Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate.

Similar documents
88MLV Series Open Channel Modular UV Systems

UV disinfection. System. Type A Series. Main applications: Potable water, process water, hot water/legionellae DIN EN ISO 9001 DIN EN ISO 14001

PRINCIPLE MAIN APPLICATION

UV I UNIT030W / UV I UNIT055W

1020 Industrial Drive, Orlinda, TN fax

SmartStream UV. Ultraviolet Water Disinfection System. Maximize Water Quality Without Chemicals. Watts.com

Quadron UV Series. Sustainable UV Disinfection with Minimum Footprint

ultraviolet.com Effective Virtually all microorganisms are susceptible to MIGHTY PURE TM ultraviolet disinfection.

SLT-Series Installation and maintenance instructions

S-Series. Protect your water from pathogens and disease with the UV-Guard S-Series. Protect:

Installation & operating manual. Swimming pool water. UV disinfection device UV10+

ULTRA-VIOLET STERILIZATION

WEDECO Quadron UV System

OptiVenn TM Series INDUSTRIAL UV SYSTEMS. High performance, cost-effective system for stringent Industrial applications

Section 3: Ultraviolet - UV

Spektron UV Series SHINING NEW LIGHT ON DRINKING WATER DISINFECTION

WATER STERILIZERS TYPE: AM1; AM2; AM3; AM4; AM5; AM6; AM8; AM10; AM12; AM15

A measured step forward

Ultraviolet Water Sterilizer Installation and Maintenance Manual

VIQUA is an ISO9001:2008 registered company specializing in the design, manufacture and sale of ultraviolet systems for:

AMERICAN AIR & WATER, INC.

Professional Amalgam Non-regulated

INSTALLATION & MAINTENANCE

ULTRAVIOLET PORTABLE AREA SANITIZER

uv and ozone for commercial pools

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

PureLine D. Technical Specification

Intense, cold and dry Efficient disinfection of packaging materials Premium UV solutions from Heraeus Noblelight

GERMICIDAL ULTRAVIOLET FIXTURES

Ultraviolet Air Disinfection Equipment

PURION UV plants for disinfection

254 Nanometer Germicidal UV Disinfection Systems

REGISTERED HANDBOOK. Document: ECN: Revision: C. MANUAL, O&M TrojanUVLogic TM System Systems Without Wiper AM, VM & TM Models

Water temperature LBX 3 LBX 33: recommended range 5-25 C (41 77 F) LBX 90e LBX 1500e: recommended range 5-45 C ( F)

NANO TECH UV-C DISINFECTION SYSTEM

S-Series Installation and maintenance instructions

HF Series R_RevB

Ultraviolet (UV) Monitoring System - Open Channel Horizontal Systems Operation and Maintenance Manual

Ultraviolet Disinfection Systems

Model 2-OZ, 3-OZ. Model 6-OZ. free standing, wall, or ceiling mount

The reference standard in UV Proven, validated treatment solutions for disinfection and taste & odor control

Customized Drinking Water

PRO Series PRO10 PRO20 PRO30

Model LIND30-EVO. Model. Model LIND24-EVO LIND24-EVO-2PM

Model RS72. Model RSCS280A. Model RSM2680

Bernd Eichler Sales Manager

ULTRAVIOLET SANITARY CONDIT IONERS

TROJANUVSWIFT SC. Drinking Water Treatment

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Ultraviolet Disinfection Systems

ULTRA-VIOLET STERILIZATION

Table of contents: Chapter V. V. Disinfection systems DOSADes

HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc.

ULTRAVIOLET INDIRECT AIR DISINFECTION

Ultraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual

Intensive UV light means not a chance for germs!

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

375 Marcus Boulevard Hauppauge, NY USA Fax: Extensive Product Information Available at:

Pro-MAX Ultraviolet Sterilizer

PRODUCT CATALOGUE 2011

SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION

Operating Manual UV Monitor UVT 18

Catalog of UV sterilizer

GERMICIDAL ULTRAVIOLET IRRADIATORS

Model D24-1S. Model D24-2S

Owner s Manual MIGHTY PURE. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Models MP16A, MP22A, MP36C & MP49C

Ultraviolet Sterilizers

PCR UV cabinets DNA/RNA

PRECAST CONCRETE. Never Looked So Good!

Large Direct-Pure EDI Water System. User Manual. RephiLe Bioscience, Ltd.

STANDARD SINGLE UV GERMICIDAL CLEANING DELUXE DUAL UV GERMICIDAL CLEANING PREMIUM DUAL UV GERMICIDAL CLEANING

AEM EASY DRUM M A N U A L

UVC in the Operating Room.

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

AS-V/186K Series. Ultraviolet Disinfection Systems. Installation, Operation and Maintenance Manual

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

Ballast 230v 50/60Hz MIN B B MIN B B MIN B B

Document No E1 Revised February Atlantic Ultraviolet Corporation

PCR UV cabinets DNA/RNA

Bio-Logic. Owner s Manual. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Ballast 120v 50/60 Hz

GRU-V Air Purifier. Product Manual

UV-medium pressure. Latest manufacturing technologies for your success product. Individual is our standard

Ultraviolet (UV) Water Treatment System

INSTALLATION INSTRUCTIONS & OWNER'S MANUAL!!!!!!!!! P/N

(UV) - R830F & ) INTRODUCTION

Ultraviolet Disinfection Unit Installation and Owners Manual

Based in the UK, Triogen is a world leading company with over twenty years experience in the design and manufacture of specialist Ozone and UV

Introducing the most technically advanced indoor air treatment system

WEDECO DLR A SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-A SERIES NO'S

Ballast MIN A

Models 120v 50/60 Hz 230v 50/60Hz MIN B A MIN B A MIN B A

BWT ECO. Fitting and operating instructions. Ultra Violet Water Disinfection System. ECO Range: LC 8 UV LC19 UV LC36 UV LC51 UV

ULTRAVIOLET (UV) DISINFECTION EQUIPMENT: MAJOR APPLICATIONS AND GLOBAL MARKETS. IAS037C January Shalini Ramamurthy Project Analyst

Customer Manual. MADE IN USA Effective

S17A, S23A, S37C & S50C

Models S2400C, S5,000C S25,000C High Capacity Systems. Read and Follow All Safety Instructions. Save These Instructions.

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

WASTEWATER DISINFECTION

ULTRAVIOLET RADIATION SYSTEMS

Transcription:

DUV Series Series description LIT has developed DUV series UV systems for industrial/commercial applications in potable water disinfection. The models of this series have packaged design with all components built in a compact stainless steel chamber and separate control cabinet. LIT DUV series units use mercury lowpressure germicidal lamps that emit UVGI at 2 nm wavelength. This wavelength is the most effective in killing bacteria, viruses and other waterborne microorganisms. Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate. Type Number of UV lamps Nominal flow rate* (m 3 /h) Power consumption (kw) Connection Control cabinet type Cleaning system type DUV - 0.62 0.02 DN 20 Type - DUV -30. 0.038 DN 2 Type - DUV - 2.2 0.06 DN 2 Type - DUV -7 3.3 0.090 DN 0 Type 2 WB-2 DUV 2-7 2 0.200 DN 0 Type 2 WB-2 DUV -7 3 0.30 DN 00 Type 2 WB-C DUV -7 0.0 DN 00 Type 2 WB-C DUV 7-7 7 78 0.600 DN 00 Type 2 WB-C 2 * 00 J/m at 98% water transmittance at the end of lamp life. Application LIT DUV series UV units are ideal for water disinfection at: municipal water supply plants of small communities, cottage villages and small towns; water supply systems of industrial enterprises; private and public swimming pools; food and beverage factories; marine industry; pharmaceutical industry; hospitals, hotels and restaurants; electronic industry. 008-0

DUV System Description and Components Advantages - reliable disinfection with low power consumption; - continual UV monitoring and control by a highly selective calibrated UV sensor; - extended lamp operating lifetime; - easy operation and maintenance; - compactness, high-quality materials and accessories; - high reliability and long service life of the reactor and components of the system; - simple and convenient lamp replacement procedure; - low costs for service and maintenance; - versatile design capabilities, UV units can be flexibly combined to achieve required capacities. Principle of operation UV reactors of DUV units has a longitudinal geometry with side inlet/outlet flanges. Water enters the reactor and is exposed to germicidal radiation that is lethal to bacteria and viruses. UV lamps are insulated from treated water by special quartz sleeves made of high quality fused quartz with high transmission coefficient for ultraviolet irradiation (9 %). After UV treatment no dangerous byproducts are formed in water. UV Dose DUV units ensure high UV dose in a wide range of water transmission values. The minimal required dose is guaranteed over all time of lamp life allowing for lamp ageing. UV Lamps All units are equipped with modern germicidal lamps having long service life: up to 2 000 hours of continuous operation. Low depreciation of UVGI intensity at the end of lamp life ensures effective disinfection during the whole operational period of DUV units. UV Sensor All DUV units are equipped with UV-radiation intensity sensor. It allows to continuously monitor UV dose and generate alarm signals when UV dose drops lower than the necessary level. The optional port for reference UV sensor can be provided. Control Cabinet PLC-based Control Cabinet provides control of each UV-lamp, monitors UV-radiation intensity, and indicates elapsed time of the lamps and number of on/off switch circles. All operating data are displayed on LCD panel. LED indicators provide information on unit faults as well as their diagnostics and alert about necessity in cleaning the disinfection chamber. Inside the Control Cabinet there are dry contacts to provide alert signals to remote control center. Standard models of DUV Control Cabinet are supplied in high-grade shockproof plastic case with certified IP6 protection class. Optional stainless steel housing can be supplied on customer s request. Cleaning System A standard delivery package of all LIT DUV units includes a special chemical cleaning system for regular flushing of disinfection chamber and quartz sleeves. Chemical cleaning system consists of s stainless steel tank, water pump and set of pipes. The tank is used for preparation of cleaning solution. The water pump provides circulation of water mixed with cleaning solution through the chamber. The 0.2 % aqueous solution of citric or oxalic acid is used for periodical cleaning (once every 2-3 month) of the disinfection chamber. Chemical cleaning method provides effective removal of fouling from quartz sleeves and inner walls of disinfection chamber and requires minimum labour and material resources. 008-02

Example of typical installation 008-03

DUV - UV System - disinfection chamber, 2 - UV lamp, 3 - quartz sleeve, - input/output valves, -drainage port, 6 - sample port, 7 - UV sensor. UV-unit type DUV - Nominal flow rate (00 J/m 2 at 98% water transmittance) 0.62 m 3 /hr Number of UV-lamps per unit UV-lamp type DB-S Guaranteed lifetime of the lamp 2 000 hours UV chamber material Stainless steel 30/36* Chamber volume,9 liters Maximum operating pressure 0 bar UV chamber protection class IP 6 Dry chamber weight. kg Power consumption 220 V / 0 Hz / 0,02 kw Connection DN 20 Water temperature C 0 C Head loss See diagram 008-0

DUV -30 UV System - disinfection chamber, 2 - UV lamp, 3 - quartz sleeve, - input/output valves, -drainage port, 6 - sample port, 7 - UV sensor. UV-unit type DUV -30 Nominal flow rate (00 J/m 2 at 98% water transmittance). m 3 /hr Number of UV-lamps per unit UV-lamp type DB-30S Guaranteed lifetime of the lamp 2 000 hours UV chamber material Stainless steel 30/36* Chamber volume 3,8 liters Maximum operating pressure 0 bar UV chamber protection class IP 6 Dry chamber weight 7. kg Power consumption 220 V / 0 Hz / 0,038 kw Connection DN 2 Water temperature C 0 C Head loss See diagram 008-0

DUV - UV System - disinfection chamber, 2 - UV lamp, 3 - quartz sleeve, - input/output valves, - drainage port, 6 - sample port, 7 - UV sensor. UV-unit type DUV - Nominal flow rate (00 J/m 2 at 98% water transmittance) 2.2 m 3 /hr Number of UV-lamps per unit UV-lamp type DB-S Guaranteed lifetime of the lamp 2 000 hours UV chamber material Stainless steel 30/36* Chamber volume 3,8 liters Maximum operating pressure 0 bar UV chamber protection class IP 6 Dry chamber weight 7. kg Power consumption 220 V / 0 Hz / 0,06 kw Connection diameter DN 2 Water temperature C 0 C Head loss See diagram 008-06

DUV -7 UV System 7 2 3 380 220 720 6 - disinfection chamber, 2 - UV lamp, 3 - quartz sleeve, - input/output flange, - cleaning port (3/ ), 6 - sample port, 7 - UV sensor. UV-unit type DUV -7 Nominal flow rate (00 J/m 2 at 98% water transmittance) 3.3 m 3 /hr Number of UV-lamps per unit UV-lamp type DB-7 Guaranteed lifetime of the lamp 2 000 hours UV chamber material Stainless steel 30/36* Chamber volume, liters Maximum operating pressure 0 bar UV chamber protection class IP 6 Dry chamber weight 6 kg Power consumption 220 V / 0-60 Hz / 0,09 kw Connection DN 0 Water temperature C 0 C Head loss See diagram 008-07

DUV 2-7 UV System 32 7 2 3 6 9 730 6 30 - disinfection chamber, 2 - UV lamp, 3 - quartz sleeve, - input/output valves, - cleaning port (3/ ), 6 - sample port, 7 - UV sensor. UV-unit type DUV 2-7 Nominal flow rate (00 J/m 2 at 98% water transmittance) m 3 /hr Number of UV-lamps per unit 2 UV-lamp type DB-7-2S Guaranteed lifetime of the lamp 2 000 hours UV chamber material Stainless steel 30/36* Chamber volume 23 liters Maximum operating pressure 0 bar UV chamber protection class IP 6 Dry chamber weight 26 kg Power consumption 220 V / 0-60 Hz / 0,2 kw Connection DN 0 Water temperature C 0 C Head loss See diagram 008-08

DUV -7 UV System 00 8 39 7 80 2 3 2 3 6 - disinfection chamber, 2 - UV lamp, 3 - quartz sleeve, - ballast cabinet, - input/output flanges, 6-cleaning port (3/ ), 7-sample port, 8 - UV sensor. UV-unit type DUV -7 Nominal flow rate (00 J/m 2 at 98% water transmittance) 3 m 3 /hr Number of UV-lamps per unit UV-lamp type DB-7 Guaranteed lifetime of the lamp 2 000 hours UV chamber material Stainless steel 30/36* Chamber volume 0 liters Maximum operating pressure 0 bar UV chamber protection class IP 6 Dry chamber weight 60 kg Power consumption 220 V / 0-60 Hz / 0,3 kw Connection DN 00 Water temperature C 0 C Head loss See diagram 008-09

DUV -7 UV System 2 3 8 7 6 3 2 30 00 6 - disinfection chamber, 2 - UV lamp, 3 - quartz sleeve, - ballast cabinet, - input/output flanges, 6 - cleaning port (3/ ), 7 - sample port, 8 - UV sensor. UV-unit type DUV -7 Nominal flow rate (00 J/m 2 at 98% water transmittance) m 3 /hr Number of UV-lamps per unit UV-lamp type DB-7 Guaranteed lifetime of the lamp 2 000 hours UV chamber material Stainless steel 30/36* Chamber volume 39 liters Maximum operating pressure 0 bar UV chamber protection class IP 6 Dry chamber weight 6 kg Power consumption 220 V / 0-60 Hz / 0, kw Connection DN 00 Water temperature C 0 C Head loss See diagram 008-0

DUV 7-7 UV System 8 6 7 3 2 7 6 0 00 - disinfection chamber, 2 - UV lamp, 3 - quartz sleeve, - ballast cabinet, - input/output flanges, 6 - cleaning port (3/ ), 7 - sample port, 8 - UV sensor, UV-unit type DUV 7-7 Nominal flow rate (00 J/m 2 at 98% water transmittance) 78 m 3 /hr Number of UV-lamps per unit 7 UV-lamp type DB-7 Guaranteed lifetime of the lamp 2 000 hours UV chamber material Stainless steel 30/36* Chamber volume 72 liters Maximum operating pressure 0 bar UV chamber protection class IP 6 Dry chamber weight 88 kg Power consumption 220 V / 0-60 Hz / 0,6 kw Connection DN 00 Water temperature C 0 C Head loss See diagram 008-

Example of typical installation of DUV plants 3 Service area for UV lamp replacement 200 min 00 00 min Service area for UV lamp replacement 200 min 700 min 2 3 - disinfection chamber, 2- ballast cabinet, 3- control cabinet, - chemical cleaning system. Installation instructions DUV units must be installed according to the instructions provided in Installation, Operating and Maintenance Manual supplied with unit. Water pressure in connecting pipes should not exceed MPa (0 Bar). It is recommended to equip water supply pipe with flow meter and flow regulating device. Sufficient space has to be allocated to install the components of UV system and provide free access to them during maintenance and repair works. Special service zones should be provided as it is indicated in assembly drawing. Control cabinet should be fixed on the wall or support frame in easily accessible place convenient for observation of the front panel. In the operating area temperature must be kept within the range of + C + 3 C, humidity - not higher than 8%RH at 20 C. 008-2

Control panel. TYPE Operating mode Power ON NORMAL WARNING FAILURE OFF LAMP REPLACEMENT General description The control panel is designed to activate the UV system and indicate operational status. The control panel is made of hard plastic with dustproof and waterproof cable glands (according to - housing, 2 - transparent cover, 3 - bracket, - cable gland, - power switch. Applicable UV units DUV - DUV -30 DUV - Electricity requirements Weight Dimensions, mm Protection class 230V / 0 Hz 2, kg 2 x 26 x 0 IP 6 Control:. Local switching on / off the UV plant. Monitoring: Local:. UV system on/off status. 2. Operational status (normal operation, warning, failure). Remote (optional):. UV system on/off status. 2. Operational status: normal operation, warning, failure. 3. UV intensity in the chamber. 008-3

OPERATIONAL TIME SIEMENS 00000 h NORMAL UV INTENSITY WARNING POWER ~220V FAILURE Control panel. TYPE 2 320 0 6 7 8 9 3 220 2 General description The control panel is designed to activate the UV system and indicate it s operational status. The control panel is made of hard plastic with dustproof and waterproof cable glands (according to protection class IP6). Behind the transparent cover of control panel are circuit breaker, operational time counter, gauge and LED s for UV system monitoring. 6 - housing, 2 - transparent door, 3 - bracket, - cable gland, - control panel front, 6 - operational time counter, 7 - LED s, 8 - circuit breaker, 9 - gauge. Applicable UV units DUV -7 DUV 2-7 DUV -7 DUV -7 DUV 7-7 Electricity requirements Weight Dimensions, mm Protection class 230V / 0Hz 0 kg 320 x 0 x 220 IP 6 Control:. Local switching on / off of the UV plant. Monitoring: Local:. UV system on/off status. 2. Operational status (normal operation, warning, failure). 3. Operational time of UV system.. UV intensity in the disinfection chamber. Remote (optional):. UV system on/off status. 2. Operational status: normal operation, warning, failure. 3. UV intensity in the chamber. 008-

Chemical cleaning system WB-2 General description The chemical cleaning system consists of a circulation pump, a stainless steel tank for preparation of cleaning solution, pipes and valves. The cleaning tank and pump are interconnected through a flexible pipe. Cleaning is done using oxalic (or citric) acid, which is supplied in the form of powder and shall be dissolved in the tank before cleaning. When the pump is powered the water starts mixing with cleaning solution and circulating through the UV chamber. After cleaning the water is drained out of the chamber through the water discharge tap mounted on the chamber. - tank for cleaning solution, 2 - pump, 3 - inlet connection, - outlet connection, - drain valve, 6 - reservior for cleaning agent, 7 - tank cap. System type WB-2 Cleaning tank material Stainless steel 30/36* Cleaning tank volume, l 0,7 Connection pipes DN 2 Cleaning agent Oxalic acid Electricity requirements 220 V, 0-60 Hz Power consumption, kw 0,72 Overall dimensions (length height width), mm Electric pump 30 20 8 Tank 20 0 2 Weight, kg: Electric pump 7 Tank 2 008-

Chemical cleaning system WB-C General description - tank for cleaning solution, 2 - pump, 3 - inlet connection, - outlet connection, - seal, 6 - tank cap. The chemical cleaning system consists of a circulation pump with the embedded stainless steel tank for preparation of cleaning solution, pipes and valves. Cleaning is done using oxalic (or citric) acid, which is supplied in the form of powder and shall be dissolved in the tank before cleaning. When the pump is powered the water starts mixing with cleaning solution and circulating through the UV chamber. After cleaning the water is drained out of the chamber through the water discharge tap mounted on the chamber. System type WB-C Cleaning tank material Plastic armored with glass fiber PRO-GF30 Cleaning tank volume, l Connection pipes DN 2 Cleaning agent Oxalic acid Electricity requirements 220 V, 0-60 Hz Power consumption, kw 0,72 Overall dimensions (length height width), mm 98 270 2 Weight, kg 9 008-6

Please contact us: LIT UV Europe Kerkhofstraat 2 HG Valkenswaard The Netherlands phone: + 3 0 22 07 30 fax: +3 8 22 68 3 e-mail: info@lit-uv-europe.net www.lit-uv-europe.net www.lit-uv-europe.com NPO «LIT» Krasnobogatirskaya,, Moscow 07076 Russia, phone: +7 (9) 733-926 fax: +7 (9) 963-073 e-mail: lit@npo.lit.ru www.lit-uv.com 008-7