MP 2401 E, MP 1801 Z, MP 1201 T

Similar documents
Operation Manual. Diaphragm pumps 2-headed. Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep

Operation Manual. Diaphragm pumps. MP 054 Zp, MPC 054 Zp MP 104 Ep, MPC 104 Ep

Diaphragm pump 4 - headed

Diaphragm pumps. Operation Manual. Models: 2019C-02 (230V / 50Hz) 2019B-01 (115V / 60Hz) 2019C-50 (230V / 50Hz)

Operation Manual. Scroll pumps. Dry Run II

Operation Manual. Scroll pumps. Types scrollvac S 10 scrollvac S

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

transport handle gas ballast valve robust design for long life easy to clean integrated oil level window quiet running, minimized vibrations

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

Rotary vane vacuum pumps Two-stage

Laboport Chemically-resistant Laboratory Pumps and Systems

Betriebsanleitung Operating Instructions

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

HEAT RECOVERY AIR HANDLING UNIT

Waste water ejection unit

Original Operating Instructions V-VTE

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar abs) Press. (bar g) (kg)

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

Original Operating Instructions V-VC

Chemical resistant Vacuum Pumps

VC-1, VC-1-SL, VC-2-L, VC-2-SL

DIAPHRAGM PUMP OEM KNF /18 N TRANSLATION OF ORIGINAL OPERATING AND INSTALLATION INSTRUCTIONS ENGLISH

LABOPORT. Chemically-resistant Laboratory Pumps with Modular Accessories. Operating Instructions for Laboratory Pumps. and for LABOPORT Systems

Oil-Sealed Rotary Vane Pumps

OPERATING MANUAL English Chemical Resistant Diaphragm Pump

APPLIED VACUUM TECHNOLOGY VACUUM PUMPS & SYSTEMS

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Operating Instructions

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

Dry, oilfree Diaphragm Pumps

Dry, oilfree Diaphragm Pumps. Highlight NEW MPC 302 Z. 3 Diaphragm Pumps

HD Kompakt Service Manual

All-Metal Control Valve

USER S MANUAL ATH WH220

TTV 4500 / TTV 4500 HP / TTV 7000

Mechanical seals external, single or double, to DIN EN 12756

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

p Permanent magnet water cooled motors Additional manual

High Output Vacuum/Pressure Pump

Betriebsanleitung Operating Instructions. Diaphragm Pumps

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

Operating Instructions

Operating instructions DULCO flex DFDa Peristaltic Pump

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

568X, 587X, 588X Series

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

TEMPERATURE-RESISTANT AND HEATED DIAPHRAGM GAS SAMPLING PUMPS

Safe, precise and cost-effective dosing with ProMinent Low-pressure dosing pumps up to 1,000 l/h

Chemistry diaphragm pumps

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

Operating instructions

KESSEL Grease separator EasyClean free Standard, Direct - oval in NS 2, 4, 7, 10, 15, 20, 25, 30 for set-up in frost-free rooms

GLEB Kitchen exhaust fan

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

FSW300 Series Flow Switch

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

AC6/6H & AC8/8H Horizontal Metric Models

Operation Manual R205BV, R209BV

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Instruction Manual Suppository Penetration Tester. Type PM 30

Mechanical Seal RG-4 stationary, double, liquid sealed

Operating instructions

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

Original instructions. Operation Manual & Cautions

USER S MANUAL. VKP Series INLINE FAN

Original Operating Instructions V-VCA / V-VCE

Dosing system. Commissioning and maintenance manual eco-pen300

Installation and operating instructions. DK energy storage and DK energy buffer

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

hp Dust Collector With Vacuum Attachment

Installation and Operating Instructions

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

Models Series Series

User s Guide ENGLISH. Other languages available on our website:

Operating instructions DULCO flex DFDa Peristaltic Pump

Operating Instructions

Operating manual Incl. Manufacturer s declaration. Diffusion pump. with optional baffle DIF 630 BP BE (9803) 1

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

DUST EXTRACTOR MODEL No: CDE1000

Oil burners fuel unit with solenoid valve

Operating Instructions

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

3-way switching valve

Vacuum Controller with Control Unit VC 900

Transcription:

Operation Manual Diaphragm pumps 8-headed Types MP 2401 E, MP 1801 Z, MP 1201 T MPC 2401 E, MPC 1801 Z, MPC 1201 T 400152 2003-10-27

We are constantly working on the further development of all our product types. Reprinting or reproduction of this manual, including extracts, is not allowed without the prior written permission of ILMVAC GmbH. All rights under the copyright laws are expressly reserved by ILMVAC GmbH. We reserve the right to make changes and amendments. ILMVAC GmbH Am Vogelherd 20 98693 Ilmenau, Germany Telephone: +49 36 77 60 40 Fax: +49 36 77 60 41 10 E-mail: info@ilmvac.de Homepage: http://www.ilmvac.de http://www.ilmvac.com

Contents Contents 1 Important Information...4 1.1 General Information...4 1.2 Target Groups...4 1.3 Intended Use...4 1.4 Use for an Unauthorized Purpose...5 1.5 Safety Devices...5 1.6 Meaning of the Warning notes...5 1.7 Product Standards, Safety Regulations...5 2 Basic Safety Instructions...6 2.1 General Information...6 2.2 Electricity...6 2.3 Mechanical Systems...6 2.4 Hazardous Substances...7 2.5 High Temperatures...7 3 Description...8 3.1 Design...8 3.2 Areas of Application...8 3.3 Principle of Operation...8 3.4 Models...9 3.5 Gas ballast...10 3.6 Scope of Delivery...10 3.7 Accessories...10 3.7.1 Accessories optional...10 4 Technical Data...11 4.1 Dimensions...11 4.2 Intake Pressure / Pumping Speed Diagram...11 4.3 Device Data...12 4.3.1 Order Numbers...13 5 Installation and Operation...14 5.1 Unpacking...14 5.2 Installation and Connection...14 5.3 Operation...14 5.4 Storage...14 5.5 Scrap Disposal...14 6 Maintenance and Servicing...15 6.1 General Requirements...15 6.2 Maintenance Performed by the User...15 6.3 Disassembly...16 6.4 Assembly...16 6.5 Test...17 6.6 Maintenance by the Manufacturer...17 7 Troubleshooting...18 8 Spare Parts Overview...19 8.1 Maintenance kit...19 8.2 Diaphragm pump - Exploded view...20 8.3 Complete unit - MP...21 8.3.1 Parts list complete unit MP...22 8.4 Complete unit - MPC...23 8.4.1 Parts list complete unit MPC...24 9 Damage Report...25 400152 3

Important Information 1 Important Information 1.1 General Information The diaphragm pumps conform to the following directives: 93/68/EEC Low Voltage Directive 98/37/EU Machinery Directive 89/336/EEC Electromagnetic Compatibility Directive The CE sign is located on the rating plate. Observe the binding national and local regulations when fitting the pump into installations. Our products are sold worldwide and can therefore be equipped with the typical national plugs and for the various voltages. You will find more information about the available pump designs under http://www.ilmvac.de. 1.2 Target Groups This Operating Manual is intended for the personnel planning, operating and maintaining ILMVAC diaphragm pumps. This group of people includes: Designers and fitters of vacuum apparatus, Employees working on commercial laboratory and industrial vacuum technology applications and Service personnel for diaphragm pumps The personnel operating and maintaining the diaphragm pumps must have the technical competence required to perform the work that has to be done. We recommend that the user appoints the personnel who are to perform this work. The personnel must have read and understood the complete Operating Manual before using the diaphragm pumps. The Operating Manual must be kept at the place of use and be available to the personnel when required. 1.3 Intended Use The layout of the diaphragm pump must be appropriate for the conditions of use. The u- ser bears the sole responsibility for this. The diaphragm pump may only be operated under the conditions stated - in the "Technical Data" section, - on the type plate, and - in the technical specification for the order concerned. Diaphragm pumps are approved for extracting, pumping and compressing gases and vapours. If these gases and vapours are toxic or explosive, then the user must observe the currently valid safety regulations for this application. Special types of diaphragm pumps are available for aggressive and explosive gases. 4 400152

1.4 Use for an Unauthorized Purpose Important Information It is forbidden to use the pump for applications deviating from the technical data stated on the type plate or the conditions stated in the supply contract, or to operate it with missing or defective protective devices. 1.5 Safety Devices Measures such as the following are for the safety of the operating personnel: Operation mode S1 (with grounding connector) Motor protection switch (thermal) and Hot Surface" label on the pump body (warning notice). 1.6 Meaning of the Warning notes Take note of the warning notices. They are in the following box: WARNING! Hazard which may lead to serious injuries or material damage. 1.7 Product Standards, Safety Regulations ILMVAC diaphragm pumps meet the following product standards: DIN EN 292-1, DIN EN 292-2 DIN EN 1012-2 DIN EN 60204-1 EN 50110-1 (DIN VDE 0105-100) Safety of machines, basic terminology Compressors and vacuum pumps Electrical equipment of machines Operation of electrical installations. The following additional safety regulations apply in the FR Germany: BGV A2 VBG 5 BGR 120 BGI 798 Electrical equipment and operating materials Power-driven machines Guidelines for laboratories BG hazard assessment in the laboratory Observe the standards and regulations applying in your country when you use the diaphragm pumps. 400152 5

Basic Safety Instructions 2 Basic Safety Instructions 2.1 General Information Warning notices must be observed. Disregarding them may lead to damage to health and property. The diaphragm pumps must be operated by personnel who can detect impending dangers and take action to prevent them from materialising. The manufacturer or authorized authorised workshops will only service or maintain the diaphragm pump if it is accompanied by a fully completed damage report. Precise information about the contamination (if present) and thorough cleaning of the diaphragm pump are legally binding parts of the contract. Contaminated diaphragm pumps and their individual parts must be disposed of in accordance with the legal regulations. The local regulations apply in foreign countries. 2.2 Electricity Only diaphragm pumps of operation mode S1 are supplied. When the location of operation mode S1 devices is changed, please note that the testing must be repeated in accordance with DIN EN 0105, DIN EN 0702 and BGV A2. The local regulations apply in foreign countries. 2.3 Mechanical Systems Improper use can lead to injuries or material damage. Observe the following instructions: Only operate the diaphragm pumps with hoses of the specified dimensions. The maximum permissible pressure of 1 bar at the suction connection must not be exceeded. Solid particles in the pumping medium impair the pumping action and can lead to damage. Prevent solid particles penetrating into the pump. Hazardous substances must be separated out as far as this is technically possible before they reach the pump. External mechanical stresses and vibrations must not be transmitted to the pump. Only use flexible laboratory hoses for connecting diaphragm pumps. The overpressure generated at the pressure port must not exceed 1 bar. The pump must not be used to suck up fluids. Lay the exhaust pipe so that it slopes downwards, so allowing condensate to flow out of the pump. Collect the condensate and dispose of it in an environmentally compatible manner. Prevent dyes exuding. Maintain a space of least 20 cm between the pump and adjacent parts in order to enable the pump to cool. 6 400152

2.4 Hazardous Substances Basic Safety Instructions The operating company bears the responsibility for the use of the diaphragm pump. Hazardous substances in the gases to be pumped can cause personal injuries and property damage. Pay attention to the warning notices for handling hazardous substances. The local regulations apply in foreign countries. Explosive gases Before switching on, check whether the gas to be pumped is explosive or can form explosive mixtures. In such a case, use a diaphragm pump with an explosion-proof motor. In addition, the following regulations must be observed: Explosion Protection Directive 94/9/EU, EC Directive 1999/92 and the DIN 57165/DIN VDE 0165. Aggressive gases The MPC series is designed for extracting aggressive gases. The use of diaphragm pumps of the series MP cannot be recommended for such cases of application! Poisonous gases Use a separator when pumping poisonous or harmful gases. Prevent such substances from leaking out of the appliance or pump. Treat these substances according to the applicable environmental protection regulations. Test the strength and leak-tightness of the connecting lines and the connected apparatus. Prevent environmental poisons, e.g. mercury, getting into the diaphragm pumps. Fulfil the requirements, for example: German Hazardous Substances Regulation (GefStoffV) of 15 November 1999 Regulations 67/548 EEC and 88/379 EEC (classification, packaging, and identification of substances), 11th GSGV explosion protection regulation (regulation of 12 December 1996 covering putting devices and protective systems on to the market which are intended for areas at risk of explosion) Manufacturer's safety data sheets on hazardous substances. 2.5 High Temperatures The diaphragm pump may heat up as a result of the temperature of the gas being pumped and through intrinsic heating. The temperature of the diaphragm pump heads can reach 70 C during operation. Prevent the following maximum permissible temperatures from being exceeded. + 40 C for the environment, and + 80 C for the gas to be pumped. The motor for single phase alternating current is protected against overload by an integrated motor protection switch. Pumps with EEx design motors do not have any such overload protection. They must be retrofitted by the user with a protective device that is suitable for the relevant use. 400152 7

Description 3 Description 3.1 Design The diaphragm pump consists of a pump body and a drive motor. The pump body consists the in pairs of the A and B-laterally put on eccentric cam drives in the housing as well as put on-pump-cuts back. Each pump head contains a diaphragm and the work valves. Two pairs of pump heads are arranged opposite each other. 1 to 3 stage pumps are supplied, depending upon the circuitry of the pump heads. The pump heads are driven via an eccentric shaft with a connecting rod. Fig. 1 diaphragm pump type MPC 1201 T 3.2 Areas of Application ILMVAC diaphragm pumps are intended for: Pumping and compressing neutral and aggressive gases and vapours. Generating a vacuum down to an ultimate pressure < 2 mbar. Use in physical and chemical laboratories in trade and industry. Use for vacuum filtration, vacuum distillation and vacuum drying, and other vacuum technology applications. 3.3 Principle of Operation Motor, eccentric shaft and connecting rod set the diaphragms in stroke movement. This changes the size of the space between the diaphragms and pump head (pump chamber). Increasing the size of the pump chamber opens the inlet valve while the outlet valve is closed (intake process). Decreasing the size of the pump chamber ejects the gas through the outlet valve. The valves are actuated by the gas being pumped. A large proportion of fluid in the diaphragm pump minimizes the pumping efficiency. 8 400152

Description 3.4 Models Pump head circuitry: One-stage (E): Final vacuum: Types: Four pump heads are connected in parallel. < 75 mbar MP 2401 E and MPC 2401 E Two-stage (Z): Final vacuum: Types: Three pump heads are in parallel, the fourth in series. < 8 mbar MP 1801 Z and MPC 1801 Z Three stage (T): Final vacuum: Types: Two pump heads are in parallel, the other two in series. < 2 mbar MP 1201 T and MPC 1201 T Materials of the medium-affecting pump parts: Component Standard design MP type Chemical model MPC type (resistant to aggressive gases) Cylinder- / pump head Aluminium PTFE with carbon-fibre reinforcing Seal EPDM EPDM Screw fitting PA PVDF Valves PEEK PEEK Diaphragm NBR fabric reinforced with a PTFE layer Connecting elements PP PP NBR fabric reinforced with a PTFE layer Notes: PTFE with carbon-fibre reinforcement, electrically conductive (with manufacturer's certificate of electrical conductivity). Material resistance to aggressive media see: "Plastic, Rubber Products, Annual Handbook of the Processor 2000/2001 ( Kunststoff Kautschuk Produkte, Jahreshandbuch der Verarbeiter 2000/2001), Publisher Hoppenstedt Darmstadt, Vienna, Zurich. Special designs: Special diaphragm pumps can be supplied after consultation with the manufacturer or for a corresponding supply contract. Explosion protection motors in the EEx e and Eex de designs. Motors for different voltages. 400152 9

Description 3.5 Gas ballast When condensable vapours are pumped, they may be compressed above the saturated vapour pressure and condense. Opening the gas ballast valve (1) in the suction line of the last pump stage allows air to flow into the pump chamber. This prevents condensation and flushes the pump clear. (1) Operation leads to: - Increasing the ultimate pressure and - Increasing the operating temperature. Fig. 2 MPC 1201 T with gas ballast valve The gas ballast valve is only provided as standard for MPC type diaphragm pumps. The fitting into other pump types is an option or must be specified in the supply contract. 3.6 Scope of Delivery The scope of delivery is specified in the supply contract. 3.7 Accessories Ventilation valve, Order No. 700187 Electromagnetic valve for venting the apparatus Gas ballast valve, Order No. 400599 For diaphragm pumps of type MP, manually operated Vacuum controller VCZ 324, order no. 600035 3.7.1 Accessories optional Intake pipe valve, Order No. 700186 (intake port valve) solenoid valve for regulating the working pressure in the connected apparatus. Control valve VVB G, Order No. 700301 For measuring and regulating the operating pressure 10 400152

Technical Data 4 Technical Data 4.1 Dimensions The main dimensions are identical for all pump types specified here. (1) (2) (H) (D) (W) 1 - Intake port 2 - Pressure port Fig. 3 Dimensions type MP 2401 E (see point 4.3) 4.2 Intake Pressure / Pumping Speed Diagram Fig. 4 Intake Pressure, Pumping Speed 400152 11

Technical Data 4.3 Device Data Parameter Unit 2401 E (single-stage) Diaphragm pump types 1801 Z (two-stage) 1201 T (three-stage) Pumping performance 50/60 Hz DIN 28432 (at speed of 1500 rpm) Final vacuum (at speed of 1500 rpm) Final vacuum with gas ballast (at speed of 1500 rpm) (with MPC only) m 3 / h 15.5 / 17.0 12.0 / 13.3 8.3 / 9.1 l / min 275 138 mbar < 75 < 8 < 2 mbar 90 18 9 Max. inlet pressure bar 1 Max. outlet pressure bar 1 Intake and pressure ports - Small flange DN 16 KF (optional: Hose nipple for vacuum hose NW 8) Max. ambient temperature C + 40 Max. operating gas temperature Bearing Reference surface sound pressure level DIN 45635 part 13 Voltage / Frequency (Different data upon customer request) C + 80 maintenance-free db (A) < 48 V, Hz AC asynchronous motor 230, 50 (50/60) (generally with motor protection switch, switch and cable) Three-phase asynchronous motor 230/400, 50/60 (generally with motor protection switch, switch and cable) Power kw 0.37 Operating mode S 1 Type of protection DIN EN 60529 Class of insulation DIN EN 600034-1 IP 54 F (160 C) Dimensions (W/D/H) mm 540 / 300 / 240 Weight kg 24.0 Motor in EEx design DIN EN 60034/IEC 34, DIN VDE 0530, DIN EN 50014 to DIN EN 50021 Type of protection: e II T4 and de II c T4 - on request - (Motors are supplied with terminal box but without motor protection switch) 12 400152

Technical Data 4.3.1 Order Numbers Diaphragm pump Voltage/ Frequency Plug Order No. MP 2401 E MPC 2401 E MP 1801 Z MPC 1801 Z MP 1201 T MPC 1201 T 230V, 50Hz CEE 400153 230/400V, 50Hz CEE 400153-02 230V, 50Hz UK 400153-03 230V, 50Hz CH 400153-04 115V, 60Hz US 400153-05 100V, 50/60Hz US 400153-06 230V, 50Hz CEE 400179 230/400V, 50Hz CEE 400179-01 230V, 50Hz UK 400179-02 230V, 50Hz CH 400179-03 115V, 60Hz US 400179-04 100V, 50/60Hz US 400179-05 230V, 50/60Hz CEE 400154 230/400V, 50Hz CEE 400154-01 230V, 50/60Hz UK 400154-02 230V, 50/60Hz CH 400154-03 115V, 60Hz US 400154-04 100V, 50/60Hz US 400154-05 230V, 50/60Hz CEE 400155 230/400V, 50Hz CEE 400155-01 230V, 50/60Hz UK 400155-02 230V, 50/60Hz CH 400155-03 115V, 60Hz US 400155-04 100V, 50/60Hz US 400155-05 230V, 50Hz CEE 400152 230/400V, 50Hz CEE 400152-01 230V, 50Hz UK 400152-02 230V, 50Hz CH 400152-03 115V, 60Hz US 400152-04 100V, 50/60Hz US 400152-05 230V, 50Hz CEE 400178 230/400V, 50Hz CEE 400178-02 230V, 50Hz UK 400178-03 230V, 50Hz CH 400178-04 115V, 60Hz US 400178-05 100V, 50/60Hz US 400178-06 400152 13

Installation and Operation 5 Installation and Operation 5.1 Unpacking Carefully unpack the diaphragm pump. Check the pump for: Transport damage, Conformity with the specifications of the supply contract (type, electrical supply data), Completeness of the delivery. Please inform Ilmvac GmbH without delay if there are discrepancies between the delivery and the contractually agreed scope of delivery, or if damage is detected. Please take note of the general terms of business of ILMVAC GmbH. The pump must be returned in the original packaging in order to make a claim under warranty. 5.2 Installation and Connection 1. Set the diaphragm pump on a flat and horizontal surface. 2. Remove the protective caps on the suction and pressure ports. 3. Prepare the connections. 4. Connect the NW 8 vacuum connector to the suction port. 5. Connect the exhaust pipe to the pressure connection. 6. Connect the diaphragm pump to the electrical supply. 5.3 Operation Observe the basic safety instructions when using the pump. The diaphragm pump is switched on and off at the operating switch. The operating company must install a main switch for pumps with terminal boxes. 5.4 Storage The pumps are to be stored in a low-dust, interior room within the temperature range from + 5 to + 40 C and at a relative air humidity < 90%. Leave the protective elements on the suction and pressure ports. Another equally good protection may be used. 5.5 Scrap Disposal The diaphragm pumps must be disposed of in accordance with the specific national regulations. If the pumps are contaminated, we recommend separating its parts for disposal as follows: Pump body, hose lines and other parts as hazardous waste, (cleaned as scrap or household waste) Motor and power cables as electrical scrap, Plastics go for plastic recycling. 14 400152

Maintenance and Servicing 6 Maintenance and Servicing 6.1 General Requirements The maintenance / inspection interval is around 1,000 operating hours. The bearings of the drive motors and the eccentric shaft are life-long lubricated and so maintenance-free. 6.2 Maintenance Performed by the User WARNING! Only perform the work that is described here, and that which is permitted to be done by the user. All other maintenance and service work may only be performed by the manufacturer or a dealer authorized by him. Beware of the pump parts being possibly contaminated by hazardous substances. Wear protective clothing if there is contamination. Scope of permissible work: Open the pump heads. Inspect the pump chambers, diaphragms and valves. Clean the interior of the pump, change the diaphragms and valves. Tools required: The tool kit, order No. 402100 consists of: Pin type face wrench, adjustable, size 3, Allan key, size 3 (for types MPC), Allan key, size 4 (for types MP), Open spanner, size 17. 400152 15

Maintenance and Servicing 6.3 Disassembly 1. Disconnect the power supply and ensure that it cannot be switched on again. 2. Open the screw clamps of the hoses on the pump body with the SW 17 open spanner. Fig. 5 Disassembly, assembly 3. Remove four machine screws (1) from each pump head with an Allan key, size 4. 4. Lift off the pressure plate (2), the cylinder head (3) and the pump head (6). The valve gasket (5) and diaphragm (8) are now freely exposed. 5. Loosen the diaphragm (8) at the strain washer (7) by turning the size 3 pin type face wrench anticlockwise. 6. Clean the valve gasket (5) and the diaphragm (8) with a soft cloth and acetone. Wear protective gloves! Renew these parts if necessary. Do not clean with compressed air. 6.4 Assembly 1. Place the pump so that the diaphragm is lying in a horizontal position. 2. Use the size 3 pin-type face wrench to tighten the pressure disc (9), the diaphragm (8) and the strain washer (7) with the correct torque of 6-7 Nm. 3. Bring the connecting rod (5) (see fig. 9) and the diaphragm (8) into the central position. 4. Replace the pump head (6). 5. Insert the valve (5) and the O-ring (4). Ensure that they are lying completely flat. Do not insert the burred side facing the sealing surface. Align the cylindrical head flush with the pin. 6. Replace the pressure plate (2) and insert and tighten the 4 machine screws with a torque of 4-5 Nm. 7. Reattach the hose connections with clamping ring screw fittings. 16 400152

Maintenance and Servicing 6.5 Test Connect a vacuum measuring device to the suction connector and measure the ultimate pressure. If the device is working properly, then the figure stated in the technical data must be attained within a maximum of one minute. 6.6 Maintenance by the Manufacturer WARNING! Incomplete or incorrectly completed damage reports may endanger the service personnel! Provide full information about contamination, and clean the pump thoroughly before handing it over to third parties. Repairs and maintenance going beyond the extent of the work described in section 6.2 or reconditioning or modification may only be performed by the manufacturer or authorized workshops. The prerequisites for a handover are a complete and factually correct damage report, and a clean pump. Note: The user shall be liable for the consequences of an incorrect damage report or a contaminated pump. The statements in the damage report are legally binding. 400152 17

Troubleshooting 7 Troubleshooting During the warranty period, intervention in the diaphragm pumps and accessory components may only be made by ILMVAC GmbH. Trouble Cause Action Diaphragm pump does not start The diaphragm pump does not generate a vacuum or only an inadequate one. No power supply to the motor Motor defective Pump body defective Connected apparatus leaks, connecting elements leak Diaphragm pump leaks (pipes or hoses) Pump head Diaphragm defective Valves are dirty Valves defective Diaphragm pump is dirty Electrical system to be checked by a qualified electrician. Exchange by service shop. Exchange or repair by service shop. Identify and seal the leak, replace the seals and hoses if necessary. Check the hose connections between the pump heads, replace the hoses and screwed clamping rings if necessary. Repair by service shop. Repair by the service workshop or the user. Clean condensates and foreign objects out of the valves. Replace valves Cleaning by the service workshop or the user. 18 400152

Spare Parts Overview 8 Spare Parts Overview The spare parts lists contain all the spare parts and all the information necessary for ordering. When ordering, please quote the description, quantity, serial number and order number! 8.1 Maintenance kit Designation Order No. Maintenance kit 402021 The maintenance kit consists of: Designation Piece Order No. O-ring ø 28 x 2 16 829252-2 O-ring ø 12 x 2 20 829217-3 Valve 16 400656 Diaphragm 8 400732 Attention, the number of supplied construction units in the maintenance set corresponds to the maximum need of the series! 400152 19

Spare Parts Overview 8.2 Diaphragm pump - Exploded view Fig. 6 Exploded view - Diaphragm pump without connections 20 400152

Spare Parts Overview 8.3 Complete unit - MP 27 17 10; 11; 15 1g; 25; 26 12; 15 13 16 18 1-7; 14 18 19-24 28 Fig. 7 Complete unit MP 400152 21

Spare Parts Overview 8.3.1 Parts list complete unit MP MP 2401 E MP 1801 Z MP 1201 T Item no. Designation Piece Order No. Piece Order No. Piece Order No. 1 Basic pump complete (consisting of position: 1a 1k) 1 400857 1 400857 1 400857 1a Piston rod 4 400647 4 400647 4 400647 1b Close tolerance spacer 25x35x1 6 824957-1 6 824957-1 6 824957-1 1c Eccentric shaft 1 400742-1 1 400742-1 1 400742-1 1d Ball bearing 6205-2Z 4 824961-5 4 824961-5 4 824961-5 1e Ball bearing 6303-2Z 1 824949-3 1 824949-3 1 824949-3 1f Mass balance 2 400678-1 2 400678-1 2 400678-1 1g Motor 230V; 50/60Hz; 0.37/0.44 kw 1 826390-5 1 826390-5 1 826390-5 - Motor 400/480V; 50/60Hz; 0.37/0.44 kw 1 826390-4 1 826390-4 1 826390-4 - Motor 115V; 60Hz; 0.44 kw 1 826390-7 1 826390-7 1 826390-7 - Motor 100V; 50/60Hz; 0.44 kw 1 826390-10 1 826390-10 1 826390-10 1h Casing 1 2 400640-1 2 400640-1 2 400640-1 1j Casing 2 2 400640-3 2 400640-3 2 400640-3 1k O-ring ø 47.22 x 3.53 2 829269 2 829269 2 829269 2 Diaphragm 8 400732 8 400732 8 400732 3 Valve 16 400656 16 400656 16 400656 4 Pump head 2 8 400643 8 400643 8 400643 5 Cylinder head 1 8 400787 6 400787 6 400787 5 Cylinder head 2 - - 1 400788 1 400788 5 Cylinder head 3 - - 1 400789 1 400789 6 Pressure washer 8 400680 8 400680 8 400680 7 Tightening washer 8 400617 8 400617 8 400617 10 Straight coupling PA; 10 ¼ 16 829931-1 23 829931-1 23 829931-1 11 T-threaded joint PA; 10 10 ¼ 8 829938-3 - - - - 12 Elbow union PA; 10 ¼ - - 5 829900-7 5 829900-7 13 Pebax hose 10 / 8x1 1.4m 710524 1.4m 710524 1.4m 710524 14 O-ring ø 28 x 2 16 829252-2 16 829252-2 16 829252-2 15 O-ring ø 12 x 2 32 829217-3 20 829217-3 20 829217-3 16 Manifold; Al 6 400774-1 10 400774-1 10 400774-1 17 Manifold PP; 3 x ¼ 2 400864 1 400864 1 400864 18 Suction-/pressure port Al; DN 16 KF ¼ 2 710108 2 710108 2 710108 19 Foot complete 1 103503 1 103503 1 103503 20 Spacer distance piece Foot 4 103507 4 103507 4 103507 21 Air duct 1 2 103504 2 103504 2 103504 22 Fan 230V; 50/60Hz 1 829819-3 1 829819-3 1 829819-3 - Fan 115V; 60Hz 1 829819-5 1 829819-5 1 829819-5 - Fan 100V; 50/60Hz 1 829819-6 1 829819-6 1 829819-6 23 Spacer for fan 4 103521 4 103521 4 103521 24 Time controlling VAPU 0003 1 825681 1 825681 1 825681 25 Motor operating condenser 16µF 1 825445 1 825445 1 825445 26 Motor operating condenser 12µF 1 825457 1 825457 1 825457 27 Handle 1 828634 1 828634 1 828634 28 Rubber-metal pad 2 829141-1 2 829141-1 2 829141-1 29 Mains connection cable with : - plug CEE (for 230 V) 1 825881 1 825881 1 828881 - plug CEE (for 400 V) 1 825284 1 825284 1 825284 - plug U 1 825876 1 825876 1 825876 - plug CH 1 825897 1 825897 1 825897 - plug US 1 825896 1 825896 1 825896 22 400152

Spare Parts Overview 8.4 Complete unit - MPC 16 27 17 10; 11; 15 1g; 25; 26 9 13 12; 15 18 1-7; 14 8 18 19-24 28 Fig. 8 Complete unit MPC 400152 23

Spare Parts Overview 8.4.1 Parts list complete unit MPC MPC 2401 E MPC 1801 Z MPC 1201 T Item no. Designation Piece Order No. Piece Order No. Piece Order No. 1 Basic pump complete (consisting of position: 1a 1k) 1 400857 1 400857 1 400857 1a Piston rod 4 400647 4 400647 4 400647 1b Close tolerance spacer 25x35x1 6 824957-1 6 824957-1 6 824957-1 1c Eccentric shaft 1 400742-1 1 400742-1 1 400742-1 1d Ball bearing 6205-2Z 4 824961-5 4 824961-5 4 824961-5 1e Ball bearing 6303-2Z 1 824949-3 1 824949-3 1 824949-3 1f Mass balance 2 400678-1 2 400678-1 2 400678-1 1g Motor 230V; 50/60Hz; 0.37/0.44 kw 1 826390-5 1 826390-5 1 826390-5 - Motor 400/480V; 50/60Hz; 0.37/0.44 kw 1 826390-4 1 826390-4 1 826390-4 - Motor 115V; 60Hz; 0.44 kw 1 826390-7 1 826390-7 1 826390-7 - Motor 100V; 50/60Hz; 0.44 kw 1 826390-10 1 826390-10 1 826390-10 1h Casing 1 2 400640-1 2 400640-1 2 400640-1 1j Casing 2 2 400640-3 2 400640-3 2 400640-3 1k O-ring ø 47.22 x 3.53 2 829269 2 829269 2 829269 2 Diaphragm 8 400732 8 400732 8 400732 3 Valve 16 400656 16 400656 16 400656 4 Pump head 2 8 400705 8 400705 8 400705 5 Cylinder head 1 8 400781 6 400781 6 400787 5 Cylinder head 2 - - 1 400782 1 400782 5 Cylinder head 3 - - 1 400783 1 400783 6 Pressure washer 8 400680 8 400680 8 400680 7 Tightening washer 8 400707 8 400707 8 400707 8 Pressure plate 8 400706 8 400706 8 400706 9 Gas ballast valve 1 400599 1 400599 1 400599 10 Straight coupling PVDF; 10 ¼ 18 829931 24 829931 24 829931 11 T-threaded joint PVDF; 10 10 ¼ 7 829938-2 - - - - 12 Elbow union PVDF; 10 ¼ - - 4 829984 4 829984 13 Vacuum hose PTFE; 10 / 8x1 1.4m 828332 1.4m 828332 1.4m 828332 14 O-ring ø 28 x 2 16 829252-2 16 829252-2 16 829252-2 15 O-ring ø 12 x 2 20 829217-3 20 829217-3 26 829217-3 16 Manifold; Al 6 400774 10 400774 10 400774 17 Manifold PP; 3 x ¼ 2 400864 1 400864 1 400864 18 Suction-/pressure port PP; DN 16 KF ¼ 2 710116 2 710116 2 710116 19 Foot complete 1 103503 1 103503 1 103503 20 Spacer distance piece Foot 4 103507 4 103507 4 103507 21 Air duct 1 2 103504 2 103504 2 103504 22 Fan 230V; 50/60Hz 1 829819-3 1 829819-3 1 829819-3 - Fan 115V; 60Hz 1 829819-5 1 829819-5 1 829819-5 - Fan 100V; 50/60Hz 1 829819-6 1 829819-6 1 829819-6 23 Spacer for fan 4 103521 4 103521 4 103521 24 Time controlling VAPU 0003 1 825681 1 825681 1 825681 25 Motor operating condenser 16µF 1 825445 1 825445 1 825445 26 Motor operating condenser 12µF 1 825457 1 825457 1 825457 27 Handle 1 828634 1 828634 1 828634 28 Rubber-metal pad 2 829141-1 2 829141-1 2 829141-1 29 Mains connection cable with : - plug CEE (for 230 V) 1 825881 1 825881 1 828881 - plug CEE (for 400 V) 1 825284 1 825284 1 825284 - plug U 1 825876 1 825876 1 825876 - plug CH 1 825897 1 825897 1 825897 - plug US 1 825896 1 825896 1 825896 24 400152

9 Damage Report Company Customer s Order No: Type: Type-No: Damage Report ILMVAC GmbH Am Vogelherd 20 D-98693 Ilmenau Telephone: +49 36 77 60 40 Fax: +49 36 77 60 41 10 Date: Warranty: Yes/No Ser-No.: 1. Description of Fault a) Was the pump/ components in use?* yes no b) Which oil was used?* c) Is the pump/ component free of hazardous substances? yes continue at section 3 2. Type of contamination of pump/ component no continue at section 2 a) toxical** yes no b) etching** yes no c) micro-biological** yes no d) explosive** yes no e) radio-active** yes no f) other contaminates** yes no * in rotary vane vacuum pumps and roots pumps ** pumps/ components can only be accepted with proof of correct decontamination or cleaning resp. If agreed the decontamination/ cleaning work can be carried- out at ILMVAC GmbH. Type of contaminates or dangerous process reaction products the pumps/ components were in contact with. 1. 2. 3. 4. 5. Trade name Product name Manufacture 3. Official declaration Chemical description (formula if possible) Hazardclass Measures in case of escape of contaminates First aid in case of accidents I/ we ensure that the data/ information given is correct and complete. The despatch of the pump/ component is performed in accordance with the prevailing law. Contact s name: Phone: Dept.: Fax: Date: Company stamp: Official signature: The repair can only be carried-out, if the Damage Report duly completed is submitted. Otherwise the repair work might be delayed. Our General/ Conditions of Sale apply. 400152 25