EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

Similar documents
EUCCW SERIES. EUCCW4, EUCCW6 and EUCCW8 Upright 29 Conveyor Dual Rinse Dishwashing Machine. Champion, an Ali Group Company

EUCC SERIES Upright 24" Conveyor Dual Rinse Dishwashing Machine

EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

Model 80 DRHDPW 44 Single Tank with 36 Heavy Duty Prewash High Temperature Rack Conveyor Dishwashing Machine with

MODEL 86 PW MODEL 86 PW RACK CONVEYOR STANDARD FEATURES SPECIFIER STATEMENT. Project Item No. Quantity

84 Series 84, 106 PW, 110 FFPW, 120 HDPW High-Temperature Rack Conveyor Dishwashing Machine

FT1000 FLIGHT-TYPE DISHWASHER

FT1000S BASE FLIGHT-TYPE DISHWASHER

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

FT900BD FLIGHT-TYPE DISHWASHER

FT900 FLIGHT-TYPE DISHWASHER

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

FT900S FLIGHT-TYPE DISHWASHER

FT900D DUAL RINSE FLIGHT-TYPE DISHWASHER

FT1000e ENERGY RECOVERY STEAM WITH BLOWER DRYER Flight-Type Dishwashing Machine. FT SERIES FT1000e ENERGY RECOVERY STEAM WITH BLOWER DRYER

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

FT900S FLIGHT-TYPE DISHWASHER

FT1000 ENERGY RECOVERY STEAM WITH BLOWER DRYER Flight-Type Dishwashing Machine FT SERIES FT1000 ENERGY RECOVERY STEAM WITH BLOWER DRYER

FT SERIES FT1000e ELECTRIC

FT1000S ENERGY RECOVERY STEAM Flight-Type Dishwashing Machine FT SERIES FT1000S ENERGY RECOVERY STEAM STANDARD FEATURES SPECIFIER STATEMENT

B-US 281 LPW HOT WATER SANITIZING FLIGHT-TYPE WAREWASHERS. Standard Features: Options:

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

Models. Options. Standard Features. LoH 2 O

CLPS86eN-BAS DISHWASHER

CL64T INDUSTRIAL TOTE WASHER

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

CLPS66e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

CL64eN-BAS DISHWASHER

STERO SCT-94SC/108SC/120SC CONVEYOR SERIES

Installation Manual. Manual P/N rev. B. PRO Series Standard Rack Conveyor Dishwashers LISTED. Models.

CL44eN-BAS DISHWASHER

April 1, Price List Schedule. Effective. Page

November 1, Price List Schedule. Effective. Come see our website at.

CL64eN-EGR ENERGY RECOVERY/CL64eN-ADV DISHWASHER

C44A/C44AW DISHWASHER

CLPS66eN-EGR ENERGY RECOVERY/CLPS66eN-ADV DISHWASHER

Installation Manual. PRO Series Ventless Heat Recovery Rack Conveyor Dishwashers LISTED.

JFT Flight Machine. JFT Flight Machine. Models. Options. Standard Features. JFT Flight Machine

Standard Features. Performance/Capacities

CLCS76eN-BAS DISHWASHER

CLCS76eN-EGR ENERGY RECOVERY DISHWASHER

H O B A R T F T F L I G H T - T Y P E W A R E W A S H E R. Energy efficient. Water efficient. Cleaning efficient. So you re efficient.

Installation/Operation Manual with Service Replacement Parts. E 2 series High Temperature Upright Conveyor Dishwasher. Models:

Operation. Operation. Hood-type High Temperature Dishwasher LISTED. Model: DH5000 Series

UW50 UTENSIL/PAN WASHER

Operation, Cleaning and Maintenance Manual

Conveyor. AJ-44 Vision Series. Standard Features. Power/Connections. Performance/Capacities

K-400 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR DISHWASHERS

K-86 SERIES HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR WAREWASHERS. Standard Features: Exclusive Features: Options: Models:

K-86 SERIES. Exclusive Features: Standard Features: ENERGY STAR Qualified. Options: Models:

Operation, Cleaning, and Maintenance Manual

K-66 SERIES HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR WAREWASHERS. Standard Features: Exclusive Features: Options: Models:

K-66 SERIES. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR DISHWASHERS

LXGeR and LXGePR GLASSWASHER

VENTLESS DOOR-TYPE DISHWASHER

The clean solution HOT WATER SANITIZING MULTIPLE-TANK FLIGHT TYPE WAREWASHERS B-M74 SERIES. Special Features: Standard Features: Optional Features:

K-76 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR DISHWASHERS

Machine Serial No. Technical Manual. International Door Dishwasher. February, 1998 Manual P/N Rev.A

With (FFPR26) Basic With (PR22) With (PR36) 26" Front Feed Model 22" Prewash 36" Prewash Prewash

K Tronic Series Installation and Start Up Checkout Procedure.

Installation Manual. PRO Series. Ventless Heat Recovery Rack Conveyor Dishwashers. Models PRO-VHR 80 PRO HD-VHR

Technical Manual. June, Undercounter Dishwasher. Machine Serial No. Model UH-200B UH-200 UH-100B UH-100 UL-100

Tall Hood-type Dishwashers

K-64 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR DISHWASHERS

LXeR and LXePR HOT AND COLD

hinged tops or hinged doors.

UNDERCOUNTER DISHWASHER

Installation/Operation Manual with Service Replacement Parts

The clean solution HOT WATER SANITIZING MULTIPLE-TANK RACK CONVEYOR WAREWASHERS K-M54 SERIES. Special Features: Standard Features: Optional Features:

Version 7 1/ LX

Version 7 1/ LXP

Installation/Operation Manual with Service Replacement Parts

K-44 SERIES. The clean solution. Special Features: Standard Features: Options: Models: HOT WATER SANITIZING SINGLE-TANK RACK CONVEYOR DISHWASHERS

Nu/Clean 624 XL Touch Screen Inline Aqueous Cleaner Technical Specifications & Pricing

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

GIRTON CABINET WASHER MODEL 794A

STARTER SHELVING UNITS DOCUMENT HOLDER LEDGES

Tall Hood-type Series Dishwasher

Technical Manual. June, Undercounter Dishwasher. Machine Serial No. Model UH-200B UH-200. For machines beginning with Serial no.

STERO SD3. Door-Type Dishwasher MODEL: ML

STERO ER-94S/SC RACK CONVEYOR SERIES

Champion. Technical Manual. The Dishwashing Machine Specialists. Door-Type Dishwasher. Machine Serial No. February, 2003

AM SELECT DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES VOLTAGE. Item # Quantity C.S.I. Section AM15

AM-14/AM-14C DISHWASHERS

COMMERCIAL DISHWASHER 2016 PRODUCT CATALOG

TECHNICAL MANUAL INSTALLATION MANUAL FOR EXPORT UNITS SERVICE MANUAL FOR DOMESTIC UNITS FOR JACKSON MODELS: AJ-86CE AJ-86CGP AJ-86CS

R O T O - J E T O F A M E R I C A C O M P A N Y, I N C.

Tall Hood-type Dishwashers

Product Reference Catalog

BASIL 6000 TUNNEL CAGE WASHER

! ATTENTION INSTALLER! THIS DISHWASHER IS EQUIPPED WITH A CONDENSATE REMOVAL VENT SHROUD WHICH WAS SHIPPED SEPARATELY IN ITS OWN PACKAGING.

High Temperature Undercounter Dishwasher

UW50 UTENSIL WASHER MODEL. FORM Rev. J (July 2013) (Electric machines only)

LXe HOT AND COLD HOT AND COLD MODELS STANDARD FEATURES ACCESSORIES STANDARD VOLTAGES OPTIONS AT EXTRA COST. Item # Quantity C.S.I.

CLe-series Dishwashers

MODEL CMA-180UC INSTALLATION & OPERATION Rev 1.17A

Champion. Technical Manual. The Dishwashing Machine Specialists. Door-Type Dishwasher. Machine Serial No. June, 1998

JFT SERIES INSTALLATION, OPERATION, AND SERVICE MANUAL RACKLESS CONVEYOR FLIGHT-TYPE DISHMACHINES. JFT Series Manual S

COMMERCIAL KITCHEN MACHINERY PRICE LIST

Transcription:

STANDARD FEATURES NEW Factory authorized startup ENERGY STAR Qualified (EUCCW6 & EUCCW8 only) Exclusive Dual Technology All-purpose 9" wide peg belt Dish capacities up to 15,07 dishes per hour (NSF Certified) Automatic tank fill Chemical dispensing equipment connection provisions Choice of tank heat: electric, steam coils or direct steam injectors Common hot water connection Common drain connection Common electric connection (separate connection required for optional electric booster and blower-dryer) One piece stainless steel wash/rinse manifold system, easy to remove Door safety switch Electric eye energy sentinel (idle pump shut-off) Easy-to-reach top-mounted controls Heavy-gauge stainless construction Low-water tank heat protection Push-button start-stop station load end Recirculating flushing nozzles load end with prewash saver device Conveyor shut-off shelf unload end Stainless steel enclosure panels front & ends Vent fan control connection provided OPTIONAL WORLD ASS FEATURES Heat Recovery redirects lost steam to heat using less energy Project Item No. Quantity EUCCW SERIES Dual SPECIFIER STATEMENT Photo is for general visual representation only. Please refer to specifications for the latest detailed product information. Specified unit will be Champion model EUCCW4, EUCCW6 or EUCCW8 upright 9" conveyor water saver dishwashing machine. Features automatic tank fill, chemical dispensing connection provisions, common water, drain and electrical connections, door safety switch, low water tank heat protection, rinse saver. 1 year parts and labor warranty. EUCCW SERIES UPRIGHT CONVEYORS The Dual feature offers the Lowest Water/Utility/Chemical Consumption as low as 57 GPH usage while circulating as much as 400 gallons of water for Consistently Good Results CH104 674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 Tel: 905-56-4195 Fax: 905/56-4618 (pdf) 1/15 Champion Industries, Inc. 765 Champion Boulevard, Winston-Salem, NC 7105 Tel: 6/661-1556 Fax: 6/661-1979 www.championindustries.com Champion, an Ali Group Company

Dual EUCCW4 9" [991] 18-5/8" [47] 1" [05] MODULAR SECTIONS: Right to Left Operation 9'-4" - [845] 5'-8" [177] '-1" [65] 1'-10" [559] Dimensions shown in inches and [millimeters] 1 9" [77] 6" [15] 7-1/4" [946] 6-1/4" [159] 4' [119] Overall Length C 1-1/" [800] For Screen Removal B Unload 4' [119] A Load ' '-6" 4" [10] [610] [76] 4" [10] 5-1/" 1 [140] 1" [05] 6" [914] 1/ Dual 0. Prewash 1 19" [48] 8" [965] 100" [540] Door Removal 95" [41] Doors Up 6" [1575] Machine Height 10-1/" [66] TABLE A - Machine Connection Machine Only - Electric Heat 40 F/ C Rise 10kW Electric Built-in Booster 08/60/ 8 5 5 40/60/ 6 0 0 480/60/ 1 15 15 TABLE B - Booster Connection 08/60/ 171 00 00 40/60/ 149 175 175 480/60/ 74 90 90 Machine-steam 08/60/ 1 5 5 70 F/9 C Rise - 18kW Electric Built-in Booster 08/60/ 50 70 70 40/60/ 4 60 60 480/60/ 0 0 Contact Factory for additional voltages. 1-5/8" [41] 40/60/ 18 5 5 480/60/ 10 15 15 Start/Stop Notes: Load Section (A) Standard 5', contains 0" Prewash Prewash also available in a 48" HD section Non-standard load section available in 1" increments load length 5' (includes 0" prewash) Unload Section (B) Standard 5 ft contains 4" Aux. and 6" belt, available in 1" increments Built in electric booster requires a 5' minimum unload Built in steam booster requires a minimum 6' unload Blow dryer section adds 4' to overall length of machine Champion Industries, Inc., 765 Champion Boulevard, Winston-Salem, NC 7105 6/661-1556 Fax: 6/661-1979 www.championindustries.com 674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 905/56-4195 Fax: 905/56-4618

Dual EUCCW6 9" [991] 18-5/8" [47] 1" [05] MODULAR SECTIONS: Right to Left Operation 11'-4" - [454] 5'-8" [177] Dimensions shown in inches and [millimeters] '-1" [65] 1'-10" [559] 1 6" [15] 9" [77] 7-1/4" [946] 6-1/4" [159] 4' [119] Overall Length C 1-1/" [800] For Screen Removal B Unload 4" [10] ' [610] ' [914] 6' [189] / A Load ' '-6" [914] [76] 4" 5-1/" [10] 1 [140] 1" [05] 19" [48] 100" [540] Door Removal 6" [914] 1/ Dual 0. Power Prewash 1 8" [965] 95" [41] Doors Up 6" [1575] Machine Height 10-1/" [66] 1-5/8" [41] Start/Stop TABLE A - Machine Connection Machine Only - Electric Heat 08/60/ 18 50 50 40/60/ 158 00 00 480/60/ 80 100 100 TABLE B - Booster Connection 40 F/ C Rise 10kW Electric Built-in Booster 08/60/ 8 5 5 40/60/ 6 0 0 480/60/ 1 15 15 Machine-steam 08/60/ 9 40 40 70 F/9 C Rise - 18kW Electric Built-in Booster 08/60/ 50 70 70 Contact Factory for additional voltages. 40/60/ 6 5 5 480/60/ 14 0 0 40/60/ 4 60 60 480/60/ 0 0 Notes: Load Section (A) Standard 5', contains 0" Prewash Prewash also available in a 48" HD section Non-standard load section available in 1" increments load length 5' (includes 0" prewash) Unload Section (B) Standard 5 ft contains 4" Aux. and 6" belt, available in 1" increments Built in electric booster requires a 5' minimum unload Built in steam booster requires a minimum 6' unload Blow dryer section adds 4' to overall length of machine Champion Industries, Inc., 765 Champion Boulevard, Winston-Salem, NC 7105 6/661-1556 Fax: 6/661-1979 www.championindustries.com 674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 905/56-4195 Fax: 905/56-4618

Dual EUCCW8 9" [991] 18-5/8" [47] 1" [05] MODULAR SECTIONS: Right to Left Operation 1'-4" - [4064] 5'-8" [177] Dimensions shown in inches and [millimeters] '-1" [65] 1'-10" [559] 1 9" [77] 6" [15] 7-1/4" [946] 4' [119] B Unload Overall Length C 8' [48] / 1-1/" [800] For Screen Removal A Load ' 4' 4' '-6" 4" [10] [610] [119] [119] [76] [10] 5-1/" 4" 1 [140] 6-1/4" [159] 1" [05] 6" [914] 1/ Dual 0. Power Prewash 1 19" [48] 8" [965] 100" [540] Door Removal 95" [41] Doors Up 6" [1575] Machine Height 10-1/" [66] 1-5/8" [41] Start/Stop TABLE A - Machine Connection Machine Only - Electric Heat 08/60/ 18 50 50 40/60/ 158 00 00 480/60/ 80 100 100 TABLE B - Booster Connection 40 F/ C Rise 15 kw Electric built-in booster 08/60/ 4 60 60 40/60/ 6 45 45 480/60/ 18 5 5 Machine-steam 08/60/ 9 40 40 40/60/ 6 5 5 480/60/ 14 0 0 70 F/9 C Rise 5 kw Electric built-in booster 08/60/ 70 90 90 40/60/ 60 80 80 480/60/ 0 40 40 Contact Factory for additional voltages. Notes: Load Section (A) Standard 5', contains 0" Prewash Prewash also available in a 48" HD section Non-standard load section available in 1" increments load length 5' (includes 0" prewash) Unload Section (B) Standard 5 ft contains 4" Aux. and 6" belt, available in 1" increments Built in electric booster requires a 5' minimum unload Built in steam booster requires a minimum 6' unload Blow dryer section adds 4' to overall length of machine Champion Industries, Inc., 765 Champion Boulevard, Winston-Salem, NC 7105 6/661-1556 Fax: 6/661-1979 www.championindustries.com 674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 905/56-4195 Fax: 905/56-4618

Dual Shipping weight crated: 150 lbs./ft.[68kg./m.] Height with doors up: 95" Height to remove doors: 100" SPECIFICATIONS Capacities EUCCW4 EUCCW6 EUCCW8 Dishes per hr. (NSF rated) 9,965 1,445 15,07 Conveyor speed (ft./min.) 6. 8.5 9.5 Motor horsepower Drive 1/ Hp 1/ Hp 1/ Hp Prewash 0" [76] 1 Hp 1 Hp 1 Hp Prewash 48" [119] Hp Hp Hp Hp Hp Hp Power * N/A Hp Hp Auxiliary 1/5 Hp 1/5 Hp 1/5 Hp Water consumption Gal. per hr. (max. use) 58 57 58 Temperatures F (min.) 160 150 150 Power (min.)* N/A 160 160 Auxiliary (min.) 165 165 165 Final rinse (min.) 180 180 180 Heating Tank heat Steam Electric tank 15 lbs./hr. 5 kw tank (EUCCW4) 5 lbs./hr. 45 kw tank * 100 lbs./hr. 0 kw Auxiliary rinse 50 lbs./hr. 10 kw Electric booster 10 10 10 (kw required for 40 F rise) Electric booster 18 18 18 (kw required for 70 F rise) Steam booster 50 50 50 (lbs./hr. required for 40 F rise) Steam booster 90 90 90 (lbs./hr. required for 70 F rise) Venting CFM, load end 00 CFM, unload end 800 *EUCCW4 has no power rinse tank Booster connections may vary. Contact the Factory. Standard Voltages (Specify choice): 08/60/, 40/60/, and 480/60/. Available in -phase only. For non-standard -phase voltages, contact the Factory. Notes Because of the variation in house-supplied water pressure, a water pressure regulating valve (PRV) is needed (water PRV is standard with a booster). Steam PRV s may be required for pressure higher than 0 psi. The PRVs can either be purchased from Champion or obtained locally. Utilities EUCCW4 1 Electrical Connection A Machine connection (see table A) B Booster connection (see table A) Hot Water /4" NPT 180 F hot water connection. (For machine without built-in booster) Drain " NPT connection, 6 gpm max flow rate 4 Vents A Load end: 00 CFM 1/4" S.P. B Unload end: 800 CFM 1/4" S.P. With blower-dryer, increase room ventilation by 600 CFM. Utilities EUCCW6 1 Electrical Connection Contact factory for specific machine electrical requirements NOTE: Electric booster connection contact Factory Hot Water /4" NPT 180 F hot water connection. (For machine without built-in booster) Drain " NPT connection, 6 gpm max flow rate 4 Vents A Load end: 00 CFM 1/4" S.P. B Unload end: 800 CFM 1/4" S.P. With blower-dryer, increase room ventilation by 600 CFM. Utilities EUCCW8 1 Electrical Connection Contact factory for specific machine electrical requirements NOTE: Electric booster connection contact Factory Hot Water /4" NPT 180 F hot water connection. (For machine without built-in booster) Drain " NPT connection, 6 gpm max flow rate 4 Vents A Load end: 00 CFM 1/4" S.P. B Unload end: 800 CFM 1/4" S.P. With blower-dryer, increase room ventilation by 600 CFM. Warning and electrical connections should be made by qualified personnel who will observe all the applicable plumbing, sanitary, safety codes and the National Electrical Code. Note Water Hammer Arrestor (meeting ASSE-1010 standard or equivalent) to be supplied (by others) in common water supply line at service connection. Venting Notes Fabricated duct size: -7/8" x -7/8" (outside dimensions) Champion Industries, Inc., 765 Champion Boulevard, Winston-Salem, NC 7105 6/661-1556 Fax: 6/661-1979 www.championindustries.com 674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 905/56-4195 Fax: 905/56-4618 Champion, an Ali Group Company

UPRIGHT CONVEYOR EUCCW SERIES Dual Control Panel OPTIONS & ACCESSORIES Tank heat; choices of electric, steam coil or steam injectors Booster Heaters stainless steel (completely inter-plumbed, controls are inter-wired) Electric: (40 F rise or 70 F rise) Steam: (40 F or 70 F rise) 48 Blower Dryer, electric or steam (add 4 to overall length) Belts: standard peg belt, flat belt, thermal tray belt, silverware belt, belts with upper cross rods, and other select combination belts Start/Stop station, unload end Back panels, stainless steel Cold water thermostat (for pre-wash) External scrap bucket on 48 pre-wash (standard on 0 pre-wash) External scrap bucket on wash tank Insulated hoods, lower panels Motor pumps, or Hp optional in lieu of 1 Hp on pre-wash Bumper rail, machine mounted Steam pressure regulating valve (unmounted Drain water tempering kit (mounted) Insulated hinged door Digital Gauges Heat Recovery Redirects lost steam to heat using less energy. Water leaves booster at 180 F+ and travels to final rinse arms Booster Heated 110 F water travels back to booster 60 F incoming water to machine. Shock arrestor (water) Drain interlocks Heat Recovery Unit redirects lost steam to heat using less energy NEW Champion ION scale prevention system Champion Industries, Inc., 765 Champion Boulevard, Winston-Salem, NC 7105 6/661-1556 Fax: 6/661-1979 www.championindustries.com 674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 905/56-4195 Fax: 905/56-4618