SVENSK STANDARD SS-EN :2004

Similar documents
Smoke and heat control systems Part 1: Specification for smoke barriers

Massa Våtuppslagning på laboratoriet Del 1: Våtuppslagning av kemisk massa (ISO :2004)

SVENSK STANDARD SS-EN ISO 13897:2005. Tandvård Amalgamkapslar (ISO 13897:2003) Dentistry Amalgam capsules (ISO 13897:2003)


Skyddshandskar för brandmän. Protective gloves for firefighters


Blodtrycksmätare för indirekt blodtrycksmätning. Del 3: Särskilda krav för elektromekaniska mätsystem

SVENSK STANDARD SS-EN 4616:2005. Aerospace series Magnesium alloy MG-C18002 T4 Chill casting. Fastställd Utgåva 1

SVENSK STANDARD SS-EN ISO :2006

SVENSK STANDARD SS-EN 2256:2004. Aerospace series Aluminium alloy AL-P2618A T852 Hand and die forgings a 150 mm. Fastställd Utgåva 1

Inredning Köksinredning och apparater Måttsamordning. Kitchen furniture Co-ordinating sizes for kitchen furniture and kitchen appliances



Glaskärl Halsringar Del 3: 38 normal (ISO :2005) Glass containers Vacuum lug finishes Part 3: 38 regular (ISO :2005)

SVENSK STANDARD SS-EN ISO 15652:2005. Båtar Styrsystem för småbåtar med inombordsvattenjetmotorer

Kallvalsade smala stålband Toleranser för dimensioner och form

SVENSK STANDARD SS-EN :2005. Rörflänsar Flänsförband Skruvförband Del 3: Klassificering av material för stålflänsar, klassbetecknade

Glass packaging Hand-held crown bottle openers Dimensions

Vägutrustning Vägmärken Variabla meddelandeskyltar Del 3: Produktionskontroll

SVENSK STANDARD SS-EN ISO 15065:2005. Fästelement Försänkningar för skruvar med sänkhuvud utformat enligt ISO 7721 (ISO 15065:2005)

SVENSK STANDARD SS-EN 10021:2007. Allmänna tekniska leveransbestämmelser för järn- och stålprodukter

SVENSK STANDARD SS-EN :2004

SVENSK STANDARD SS-EN :2004

SVENSK STANDARD SS-EN ISO :2005. Kvalitetskrav för smältsvetsning av metalliska material Del 2: Omfattande kvalitetskrav (ISO :2005)


SVENSK STANDARD SS-EN ISO :2007. Anestesi- och ventilationsutrustning Koniska kopplingar Del 2: Gängade belastningsbara kopplingar

SVENSK STANDARD SS-EN 365:2004

SVENSK STANDARD SS-EN :2006

SVENSK STANDARD SS-EN 14286:2005. Aluminium och aluminiumlegeringar Svetsbara valsade produkter för tankar för transport och lagring av farligt gods

SVENSK STANDARD SS-EN ISO :2006


Transportörer Transportband Elektrisk ledningsförmåga Specifikation och provningsmetod (ISO 284:2003)

Explosiv atmosfär Trycktålig utrustning. Explosion resistant equipment

SVENSK STANDARD SS-EN ISO :2005. Mjukpapper och mjukpappersprodukter Del 5: Bestämning av våtstyrka (våtdragstyrka) (ISO :2005)

SVENSK STANDARD SS-EN :2004

SVENSK STANDARD SS-EN ISO :2007. Motståndssvetsning Mätning av svetsström Del 4: Kalibreringssystem (ISO :2005)


SVENSK STANDARD SS-EN ISO :2005

SVENSK STANDARD SS-EN 54-7/A2:2006

Järn och stål Bestämning av härddjup vid ythärdning

Förpackningar Transportförpackningar för farligt gods Återvunnet plastmaterial (ISO 16103:2005)

SVENSK STANDARD SS-EN ISO Tandvård Dentala material Legeringspulver (alloys) för amalgam (ISO 1559: Technical Corrigendum 1:1997)

SVENSK STANDARD SS-EN :2004


SVENSK STANDARD SS-EN ISO 15880:2004. Färg, lack och bindemedel Bestämning av MEQ-värde för vattenburna färger och bindemedel

Road traffic noise reducing devices Specifications

SVENSK STANDARD SS-EN ISO :2005. Kvalitetskrav för smältsvetsning av metalliska material Del 2: Omfattande kvalitetskrav (ISO :2005)

SVENSK STANDARD SS-EN :2006

Welding of thermoplastics Machines and equipment for hot gas welding (including extrusion welding)

Personlig fallskyddsutrustning Helselar. Personal protective equipment against falls from a height Full body harnesses


Fönster och dörrar Mekanisk livslängd Krav och klassificering. Windows and pedestrian doors Mechanical durability Requirements and classification

SVENSK STANDARD SS-EN 10021:2007. Allmänna tekniska leveransbestämmelser för järn- och stålprodukter

Machines and plants for the manufacture, treatment and processing of flat glass Safety requirements Part 11: Drilling machines

Free-standing chimneys Part 6: Steel liners Design and execution


Glasfasader Lufttäthet Prestandakrav och klassificering

SVENSK STANDARD SS-EN 2732:2005. Aerospace series Magnesium alloy MG-C46001-T6 Chill casting. Fastställd Utgåva 1

Provning av sprutbetong Del 7: Fibermängd hos fiberarmerad betong

SVENSK STANDARD SS-EN ISO 7458:2004. Förpackningar Glasbehållare Hållfasthet mot inre tryck Provningsmetoder (ISO 7458:2004)

SVENSK STANDARD SS-EN Stållinor Säkerhet Del 9: Slutna bärlinor för linbaneanläggningar för persontransport

Skyddshandskar för svetsare. Protective gloves for welders


SVENSK STANDARD SS-EN

Träbaserade skivor Ythållfasthet Provning. Wood-based panels Surface soundness Test method

Plast Formsprutning av provkroppar av termoplast Del 3: Små plattor (ISO 294-3:2002)

SVENSK STANDARD SS-EN :2006

Värmesystem i byggnader Utformning och installation av direktverkande rumsvärmesystem

SVENSK STANDARD SS-EN Eldfasta massor Del 8: Bestämning av kompletterande egenskaper

SVENSK STANDARD SS-EN :2006

SVENSK STANDARD SS-EN 14332:2004

SVENSK STANDARD SS-EN ISO 8325:2004. Tandvård Roterande instrument Provningsmetoder. Dentistry Test methods for rotary instruments (ISO 8325:2004)

Aerospace series Aluminium alloy AL-P6061-T651 Plate 6 mm < a 80 mm

Explosives for civil uses Propellants and rocket propellants Part 7: Determination of properties of black powder

Fästelement Blindnitar av splinttyp med genomgående hål och sänkhuvud AIA/St (ISO 15978:2002)

SVENSK STANDARD SS-EN ISO 8987:2005. Plast Fenolharts Bestämning av reaktivitet på en B-transformationsprovplatta (ISO 8987:2005)

Golvmaterial Sportbeläggningar Bestämning av vattenabsorption från obundna mineraler

Skodon Provningsmetoder för hel sko Tvättbarhet i tvättmaskin avsedd för privat bruk (ISO 19954:2003)

Textiles Solar UV protective properties Part 2: Classification and marking of apparel

SVENSK STANDARD SS-EN ISO 15465:2004. Rörledningar Spirallindade metallslangar och slanganslutningar (ISO 15465:2004)

Skodon Provningsmetoder för klackar Hållbarhet för klackstift (ISO 19957:2004)

SVENSK STANDARD SS-EN 1507:2006

Golvmaterial Mätning av dynamisk friktionskoefficient

SVENSK STANDARD SS-EN ISO :2006. Plast Metoder för exponering i artificiellt ljus Del 2: Xenon-arc ljuskällor (ISO :2006)

SVENSK STANDARD SS-EN

SVENSK STANDARD SS-EN ISO 2247

SVENSK STANDARD SS-EN 13827:2004. Transportband med stålstomme Bestämning av vertikal och tvärförflyttning av stållinor

Fästelement Plana rundbrickor Produktklass A (ISO 7089:2000) Plain washers Normal series Product grade A (ISO 7089:2000)


SVENSK STANDARD SS-EN 646:2006. Papper och papp avsedda att komma i kontakt med livsmedel Bestämning av färghärdighet hos färgat papper och papp

Skodon Provningsmetoder för klackar Utmattningshållfasthet (ISO 19956:2004) Footwear Test methods for heels Fatigue resistance (ISO 19956:2004)

SVENSK STANDARD SS-EN Fönster Mjuk och tung stöt Provningsmetod, säkerhetskrav och klassificering

SVENSK STANDARD SS-EN 26/A2:2005. Gasutrustningar Varmvattenberedare av genomströmningstyp med atmosfärbrännare

SVENSK STANDARD SS-EN Skodon Provningsmetoder för ovanläder, foder och inläggssulor Avfärgning

SVENSK STANDARD SS-EN 13421:2006

SVENSK STANDARD SS-EN :2004

SVENSK STANDARD SS-EN

Transcription:

SVENSK STANDARD SS-EN 14511-2:2004 Fastställd 2004-05-28 Utgåva 1 Luftkonditioneringsaggregat, vätskekylare och värmepumpar, med elmotordrivna kompressorer, för rumsuppvärmning och -kylning Del 2: Provningsförhållanden Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling Part 2: Test conditions ICS 23.120; 27.080 Språk: engelska Publicerad: augusti 2004 Copyright SIS. Reproduction in any form without permission is prohibited.

Europastandarden EN 14511-2:2004 gäller som svensk standard. Detta dokument innehåller den officiella engelska versionen av EN 14511-2:2004. Denna standard tillsammans med SS-EN 14511-1, SS-EN 14511-3 och SS-EN 14511-4 ersätter SS-EN 12055, utgåva 1. Standarden ersätter tillsammans med SS-EN 14551-3 även SS-EN 255-2, utgåva 1 och SS-EN 814-2, utgåva 1. The European Standard EN 14511-2:2004 has the status of a Swedish Standard. This document contains the official English version of EN 14511-2:2004. This standard together with SS-EN 14511-1, SS-EN 14511-3 and SS-EN 14511-4 supersedes the Swedish Standard SS-EN 12055, edition 1. This standard together with SS-EN 14511-3 also supersedes the Swedish Standards SS-EN 255-2, edition 1 and SS-EN 814-2, edition 1. Upplysningar om sakinnehållet i standarden lämnas av SIS, Swedish Standards Institute, telefon 08-555 520 00. Standarder kan beställas hos SIS Förlag AB som även lämnar allmänna upplysningar om svensk och utländsk standard. Postadress: SIS Förlag AB, 118 80 STOCKHOLM Telefon: 08-555 523 10. Telefax: 08-555 523 11 E-post: sis.sales@sis.se. Internet: www.sis.se

EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM EN 14511-2 May 2004 ICS 23.120 Supersedes EN 12055:1998, EN 255-2:1997, EN 814-2:1997 English version Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 2: Test conditions Climatiseurs, groupes refroidisseurs de liquide et pompes à chaleur avec compresseur entraîné par moteur électrique pour le chauffage et la réfrigération - Partie 2 : Conditions d'essai Luftkonditionierer, Flüssigkeitskühlsätze und Wärmepumpen mit elektrisch angetriebenen Verdichtern für die Raumheizung und -kühlung - Teil 2: Prüfbedingungen This European Standard was approved by CEN on 30 April 2004. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2004 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14511-2:2004: E

EN 14511-2:2004 (E) Provläsningsexemplar / Preview Contents page Foreword... 3 1 Scope... 4 2 Normative references... 4 3 Terms and definitions... 4 4 Test conditions... 5 4.1 Environmental conditions and electrical power supply requirements... 5 4.2 Rating conditions... 5 Annex A (normative) Energy labelling application... 12 A.1 General... 12 A.2 Rating conditions... 12 A.2.1 General... 12 A.2.2 Air-cooled air conditioners (air-to-air conditioners)... 12 A.2.3 Single-duct air conditioners... 12 A.2.4 Water-cooled air conditioners (water-to-air conditioners)... 12 A.2.5 Other appliances... 13 A.3 Test procedure... 13 A.4 Tolerances permitted on declared values... 13 A.4.1 General... 13 A.4.2 First testing... 13 A.4.3 Second testing... 13 Annex ZA (informative) Relationship of this document with EC Directives... 14 Bibliography... 15 2

EN 14511-2:2004 (E) Foreword This document (EN 14511-2:2004) has been prepared by Technical Committee CEN/TC 113 Heat pumps and air conditioning units, the secretariat of which is held by AENOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by November 2004, and conflicting national standards shall be withdrawn at the latest by November 2004. This document supersedes EN 255-2:1997, EN 814-2:1997, EN 12055:1998. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative annex ZA, which is an integral part of this document. This standard consists of the following parts: Part 1: Part 2: Part 3: Part 4: Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 1: Terms and definitions. Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 2: Test conditions. Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 3: Test methods. Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 4: Requirements. Annex A is normative. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. 3

EN 14511-2:2004 (E) Provläsningsexemplar / Preview 1 Scope This part of EN 14511 specifies the test conditions for the rating of air and water cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and/or cooling. It also specifies test conditions for heat recovery operation of multisplit systems. This European Standard applies to factory-made units that can be ducted. This standard applies to factory-made liquid chilling packages with integral condensers or for use with remote condensers. This standard applies to factory-made units of either fixed capacity or variable capacity by any means. Packaged units, single split and multisplit systems are covered by this standard, except water cooled multisplit systems. In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser. This standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement. This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side. The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard. This standard does not apply to units using transcritical cycles, e.g. with CO 2 as refrigerant. Installations used for heating and/or cooling of industrial processes are not within the scope of this standard. NOTE Part load testing of units is dealt with in CEN/TS 14825. 2 Normative references This European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text, and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies (including amendments). EN 14511-1:2004, Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 1: Terms and definitions. EN 14511-3:2004, Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 3: Test methods. EN 14511-4:2004, Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 4: Requirements. 3 Terms and definitions For the purposes of this European Standard, the terms and definitions given in EN 14511-1:2004 apply. 4

EN 14511-2:2004 (E) 4 Test conditions 4.1 Environmental conditions and electrical power supply requirements The tests shall be carried out under the environmental conditions specified in Table 1 or Table 2 depending on the location of the unit. For all units, electrical power voltage and frequency shall be given by the manufacturer. Table 1 Environmental conditions for units designed for installation indoor Type Measured quantities Rating test Water-to-water units 15 C to 30 C Air-to-water units with duct connection on the air inlet and outlet side Air-to-water units without duct connection on the air inlet side Water-to-air units with duct connection on the air inlet and outlet side Water-to-air units without duct connection on the air inlet and outlet side Air-to-air units with duct connection on the indoor air inlet and outlet side Air-to-air units without duct connection on the indoor air inlet and outlet side 15 C to 30 C 15 C to 30 C 15 C to 30 C Table 9 or Table 10 Table 5 or Table 6 Table 3 or Table 4 Table 2 Environmental conditions for units designed for installation outdoor Type Measured quantities Rating test Air-to-water units Water-to-air units without duct connection on the air inlet side Air-to-air units with duct connection on the indoor air inlet and outlet side Table 9 and Table 10 Table 5 and Table 6 Table 3 and Table 4 4.2 Rating conditions For the rating tests, the appropriate test conditions shall be applied in accordance with: Table 3 for air-to-air units in heating mode; Table 4 for air-to-air units in cooling mode; Table 5 for water-to-air units in heating mode; 5

EN 14511-2:2004 (E) Provläsningsexemplar / Preview Table 6 for water-to-air units in cooling mode; Table 7 for water-to-water units in heating mode; Table 8 for water-to-water units in cooling mode; Table 9 for air-to-water in heating mode; Table 10 for air-to-water in cooling mode; Table 11 for liquid chilling packages with remote condenser; Table 12 for liquid chilling packages for heat recovery condenser; Table 13 for basic, multiple circuit and modular multisplit systems in the heating mode; Table 14 for basic, multiple circuit and modular multisplit systems in the cooling mode; Table 15 for modular heat recovery multisplit systems. For units with brine, the test shall be carried out with the brine specified by the manufacturer, see 7.2.1 of EN 14511-4:2004. Table 3 Air-to air heat pumps. Heating mode Standard rating Conditions Application rating conditions Outdoor heat exchanger Inlet dry bulb Inlet wet bulb temperature temperature C C Indoor heat exchanger Inlet dry bulb Inlet wet bulb temperature temperature C C Outdoor air / recycled air 7 6 20 15 max Exhaust air / recycled air 20 12 20 12 Exhaust air / outdoor air 20 12 7 6 Outdoor air / recycled air 2 1 20 15 max. Outdoor air / recycled air - 7-8 20 15 max. Outdoor air / recycled air - 15-20 15 max. Exhaust air / outdoor air 20 12 2 1 Exhaust air / outdoor air 20 12-7 - 8 6