earth safe Fuel Systems for Critical Power

Similar documents
Mission Critical. Fuel Supply Systems

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

OTC, OTM and OTI Series Options Index for PLC Control Systems:

Condensate Boiler Feed Water Make-Up

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

CAREL heatersteam Electric Element Steam Humidifiers

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

DigiTemp. Digital Water Tempering System. PVI.com

ENGINE GENERATORS AND ACCESSORIES

Revitalize Building Mechanical Systems (4619)

SEQUENCE OF OPERATIONS

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Project Name: Location: Engineer: Contractor: I. GENERAL

Domestic. Pump Series CB and CBE Condensate Units SINGLE OR DUPLEX 1,000 THRU 140,000 SQ. FT. EDR-250 THRU 34,748 LB./HR.

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

Water Piping and Pumps

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

STEP 1: SELECT A NITROGEN GENERATOR STEP 2: SELECT A VENT STEP 3: SELECT MONITORING EQUIPMENT STEP 4: CONTACT ECS

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

SECTION HEATING BOILER FEEDWATER EQUIPMENT

Hubbell NX500 High Efficiency Gas Condensing Water Heater

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

.2 Section Waste Management and Disposal.

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

SPECIFICATIONS MODEL EHV X VACUUM OIL PURIFIER

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

SECTION PACKAGED HEAT TRANSFER SYSTEM

OPERATING MANUAL. Reverse Osmosis Equipment Model: Frame Mount Vertical FMV-1 through FMV-6. Made in U.S.A.

Liebert CSU3000 Chiller

water source / fan coils

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

SECTION STEAM CONDENSATE PUMPS

BuildingName The Description of the Project P DOCUMENTS

Stainless Steel Condensate Return Units

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

MODEL B2 INSTALLATION MANUAL

Models. Options. Standard Features. LoH 2 O

PURGE/PRESSURIZATION SYSTEM

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Sequence of operation

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

The EnduroTi HIGH MASS. Superior Construction: COMMERCIAL CONDENSING BOILER. Stainless Steel Titanium Blend. 10 : 1 Turndown Ratio

Power Flame Incorporated

EZ Plate Instantaneous

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Installation, Operation and Maintenance Manual

Superior Temperature Control. world of innovation

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

SECTION SAMPLE SPECIFICATION FOR BOILER CONTROLLER CONVERSION KIT

Superior Temperature Control. world of innovation

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

Originators of the Flexible Water Tube design

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

Date: Project #: Engineer: Prepared By: Bid Date:

SYSTEM DESIGN REQUIREMENTS

Wilo IL Vertical Split-Coupled Inline Pumps

Proudly assembled in U.S.A

Model 4880 Status Output Display Module Manual

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

Proudly assembled in U.S.A

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Heat Transfer Packages

TM Series. Induced Draft, Counter Flow Optional Accessories

PROBATCH MODEL H. Optimize Your Polymer Performance

Owner s Manual Therma-Stor II Heat Recovery System

Control and power circuit fusing to meet N.E.C.

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

SVENMIX.D DRY POLYMER MIXING SYSTEM

PACKAGED AIR COOLED Product Data Catalog

Operations Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

WaterFurnace FX10 Application Guide Reversible Chiller

Commercial Semi-Instantaneous Water Heaters

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

OACS Outdoor Air-Cooled Central Chillers

OTC, OTM and OTI Series Options

SCAN200E USER S MANUAL

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

CCH/CCW, VFC/VFW, MHC/MHW, LVC/LVW

A. Detail drawing M1 Standard Chilled Water Schematic 1.03 DESCRIPTION OF THE PULLMAN CAMPUS CENTRAL CHILLED WATER LOOP SYSTEM:

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

Installation and Operation of AST Equipment. Presenter: Steve Allwein Northeast Regional Sales Manager Morrison Bros. Co.

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

Condensate Return Feedwater Systems For Low and High Pressure Steam Boilers

Transcription:

BACnet, Modbus, Metasys N2, or LON Communications General Description Safe Fuel Storage Inside Buildings. Earthsafe day tanks safely store fuel for generarator engine consumption within the building. Day tanks are designed with integral secondary containment. Fuel transfer equipment and controls are designed for safe and reliable re-filling. Reliable Refill Systems. Day Tanks are designed and furnished with pre-assembled and tested fuel transfer equipment and controls. Inlet control valves, transfer pumps, level sensors, leak sensors, and other equipment are all monitored and controlled by the Earthsafe OmniPlex or CentraPlex control panels. Integrated Building Management Systems. Earthsafe advanced controllers allow for the communication of vital day tank operating information to other building systems. These systems may include Building Automation Systems, generator controls, switchgear and other power controls, security and fire alarm systems. Readily Adaptable for Special Operation. Earthsafe day tanks can be readily adapated for special operation characteristics such as: dual inlet valves, monitored valve positions, high level / overflow pumping, emergency evacuation, auto-commissioning, fluid metering, high temperature control.

Page 2 M510 Generator Day Tank (Inlet Flow Valves) M520 Generator Day Tank (Transfer Pumps) M530 Generator Day Tank (Return Pumps) Dimensions (Capacity) Approval Flow Control Level Control Optional Safety Optional Return Pump Accessories Construction Controls 30 L x 18 W x 60 H (50 GAL) 760x380x1520 (200L) 30 L x 30 W x 60 H (100 GAL) 760x760x1520 (400L) 30 L x 48 W x 60 H (150 GAL) 760x1220x1520 (600L) Capacities up to 1000 Gallon (4000L) UL 142 Dual 0.50 (12) Inlet Solenoid Valves for Remote Pump, or Dual on-board Fuel Transfer Pumps (5 GPM) 20 LPM 5 Point Level Sensor: High Fill Stop Fill Start Low Critical Low Inlet NO Solenoid Valves Vent High Level Switch Single or Dual Pumps Viking Close Coupled Pump 10 15 20 GPM (40-60-80LPM) TEFC Motor 1750 RPM 120/240-1PH 0r 240/480-3PH Inlet Solenoid Valves Inlet Manual and Bypass Valves Inlet Strainers Outlet (to engine) Manual Valves Leak Sensor Direct Read Gauge Inspection Port Std and Emer Vents Welded Steel Construction Containment Basin 150% Industrial Enamel Finish Color RAL 7035 (Light Gray) Option: Weatherproof Enclosure C850 OmniPlex Module

Page 3 Day Tank Dual Inlet Valves Day Tank with Dual Inlet Valves The control panel monitors the tank level sensors, which are approximately 90% High Level, 85% Fill Stop, 75% Fill Start, 50% Low Level, and 25% Critical Low level. Upon receipt of the Fill Start signal, the control panel closes an output relay to send a pump on / fuel request signal to the remote fuel transfer pump. Simultaneously the lead inlet solenoid valve is energized to open. Upon receipt of the Fill Stop signal, the pump on / fuel request signal ceases, and the inlet solenoid valve de-energizes to close. At Low Level the control panel energizes the lag inlet solenoid valve. The inlet solenoid valves automatically alternate upon starts. 1 1 OmniPlex Control Panel 14 1 High Level Sensor 20 2 Solenoid Valve NC 30 1 Day Tank UL 142 31 1 Tank Containment 40 1 Emergency Vent 42 1 Inspection Port 51 3 Ball Valve 54 2 Strainer Add for Return Flow Pump Option 44 1 Foot Valve 51 1 Ball Valve 52 1 Check Valve 53 2 Flex Connector 60 1 Pump Return Flow High. Low, and Critical Low Level signals activate and alarm signal and message. The High Level alarm disables the operation of the system in the MAN mode. The system monitors independent Critical High Level, and Tank Leak sensors. Activation of these sensors disable to tank fill operation in either MAN or AUTO mode. The display indicates: (a) normal or alarm condition, (b) fill active status, (c) alarm indication for critical high, high, low, critical low, and leak alarms, (d) optional % full or gallons. A common alarm output relay and a serial data interface are provided for BMS integration. Optional Return Flow Pump: In the AUTO mode the pump is activated by the high level signal. The pump operates until the high level signal ceases, plus a 60 second stop delay to prevent short cycling.

Page 4 Day Tank Inlet Valve with High Stop 1 1 OmniPlex Control Panel 14 1 High Level Sensor 20 1 Solenoid Valve NC 21 1 Solenoid Valve NO 30 1 Day Tank UL 142 31 1 Tank Containment 40 1 Emergency Vent Day Tank with High Stop Valve 42 1 Inspection Port The control panel monitors the tank level sensors, 51 2 Ball Valve which are approximately 90% High Level, 85% Fill 54 2 Strainer Stop, 75% Fill Start, 50% Low Level, and 25% Critical Low level. Upon receipt of the Fill Start signal, the control panel closes an output relay to send a pump Add for Return Flow Pump Option on / fuel request signal to the remote fuel transfer pump. Simultaneously the inlet solenoid valve is energized to open. Upon receipt of the Fill Stop 44 1 Foot Valve signal, the pump on / fuel request signal ceases, and the inlet solenoid valve de-energizes to close. High. Low, and Critical Low Level signals activate and alarm signal and message. The High Level alarm disables the operation of the system in the MAN 51 52 53 60 1 1 2 1 Ball Valve Check Valve Flex Connector Pump Return Flow mode, and energizes the Normally Open Fill solenoid valve to close. The system monitors independent Critical High Level, and Tank Leak sensors. Activation of these sensors disable to tank fill operation in either MAN or AUTO mode, and energizes the Normally Open Fill solenoid valve to close. The display indicates: (a) normal or alarm condition, (b) fill active status, (c) alarm indication for critical high, high, low, critical low, and leak alarms, (d) optional % full or gallons. A common alarm output relay and a serial data interface are provided for BMS integration. Optional Return Flow Pump: In the AUTO mode the pump is activated by the high level signal. The pump operates until the high level signal ceases, plus a 60 second stop delay to prevent short cycling.

Page 5 Day Tank Dual Transfer Pumps 1 1 OmniPlex Control Panel 14 1 High Level Sensor The control panel monitors the tank level sensors, which are approximately 90% High Level, 85% Fill Stop, 75% Fill Start, 50% Low Level, and 25% Critical Low level. Upon receipt of the Fill Start signal, the control panel closes an output relay to activate the lead fuel transfer pump. Upon receipt of the Fill Stop signal, the pump on / fuel request signal ceases, and the fuel transfer pump stops. At Low Level the control panel energizes the lag fuel transfer pump. The fuel transfer pumps automatically alternate upon starts. High. Low, and Critical Low Level signals activate and alarm signal and message. The High Level alarm disables the operation of the system in the MAN mode. The system monitors independent Critical High Level, and Tank Leak sensors. Activation of these sensors disable to tank fill operation in either MAN or AUTO mode. 30 1 Day Tank UL 142 31 1 Tank Containment 40 1 Emergency Vent Day 42 Tank with 1 Dual Fuel Inspection Supply Port Pumps 51 2 Ball Valve 54 2 Strainer 61 1 Pump Day Tank Supply Add for Return Flow Pump Option 44 1 Foot Valve 51 1 Ball Valve 52 1 Check Valve 53 2 Flex Connector 60 1 Pump Return Flow The display indicates: (a) normal or alarm condition, (b) fill active status, (c) alarm indication for critical high, high, low, critical low, and leak alarms, (d) optional % full or gallons, (e) pump status. A common alarm output relay and a serial data interface are provided for BMS integration. Optional Return Flow Pump: In the AUTO mode the pump is activated by the high level signal. The pump operates until the high level signal ceases, plus a 60 second stop delay to prevent short cycling.

Page 6 GenCentric Unit 3 1 VFD Pump Drive 36 1 GenCentric Unit 42 1 Inspection Port 59 1 GenCentric Float Valve GenCentric Day Tank The GenCentric unit is fed fuel from a continuously maintained low pressure fuel header supplied by VFD pumps. The precision mechanical float valve within the unit allows re-fill of the tank as the fuel is consumed. A high level condition causes the vent float valve to close, pushing excess fuel through the return flow pipe and back to the storage tank. The level switch for Critical High, High, Low, and Critical Low Alarms plus the leak switch are integrated directly to the generator control panel. Earthsafe Systems, Inc. 7320 S. Madison Willowbrook, IL 60527 T: (630) 794-5100 info@earthsafe.com F: (630) 794-5106 www.earthsafe.com