DECLARATION OF PERFORMANCE 1 N. For structural use in all types of construction works according to EN

Similar documents
For structural use in all types of construction works according to EN

COMMISSION DELEGATED REGULATION (EU)

CE marking of noise barriers and foundations

DECLARATION OF PERFORMANCE. No EN. Annexes B 1 to B 4

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

in accordance with Annex 111 of Regulation (EU) No. 305/2011 ( Construction Products Regulation ) ULTRA PROFLEX SP+ES GREY

Declaration of Performance

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE. No EN

Declaration of Conformity Declaration of Performance Notes

DECLARATION OF PERFORMANCE

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

DECLARATION OF PERFORMANCE. No EN

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 6

DECLARATION OF PERFORMANCE. DoP: 0124 for fischer Ceiling Anchor FDZ (Metal anchors for use in concrete (light-duty type)) EN

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE. No EN

DECLARATION OF PERFORMANCE. DoP: 0135 for fischer injection system FIS EM Plus (Bonded anchor for use in concrete) EN

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 4

DECLARATION OF PERFORMANCE. No EN

1. Terms defined in the Construction Products Regulation (CPR)

Introduction. Declaration of performance (DoP) CE marking

DECLARATION OF PERFORMANCE

DECLARATION OF PERFORMANCE. No EN

F O C U S D O O R C L O S E R S

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Declaration of Performance

DECLARATION OF PERFORMANCE. No EN. Post-installed fastening in cracked or uncracked concrete, see appendix, especially Annexes B 1 to B 9

DECLARATION OF PERFORMANCE. No EN

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

Declaration of performance ( DoP ) :

Guideline Construction Products Regulation (EU) 305/20122

See product BS EN :2010

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

DECLARATION OF PERFORMANCE. DoP: 0094 for Injection System fischer FIS V (Bonded anchor for use in concrete) EN

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

CPR Guide: EU Rules Practical Impact

CPR Guide: EU Rules Practical Impact

Technical Bulletin CE marking: from 1st July 2013

The Danish Energy Agency will carry out inspections in June 2013

Guidance on Declaration of Performance and CE marking of windows and external pedestrian doorsets according to the CPR

DECLARATION OF PERFORMANCE

GNB-CPR Position Paper: Issuance of certificates under CPR

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

CPR, CE-marking of construction products 1

CERTIFICATE. Conformity of the Factory Production Control CPR TÜVRh

Your Key to achieving C.E Marking Compliance

Implementing the Construction Products Regulation (EU) 305/2011

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

The New EU-Regulation on Construction Products

Guidance Note No 19/1. CE Marking windows and doorsets

Declaration of Performance and CE marking of windows and external pedestrian doorsets according to the CPR

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

Co-ordination of the Group of Notified Bodies for the Construction Products /Regulation 305/2011/EU

EN :2012 EN :2012 ETAG 026 part 3:2011 DECLARATION OF PERFORMANCE. Sikasil -670 Fire

Domestic Garage Doors

COMMISSION DELEGATED REGULATION (EU) /... of

The Danish Energy Authority to carry out inspections in June and July 2012

European Technical Assessment. ETA-07/0211 of 19 May English translation prepared by DIBt - Original version in German language.

The future of the CPR, is CE marking changing? 26/10/2018

Record of Amendments. Version Date Amendment Section/page affected

Specification for Road Works Series Introduction

Construction Products Regulation (EU) No 305/2011

(recast) (Text with EEA relevance) out the conformity assessment procedure. Conformity 20 February 2014.

EUROPEAN UNION. Brussels, 13 February 2014 (OR. en) 2011/0357 (COD) PE-CONS 54/13 ENT 190 MI 550 CONSOM 128 COMPET 470 CODEC 1481

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!

Review of reports and data for Aero-Therm thermal reflective coating. Prepared for: Mr Craig Clement Director

Regulation (EU) No 305/2011 laying down harmonised conditions for the marketing of construction products (EU CPR)

A Notification under Article 12 of Regulation (EU) No 1025/2012 1

CE MARKING OF WOOD-BASED PANELS

COMMISSION DELEGATED DECISION (EU) / of XXX

European Technical Assessment. ETA-02/0020 of 11 December English translation prepared by DIBt - Original version in German language

PARKERSTEEL Vauxhall Road, Canterbury, Kent CT1 1HD

Lawnmowers, pedestrian controlled (combustion engine powered)

Stanley Black & Decker Deutschland GmbH Richard-Klinger-Straße Idstein DEUTSCHLAND. Manufacturing plant Manufacturing Plant 4 and Plant 9

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

European Technical ETA-07/0332 Assessment of 30 January 2015 General Part

European Technical Approval ETA-08/0035 This ETA replaces ETA-08/0035 with validity from till

Record of Amendments. Version Date Amendment Section/page affected

DECLARATION OF COMPLIANCE PERFORMANCE AND CE MARK

Firetect C. Fire protective products: Fire protective board

Council of the European Union Brussels, 21 March 2017 (OR. en) Mr Jeppe TRANHOLM-MIKKELSEN, Secretary-General of the Council of the European Union

European Technical Assessment. ETA-10/0255 of 22 August General Part. Technical Assessment Body issuing the European Technical Assessment:

The effects on the UK Fire Industry. Paul Pope Eng.Tech AIFireE

DIRECTIVE 2014/34/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

European Technical Assessment. ETA-14/0125 of 26 May General Part. Technical Assessment Body issuing the European Technical Assessment:

Mechanically operated locks and locking plates

The Machinery Directive 2006/42/EC

European Technical ETA-11/0080 Assessment of 9 February 2016 General Part

SD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions)

COMMISSION IMPLEMENTING REGULATION (EU) No /.. of [dd mm yyyy]

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

Construction Products Directive

COMMISSION DELEGATED REGULATION (EU) /... of

Transcription:

DECLARATION OF PERFORMANCE 1 N EN 1090-1 DoP ENG. 03 EN10210-2 1 Unique identification code of the product-type: Component(s) 2 according to EN 1090-2 following customer s specification and produced out of hot finished structural hollow sections of non-alloy and fine grain steels, made according to EN 10210-1+2 ; with types and grades: o S235JRH - 1.0039 o S275JOH 1.0149 o S275J2H 1.0138 o S355JOH 1.0547 o S355J2H 1.0576 o S355K2H 1.0512 o S275NH 1.0493 o S275NLH 1.0497 o S355NH 1.0539 o S355NLH 1.0549 o S420NH 1.8750 o S420NLH 1.08751 o S460NH 1.8953 o S460NLH 1.8956 Applied processes: activities of manufacturing (3.6), execution (3.7), preparation (3.12) according to EN 1090-2+A1:2013. Applicable processes: decoiling and cutting to length of sheets, sawing, shearing and nibbling, thermal cutting, laser cutting, drilling of holes, shot blasting, painting, batch galvanizing, electrolytic zinc coating, coating 2 Intended use/es: For structural use in all types of construction works according to EN 1090-1. 3 Manufacturer: SAEY nv/sa SAEY sarl, Industrielaan 4, B-8501 Heule 4 Authorised representative:: not of application 5 System of AVCP: System 2+, Declaration of the performance of the essential characteristics of the construction product by the manufacturer 1 As reproduced from COMMISSION DELEGATED REGULATION (EU) No 574/2014 of 21 February 2014 amending Annex III to Regulation (EU) No 305/2011 of the European Parliament and of the Council on the model to be used for drawing up a declaration of performance on construction products. The CPR* takes precedence over the (annexes ZA of the harmonised) standards that must still be reviewed. [* Including its article 61 The power to adopt delegated acts referred to in Article 60 shall be conferred on the Commission for a period of 5 years from 24 April 2011. ] 2 According to article 3.11 of EN 1090-2:2008+A1:2011 (E)

6 Harmonised standard, Notified body: EN 1090-1:2009+A1:2011, OCAB-OCBS CE1148 performed initial inspection of the manufacturing plant and of factory production control and performs continuous surveillance, assessment and evaluation of factory production control under system 2+ and issued the certificate of conformity of the factory production control 2014-07-11. 7 Declared performance(s) NBN EN 1090-1+A1 : 2012 Essential characteristics Performance Harmonised technical specification EN 1090-1 Tolerances on dimensions and shape Tolerances according to the class for fundamental tolerances in EN1090-2 and according to article 6.10 of EN10210-1 4.2 ; 5.3 Weldability According to article 6.7.1 and annex A and B of EN10210-1 4.3 ; 5.4 Fracture toughness, Impact resistance According to article 6.6.2-4 of EN10210-1 and table A.2-3 and B.2-3 4.3 ; 5.4 ; 4.8 ; 5.10 Load bearing capacity According to article 6.6.1 of EN10210-1 and table A.2-3 and B.2-3 4.5.1 ; 4.5.2 ; 5.6.2 Deformation in Service limit state According to article 6.6.1 of EN10210-1 and table A.2-3 and B.2-3 4.5.5 Fatigue strength NPD 4.5.1 ; 4.5.3 ; 5.6.2 Resistance to fire NPD 4.5.1 ; 4.5.4 ; 5.7 Reaction to fire Class A1 for products without coating 4.6 ; 5.8 Release of cadmium and its compounds NPD 4.7 ; 5.9 Emission of radioactivity NPD 4.7 ; 5.9 Durability According to article 6.7.2 of EN10210-1. Suitability for hot dip galvanising according to EN ISO 1461 and EN ISO 14713-2 4.9 ; 5.11 8 Appropriate Technical Documentation and/or Specific Technical Documentation: See included annexes (EN 10210-1 : Annex A (Table A.1, A.2, A.3) and B (Table B.1, B.2, B.3) and CE-marking of the delivered components. The performance of the product identified above is in conformity with the set of declared performance/s. This declaration of performance is issued, in accordance with Regulation (EU) No 305/2011, under the sole responsibility of the manufacturer identified above. Signed for and on behalf of the manufacturer by: Bernard Saey Managing Director Heule, August 13 th, 2018. INCLUDED ANNEXES : EN 10210-1 : Annex A (Table A.1, A.2, A.3) and B (Table B.1, B.2, B.3)