GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

Similar documents
SENTRY MK2 SOUND LEVEL CONTROL USERS MANUAL

Alarm Tone Generator Model AG17

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

Door Release Power Supply

Installation, Operating and Maintenance Manual

Call stations and extensions

Unity DAU Voice Alarm System

Instructions for the fan motor control system with integrated wiring terminals SILVER C

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

SA300 Amplifier OWNERS MANUAL

CFDAU30 Voice Alarm System

SOHO X. 4" Two-way passive system

HLS-2C Active Hearing Loop Panel

ENGLISH. Technical Specifications. Version 1.1 February 2003 EUROPOWER PMX2000

SATURN 12 SYSTEM. Order Code: SPEA41 ENGLISH

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

Intelligent Security & Fire Ltd

CVS 4 TEMPLATE CUTOUT SIZE: 180mm CVS 6 TEMPLATE CUTOUT SIZE: 250mm

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

GX-A604/GX-A602/GX-A3001

Instruction Manual WARNINGS

SP40S-D. Kingfisher Company, inc. Features: Description:

Instructions for the fan motor control system, SILVER C

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

For the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock

Microphones VIGIL VIGIL. Unitouch. combined data sheets LEADING THE WAY TO SAFETY

CMS CMS. Template cutout size: 187mm CEILING MONITOR SYSTEMS INSTALLATION MANUAL

Entero ESC emergency system controller

ENGLISH. Technical Specifications. Version 1.6 April 2007 EUROPOWER PMH2000

380 SERIES REMOTE SIREN ETSA380R

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

VPS3 Installation Manual

AE300. Integrated Voice Alarm System

Power Supply Display Module PSDM. Installation and Operation Manual

Emergency Assist Alarm Kit Single Zone

Alarm Panel Operating Instructions

Vocia VACIE. Reference Guide

Public Safety DAS Annunciator Panel

DESCRIPTION INSTALLATION

VACIE REFERENCE GUIDE REVISION 1.2.6

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

C106 Coded Access Keypad

EVG Extractors. Manual for Installation, Use and Maintenance

Bosch Plena Public Address and Voice Alarm System The fast route to safety

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

The front panel of the APCL-6002 contains both connections for RCA and speaker level inputs, along with the audio controls as shown below.

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Elemec3. Networked Public Address and General Alarm System (PA/GA)

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

PUBLIC ADDRESS SYSTEM

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

Installation and user manual for the BiWire / Conventional Repeater Panel

by Honeywell VOICE ALARM SOLUTIONS BROCHURE

PAC1500Xi PORTABLE APPLIANCE CHECKER

C-Bus Four Channel Analogue Output Unit Installation Instructions

MONITOR REFERENCE SERIES

LC2200 Level Controller Installation and Maintenance Instructions

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

OPERATING INSTRUCTIONS VOICE EVACUATION SYSTEM FS-7000 SERIES

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

ECC-50/100C. Emergency Command Center

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Installation and Operation Manual

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

Autonomous control unit

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

Instruction Manual Model L2 RF Switch

ECC-50/100(E) Emergency Command Center

SONARRAY. Raising the Bar on Outdoor Entertainment

Operating Instructions SUPERSTAR E-6000 / F2 for 1 1/2, 2 and VAC

OPERATION & MAINTENANCE MANUAL GUARDIAN SPACE PRESSURE MONITOR WITH REMOTE AUXILLARY ALARM

Entero Voice Alarm system.

MS SERIES MS 401 MS 601 MS 801 MS 401W MS 601W MS 801W. All-Weather Loudspeaker System. User Manual

ADE Gen4. Speech Dialler Engineering Information. Description. Features

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

CMS CMS C E I L I N G M O N I T O R SYSTE M S I N STA L L ATIO N M A N U A L. CMS801 TEMPLATE HOLE CUTOUT SIZE: 295mm (11.61 )

July 14, 1999 DF C-100.

AUDIO- AND ALARMMANAGEMENT

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

IMPORTANT SAFETY INSTRUCTIONS

SIL725 Safety Annunciator

TABLE OF CONTENTS. Please record the following information for your records: Serial Number: Date of Purchase: Dealer Name: Dealer Address:

Mimic display driver, LED ribbon cable

P Subwoofer System OWNERS MANUAL

DOCUMENTATION HANDBOOK MPA 1600 PUBLIC ADDRESS AND GENERAL ALARM SYSTEM.

Figure 1. Figure 2. See notes 1 and 2 below.

ACCURATE ELECTRONICS INC

Input module, input/output modules

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

GAI-Tronics Systems NEW! Elemec3 Digitally Controlled PA and General Alarm system PA/GA

Case Study: Victoria Palace Theatre

Dyna-Form Air. Alternating Pressure Relief Overlay System

L-BAND SATELLITE LEVEL MONITOR INSTALLATION MANUAL

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

Transcription:

GUARDIAN CX10 PRIORITY/EVACUATION INTERFACE USERS MANUAL

General information The CX10 provides a priority input into an audio system of up to 10 channels in a 19 1RU package. The CX10 may be used with any sound system where a priority override facility is required e.g. Entertainment venue, shopping centres, malls, cruise ships or any public area where fire, security or other important announcements are required. The CX10 features unity gain, balanced line level inputs, and outputs. The signal chains use low noise, low distortion pro audio circuits so as to be almost transparent in use. A balanced line level priority input is incorporated (microphone level priority input is available to order). The trigger input is via a closing contact which must be fully isolated. Operation The CX10 has been designed to be connected between the mixer/zoner (or pre amp) of an audio system and the power amplifiers. The priority signal (e.g. evacuation message) is a line level input and is connected to the priority input socket and the control input is connected to the fire alarm or whatever triggering method is required. In normal mode programme signals pass through the 10 audio channels of the CX10 with no change in level. When the unit is triggered the incoming programme level is attenuated and the priority signal is mixed into the ten outputs. When the unit is reset the priority signal is removed and the programme will fade back to the original volume. The attenuation level is fully adjustable, as is the priority signal level (The priority signal level is individually adjustable to the various outputs). A local test button is provided for setting up the system. Remote monitoring of units is possible by using the switch contacts available from the local test button, and the unit-powered relay (6 way connector). (Both provide single pole change over-contacts). If more than 10 channels are required multiple units may be fitted. The trigger input may be paralleled to several units so long as the polarity is maintained. E.g. pin 1 to pin 1 - pin 2 to pin 2. In a normal situation the connections to the CX10 can be considered as a straight-through link which will not affect the normal operation of the system. Only when the CX10 is triggered will there be any effect on the system. Set up On the back panel connect the line level priority source to the priority input and connect the trigger (normally a fire alarm) to the priority control connector (must be isolated contacts that close to trigger). Connect the mixer/zoner outputs to the connectors marked INPUT. The adjacent connector to each input is the output for that channel (marked OUT ). Connect the output to whatever was previously connected to the mixer/zoner (usually this will be equalisation, crossover or amplifiers). To test the unit use a small screwdriver to press the LOCAL TEST switch that is recessed behind the front panel, the PRIORITY LED on the front panel should illuminate. Press the LOCAL TEST switch again and after a few seconds the PRIORITY LED will go out (the LOCAL TEST switch also has an LED which is illuminated and visable through the recessed hole when the LOCAL TEST switch is on). A set of isolated contacts on the LOCAL TEST switch are available at the monitor ( MON ) connector pins 4,5&6 allowing a remote monitoring circuit to be connected (eg NO contacts can be used to close a circuit that lights a LED). There is also a set of isolated contacts at the monitor ( MON ) connector pins 1,2&3 allowing a remote monitoring circuit to be connected that will monitor the power status of the unit (eg NO contacts can be used to close a circuit that lights a LED or NC contacts can be used in which case the LED will go out). Through the front panel using a small flat blade screwdriver adjust the potentiometers marked 1 10 fully clockwise. Page 1

Play audio through a channel at the required level and trigger the priority using the LOCAL TEST switch. Through the back panel using a small flat blade screwdriver adjust the priority programme attenuation potentiometer marked ATTEN (generally music should be quiet but audible). Play audio through the priority input and through the back panel using a small flat blade screwdriver adjust the priority level potentiometer marked LEVEL for the maximum required system level, individual channel levels can then be adjusted below this level if required. Play audio through channels 1 10 and through the front panel using a small flat blade screwdriver adjust the potentiometers marked 1 10 fully for the required priority level on any channels where it is required to be lower than the system level. Mains Voltage The CX10 has been designed to operate on 220-240Vac, a 110-120Vac version is available on request from Formula Sound. Fuses Mains fuse sizes are 250mA anti surge for 220-240V operation and 500mA anti surge for 110-120V operation. It is important for safety reasons that the correct fuse sizes are always used. Internal There is a ground/earth lift located by the mains transformer towards the back and side of the unit. Removing this may be necessary in some installations. A skilled audio system specialist should determine if this is necessary, otherwise this should be left in the factory supplied or normal position. N.B. Internal settings should be undertaken by skilled personnel only. DISCONNECT THE UNIT FROM THE MAINS SUPPLY Remove the top case cover by removing 6 screws located at the sides of the unit and 2 screws located on the top of the unit. (Re-assemble in the reverse order) DAMAGE MAY RESULT IF THE UNIT IS CONNECTED TO THE WRONG SUPPLY VOLTAGE THIS UNIT MUST BE EARTHED Formula Sound Ltd Unit 23 Stadium Business Centre North End Road; Wembley Middlesex; England, HA9 0AT Tel +44 (0)208 900 0947 Fax +44(0)208 903 8657 Email info@formula-sound.co.uk www.formula-sound.co.uk Page 2

GUARDIAN CX10 MK TECHNICAL SPECIFICATION Gain Frequency Response Normal operation, unity gain +0dB -1dB 20Hz - 20KHz + 0.5dB -1dB Distortion THD @ 1KHz O/P +20dBU <.015% (Typically.007%) Noise < -90dBU EIN Inputs Balanced Unbalanced Connector type XLR Input impedance > 30K Ohms >15K Ohms Max input level +22dBU Outputs Electronically balanced; source impedance <100R Connector type XLR Max O/P level +22dBU into 600R load Controls 1 System priority input level into all channels 2 Attenuation of channels programme in priority mode 3 Attenuation of priority level in each individual channel 4 Manual test switch All controls are operated through holes in the front or rear panels. Priority input Balanced, input impedance >20K. Unbalanced, input impedance <10K Max I/P level +22dBU Control input Isolated switch contacts that close to operate Visual indicators Power - 2 x Green LED s Priority Red LED. Connectors 3.5mm pitch horizontal connectors, screw terminal mating halves provided Dimensions 19" rack mounting. 1RU, Width 482mm (19"), Depth 206mm (8.1"), Height 44mm (1.75") Finish:- Power Front - and Rear panels- Black anodised aluminium with silver notation which will not rub off in use. Case - black plastic coated steel. IEC Connector 220-240V AC. Mains Fuse 250mA Anti Surge (slow blow) To order: 110 120V AC. Mains fuse 500mA Anti Surge (slow blow)

FORMULA SOUND LIMITED UNIT 23; STADIUM BUSINESS CENTRE; NORTH END ROAD; WEMBLEY; MIDDLESEX; HA9 0AT TELEPHONE +44 (0)208-900-0947 FAX +44 (0)208-903-8657 www.formula-sound.co.uk email info@formula-sound.co.uk E.U. CERTIFICATE OF CONFORMITY We declare that the products listed conform to the following directives and standards 89/336/EEC amended by 92/31/EEC and 93/68/EEC BS EN 50082-1 BS EN 50081-1 PRODUCT TYPE GUARDIAN CX10 The CE mark was first applied in 1995 Signed B. J. Penaligon General Manager Attention The attention of the specifier, purchaser, installer, or user is drawn to the fact that good wiring practice must be observed when connecting the above equipment. Good quality connectors and screened cables must be used for all audio connections. Twin screened cables should be used for all balanced lines. THIS EQUIPMENT MUST BE EARTHED CONSULT THE USERS MANUAL FOR TECHNICAL DETAILS