LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

Similar documents
BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

Clean Bench Animal Transfer Stations

5.0 Installation Instructions

LABORATORY CABINETS 103

A. Standards: Except where modified or exceeded by the requirements of this Specification, conform to the following standards:

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

B. Design meeting requirements of the particular class and type of cabinet as follows:

Safe Operating Procedure (Revised 2/10)

Biological Safety Cabinets or Fume Hoods Which one to use?

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

European Standard EN12469:2000 Tested. Class II Design: Personnel, Product / Sample, Environment Protection

Animal Containment Workstation The Portable Safety Solution for Animal Research Laboratories

LAMINAR FLOW FOR ALL YOUR NEEDS

DOWNDRAFT BENCH SERIES

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Forma 1400 Series Class II, Type A2 Biological Safety Cabinet. Superior Ergonomics, Uncompromising Safety

Innovation in air purification unmatched air quality

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

AIR SHOWERS CAP701 SERIES


General Purpose Laminar Flow Cabinets, Horizontal and Vertical

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

Standard Operating Procedure M.I.C.E.

6/19/2015 BIOLOGICAL SAFETY CABINET. Types of Classes. Types of BSC.

ANIMAL RESEARCH PRODUCTS. Biological Safety Cabinets Animal Transfer Stations

XPert Balance and Bulk Powder Enclosures

Thermo Scientific 1300 Series A2

Clean Air Products 90-Degree Low Profile Left Hand ADA Compliant Air Shower Purchase Specification

Labgard Class II, Laminar Flow Biological Safety Cabinet. Operation Manual

Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B.

Biological Safety Cabinets. Biological Safety Cabinets

Plant Growth Chamber MPGR14

Models: 1828 and and 1846

M Series Fan Filter Units

BIOLOGICAL SAFETY CABINET

CO2 INCUBATORS. The Safer Choice for Your Laboratory. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A. nuaire.com

S Series: Single-Phase Industrial Vacuums

Thermo Scientific MSC-Advantage Class II Biological Safety Cabinets. Good for you, good for the environment

Biological Safety Cabinet

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

CLEAR ROOM EQUIPMENT CLEAR ROOM EQUIPMENT AIR SHOWER PRESSURE RELIEF DAMPER PASS BOX PASS THOUGH CLEAN BENCH VERTICAL CLEAN BENCH HORIZONTAL

PART III. Laboratory equipment

Environmental Health and Safety Biological Safety Program Guidance Document

CV100T Dry Canister Vacuum. Technical Information & Safety Page 3, 4

Mobile Heated Cabinet

CLEAN AIR SYSTEM.

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Laboratory Automation & Robotic System Enclosures

IVF/ART Series Laminar Flow Cabinets

Gelaire BH-EN and UltraSafe cabinets

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

LABORATORY EQUIPMENT. Fume Hoods. Class II Biological Safety Cabinets. Carbon Filtered Enclosures. Ventilation Stations

Table of Contents. Laboratory Fume Hoods. UniFlow Fume Hood Systems. Fume Hood System Components. Custom Hoods, Enclosures & Cabinets

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

Microbiological Safety Cabinets

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

Room Air Purifier Class II Medical Device

Electrostatic Air Cleaners for Commercial and Industrial Applications

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

Bedding Disposal Workstations The Portable Safety Solution for Animal Research Laboratories. Viva Bedding Disposal Workstation, Model VBD-4A_.

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

UC DAVIS Campus Standards & Design Guide DIVISION 11 - EQUIPMENT

Animal Tissue Culture SQG 3242 Equipment and Lab design. Dr. SITI PAULIENA MOHD BOHARI

Manufacturer of HVAC Equipment Since ,000 sq. ft. on 16 acres. Colton, California USA

F116 (Series 16000) Self-Contained Ductable Commercial Air Cleaner

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

COMPETITIVE INITIATIVE POWDER COATING SPRAY SYSTEM MINES TECHNICAL SPECIFICATION

KVF - Capture Jet canopy with Supply Air and Side-Jet Technology KVF. Capture Jet Canopy with Supply Air and Side-Jet Technology

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

Thermo Scientific Necropsy Tables

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

FT900BD FLIGHT-TYPE DISHWASHER

INSTRUCTION MANUAL AMS WATER MANAGEMENT SYSTEM (AMS-WMS 230V) INSTRUCTION MANUAL AMS WMS 230V Manual Issue 1 15/10/09 Page 1 of 15

Class II Biosafety Cabinets

Florida International University. Biosafety Cabinet Program

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

L a b o r a t o r y E q u i p m e n t C a t a l o g

OPERATOR S MANUAL. Horizontal Laminar Flow Clean Bench

Modular Supply Make-Up Air Unit

HEALTHY HOME AIR PURIFICATION SYSTEM

KIC Air Curtains. Technical Guide


EXHAUST FAN FLOW METER AND TRUEFLOW AIR HANDLER FLOW METER

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR. Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand.

EHH SERIES DRAW THROUGH FAN COILS CFM

REQUIREMENTS FOR HOOD PLANS

Airstream Class II, Biological Safety Cabinet (E-series),

AIR SCRUBBER X-3400, X-3500, X-3700

Direct Gas-Fired Make-Up Air

General & Special Purpose Forensic Evidence Drying Cabinets

Transcription:

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A. 763.553.1270 www.nuaire.com

LabGard NU-602 Biological Safety Cabinet The LabGard NU-602 Class II Type A2 Biological Safety Cabinet/Cage Changing Station provides personnel, product, and environmental protection for sensitive animal handling and cage changing procedures. Built to withstand the rigors of use in an animal facility, the NU-602 is both mobile and height adjustable with the following key features: Safety Greater visibility and reach through a large 12 access opening along with Class II Type A2 biohazard containment through a 105 FPM air barrier across the front access opening (optional 13.5 access/105 FPM air barrier to accommodate taller rat cages). Uni-directional laminar airflow minimizes air turbulence or cross contamination between animals. All contaminated ducts, plenums, and gaskets are under negative pressure or surrounded by negative pressure to eliminate the possibility of cabinet or gasket leaks and to guard against HEPA failure. Ergonomic Auto-Lift Electronically adjustable work surface height from 31 to 38 (42 with optional 4 base risers) accommodates the ergonomic needs of multiple users who may be sitting or standing. As a console-style cabinet with the motor/blower located in the base, the low profile of the NU-602 is ideal for animal holding rooms with low ceilings and doorways. NU-602 - Model shown with decorative front panel, refuse disposal, and dirty cage collection options. HEPA Filtration High Efficiency Particulate Air (HEPA) filtration is 99.99% efficient on removal of particulates for supply (re-circulated) and exhausted air. High-capacity blower protects filter and extends filter life by providing a minimum 150% increase in static pressure across the HEPA filter. Adjustable internal damper and motor speed control further extend HEPA filter life. Pre-filters capture bedding, hair and dander and are easy to access for cleaning underneath the prop up work tray. [A] ESSENTIALS Control System includes a Minihelic pressure gauge, motor voltage regulator, main and outlet power circuit breakers, and power switches for fluorescent lights and/or ultraviolet lights, interior outlets, and blower motor. [A]

Airflow Exhaust HEPA ACCESS PANEL Service control center (Removable, contains all Cabinet Controls) Supply hepa access panel FLuorescent lamp (REar wall) 12 High work access Hepex pressure duct (Vacuum outside duct) spill through pre-filter push/pull bar (2) perforated diffuser perforated front grille Room Air Cabinet base (vacuum) Clean HEPA Filtered Air Contaminated Air Heavy-duty casters Recirculated Air

LabGard NU-602 Biological Safety Cabinet 3 Configurations Available 1 Dirty Cage Collection Option Pass-through feature allows operator to place dirty cages from cage-changing procedure through a door in side wall and into a biohazard bag for transport to autoclave. The pass-through door is completely removable for cleaning and can accommodate both mouse and rat cages. Class II biohazard containment is maintained through the cage collection process. NU-602 - Model shown with decorative front panel, refuse disposal, and dirty cage collection options. Available on all sizes. 2 Refuse Disposal Option Convenient system located below work surface allows user to dispose of animal bedding and waste under Class II containment conditions. Double bag disposal system includes outer bag fastened to underside of plenum with metal ring; inner bag fits snugly to work tray to hold refuse. Waste is collected in a 22 gallon can that sits on a platform with castors. Available on six-foot models only. 3 Sterile Cage Delivery Option Autoclaved, sterile cages are placed in the sterile cage delivery system where wraps are removed in clean airstream. Sterile cages are easily accessed by the operator through the cabinet work surface as the spring-balanced platform moves cages vertically into position. Delivery system can maintain up to 50 stacked disposable mouse cages in sterile bags. Available on six-foot models only.

LabGard NU-602 Biological Safety Cabinet Specifications Catalog Number Performance Specifications: Personal Protection Product Protection NU-602-400 Nominal 4 Foot (1.2 m) NU-602-500 Nominal 5 Foot (1.5 m) NU-602-600 Nominal 6 Foot (1.8 m) NSF Std. No. 49 Class Class II, Type A2 Class II, Type A2 Class II, Type A2 Style of Cabinet Console Console Console Cabinet Construction Pressure Tight Design All Welded Stainless Steel 16 GA, Type 304 14 GA CRS Base All Welded Stainless Steel 16 GA, Type 304 14 GA CRS Base All Welded Stainless Steel 16 GA, Type 304 14 GA CRS Base Diffuser for Air Supply (Metal) Non-flammable Non-flammable Non-flammable HEPA Filter Seal Type: Supply Filter - 99.99% Eff. on 0.3 Microns Exhaust Filter - 99.99% Eff. on 0.3 Microns HEPEX Seal* Neoprene, Spring-loaded HEPEX Seal* Neoprene, Spring-loaded Fumigation per NIH/NSF Procedure Yes Yes Yes HEPEX Seal* Neoprene, Spring-loaded Standard Services: Gas Cocks ( 3 /8 inch NPT) Duplex Outlet Optional Services: Gas Cocks ( 3 /8 inch NPT) Duplex Outlets Ultraviolet Light Cabinet Size, Inches (mm): Height Width Depth Work Access Opening: Standard Opening Height, Inches (mm) Standard Inflow Velocity (DIM) Work Zone, Inches (mm): Height Width Depth Up to Three Each, Side Wall One Each, Side Wall One, Back Wall 77 (1956) 50 1 /2 (1283) 31 3 /4 (806) 12 (305) 105 FPM (.53 m/s) 26 1 /2 (673) 46 1 /2 (1232) 24 1 /2 (622) Up to Three Each, Side Wall One Each, Side Wall One, Back Wall 77 (1956) 62 1 /2 (1588) 31 3 /4 (806) 12 (305) 105 FPM (.53 m/s) 26 1 /2 (673) 58 1 /2 (1486) 24 1 /2 (622) Up to Three Each, Side Wall One Each, Side Wall One, Back Wall 77 (1956) 74 1 /2 (1588) 31 3 /4 (806) 12 (305) 105 FPM (.53 m/s) 26 1 /2 (673) 70 1 /2 (1791) 24 1 /2 (622) Hinged, Tempered Glass Viewing Window, Inches (mm) 12 (305) Opening 12 (305) Opening 12 (305) Opening Minimum Exhaust Flow Standard 407 CFM (629 CMH) 512 CFM (870 CMH) 617 CFM (1048 CMH) Plant Duct Static Pressure, Inches 0.05-0.1 H 2 O 0.05-0.1 H 2 O 0.05-0.1 H 2 O Heat Rejected, BTUs per Minute 24 35 43 Electrical: 115 V (230 V) Volts, AC (60 / 50 Hz) Amps: Blower/Lights Amps: Duplex Amps: Total 12 ft Power Cord (One) UL / UL-C Listed (115 V Only) 115 / 60 (230 / 50, 60) 10 (7) 3 (3) 13 (10) 12 GA - 3 Wire, 20 A UL / UL-C Listed (115 V Only) 115 / 60 (230 / 50, 60) 12 (8) 3 (3) 15 (11) 12 GA - 3 Wire, 20 A UL / UL-C Listed (115 V Only) 115 / 60 (230 / 50, 60) 12 (8) 3 (3) 15 (11) 12 GA - 3 Wire, 20 A Net Weight Crated Shipping Weight* 780 lbs (354 kg) 815 lbs (370 kg) 880 lbs (400 kg) 915 lbs (415 kg) 980 lbs (445 kg) 1015 lbs (460 kg) Standard Features HEPEX Pressure System Fluorescent Lighting Optional Features Ultraviolet Light Locking Swivel Casters (Low Profile, Stainless Steel) Electric Auto-lift Stainless Steel Interior Removable Work Tray Liquid Drain Valve 12 Access Opening (305 mm) 105 LFPM Air Barrier (0.53 m/s) Tempered Glass View Screen Pre-Filter System Magnehelic Gauge Decorative Front Panel Ground Fault Interrupter Service Valves Three Optional Configurations Custom Solutions All models are designed to meet UL, CUL, and CE criteria for safety and performance. *Crated shipping weight does not include weight for accessories or options

For more information please visit www.nuaire.com or call 1.800.328.3352 Process # 9-1213P Rev. 1 5/11