BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

Similar documents
WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

KDE. PRESSURIZED STAINLESS STEEL CONDENSING BOILER FROM 124 kw TO 2160 kw

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

The mechatronics of EVE 05

ACCUMULATION OF EUROPEAN CLASS

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

white blue cobalt bordeaux light oak (rovere)

Ideasandformsinevolution

THE PERFECT CONDENSATION

Ciao Green Condensing Wall-Hung Boilers

SPECIFICATIONS - NIKE

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

1 VICTRIX ZEUS Superior kw I features

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

Flue gas condensation...

Power X High Power Condensing Wall-Hung Boilers

ENERGY TOP. Condensing boiler solutions

Power X High Power Condensing Wall-Hung Boilers

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

AIREX 2S WOOD PYROLYSIS SUCKING FAN

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

Condensing, pre-mixed, wall-hung gas boilers with water tank

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

C Tahiti. condensing

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

MODULAR GAS CONDENSING UNIT EQUIPPED WITH PRIMARY RING and premix modulating Low NO x. from 100 to 900 kw and in battery up to 8 units

MODULEX EXT ENBLOC MODULATING BOILER

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Mynute Green Condensing Wall-Hung Boilers

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

Residential Heating Boilers

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

STILE BEAUTY AND TECHNOLOGY

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Seradens Super Seradens Super Plus

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

High quality... SEALED PRE-MIXED MODULATING FAN SPECIAL METAL FIBRE BURNER FLAME DETECTION ELECTRODE IGNITION ELECTRODE FLUE OUTLET

PCH/new Series. High performance, total flexibility

Exclusive Green E Condensing Wall-Hung Boilers

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

THE PERFECT CONDENSATION

TAHITI CONDENSING KR 55 - KR 85

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

UP TO 35 kw HE Collection

WOLF GAS CONDENSING BOILERS COMFORTLINE

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

The iqe Boiler Range. Combination and System T Boilers.

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

The guarantee on this appliance is valid for 12 months from the first day of installation.

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

INSTRUCTION FOR THE USER THC V E OIL BLU

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

WHE 2.24 / WHE 2.24 FF

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

Floor standing boilers. RMG Mk.II RS Mk.II

International Markets. Product Catalogue. complementary items

PRODUCT CATALOGUE

Bluehelix Tech RRT Wall-hung condensing boiler with Ferroli Thermobalance heat cell

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

MYdens T 5WARRANTY 1:20. Ti TITANIUM. commercial gas condensing boilers. boilers from 60 to 280 kw AISI 316 YEARS WORKING PRESSURE HEAT EXCHANGER

Bluehelix Tech Wall-hung premix condensing boilers, only heating or instant combi operation

Tower Green HE Hybrid

4FLOOR-STANDING GAS CONDENSING BOILERS

Heating and D.h.w. Controller RVL482 Basic Documentation

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

HIGH OUTPUT. Skin design RANGE

RIELLO 40 GS/M SERIES

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

INSTALLATION AND MAINTENANCE INSTRUCTIONS INSTALLATION AND SERVICING MANUAL

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Termo Fan. premix. Wall-hung gas furnaces. a G20 ENGINEERING brand

ALKON INSTALLATION AND SERVICING MANUAL 18 R 24 R - 24 C 28 R - 28 C 35 R - 35 C. English th edition - 02/2009

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

prestige Control Application Supplement - ACVMax

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

Prextherm Rsw High efficiency steel pressurised boilers

prestige Control Application Supplement - TriMax

Control Application. Supplement - ACVMax

LOW NOx MODULATING GAS BURNERS

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

G E N E R A L CATALOGUE

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

prestige Control Application Supplement - TriMax

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

MINORCA KC - KR - KRB 24

Transcription:

BWA CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

Professional From 50 kw to 70 kw EFFICIENCY CLASS (CE DIR. 92 / 42). Seasonal efficiencies up to 109% CLASS 5 Low NO x (EN 483) thanks to the pre-mixed burner with gas-air ratio control which offers a constant CO 2 content for the whole modulation range Al/Si/Mg exchanger/condenser Certification in output range Dimensions: h 93 cm, w 61,5 cm, d 26,6 cm Modulating ratio 1:7 - BWA 70, 1:5 - BWA 50 Standard interface for modulating heating controllers with communication protocol (bus-data) Coupling with a modulating pump (standard supply only for BWA 70) Optional accessories: thermoregulation, mixing header, additional safety devices, equipment for cascade mounting (up to 4 boilers), equipment for DHW production kit 90 kw EFFICIENCY CLASS (CE DIR. 92 / 42) Al/Si/Mg exchanger/condenser Anti-corrosion painted steel casing for indoor and outdoor floor standing installation Standard supplied modulating pump Certification in output range Protection degree IP X5D Possibility of cascade mounting (up to 4 boilers) Max input 90 kw, min. 22 kw 140 kw EFFICIENCY CLASS (CE DIR. 92 / 42). Seasonal efficiencies until 104,3% CLASS 5 Low NO x (EN 483) thanks to ready-mixed modulating burner with fixed combustion 2 Al/Si/Mg exchanger/condenser with anticorrosion anodization treatment Certification in output range Dimensions: h 128 cm, w 76 cm, d 47 cm Standard supplied modulating pump: modulating ratio 1:13 Just one common smokes evacuation Twin safety switch (emergency working) Wall-hung units with self supporting metallic structure suitable also for floor standing Optional accessories: thermoregulation, mixing header, additional safety devices, equipment for cascade mounting (up to 4 boilers) MODEL BWA 50 BWA 70 BWA 90 BWA140 nominal output condensing mode kw 49,3 10,3 68,5 10,3 93,6 24,0 136 11,5 max/min conventional mode kw 47,2 9,1 65,5 9,1 87,5 21,1 131,6 10,5 effi ciency category (Dir. 92/42)

Cascade mounting 50-70 kw modules - up to 280 kw 9 9a 9a 2 1 7 6 3 10 8 5 3a 3a 4 BATTERY COMPOSITION + PRIMARY CIRCUIT - description of the components as shown in the picture 1 - BWA 50 for gas natural or LPG - BWA 70 for gas natural or LPG 2 - E8 heating controller 3 - Supporting frame for 2 units 3A - Expansion frame for 1 unit 4 - Manifolds Kit 5 - Pipes for safety devices kit 6 - Safety devices Kit 7 - Mixing header Kit until 150 kw - Mixing header Kit from 180 to 450 kw 8 - Adaptation pipes Kit until 150 kw - Adaptation pipes Kit from 180 to 450 kw 9 - Smokes evacuation Kit for 2 units in pps (inspection kit included) DN 160 9A - Expansion smokes evacuation Kit for 1 unit in pps DN 160 - Smoke thermostat 10 - Blind fl anges Kit - Modulating Pump (only for BWA 50: to be ordered eparately for supply completion)

Cascade mounting 90 kw modules - up to 360 kw 3 9 5 1 4 10 11 6 2 2 2 8 7 composizione con attacco destro BATTERY COMPOSITION + PRIMARY CIRCUIT - description of the components as shown in the picture 1 - BWA 90 master - natural gas LPG 2 - BWA 90 combined with master (except boiler side panels, blind fl anges, bolts, top cover for one unit) natural gas - LPG 3 - Top cover for 2 units + frame extensions - Top cover for 3 units + frame extensions - Top cover for 4 units + frame extensions - Top cover for 5 units + frame extensions - Kit for indoor installations for 2 units 4 - Header until 180 kw dn 65 - Header until 360 kw dn 100 5 - Header connection kit DN 65 on the right - Header connection kit DN 65 on the left - Header connection kit DN 100 on the right - Header connection kit DN 100 on the left 6 - Y shape fi lter DN 65 - Y shape fi lter DN 100 7 - Pipes for safety devices kit + hydraulic and gas manifolds 8 - Safety devices pipes kit 9 - Differential pressure switch kit for each module 10 - Outer casing for safety devices complete with support* - Empty casing kit* - Safety devices Kit (advisable for indoor) 11 - E8 heating controller * It is recommended to oreder the outdoor cover kit (provided with a cap for the unused drain) to protect the casing, whether empty or containig the additionl safety devices kit (pos. 9). If both cases are installed, a cover for two additional elements is needed. 140 kw modules - up to 560 kw 5 4 6 6 8 2 7 3 1 1 - Flow and return manifold kit 4 units 2 - Additional safety devices kit 3 - Mixing header kit 3/4 units 4 - Smoke thermostat kit 5 - Smoke evacuation for 2 units 6 - Smoke evacuation extension for 3/4 units (BWA 140) 7 - Differential pressure switch kit 8 - Control manager kit CM A 140 formed by: -cascade manage PCBr -visualizer/programmer HSCP -230/24 V adaptor

Features Premix Burners Combustion system with total premix burners equipped with: Modulating fan, controlled by the main electronic PCB, determined by the output request sucks the exact quantity of gas to be burnt, thus avoiding waste and giving very low polluting emissions Flat burner that ensures: long duration thanks to low thermal and mechanical stresses and to unalterable fiber woven ideal heat diffusion for radiation thanks its chemical-physical high combustion silence thanks to low pressures and to anti-resonance casing fan CONDENSATION HEAT Hot smokes generated by combustion, full of water vapour, passing through exchanger, releases heating, cool down and condensing they produce about a liter of water for every m 3 of burnered gas. The saved energy, called condensation heating or latent heat recycling determines an increasing of output and so, seasonal, until 30%. SELF-ADAPTATION The use of the premix burner provides the boiler with the capacity to adjust the output depending on the smoke side resistance, thus resolving any problems connected with the execution of the flue ducts. CONTROLS AND COMMANDS Electronic modulation: The temperature and output regulations, are automatically checked with the aid of modulating thermostats and external temperature sensors. Auto-diagnosis and safety: The powerful microprocessors on the panel board provide an exceptional level of safety and breakdown prevention, due to the auto-diagnosis in real time. Condensation drain Premix modulating fan Smokes evacuation Al/Si/Mg condenser/ exchanger Complementary functions Simplified manteinance Sliding temperature mode Frost protection mode Anti-jamming pump and diverting valve Post-circulation anti-overheating Chimney sweeper function External probe (optional) Thermoregulations Thermal elements disposition, allows to enter easily at all the components in case of extraordinary maintenance. In case of ordinary maintenance, it simplifies and abbreviates operation times, both for exchangers cleaning and starting devices and flame control.

Exchanger/condenser Constructed with an aluminium/silicon/magnesium alloy. Withstanding the corrosion of acid condensate and to guarantee a high thermal efficiency Dense fins on heat exchanger Low water content and low thermal inertia High speed of exchange Absence of overheating ng phenomen phenomena BWA A 50-70 AI/Si/Mg exchanger/condenser condenser BWA 90 AI/Si/Mg exchanger/condenser BWA WATER EFFICIENCY ACCORDING TO THE OUTPUT AND THE INTERVENTION OF THE MODULATING PUMP High modulation ratio power in all Schuster condensational boilers, ensure to the system the terms of maximum output, independently from the supplied value. The power will be regulate and reduced in proportion to the reduction of the charge without wasting any watt and saving fuel. Ratio modulation goes up to 1:60. Nominal Output (%) Power modulation 110 108 107 106 108,7 108,7 106 104 102 100 98 101,7 96 94 92 90 MAXIMUM POWER 100% MINIMUM POWER 20% DHW optional kit For the series 50/70 is foreseen an optional kit for the production of DHW, easily applicable on the R.H.side panel of the boiler, and connecting it to the flow and return through a three way priority valve. The electrical connection is made on the terminal block predisposed in the panel board. Constituted by a plate heat exchanger it assures a D.H.W. production of 23.8 l/min in the boiler of 50 kw and 29.5 l/min in the boiler of 70 kw, with a Delta T of 30 K and it has a rewarding factor (R factor) of four taps (according to the Standard EN 13203-1:2006), in a temperature regulation range between 35 and 60 C.

HSCP Thermoregulation Panel HSCP Equipped with a backlighted LCD display and a selector knob, it allows: an hourly weekly scheduling up to a maximum of 12 totally independent heating circuits (optionals) and a hot water accumulator an hourly scheduling of different kinds of activities the management of the DHW recirculation pump the anti-legionella function for both the boiler and the secondary circuits with special acessories. Management will be throught the SHC (Slave Heating Controller) multifunction optional boards, for CH and DHW circuits and auxiliary resources (relays with a timer, solar accumulators and so on) in order to meet the real needs of users, thus justifying performances and budget. As an alternative, two different communication and remote management standards are available as well: ebus and Modbus, intended for the connection to different control devices, in order to get remotely all their operational information, included the complete management of the diagnostic for the visualization and the reset of alarms. Moreover, on board, there are changeover switches and fuses for the insertion and protection of the 2 thermal elements. Thanks to the BCM (Burner Control Manager) interface board, it is available a control predisposition with a 0-10 volt signal, to adjust the power supplied from an external source, and connections for: - an external probe - a modulating and on/off pump control - a Modbus port - an alarm contact

E8 Thermoregulation (optional for 50-70-90 kw) It exploits the maximum power modulation and the maximum reachable condensation, allowing: System optimization: it assures the comfort temperature bringing forward the system ignition and the flame heating modifications, according to the user s settings and to the burner features. Fast temperature set: obtained by calculating the optimum ignition start-up time. This calculation can be carried out taking into consideration the outdoor temperature or the room temperature. Overheating protection: the boiler safety temperature is controlled through the follow-up of heating circulators functioning, in order to get rid of any thermal inertia. Self adaptation: it processes the data coming from the room probe, therefore, it adapts the generator warmth to the building features, according to the external temperature DHW management DHW management: programmable to get the maximum comfort or the highest savings and the fastest boiler temperature stability, raising the boiler temperature to the maximum set value. Antilegionella: it removes possible DHW pathogens, raising the boiler temperature to 60 C each 20 heating cycles or at least once a week. Boiler charging pump optimization: it switches on only if the boiler temperature is 5 C higher than storage tank temperature. variations and taking into account the building thermal inertia and additional heating gains (solar radiation, internal heating sources). Optimization of DHW (loading pump): it manages the different heating curves set for the 2 circuits: the setpoint temperature of the boiler is calculated according to temperature of the mixing circuit with the highest flow rate and to the distance between the two curves. Mixing valve opening time based on the characteristics of the servomotor. Number of burner ignitions Burner run hours Antifrost protection: the room temperature for all the heating circuits is set to 5 C and the DHW preparation temperature is 10 C. Swimming pools heating predisposition. Programming Daily or weekly programming: it manages various switching-ons and offs or reductions along the 24h. Control of 2 independent circuits with different features. Renewable energy boilers Possible integration with solar systems and/or biomass boilers.

Control panel BWA 50-70-90 Temperature increase key Reset key/ Error code display DHW set key Central heating adjustment key Temperature decrease key CH selection key Stand-by/ central heating Display The control panel is equipped with an alphanumerical display with 6 pre-selection keys, which enable the user to view the following information: Boiler operation boiler status; flow and return temperature error code User s parameters working temperature setting on/off central heating Service parameters maximum working temperature setting room thermostat (on/off) remote thermoregulation post circulation fan ignition speed Data readout global flow and return temperature DHW temperature (if a DHW storage tank is present) BCM Panel (optional) The BCM panel (Burner Cascade Manager) allows: control heat reque: regulates modulation and temperature level supervision of working status communication with central automation systems (PLC) warning alarm and boiler unlocking. emergency operations in case of E8 thermoregulation failure BCM Panel (Burner Cascade Manager)

Dimensions - Technical data 50 kw and 70 kw 930 UPPER VIEW 266 615 BOTTOM VIEW Key: R - Heating system return M - Heating system flow G - Gas inlet Sc - Condensate siphon drain outlet (aluminium body) Scf - Condensate evacuation (coming from evacuation smokes pipe) MODEL BWA 50 BWA 70 Output NOMINAL/MINIMUM OUTPUT IN CONDENSING MODE kw 49,3 / 10,3 68,5 / 10,3 NOMINAL/MINIMUM OUTPUT IN CONVENTIONAL MODE kw 47,2 / 9,1 65,5 / 9,1 NOMINAL/MINIMUM INPUT kw 48,5 / 9,6 67,5 / 9,6 Efficiency EFFICIENCY CLASS (Directive CEE 92/42) WATER EFFICIENCY at full load % 97,3 97,3 WATER EFFICIENCY at part load % 94,9 94,9 WATER EFFICIENCY at nominal load in CONDENSING MODE % 101,6 101,5 WATER EFFICIENCY at part load in CONDENSING MODE % 104,3 104,3 WATER EFFICIENCY at the min. modulating output (9,1 kw) IN CONDENSING MODE % 107,3 107,3 COMBUSTION EFFICIENCY at nominal load / part load % 97,8 / 98,4 97,4 / 98,4 STAND-BY LOSSES (min-max) % 0,2 / 0,51 0,2 / 0,12 Combustion CO 2 (min/max input) % 9,0/9,2 9,5/9,5 CO AT 0% OF O 2 (min) mg/kwh 19,7 19,7 NO X (value according to EN 297/A3 and EN 483) mg/kwh 33,9 34,68 CONDENSATE PRODUCTION max kg/h 7,8 10,87 NO X CLASS 5 5 APPLIANCE S FAMILY GAS CATEGORY II2H3P II2H3P Central Heating MIN/MAX OPERATING TEMP. in CH mode C 30 / 85 30 / 85 MIN/MAX PRESSURE in CH circuit bar 0,5-6 0,5-6 MIN. WATER FLOW RATE in CH circuit ( t 20 K) l/min 6,65 9,45 Weight NET WEIGHT kg 50 50 Electrical supply MAXIMUM ABSORBED POWER * (with modulating pump) W 172 290 ELECTRICAL SUPPLY / POWER CONSUMPTION V/Hz 230 / 50 230 /50 ELECTRICAL PROTECTION IP X4D X4D Suplied as a standard: wall mounting bracket - condensate drain siphon - PP smoke outlet pipe Ø 80 mm - wall-mounting dowels. BWA 50 kw is supplied without pump. Pump as a standard for 70 kw version.

Dimensions - Technical data 90 kw and 140 kw MODEL BWA 90 BWA 140 Output MIN/MAX NOMINAL OUTPUT IN CONDENSING MODE kw 93,6 24 136 / 11,5 MIN/MAX NOMINAL OUTPUT IN CONVENTIONAL MODE kw 87,5 21,1 131,6 / 10,5 MIN/MAX HEAT INPUT kw 90 22 135 / 11 Efficiency EFFICIENCY CLASS (Directive CEE 92/42) WATER EFFICIENCY AT NOMINAL LOAD in CONDENSING MODE % 104,0 100,5 WATER EFFICIENCY AT PART LOAD in CONDENSING MODE % 109,1 104,3 WATER EFFICIENCY AT NOMINAL LOAD in CONVENTIONAL MODE % 97,26 97,5 WATER EFFICIENCY AT PART LOAD in CONVENTIONAL MODE % 96,03 95,1 COMBUSTION EFFICIENCY AT NOMINAL LOAD / PART LOAD % 98,1 / 98,3 97,5/ 98,3 STAND-BY LOSSES (min-max) % 0,90 0,02 Combustion CO 2 % 8,8-9,1 9-9,1 CO AT 0% OF O 2 mg/kwh 21,5-104,4 49/139 NO x (VALUE ACCORDING TO EN 483) mg/kwh 35,62 68 MAX CONDENSATE PRODUCTION kg/h 14,54 21,8 NO x Class 5 5 APPLIANCE S GAS CATEGORY II2H3P II2H3P Central Heating MIN/MAX OPERATING TEMP. in CH mode C 30 / 85 25 / 85 MIN/MAX PRESSURE in CH circuit bar 0,5-8 0,5-6 MIN. WATER FLOW RATE in CH circuit T 20 K l/min 15,1 28,3 Electrical Supply MAXIMUM ABSORBED POWER W 303 560 ELECTRICAL SUPPLY / VOLTAGE / FREQUENCY V/Hz 230 / 50 230 / 50 ELECTRICAL PROTECTION IP X5D X4D Weight FRONT VIEW BWA 90 BWA 140 SIDE VIEW Key: R - CH system return DN 80 M - CH system flow DN 80 G - Gas inlet DN 50 Sc - Condensate drain Ø 32 mm FRONT VIEW Key: R - Return 2 M - Flow 2 G - Gas inlet 1 SIDE VIEW Svs - Drain safety valve Scond - Condensate drain DN 32 NET WEIGHT kg 135 150 BOTTOM VIEW UPPER VIEW Schuster declines any liability for the inaccuracies that may appear due to errors in transcription or printing. It also reserves the right to introduce those modifi cations to its products that it considers necessary or useful, without compromising the essential characteristics of the said products. Ed. 1-10/2014 - Cod. 50512

- via Padana Inferiore, 52/C - 29012 Caorso (PC) - Italy - ph. +39 0523 822541 - fax +39 0523 822258 e-mail: info@schusterboilers.com - www.schusterboilers.com