ProRadiant Controls, Valves and Actuators

Similar documents
6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

Product Instructions. Basic Digital Snow Melt Control II. Applications. Features. Specifications

- Essay Control Functions and Benefits

Hydronic & HVAC Control Systems

Better Design, Better Control, Better Systems.

Control Panel Checklist

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Hydronic Mechanical Panels

Heat Link. Technical Guide

Climate Cŏntrol Multifunction Hydronic Control Installation and Operation Manual. Uponor Radiant Heating and Cooling Systems

- Data Brochure Universal Reset Module 422

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

ProRadiant Manifolds, Stations and Fittings

propanel Series Installation Manual

ProRadiant Basic Heating Control Installation Manual 2013

- Data Brochure Universal Reset Module 423

SMC. Snowmelt Control. Installers and Users Installation and Operation Manuals

- Data Brochure Universal Reset Control 364

2.A MANIFOLD SHUNTS MINI SHUNTS

T6984F,G Electronic Floating Control Thermostats

Instruction Sheet X Pump Block (XPB)

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

SAMPLE. added benefit of reduced operating costs during low demand periods, such as spring and fall.

Heat Link MECHANICAL ROOM IN A BOX. SSP Series. SS Manifold Pump Panel Installation, Operation, and Maintenance Manual. L6SSPxx000x-BMS SSPLR106T

Electro-HELPS XV ELECTRO-BOILER SPECIFICATIONS. A complete product line to fi t all your application needs. Made in USA

COLD WATER START A P P L I C AT I O N S

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

Product Number L4006A1017 L4006A1132 L4006A1967 L4006A2007 L4006B1007 L4006B1155 L4006B1163 3/4 (19) L4006H1004

- Data Brochure Mixing Control 360

Dual Mixing Application

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

Radiant Pipe Description

Thermostatic Radiator Valves (Caleffi)

T6984 A,D,E Electronic Floating Control Thermostats

Installation and User Manual. Snow Melt SM120, 200, 400 With Heat Exchanger

ProRadiant Combiflex. Viega's Hydronic Solution Installation Manual 2013

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

water to water heat pumps

Advanced Snow Melt Control Installation Manual

RA 2000 Series RA 15/6T & TB Conversion Valve

Tankless On Demand Electric Water Heater

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

Taco 00 Series Cartridge Circulators

Melt Demand. Idle Demand WWSD. Minimum Maximum Water Melting. Do not apply power. 27 Zn 2. Melt/Idle. Slab. Demand. Input Universal Sensor Included

WWSD. Power. DHW Demand. Maximum. Supply. Minimum Boiler DHW. Zone 1 / Cooling. Pump / Vlv. System Pump. UnOccupied. of full output NRTL/C LR 58223

Best Practices for Condensing Boilers

Outdoor Reset Control Theory FULL versus PARTIAL reset

Medium Mass Boilers. Maxim Power VT

Circulators high efficiency ECM Circulators

RA15/6T & TB Conversion Valve

Heat Transfer Packages

know exactly what you are getting before you order it. You can order with confidence knowing th each panel is completely tested before it ships.

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

T7984 A,B,C Electronic Modulating Control Thermostats

The electrical wattage needed by the circulator is:

heat interface units A BOILER WITHOUT A FLAME

Installation & Operation Manual

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

Powers Controls ET 134 Low Temperature Detection Thermostat

Radiant Mixing Block

Boiler Start-Up Cycle

TABLE OF CONTENTS BRADFORD WHITE BOILERS

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System)

Project Name: Location: Engineer: Contractor: I. GENERAL

PureFlow. PureFlow. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 61 Annex G Standards.

BHSAPPMAN 08/00 USA. Applications Manual. Ecomatic / Logamatic Controls. Save These Instructions!

prestige Control Application Supplement - TriMax

TWINTEMP JR. HYDRONIC SYSTEM 2/2013

Instruction Sheet. Variable Speed - Solar (00-VT) 00 and Load Match Cartridge Circulators

B-40/B-41 Modulating Temperature Controller

Instruction Sheet. Variable Speed - Outdoor Reset (00-VR) 00 Cartridge Circulator

C1N & C2N SERIES Fluid heating for light industrial applications

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

Applications and Piping Strategies for Condensing Boilers - Introduction

Wood Boiler Plumbing Schematics

DIVISION FINNED WATER-TUBE BOILERS

- Data Brochure Mixing Control 361

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

Installation & Operation Manual

Single and Multi-Function Aquastat Controllers

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

FINNED WATER-TUBE POOL HEATERS

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

Radiator Valve Program

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Gate Operator. Modfications

A. ASHRAE Handbook HVAC Applications, Snow Melting and Freeze Protection

Using Embedded Tube Radiant Cooling Systems to Maximize LEED Points

Water Heaters. Solar Applications

prestige Control Application Supplement - TriMax

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

Boiler Start-Up Cycle SYSTEM RETURN

2009 IECC Commercial Mechanical Requirements

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

Outdoor Reset IQ Option Card, p/n

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER HIGH EFFICIENCY CONDENSING BOILER

Smart temperature control solutions

ADDITIONAL INFORMATION

Transcription:

214 Controls, Valves and Actuators

Stock Controls, Valves and Actuators BASIC HEATING CONTROL Features: Modulating mixing valve control Supply temperature high limit Seasonal pump activation Boiler activation Mixing valve and pump exercising This basic electronic outdoor reset control modulates system water temperature as outdoor temperature fluctuates. BASIC HEATING CONTROL model 2871.0US OPTIONAL INDOOR SENSOR model 2871.2US 1015 1 3.399 10 0.10 MULTIPLE OUTDOOR SENSOR This sensor module is an option which allows up to four Basic or Advanced Heating Controls to share one outdoor sensor enclosure. The Multiple Outdoor Sensor module includes three 10 kω thermistors which provide an accurate measurement of outdoor temperature. The module is attached inside the outdoor sensor enclosure included with the control, and allows four separate sensors to be combined into a single enclosure mounted on the exterior of the building. model 2871.3US 1020 1 0.48 Zone Control The Viega Zone Control is a wiring and switching center for individual and/or multiroom control. The Zone Control simplifies wiring between Thermostats and Powerheads. LED lights on housing indicate individual zone heat demand. Available as a 4 or zone, both with priority. Zone Control includes optional circulator activation function and built in transformer. model 2874.7US 1800 1802 4 Zone Zone 5.099.198 Digital Thermostat The Digital Thermostat is ideal for individual room temperature control. A user friendly three button design allows for easy change of settings. Thermostat can sense either room temperature, floor temperature or both. Adjustable temperature setback function allows for energy savings. Thermostat can control up to four Powerheads directly or can be connected to a zone/circulator control box. With optional floor sensor, thermostat provides floor high or low limit function for floor protection or floor warming. DIGITAL THERMOSTAT model 2874.5US OPTIONAL FLOOR SENSOR model 2874.US 18050 3 1 0.22 18050 1 0.11 215

Stock DIGITAL SETPOINT CONTROL II The Viega Basic Digital Setpoint Control II is a general purpose temperature control with a wide range of applications in the HVAC industry. This control provides two isolated SPDT relay contacts. The two relays are controlled by a watertight sensor, included with the Basic Digital Setpoint Control. This control is commonly used as basic heating and/ or cooling system control for commercial and residential slab applications. model 2875.4US 17029.81 BASIC DIGITAL SNOW MELT CONTROL II The Viega Basic Digital Snow Melt Control II provides automatic snow melt system activation with slab high limit. This control senses low air temperature and precipitation to activate the snow-ice melting system. A slab sensor prevents overheating of the slab. Equipped with a timer switch for manual activation. model 2875.3US 17023 1 3.299 SET POINT CONTROL SENSOR This Sensor can be used to utilize second setpoint relay option on the Digital Setpoint Control II. model 2875.5US 1703 0.002 VA TRANSFORMER These transformers can power thermostats, powerheads, actuators, relays, or any other 24 VAC components. Choose size based upon load. model 2872.2US 18008 18020 40 1 75 1 1.999 2.799 21

Stock ADVANCED SNOW MELT CONTROL Features: Minimum boiler return temperature for boiler protection Max. system ΔT to prevent thermal slab shock Powered system pump output Boiler activation output Easy sensor installation with included sensor housing The Advanced Snow Melt Control provides accurate and sensitive snow detection and snow melting system activation. It operates either a floating mixing actuator or a variable speed injection pump. One durable sensor monitors slab moisture and slab temperature for the most efficient operation. Microprocessor control provides user-friendly setting and LCD readout of sensor readings. model 2872.4US 17015 1.297 POWERHEAD FOR STAINLESS MANIFOLD Fits Viega's stainless manifold return valves to provide individual zone control. 24 VAC, normally closed. Connects to standard Zone Control or can be wired directly with thermostats. model 2877.7 150 0.30 PUMP AND BOILER RELAY Pump and Boiler Relay provides simple activation of pump and boiler from a dry signal, such as a Zone Control or the Advanced Snowmelt Control or a powered signal from a thermostat. 120 VAC supply. Includes internal 24 VAC transformer. Provides high-voltage contacts for pump activation and separate dry contacts for boiler T-T or low-voltage applications. model 287.0US 18033 1 2.499 THREE POSITION ACTUATOR FOR STATIONS This three position (floating) actuator controls the Stations or a Diverting Valve from a 24 VAC floating signal. Compatible with Basic and Advanced Heating Controls. model 2872.7US 18003 1 0.0 PROPORTIONAL ACTUATOR FOR MIXING STATION (0-10V) This modulating actuator controls the diverting valve of a Mixing Station. Utilizing a 0-10 V DC signal the actuator allows the compatibility of a Mixing Station to a direct digital control system (DDC). Adapter for diverting valve included. model 2874.4US 18025 1 0.243 217

Stock MIXING VALVE ACTUATOR The Actuator is designed to provide electronic temperature control for Viega's Mixing Valves in heating, cooling and snow-ice melting applications. The actuator is designed to fit and modulate all of Viega's Mixing Valves 3/4" - 2". Operated by a 24V signal from the Viega Basic Heating Control, Advanced Heating Control and Advanced Snow Melt Control. model 2870.7US 20042 3/4-2 1 FOUR WAY MIXING VALVES Four-way mixing valves regulate supply fluid temperature to the system and the return fluid temperature to the source. Four-way valves can be used in heating, cooling, snow and ice melting applications. These valves can be controlled manually or automatically. To properly protect the heat source from flue gas condensation the four way mixing valve must use actuator (stock code 20042). F NPT model 287.1US 20070 20071 20072 20073 20074 /4 1 /2 1 2 1 COPPER (FEMALE) model 287.2US 20075 2007 20078 /4 1 THREE WAY MIXING VALVES Three way mixing valves regulate fluid temperature to the system from the source. These valves are ideal for mixing or diverting fluid to control temperature in heating, cooling, and snow-ice melting system applications. The valves can be controlled both maually or automatically with the use of an actuator (stock code 20042). model 287.3US 20080 20081 20082 20083 20084 /4 1 /2 1 2 1 Temp. Range NON-ELECTRIC CONTROLS This modulating valve control will maintain a fixed system supply water temperature regardless of boiler temperature or flow rate. Fits Stations or Diverting Valves. model 2872.8US 1102 1115 1104 1105 8 F-122 F 1 8 F-140 F 1 104 F-158 F 1 122 F-17 F 1 3.887 NON-ELECTRIC OUTDOOR RESET CONTROL This modulating valve control fits both Stations and Diverting Valves. Control modulates system water temperature based upon outdoor temperature and the selected ratio setting. Capillary length 32 feet from valve to outdoor sensor (-1/2 feet from supply sensor to actuator; -1/2 feet from actuator to ratio adjuster; 2 feet from ratio adjuster to outdoor sensor). model 2873.0US 110 1.30 218

Stock Copper (Female) DIVERTING VALVE Three-way diverting valves for temperature control in many heating and snowmelting applications. Includes solder tailpieces. model 2873.1US 20001 20002 20003 20041 /4 1 /2 1 2.199 2.999.098.098 F NPT SPRING CHECK VALVE Spring check valves ensure proper flow direction by preventing gravity circulation or backflow. These compact valves can be installed in any direction (vertically or horizontally). Constructed of all non-ferrous components for corrosion resistance. model 2873.4US 20201 20202 20203 20204 20205 1/2 1 /4 1 /2 1 0.30 0.40 0.0 1.10 CIRCULATOR PUMPS Viega offers two 3-speed, wet rotor, direct drive, in-line circulator pumps designed for residential and light commercial applications. These circulators are quiet and maintenance free, making them ideal to use in primary and/ or secondary loop system piping. LOW HEAD model 2801.1US HIGH HEAD model 2801.9US 1212 1 7.248 12127 0.247 CIRCULATOR PUMP FLANGE model 2874.3US 1207 1209 1211 1212 /4 1 /2 1 2.023 2.023 1.915 1.915 SENSOR WELL SET Viega's Sensor Well Set is designed to house the universal or supply temperature sensor for either the Basic Heating Control or Advanced Heating Control. Sensor Well is 1/2" CTS and fits into solder cup or ProPress fitting. model 2801.4US 12128 1/2.00 219

Stock in x in, plates HEAT EXCHANGER Brazed plate heat exchangers for radiant heating and snow melting applications. model 2859US 2200 22007 22008 5 x 12, 5 x 12, 3 1 5 x 12, 70 1 8.997 17.495 29.992 220