IGH FX / IGH FX EC. Heat Recovery Ventilation Unit

Similar documents
TEVHR. Heat Recovery Ventilator

Heat Recovery Units. Heat Recovery Units

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

TEVHR. Heat Recovery Ventilators

TEVHR. Heat Recovery Ventilators

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION

KOMFORT EC DB Suspended heat recovery air handling units

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

Energy. The Energy ducted units have been designed. Heat Recovery Unit

TSEK VHR EC HEAT RECOVERY UNITS

Teknogen. Contents. Air Handling Unit Casing of the Unit Fan / Motor Damper Filter Cells Heating / Cooling Coil...

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Heat and energy recovery ventilators

ECV SP GUE ALO CAT ICAL TECHN

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Limited Lifetime core warranty. 5-year warranty on balance of unit.

HEAT RECOVERY DEVICES

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

VERSO Air Handling Units

NKW. Heater series HEATERS

Topvex SR03, SR04, SR06 Compact Air Handling Unit

Whole Home Heat Recovery Ventilation

European Technical Assessment ETA 17/1007 of 02/05/2018

EHW KH PF HIGH EFFICIENTY AIR CONDITONING UNITS TECHNICAL CATALOGUE

CONTACT US. For more information,

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

Series VENTS VUT R WH ЕС

Package Hygienic Air Handling Units. PHK Series

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

VERSO Air Handling Units

Heat Recovery Unit HERU. web-version

SPECTRACOOL Indoor & Outdoor Air Conditioners

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit)

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

SPECTRACOOL Indoor & Outdoor Air Conditioners

Heating / Air Conditioning Energy Heat Recovery Units ENVIRONMENTAL COMFORT

HEAT RECOVERY UNITS TSEK. Mech-Elec, 41, Hawthorn Road, Western Ind. Est., Dublin 12 Tel:

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

FOUR-HOME-CEILING Ceiling Type Residential Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

INSTALLATION OPERATION MAINTENANCE INSTRUCTION HEAT PUMP HEAT RECOVERY UNITS VHR MODELS

SECTION FAN COIL UNITS

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Air Handlers and Indoor Coils Up to 20 Tons. CB* and C* Models. True performance and rugged durability

Auxiliary Equipment and Accessories

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Topvex SoftCooler TR. Specification data

SAVE VTC 700. Heat Recovery Ventilation Unit

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

ErP. The ErP Directive. New values for fans

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

Compact design & easy maintenance

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic

kw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit

Air handling units Compair. Technical Catalogue

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

DV-PP-L-125 DV-PP-L-150. Noise level [db] Capacity [m3/h]

TEKNOPOOL. Swimming Pool Air Handling Units

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

GHE Dehumidifiers for radiant cooling systems with heat recovery

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

TopMaster Air Handling unit. Technical data

SmartDial. Wireless. User Manual. -en_gb language A004. Document in original

SysAer. An efficient rooftop unit. Chillers & Heat Pumps Water terminals Rooftops Close control Water source heat pumps Direct expansion.

Topvex SF02-SF12 Air Handling Unit

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Air Handling Unit. Air Handling Unit

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

AHU Plus. DX Air Handling Units

Installation, operation and maintenance. Accumulator tank. Acc-tank 500 CU. Acc-tank 500 UB ver: Supersedes:

1. Oxygen Master 2. Oxygen Sensor 3. Oxygen Refresh Stand-Alone 4. Touch button controls 4. Oxygen Refresh Built-In 5.

> ENGLISH VERSION. Instructions HERU 50 HERU / utg 2

LOW STATIC HYDRONIC DUCTED UNIT

HEAT RECOVERY AIR HANDLING UNIT

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

ABOUT US WHO WE ARE? TIME TUNNEL STEPS TO EXCELLENCE FACTS and FIGURES NEW LOGO and SLOGAN CERTIFICATES

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

ROOFMASTER STEF-HT ROOF FAN

Transcription:

Heat Recovery Ventilation Unit

IGH FX / IGH FX EC has been designed to provide energy saving by recovery through heat energy exchangers. IGH FX / IGH FX EC is used in order to increase the quality of interior air in environments such as office, café, dormitory and class. Exhausting the dirty and moist air and recovering the heat energy in interior environments in residences such as bathrooms and kitchen, where the temperature is higher, while providing fresh conditioned air with the help of the recovered heat to the environments such as bedroom or living room, where more oxygen is required. 1. Casing All of the casing has been produced of galvanized sheets of 1 mm, which has been electrostatic furnace painted with color code RAL 7035. 25 mm mineral wool insulation material is used for noise and heat isolation. An aluminium, rectangular duct connections are provided for duct connection. Easier electrical connection can be realized by junction box which present on the body as a standard. A main control panel will be used in applications with electrical heaters and speed setting switches instead of the junction box. 2. Fans IGH FX unit includes double suction radial fans are produced of galvanized sheets with direct drive motor. IGH FX EC unit includes single suction radial fans are produced of PA6 and PP material with EC motor. Each motor have been selected low sound level suitable for speed control. 3. Heat Exchangers Heat exchangers which have been made of aluminum, highly efficient and have a low pressure loss are used in the heat recovery units. 4. Drain Pan and Outlet All models have a condensation pan which is produced from electrostatic furnace painted sheet on galvanized sheet with a thickness of 1 mm as a standard. There is a 1/2 drainage connection at the pan outlets. There are double drain pans at the heat exchanger outlets on the exhaust and fresh air line, where the can be a condensation depending on the weather conditions in summer and winter. 2

5. Filters Easily accessible and cleanable G2 class synthetic fiber based filters are used. There are filters at both the fresh air and the exhaust air inlets. Thus, both the conditioned particles in the air are hold and plate type heat exchangers are protected. F5 class filters are also available as optionally. 6. Electrical Heater and Heater Control (Optional) Depending on the place of use and the need, the electrical heaters can be provided in order to be connected to the fresh air discharges of the Heat Recovery ventilation units with a different size and capacity for each model itself. The resistances have been certified with the CE sign and the resistances have been made of copper pipe. Therefore its resistant to corrosion is high. In addition, there is stage control card inside the heater panel. This card is operating by the main control unit which is present inside the pane mounted onto the device. The heater stages are operated according to the set temperature value and the fan speed. In addition, security control is carried out in 4 different ways. Thus, the necessary measures have been taken against a possible fire risk. The heaters are initiated, if needed, after the fans start during the starting of the device due to the main control unit. When turning off the device, firstly the heaters are disabled, then the heaters are cooled and then the fans are disabled. Thus, the procedure of stopping the device is realized. The exhaust and fresh air fans can optionally be used at different speeds. Heaters are produced as single stage, two stages or three stages depending on their capacities. Casing is produced by galvanized sheet. Electrical heaters are produced in rectangular intersections, suitable for the fresh air outlets of the heat recovery units and are suitable for the flange connection, suitable for the fresh air outlets of the heat recovery units and are suitable for the connection with the flange. 7. Speed Control Based on the changing needs, the speed regulator can be used to set the fan speed and provide some energy saving. 3

Standard Heat Recovery Ventilation Unit There is no electrical heater inside the standard device and no panel and control equipment to be used to use this heater. There is a standard speed switch mounted onto the device which enables the fans to be switched on and off and to be set at low, medium or high cycle. This switch is set to the required setting and thus an air flow as needed has been obtained. One of the basic properties of the device is to provide for the recovery of some of the energy when discharging the inside environment air, depending on interior and outside weather conditions. Thus, the incoming fresh air is conditioned. Heat Recovery Ventilation Unit Application With Electrical Heaters Safety precautions have to be taken in applications with heaters in order to control the resistances and to minimize the risk of fire. Control elements are used for this purpose. IGH FX TECHNICAL SPECIFICATIONS MODEL IGH 01 FX IGH 03 FX IGH 04 FX IGH 06 FX IGH 07 FX IGH 08 FX IGH 11 FX Air Flow (m3/h)* 500 1000 1500 2000 2500 3000 4000 Exhaust Motor Power (W) / (Pieces x Power) 2X92 2X92 2X373 2X373 2X550 2X550 2X745 Filter Class G2/F5* G2/F5* G2/F5* G2/F5* G2/F5* G2/F5* G2/F5* Sound Pressure Level (db)** 49 50 55 54 54 45 53 Voltage (V) 220V 220V 220V 220V 220V 220V 220V Frequency (Hz) 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz Weight (kg) 80 90 100 110 150 170 210 Thermal Efficiency (%) Changes between 50-70% according to environmental conditions IGH FX EC TECHNICAL SPECIFICATIONS MODEL IGH 01 FX EC IGH 03 FX EC IGH 04 FX EC IGH 06 FX EC IGH 07 FX EC IGH 08 FX EC IGH 11 FX EC Air Flow (m3/h)* 500 1000 1500 2000 2500 3000 4000 Exhaust Motor Power (W) / (Pieces x Power) 2x83 2x168 2x168 2x460 2x500 2x500 2x750 Filter Class G2/ F5* G2/ F5* G2/ F5* G2/ F5* G2/ F5* G2/ F5* G2/ F5* Sound Pressure Level (db)** 44 52,5 47,5 54 55 58 61 Voltage (V) 220V 220V 220V 220V 220V 220V 220V Frequency (Hz) 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Weight (kg) 75 85 90 100 135 155 195 Thermal Efficiency (%) Changes between 50-70% according to environmental conditions * F Class Filter as opsional ** External Static Pressure is 0 Pa *** Measured at 1.5 m distance 4

IGH FX Performance 5

6 IGH FX / IGH FX EC

IGH FX EC Performance 7

8 IGH FX / IGH FX EC

9

Dimensions DIMENSIONS (mm) MODEL L W H A B C D E F G IGH 01 FX / IGH 01 FX EC 1000 850 400 215 240 110 240 50 94 67 IGH 03 FX / IGH 03 FX EC 1000 850 400 215 240 110 240 50 94 67 IGH 04 FX / IGH 04 FX EC 1300 1100 460 275 305 110 305 50 116 75 IGH 06 FX / IGH 06 FX EC 1300 1100 460 275 305 110 305 50 116 75 IGH 07 FX / IGH 07 FX EC 1550 1150 500 291 331 163 331 85 155 72 IGH 08 FX / IGH 08 FX EC 1550 1150 500 291 331 163 331 85 155 72 IGH 11 FX / IGH 11 FX EC 1600 1300 580 342 395 190 300 85 175 87 10

Control Equipments; Differential Pressure Switch Temperature Sensor Control Panel Control Card In addition to control equipment, the device needs a control panel, which is located on the body and an auxiliary stage panel, which is located on the heater. These panels are used to drive the resistances and to control the fans and in addition to these procedures, the safety measures are also taken with the control equipment. Main Purpose of Control Equipments; 1. Differential Pressure Switch: Cuts the energy of the heater in case of possible motor malfunctions. 2. Temperature Sensor: Initiates the resistances to operate according to the room temperature. 3. Control Panel: Enables the device to be controlled according to the values required with the help of the panel which has been mounted on site. 4. Control Card: In addition to all the automation and security applications. ELECTRICAL HEATER TECHNICAL DATA MODEL IGH 01-03 FX IGH 01-03 FX EC IGH 04-06 FX IGH 04-06 FX EC IGH 07-08 FX IGH 07-08 FX EC IGH 11 FX IGH 11 FX EC Air Flow (m³/h) 1000 2000 3000 4000 Resistance Power (kw) 3,08 6 8,8 11,6 Pressure Drop (Pa) 6 11 15 19 Voltage (V) 380V 380V 380V 380V Weight (kg) 20 22 23 26 Frequency (Hz) 50 Hz 50 Hz 50 Hz 50 Hz Number of Steps 2 3 3 3 1.Stage Power (kw) 1.76 kw 2.0 kw 2.9 kw 3.4 kw 2.Stage Power (kw) 1.32 kw 2.0 kw 2.9 kw 4.1 kw 3.Stage Power (kw) - 2.0 kw 2.9 kw 4.1 kw Total Power (kw) 3.08 kw 6.0 kw 8.8 kw 11.6 kw 11

ELECTRICAL HEATER DIEMENSIONS (mm) MODEL IGH 01-03 FX IGH 01-03 FX EC IGH 04-06 FX IGH 04-06 FX EC IGH 07-08 FX IGH 07-08 FX EC IGH 11 FX IGH 11 FX EC W* 365 430 456 520 L* 500 500 600 600 H* 265 325 345 395 A** 215 275 291 342 B ** 240 305 331 395 * Flange and electricity box are included in the dimensions. ** Dimensions are of the air intersection inside the duct. Connection flanges are not included. 12

SERVICE SPACE (mm) S IGH 01-03 FX IGH 01-03 FX EC IGH 04-06 FX IGH 04-06 FX EC IGH 07-08 FX IGH 07-08 FX EC IGH 11 FX IGH 11 FX EC 500 600 700 750 * S values; Service space measure as mm. 13

14 Notes

Notes 15

Systemair - Sweden Industrivägen 3-SE 739 30 Skinnskatteberg / Sweden Phone : +46 222 440 00 Fax : +46 222 441 00 Systemair - Turkey Ömerli Mah. İhsangazi Sok. Hadımköy Yolu No: 28 Hadımköy / Arnavutköy / İstanbul / Turkey Phone : +90 212 623 22 10 Fax : +90 212 623 22 15 Head Office, İstanbul - Turkey Phone : +90 212 356 40 60 Fax : +90 212 356 40 61 exportsales@systemairhsk.com.tr www.systemair.com.tr www.systemair.com IGH FX / IGH FX EC April 2015