INSTRUCTION FOR THE USER THC V E OIL BLU

Similar documents
USER MANUAL ACQUAHOME 32 B BLU

COnDEnSInG BOIlERS TAU UNIT OIL USER parameters manual

INSTALLATION, TECHNICAL ASSISTANCE CENTRE AND SYSTEM MANAGEMENT MANUAL THC V E OIL BLU

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

Operating instructions

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

user s instructions MH-water heater

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual

cod. Doc rev. 2 12/ ACI PLUS EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL

The guarantee on this appliance is valid for 12 months from the first day of installation.

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

CONDENSING BOILERS TAU UNIT OIL 35 G OIL 55 G INSTALLATION, MAINTENANCE AND SYSTEM MANAGEMENT MANUAL

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

/2010 US/CA

Operating Instructions Heating Controllers RVL479, RVL480, RVL481, RVL482

USER'S INFORMATION MANUAL

Operating instructions

RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Boiler controllers User manual. Building Technologies HVAC Products

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

USER GUIDE VOGUE MAX SYSTEM

Installation Manual STOR C. Solar combination storage cylinder. Installation Manual

User Manual for model

Operating instructions

Operating instructions

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

ir-range 8G /03.15 Changes reserved.

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

Operating instructions

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

Operating Instructions

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

USERS MANUAL FOR GAS BOILERS

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

USERS GUIDE 24, 30. For installation guide see reverse of book

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

WHE 2.24 / WHE 2.24 FF

Heating and D.h.w. Controller RVL482 Basic Documentation

G a

user s instructions MH-water heater

Operating Instructions

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

RVL481. Heating Controller. including d.h.w. heating

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

End User Manual ACO 35 MFFI COMBI

ecotec pro Operating instructions Operating instructions For the operator GB, IE Gas-fired wall-hung high-efficiency boiler

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

M116 / M450 USER AND MAINTENANCE MANUAL FOR MODULATING-CONTROL BOILER WITH GAS BURNER EQUIPPED FOR NATURAL GAS. Type : B23 ATLANTIC 2000

GENUS HE GENUS HE 24 GENUS HE 30 GENUS HE 38. User Manual. Condensing wall hung system boiler

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

RVS46.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros 2 Zone controller User Manual. Building Technologies HVAC Products

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

USERS GUIDE. LOGIC+ Combi 24, 30, 35

5 On/Off button 6 Function selector switch 7 Symbol - Eco function 8 Symbol - Standard heating function

Operating instructions

RVS43.. RVS63.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Albatros2 Boiler controller User Manual. Building Technologies HVAC Products

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

E-COMBI EVO E-SYSTEM EVO

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

prestige Control Application Supplement - TriMax

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

INSTALLATION, OPERATION, MAINTENANCE AND SYSTEM MANAGEMENT MANUAL THE/TG

ENGLISH. REMOTE CONTROL / ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL

prestige Control Application Supplement - Type 5 MCBA WARNING

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

USER'S INFORMATION MANUAL

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

TABLE OF CONTENTS. IMPORTANT Please read this manual carefully.

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

prestige Control Application Supplement - TriMax

Logic+ Combi

prestige Control Application Supplement - ACVMax

Operating instructions

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

RVS13... RVS53... AVS75... AVS37... QAA75... QAA78... QAA55... Albatros2 Boiler controllers User Manual. Building Technologies HVAC Products

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

Control Application. Supplement - ACVMax

Quickheat 30 weather compensated boiler control

ProCon Boiler Controller Commissioning Quick Reference Guide

User instructions DHP-AT

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

VIESMANN. Operating instructions DIGITAL TIME SWITCH. for the system user. Digital time switch for the Vitodens 100-W, type WB1B

Installation, operating and servicing instructions

Room Unit for Boiler Control QAA User manual. Building Technologies. With OpenTherm Interface

CONDENSING BOILERS TAU UNIT OIL 28 B FLEX INSTALLATION AND MAINTENANCE MANUAL

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Type summary Albatros 2

Baxi Maxflow Combi WM

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

- Data Brochure Steam Control 279

Operating Instructions for use by heating contractor. VITOTRONIC r 100 VITOTRONIC r 300-K IMPORTANT

cod rev. 4 08/ Kombisolar 2S EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Transcription:

INSTRUCTION FOR THE THC V E OIL BLU

CONTENTS General safety information 4 Precautions 4 Control panel 5 Mode selection 8 User levels 10 Start-up 12 Temporary shutdown 15 Preparing for extended periods of disuse 15 Cleaning 16 Maintenance 16 Useful information 17 The following symbols are used in this manual: b = Identifies actions that require caution and adequate preparation. a = Identifies actions that you MUST NOT do This manual, Code 20091450 Rev. 0 (05/15) is made up of 20 pages. 2 CONTENTS

Dear Customer, Thank you for choosing THC V E OIL BLU boiler. You have purchased a modern, quality product that is designed to give dependable and safe service and to provide comfort for many years to come. Arrange for your boiler to be serviced regularly by THERMITAL's Technical Assistance Service. Their personnel are specially trained to keep your boiler efficient and cheap to run. Technical Assistance Centres also stock any original spare parts that might be required. This instruction manual contains important instructions and precautions that must be observed to ensure the trouble-free installation and efficient functioning of your boiler. Please accept our renewed thanks for your purchase. Thermital 3

GENERAL SAFETY INFORMATION The operation of any appliance that uses electrical power demands that a number of fundamental safety precautions be respected. a Do not allow children or infirm persons to operate the boiler unsupervised. a Do not operate any electrical devices or equipment, including switches or domestic appliances, etc., if you can smell fuel or fumes. If you detect any suspicious smells: - Ventilate the room by opening all doors and windows. - Close the fuel shut-off cock. - Report the fault immediately to the THERMITAL Technical Assistance Service or a professionally qualified heating engineer. a Never clean the boiler without first disconnecting it from the mains electricity supply by turning the main power switch OFF. a Never pull, disconnect, or twist the electrical cables coming from the boiler even if it is disconnected from the mains electricity supply. a Do no obstruct or restrict the vents in the room where the appliance is installed. Adequate ventilation is essential for correct combustion. a Do not leave flammable substances or containers in the room where the boiler is installed. a Do not touch the boiler when barefoot or wet. a Do not switch the boiler off if outside temperature drops below ZERO (risk of freezing). PRECAUTIONS b This instruction manual and that for the installer and Technical Assistance Service are integral parts of the boiler. They must be kept safe and must ALWAYS accompany the boiler, even if it is sold to another owner or user or transferred to another installation. If you damage or lose this manual, order a replacement immediately from your local THERMITAL Technical Assistance Centre. b The boiler must be installed by a legally qualified heating engineer. On completion of the installation, the heating engineer must issue the owner with a declaration of conformity confirming that the installation has been completed to the highest standards in compliance with the instructions provided by THERMITAL in this instruction manual, and that it conforms to all applicable laws and standards. b If you notice any water leaking from the boiler, disconnect it immediately from the mains electricity supply, shut off the water supply, and notify your local THERMITAL Technical Assistance Centre or a qualified heating engineer immediately. b Periodically check that operating pressure in the water circuit is over 1 bar. If water pressure is consistently low, contact THERMITAL s Technical Assistance Service or a professionally qualified heating engineer. b If the boiler is not going to be used for an extended period of time, proceed as follows to prepare it for shut-down. - Turn the mains power switch OFF. - Close the fuel cock and heating circuit water cock. - Drain the central heating circuit if there is any risk of freezing. b The boiler must only be used for the purpose specified by THERMITAL and for which it is designed. The manufacturer declines all responsibility, contractual or other, for damage to property or injury to persons or animals caused by improper installation, adjustment, maintenance or use. 4

PRIMARY INTERFACE / CONTROLS control panel 1 2 3 4 5 6 7 18 9 8 bottom view 8-9 17 16 15 14 13 12 11 10 1 - Safety thermostat trip indicator. 2 - Electronic operator unit (controller). 3 - DHW production on/off button (only present if the optional remote storage cylinder is installed). A line appears under the "v" symbol on the display when DHW production is enabled. 4 - Display 5 - Central heating mode selection button. A line appears under the symbols: s Automatic o Continuous COMFORT l Continuous REDUCED F COOLING b Frost protection. The "t" symbol is displayed. 6 - Information button "i" 7 - Burner lockout indicator. 8 - Manual reset for flue gas thermostat. Unscrew the protective cover to access the reset button. 9 - Manual reset for safety thermostat. Unscrew the protective cover to access the reset button. 10 - Remote burner reset button. 11 - "p" button for chimney sweep/safety thermostat test functions 12 - "R" button for manual mode 13 - Value confirm (OK) button. 14 - Value change knob. 15 - ESCape button. 16 - PC BUS connector. 17 - Main switch. 18 - Fuse. 5

SECONDARY INFORMATION / DISPLAY A B 1 2 3 C G F 2 1 D E A - DHW mode: ON or OFF B - Central heating modes: s AUTOMATIC o Continuous COMFORT l Continuous REDUCED F COOLING b Frost protection. The "t" symbol is displayed. C - Small numeric display: time D - Message area E - Daily heating program indicator F - Large numeric display: current value G - Display symbols: f Burner running B Change battery (room unit only, not supplied) w Holiday mode active n Error. Press the i button to display the error message. Press ESC to return to the main screen. C Wait: process running h Maintenance - manual or chimney sweep mode Reference to heating circuit ECO Heating temporarily OFF - ECO mode active 6

MAIN SCREEN 3 A1 B1 5 C1 D1 H1 G1 Boiler temperature E1 F1 A1 - DHW production mode: ON or OFF. Press the DHW button to (3) to switch DHW on or off (as shown by the line under the symbol). B1 - Central heating modes: Press the central heating mode button (5) to activate the various modes as shown by the line under the corresponding symbol. C1 - Current time D1 - COMFORT heating mode E1 - Message area F1 - Daily heating program indicator G1 - Current boiler temperature (If parameter 22 = Permanently the most recent information selected in Information mode is displayed.) H1 - Burner running Notes on functioning The control panel on the THC V E OIL BLU boiler controls the following functions. - Frost protection: The pumps are switched on on the basis of outside temperature irrespective of demand for heat. If outside temperature drops below -4 C the pumps are switched on. If outside temperature is between -5 and 1.5 C, the pumps are switched on for 10 minutes at intervals of 6 hours. If outside temperature is above 1.5 C the pumps are switched off. - Chimney sweep: The burner is ignited to obtain the conditions necessary for combustion analysis. To obtain continuous burner functioning, maximum operating temperature is set at the boiler s maximum setpoint. All loads are switched off to start with, in order to bring the boiler to its 64 C setpoint as quickly as possible. When the boiler reaches 64 C, the heating circuits are opened one by one to dissipate the heat and allow the burner to continue functioning. - Limit thermostat (parameter 2310): This function shuts the burner down if boiler temperature exceeds the maximum permitted limit, which coincides with the boiler s maximum setpoint (parameter 2212 = 80 C). - DHW charging priority: if an optional remote storage cylinder is installed and domestic hot water is drawn off while the central heating circuit is also in use, this function directs boiler power mainly to the DHW circuit. - Boiler switching differential: This establishes a minimum run time for the burner, to stop it igniting and shutting down repeatedly. The burner shuts down only if boiler temperature exceeds a predetermined threshold (parameter 2240). - Solar collector protection: - Collector frost protection (param. 3840) - Collector overtemperature protection (param. 3850) - Pump protection against vapour in heat transfer fluid (param. 3860) 7

Mode selection Press the central heating mode button (5) to select the various modes. The active mode is shown by a line under the corresponding symbol. 5 Boiler temperature Automatic s In automatic mode, room temperature is controlled by the time program. Characteristics: - Central heating operates according to the time program. - The temperature setpoint is set to comfort "o" or reduced "l" - All protection functions are active. - Summer/winter switching is automatic (ECO functions) and 24h limit functions are active. Continuous operation o or l In continuous mode, room temperature is controlled on the basis of the comfort/reduced setting: o Central heating set to comfort setpoint l Central heating set to economy setpoint Characteristics: - Central heating is continuously on with no time program. - All protection functions are active. - Summer/winter switching is automatic (ECO functions) and 24h limit functions are inactive if comfort level is selected (see parameters 730 and 732). Protection b In protection mode the central heating is switched off, but the system remains protected against frost (provided the electrical supply remains switched on). Characteristics: - Central heating is switched off. - Temperature is set to the frost protection setpoint. - All protection functions are active. - Automatic summer / winter changeover and automatic 24-hour heating limit active (ECO functions) Domestic hot water (DHW) v 3 An optional remote storage cylinder must be installed before DHW production can be enabled. Press the DHW button (3) to activate DHW production, as shown by a line under the corresponding symbol. ON: DHW is generated according to the DHW time program (parameters 560 to 566). OFF: DHW production is switched off but the protection functions remain active. Boiler temperature b You can force DHW production (PUSH function) by pressing and holding the DHW button (3) for at least 3 seconds. 8

Information i Press the information button (6) to display: - Errors or maintenance codes (see the Errors/Maintenance codes section) - Special messages. Other screens: b Other screens depend on the system configuration and status. Some of the info lines shown below may not therefore appear. - Room temperature - Minimum room temperature - Maximum room temperature - Room 1 setpoint - Room 2 setpoint - Room 3 setpoint - Cascade flow temperature - Boiler temperature - Outside temperature - Minimum outside temperature - Maximum outside temperature - DHW 1 temperature - DHW 2 temperature - Buffer tank 1 temperature - Buffer tank 2 temperature - Buffer tank temperature setpoint - Flow 1 temperature - Flow 1 temperature setpoint - Flow 2 temperature - Flow 2 temperature setpoint - Flow 3 temperature - Flow 3 temperature setpoint - Collector 1 temperature - Wood fuelled boiler temperature - Solar flow temperature - Solar return temperature - 24 hours solar energy yield - Total solar energy yield - Pool temperature - Pool setpoint - Heating circuit 1 status - Heating circuit 2 status (not active) - Heating circuit 3 status - Cooling circuit state - DHW status - Boiler status - Solar heating status - Solid fuel boiler status - Buffer storage tank status - Pool state - Error message - Maintenance message - Floor curing function - Date and time - Telephone number of technical assistance centre Chimney sweep mode R When you select manual mode, the "h" symbol appears and relays are energised/de-energised not according to any heating program but according to a default manual setting that can be set by pressing the information button (6). Boiler temperature 12 11 6 9

User levels There are 4 different user levels: - End user - Commissioning - Heating engineer - OEM (Manufacturer). See the Complete list of parameters section for a list of the parameters displayed in each level. Proceed as follows to access the user level you require. - Go to the main screen. If necessary, press the "ESC" button one or more times to return to the main screen. Boiler temperature Press the "OK" button. Press and hold the information button "i" for 3 seconds. - End user level. Turn the knob to scroll through the menu until you reach the end user programming level. Press "OK". End user Commissioning To enter the OEM level, you need to enter the Password (12434). Press the "OK". button to confirm each digit. Press "ESC" to cancel an entry. b - Pressing the "ESC" button takes you just one step back: the value entered is not saved. - If no change is made for 8 minutes, the system returns to the main screen. - Programming lines are displayed or hidden according to the system configuration and the user level (User, Commissioning, etc.). b Parameter values on the Commissioning, Heating engineer and OEM levels must only be changed by the THERMITAL Technical Assistance Service. EXAMPLE: SETTING THE CURRENT TIME Time of day and date Operator unit - From the main screen press "OK". - The message area displays a number of setting pages. Turn the knob until you reach the Time and date line. Press "OK" to confirm. 10

- The message area shows the current hour. Press "OK". Time of day and date Hours/minutes - The display flashes the current hour. Turn the knob to go on or back to the correct value. Press "OK" to confirm. - The display flashes the current minutes. Turn the knob to go on or back to the correct value. Press "OK" to confirm. uti uti The new time setting is saved and the display stops flashing. At this stage you can continue programming or press the central heating mode button (5) to return to the main screen. 5 EXAMPLE OF THE MENU STRUCTURE Time of day and date Hours / minutes Hours 1...24 h Operator unit Month / day Minutes 0...60 min Time program heating circuit 1 Year Time program 3/HCP Start summertime Holidays heating circuit 1 End summertime Diagnostics heat generation Heating engineer level parameters 11

start-up Have THERMITAL s Technical Assistance Service start-up your boiler for the first time. Once this has been done, the boiler can be left to function automatically. Under certain circumstances, such as after long periods of disuse, the user may need to re-start it without involving the Technical Assistance Service. Before doing so, perform the following checks and operations: - Check that the fuel cock and heating system water cock are shut. - While the system is still cold, check that the pressure (1) in the heating circuit is over 1 bar but below the maximum limit specified for the boiler. If water pressure is low, contact THERMITAL s Technical Assistance Service. 1 - Switch the electricity supply ON at the system s main switch and at the control panel. Check that the display comes on. ON OFF - When the boiler is first powered on, it performs a number of self-tests. These may take a few minutes. When the tests are completed, the display reads out boiler temperature. Boiler temperature Perform the following operations on the boiler control panel. - Press the "OK" button. Select "Operator unit" and press "OK". Select "Language" and press "OK". Set the language you want. Time of day and date Operator unit SEE THE parameters MANUAL FOR INFORMATION ON CONFIGURATION. 12

Setting the room temperature setpoint Turn the knob (14) to set the desired room temperature comfort setpoint. 5 Proceed in a similar way to set the room temperature reduced setpoint. - Press the "OK" button (13). - Select Heating circuit 1. - Set the room temperature reduced setpoint. Comfort setpoint b After changing a setpoint, you need to wait about 2 hours for the new setting to have any effect on room temperature. b If no room unit is installed, changing the room temperature setpoint simply shifts the heating curve. - Press the central heating mode button (5) to select "Automatic" (b). 14 13 - If the central heating system incorporates a room unit, check that this is active and proceed as follows to use the knob to set the room temperature setpoint (~20 C). - Press the Presence button (o/l) to display the "o" symbol. Comfort setpoint - Press "ESC" to return to the main screen. - If the system is made up of a number of different heating circuits, a room temperature setpoint must be set for each of them. The second circuit (optional) may be either direct or mixed. - Press the "OK" button. - Select Heating circuit 1-2-3 and press OK. Set: - the room temperature comfort setpoint (parameters 710-1010-1310) - the room temperature reduced setpoint (parameters 712-1012-1312) - the heating curve slope (parameters 720-1020-1320). 13

HEATING CURVE SLOPE Flow temperature C 100 90 80 70 60 50 40 30 4 3,5 3 2,75 2,5 2,25 2 1,75 1,5 1,25 1 0,75 0,5 0,25 20 10 0-10 -20-30 C Outside temperature b Heating curve slope must only be set by the THERMITAL Technical Assistance Service. b If no room units are installed, the room temperature setpoint set on the control panel simply performs a parallel shift of the heating curves. - Proceed as follows to set the weekly heating program. - Press the "OK" button. - Select "Time prog heating circuit 1" and press "OK". Only for "28/120 B" models with a remote storage cylinder (optional) - Press the "v" button to turn on DHW production. A line appears under the DHW symbol. - Press the "OK" button. - Select "Domestic hot water" and press "OK". - Set: parameter 1610 "nominal setpoint" Boiler temperature - To set the weekly DHW timer program, select "Time program 4/DHW" and press "OK". If any boiler ignition or operating errors are detected, the "n" symbol appears on the display. Press the "Info" (i) button to display the type of error. See also "Error/ Maintenance codes". Error 30: CH flow 1 sensor 14

Temporary shutdown If you are going to be away for a short period of time like a weekend or a short holiday, etc. proceed as follows. 5 - Press the central heating mode button (5) to select "Protection" mode (b). Power to the boiler remains switched on, and the display remains active. The fuel feed also remains open so that the frost protection function can protect the boiler against freezing. Boiler frost protection: if boiler temperature falls below 5 C, the burner starts up at full power until boiler temperature reaches 40 C. Plant frost protection: This function is only active if an outside temperature sensor is connected. If outside temperature drops below -4 C the pumps are switched on. If outside temperature is between -5 and 1.5 C, the pumps are switched on for 10 minutes at intervals of 6 hours. If outside temperature is above 1.5 C the pumps are switched off. Boiler temperature Preparing for extended periods of disuse If the boiler is not going to be used for an extended period of time, proceed as follows to prepare it for shut-down. - Turn the control panel power switch OFF and make sure that the display goes out. - Turn the mains power switch OFF. ON OFF - Close the fuel shut off cock and the central heating and DHW circuit shut off cocks. b Under these conditions the system is not protected against frost. Drain the central heating circuit and domestic hot water circuit if there is any risk of freezing. 15

xxxxxxxx CLEANING b Remove the protective film (F) from the front panel and the control panel before you start cleaning the boiler s casing panels. Use a cloth damped in soapy water to clean the boiler s external panelling. To remove stubborn marks, use a cloth damped in a 50% mix of water and denatured alcohol or a suitable cleaning product. Wipe the boiler dry after cleaning it. F b The combustion chamber and flues must be cleaned periodically by THERMITAL s Technical Assistance Service or by a qualified heating engineer. a Do not use abrasive products, petrol or triethylene. a Never clean or service the boiler without first disconnecting it from the mains electricity supply by turning the main power switch OFF. MAINTENANCE Please remember that THE PERSON RESPONSIBLE FOR SYSTEM MANAGEMENT MUST ENSURE THAT PROFESSIONALLY QUALIFIED PERSONNEL UNDERTAKE PERIODIC MAINTENANCE AND COMBUSTION EFFICIENCY MEASUREMENTS. THERMITAL s Technical Assistance Service is qualified to satisfy these legal requirements and can also provide useful information on MAINTENANCE PROGRAMMES designed to guarantee: - greater safety - compliance with applicable legislation - freedom from the risk of fines in the event of spot checks. 16

USEFUL xxxxxxxx INFORMATION Seller:... Mr.... Address... Tel.... Installer:... Mr.... Address... Tel.... Technical Assistance Service:... Mr.... Address... Tel.... Date Work done Fuel oil supplier:... Mr.... Address... Tel.... Date Quantity supplied Date Quantity supplied Date Quantity supplied Date Quantity supplied 17

18

19

Cod. 20091450 Via Mussa, 20 Z.I. - 35017 Piombino Dese (PD) - Italia Tel. 049.9323911 - Fax 049.9323972 - www.thermital.it - email: info@thermital.it As part of the company s ongoing commitment to perfecting its range of products, the appearance, dimensions, technical data, equipment and accessories may be subject to variation.