Horizontal Vertical Direct Drive Direct Blower Drive CoilsBlower Coils Serial Plate example INTERNATIONAL ENVIRONMENTAL CORP For Replacement Parts Call -8-3-778 Model No: VDY00033 Unit Serial No: 70-0- ELECTRICAL ENV/PERF Motor(s): QTY of Motor(s): Motor VPH: Motor FLA: Motor HP: HP Min Circ Amps: 5.9A Heater AMPS:.A Heater Kw: 3.0 kw Heater VPH: E00-75370 08//0 7.0A Motor Current:.30A 08//0 Max ESP: - Max Inlet Water Temp: Max Outlet Air Temp: - Max Hot Water or Steam: High Side Coil Design: Low Side Coil Design: Coil Test: 300 PSIG Refrigerant Type: ARI Model: - - - - 90F PSIG Max Water Coil Leaving Air or Max Motor AMB: Max Fuse or Max Circ Breaker (HACR Type NEC): - 5A - SCCR: 5KA Replacement Parts: Manufactured in the USA Unit Intended for Indoor Use Only & Suited For 0.00 Clearance From Combustible Surfaces 3 3

35 35

Contact your local IEC Sales Representative for further details and pricing applicable to this product. Visit our website (iec-okc.com) to find your local IEC Sales Rep. IEC Catalog Part #: I00-900350 CA-09(/09) 09 International Environmental Corporation (IEC) PO Box 598 Oklahoma City, OK 730-598 P: 05.05.5000 F: 05.05.500 www.iec-okc.com