SPECTRAL INSTRUMENTATION

Similar documents
An FT-NIR Primer. NR800-A-006

Chemistry Instrumental Analysis Lecture 14. Chem 4631

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

Chemistry Instrumental Analysis Lecture 4. Chem 4631

scale analysis to micro scale imaging-ftir. State of the art and future perspectives.

Technical specifications of FT-IR Spectrometer

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

Propagation loss in optical fibers (01/29/2016)

Model S FT-IR SPECTROMETER

Pyroelectric Infrared Sensor PIR

Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

Measurement of Light. Photosensors

FPI Detectors Pyroelectric Detectors with Spectrometer Functionality

Specifications Wavelength Range: 190 nm to 800 nm continuous

Fundamentals of Far-infrared

Fibre Optic Sensors: basic principles and most common applications

Bunch Length Interferometer System

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

Exercise 1: IR Transmission and Reception

Passive Standoff FTIR Detectors as Transducers. Background From radiation to information

EXTENDING RAMAN INTO THE THz REGIME

Gas Temperature Measurements with High Temporal Resolution

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

Date: Wednesday, January 31, 2018 Time: 8:30 am 5:00 pm Location: Moscone West (Room 2018, Level 2)

INVENIO R. Innovation with Integrity. The new intuitive FTIR R&D Spectrometer FTIR

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Emission Monitoring System

Technical Information OUSAF44

THERMAL PROCESSING THEORY

INTERNATIONAL JOURNAL OF RESEARCH GRANTHAALAYAH A knowledge Repository

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

TENSOR II. Innovation with Integrity. FTIR Spectrometer Reliable. Convenient. Powerful. FTIR

Current Research Topics in Optical Sensors and Laser Diagnostics

Chapter 1. Introduction

Title: Laser Safety Effective Date: 9/91 Revision: 2/97 Number of Pages: 7

Heat Management Methodology

VS Glow Is the Newest and Most Technically Advanced Infrared Heater that Generates Instantaneous Heat

Bright, Chromatic and Distinct - Perception and Detection of LED-based Airfield Lighting

Questionnaire on activities in radiometry and photometry. Reply from: Korea Research Institute of Standards and Science (KRISS)

Technical Information OUSAF21

OMA-300 Process Analyzer

Measuring THz Radiation choose a Pyroelectric Detector or Golay Cell?

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

Temperature dependent Components within the Pyroelectric Detector

Variable Temperature Microprobe Systems

Technical Information OUSAF12

Variable Temperature Options for Optical Experiments

NYC STEM Summer Institute: Climate To Go! Infrared detection of carbon dioxide

Spectrum IR Series Mid-, Near- and Far-Infrared Spectroscopy THE WINNING PLATFORM

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

Publication American Institute of Physics. Reprinted with permission.

Technical Information OUSAF22

From THz to X-ray - Inventing the Future. Progress in NIR spectroscopy and its industrial applications

The Optical Scattering Calibration System at SNO+ IOP 2015

The design of the human body infrared thermometer

CALIFORNIA INSTITUTE OF TECHNOLOGY LASER SAFETY MANUAL. January, 1998

Exhaust Air Plenum Heated Supply Air. Direct Impingement Convection Dryer. Heated Drum. Typical Conduction Heating System.

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

APPLIED. OMA-406R Rackmount Process Analyzer

Advanced gas sensing applications above 3 µm enabled by new DFB laser diodes

Company facts. ! Photoacoustic Spectroscopy (PAS) and! Fourier Transform InfraRed (FTIR) principle

Design of a high accuracy non-dispersive Infrared gas sensor for continuous emission monitoring of carbon monoxide emitted from an industrial stack

EMITTER TECHNICAL DATA

Development of a variable output LED-365 irradiance standard

Compact Raman spectrometer system for low frequency spectroscopy

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Optical Sensor (2A) Optical Sensor Type Optical Sensor Characteristics. Young Won Lim 9/12/09

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

20 N. (12) Patent Application Publication (10) Pub. No.: US 2005/ A1. (19) United States SNNNNNNNNNNNNNSYNP 28-34

Technical Information OUSTF10

Distributed Temperature Sensing

Integrating Sphere Detectors. Wide Range of Stock Items. Individual Custom Configuration and Design. OEM Design and Production. Traceable Calibrations

Introduction to Fiber Optic Sensing

Laser Distance Sensor Type M Analog-Output

The FEL Facility Optical Diagnostics and FEL Characterization

SIMRAD GD10 IR GAS DETECTOR

to get there. together. Infrared Sources Swiss made

InstrumentationTools.com

Challenges in industrial point sensing- NDIR John Saffell

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

IRT2 Dual Laser IR Thermometer - User Guide

Spot on Fraunhofer IAF

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

-smartgas- A new low cost infrared gas sensor for domestic and automotive applications

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Construction of a Calibration System for Power Responsivity of Optical detectors Using Different Laser Sources

The George Washington University. Laser Safety Manual

Communications. Sensing. Instrumentation. Delivering tomorrow s optical and photonic solutions today. BREAKTHROUGH PHOTONIC PRODUCTS

Customization of Optoelectronic Detectors Part Two in a Six-Part Series

PVDF sensors Technical information

Laser Cutting Machine Safety Guide (For employers and employees)

Radiation and Laser Safety

Curing with Electric Infrared

Mid-Infrared Laser based Trace Gas Sensor Technologies: Recent Advances and Applications OUTLINE. Mar. 23, Houston, TX

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

Mechanism of audible sound generation during flash lamp operation. Tetsuya Kitagawa, Mitsuru Ikeuchi, Yukihiro Morimoto, Fumihiko Oda

E11 Tests of trace gas concentration multicomponent. monitoring system

Transcription:

SPECTRAL INSTRUMENTATION The typical setup of an IR experiment includes a light source, a sample, (a microscope), the spectral apparatus, a detector and a computer. IR experiment A light source emits polychromatic IR light, which is focused on a sample. The light is partially absorbed by the sample when it is passing through it. Molecules in the sample interact with the light, they take up energy and use this energy to vibrate, with the condition that the dipole moment changes. A detector registers how much light is transmitted through the sample. The result is a characteristic spectrum showing the transmittance (absorbance) of electromagnetic radiation as function of wavelength (wavenumber). Radiation Sources The most frequently used light source is the Globar, which is silicon carbide in form of rods or helixes. A globar can be directly ignited, and has a burning temperature of 1500 K, which needs to be water-cooled. The globar has the advantage of a relatively high emissivity to about 100 cm -1, so it can be used into the far IR region. Another source is the Nernst rod, which works at a temperature of 1900 K and is used for the MIR region.

It consists of zirconium oxide rods with additives of yttrium oxides or oxides of other REE. The Nernst rod is a non-conductor at room temperature, initial heating is required for ignition. It has following disadvantages: sensitive, deforms easily, oxide mix has negative temperature coefficient of the electrical resistance, i.e. electrical conductivity increases with temperature. Metallic helices, i.e., chromium nickel alloys or tungsten with operating temperatures of about 1300K, are usually air-cooled and used in NIR. For NIR you can also use tungsten-halogen lamps. For FIR, below 100 cm -1, you can use mercury high-pressure lamps. It's plasma emission surpasses the spectral radiation power of a black radiator of the same temperature. They must be started by a high-voltage pulse. Lasers can be used as radiation sources, too. Gas lasers scan rather narrow spectral regions (CO 2 laser 1100-900 cm -1, CO laser 2000-1800 cm -1, NO 2 laser 900-910 cm -1, He-Ne laser (632, 1.152 and 3.391 µm)). Semi-conductor diode lasers are larger tunable, and can cover almost the whole MIR region, e.g., PbSnSe-type lasers. A disadvantage is their low operation temperature of 15-90 K. Other examples, such as the gallium arsenide -, or gallium aluminium arsenide lasers work in the IR region, and can be operated at room temperature.

Microscope Infrared microscopes use reflecting optics such as Cassegrain objectives with 15fold or 36 fold magnification instead of glass or quartz. Using a microscope makes it possible to select a distinct measurement area on the sample and exclude contaminations from the measurement. Spectrometers There are various types of spectrometers, non-dispersive (no variable wavelength selection possible), dispersive (variable wavelength selection using gratings or series of filters) and Fourier Transform (FT) spectrometers (spectral splitting via interferometer allows wavelength-dependent radiaton modulation). The optical system in a spectrometer is used to transmit radiation to the detector. Lens systems of glass or quartz as used in UV and VIS range are useless in the IR range, because they absorb most of the radiation below 5000 cm -1. Thus, IR spectrometers are equipped with mirror optics. Dispersive spectrometers consist of a monochromator splitting radiation into its parts, which then separately exit to the detector by turning the grating or mirrors. With the Echelle grating earlier problems of low light intensity were overcome by using specially formed grooves (in metal or glass).

The main part of a FT spectrometer is the Michelson interferometer, in which the radiation is split by a semi-permeable beamsplitter into two partial beams that are reflected back to the beamsplitter via a fixed and a movable mirror. At the beamsplitter the two beams recombine and are brought to interfere. The motion of the movable mirror changes the optical pathlength, so both partial beams have a phase difference and the interference amplitude is changing. The detector registers an intensity signal as function of the change of the optical pathlength, which is then transformed into an interferogram. Beamsplitter Spectral range Quartz 15600-2700 cm -1 CaF 2 / Fe 2 O 3 12000-1200 cm -1 KBr/Ge 6500-450 cm -1 CsI/Ge 7000 220 cm -1

Advantages of FT spectrometers over dispersive ones: wavelengths are measured simultaneously shorter measurement time at same signal-to-noise ratio higher light throughput at same spectral resolution wavenumber stability is higher scattering can be neglected, because sample is place behind the interferometer Spectral Resolution Spectral resolution is defined by the distance between two neighboring absorption maxima having about the same height, which are separated by an absorption minimum, the transmittance of which is approximately 20 % higher than the band maxima. Spectral apparatus Resolution Dispersive spectrometer (grating monochromator) 0.2 cm -1 specially designed dispersive set ups

0.02 cm -1 Dispersive spectrometer (prism monochromator) 2 20 cm -1 FT spectrometer 0.001 cm -1 IR Detectors Detectors convert the optical signal into electrical signals. There's a variety of different types, such as thermal, pneumatic, pyroelectric or photoelectric detectors. Nowadays most detectors are photoelectric detectors because of their higher sensitivity. Incident light alters the electrical conductivity in an irradiated semiconductor material. The photosignal is measured as a change in voltage via the resistance or current. Common types InSb: photoconductive or photodiode, 10000 1500 cm -1, liquid-nitrogen- cooled MCT: photoconductive, spectral range 12500 400 cm -1, liquid-nitrogen- cooled DTGS: pyroelectric, MIR region, works at room temperature

Polarized measurements Polarized measurements can be very useful for the analysis of oriented minerals with IR spectroscopy. Polarized radiation is produced with a polarizer consisting of a fine grating with parallel metal wires. In oriented crystals certain dipole moment changes lie in a fixed direction during the molecular vibration and can be excited when the IR radiation is also polarized in this direction. The efficiency of a polarizer depends on its grid spacing and optical throughput. Common materials are ZnSe (MIR), KRS-5 (MIR), Ge (MIR, highest efficiency with 90% throughput), polyethylene (FIR), polyester (FIR), CaF 2 (NIR). Source: https://serc.carleton.edu/nagtworkshops/mineralogy/mineral_physics/raman_ir. html