Pre-Fab Easy Installation For Model 0011-CF-USK Installation and Operating Instructions for Existing Homes Or Buildings with Standard Piping

Similar documents
Instruction Sheet 00 Variable Speed Delta T (00-VDT)

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

Instruction Sheet. Variable Speed - Outdoor Reset (00-VR) 00 Cartridge Circulator

Installation Guide

Instruction Sheet. Variable Speed - Solar (00-VT) 00 and Load Match Cartridge Circulators

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Comfort Series Instant Hot Water System

Installation and Operating Instructions

Instant Hot Water Dispenser Owner s Manual

WATERSHIELIJrM REVERSE OSMOSIS INSTALLA TION MANUAL ~ ~ ~ ~ ~ l ~ TO INSURE THIS PRODUCT AND THE INSTALLATION THEREOF. ~ ~ ~ ~ ~

Installation Instructions / Warranty

NS1100 / NS2200 Installation Guide & Owner s Manual

Installation Instructions / Warranty

IRON/TONES TM REQUIRED 2T1A TOOLS AND 1 MATERIALS T01-A INSTALLATION INSTRUCTIONS / SELF-RIMMING OR UNDERCOUNTER KITCHEN SINK K-6625

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

Installation, Operation, and Maintenance Manual

IMPORTANT! ank You! Model: Twist-In 100 GPD, 3-Stage RO Unit. Installation, Operation & Maintenance Guide

Industrial Vacuums, Inc

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

TUB AND SHOWER FAUCET

SUTTON 52 CEILING FAN

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

ispring Whole House Water Filter Systems USER S MANUAL

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

User s Manual and Operating Instructions

TOUCHDOWN 48 CEILING FAN

Solinder Single Lever Basin Faucet

WHOLE HOUSE FILTER &

2-Stage Under Counter Filtration System Model: WP-2 LCV

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

MKTF CRO-Series 5-Stage Reverse Osmosis System Installation and Maintenance Manual

1.6 GALLON ONE PIECE TOILET

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

Installation Instructions / Warranty. Metris 31060XX XX XX1

Sloan AQUS Installation Instruction, Operation, and Maintenance Guide

Installation Instructions / Warranty. Starck 10111XX XX XX1

INSTANT HOT WATER RECIRCULATING SYSTEM

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Downrod. Blades. Maintenance & Cleaning.

Installation & Operation Manual for WarmlyYours Towel Warmers

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

Alkaline RO System INSTALLATION MANUAL

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Installation Instructions / Warranty. Massaud

Installation Instructions / Warranty

READ AND SAVE THESE INSTRUCTIONS

User s Manual and Operating Instructions

Whole House Filter Model: WH-LD

IMPORTANT! ank You! Model: Twist-In 100 GPD 4-Stage RO/DI Unit. Installation, Operation & Maintenance Guide

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

Installation & Operation Manual for WarmlyYours Towel Warmers

Nachi Series TM Z6957-XL

Aquila Single Lever Vessel Faucet

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Installation Instructions / Warranty

e Bath Fan with Light User s Guide

52 SAN LUCAS CEILING FAN

How your hot water dispenser works

INSTALLATION INSTRUCTIONS TOOLS YOU WILL NEED GETTING STARTED

Juna Ceiling Fan JU54. Installation Instructions Instrucciones de instalación Instructions d installation

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Laundry Kit With flexi-neck faucet and storage cabinet

Sound Cover [ , , , ]

DS 2001 REVISED Humidifier Assembly and Instruction Manual

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Mixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50

e Bath Fan with Light User s Guide

Installation Manual. Models 99168, 99169, 99170

gamma pond Ultraviolet Sterilizers

SUPPLEMENTARY INSTRUCTIONS

Acrylic Claw Foot Tub


52 BARSTOW CEILING FAN

BARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

Chilipepper CP8000. Installation Instructions READ BEFORE INSTALLING:

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

Model EPWHP. How to install, operate and maintain your Water Heater Protector. Do not return unit to store

REVERSE OSMOSIS DRINKING WATER SYSTEM

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

INSTALLATION INSTRUCTIONS. Cubix Widespread Faucet Part #: 3204, 5204, 3304, 5304 HANDLE STYLES

Zero Waste Retrofit Kit Instruction

Installation Instructions Model: EB Single-Lever Lavatory Faucet

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

SPRINGHILL 44 CEILING FAN

15Hp/20Hp Deluxe Compressor-Dryer System

User s Manual and Operating Instructions

5-Stage Reverse Osmosis System

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Acrylic Claw Foot Tub

INSTALLATION MANUAL CT-200

Installation Instructions PP-AS20 Anti-Scale System

15-Year Limited Warranty

Transcription:

Instruction Sheet 102-153 Pre-Fab Easy Installation For Model 0011-CF-USK Installation and Operating Instructions for Existing Homes Or Buildings with Standard Piping Plant I.D. 001-1184 EFFECTIVE: June 15, 2015 TacoGenie TM is manufactured using the highest quality component parts available. Patented Integral Flow Checks (IFC) are built into each TacoGenie pump to prevent cold water from entering the hot water line. State-of-the-art electronics allow the TacoGenie to accurately sense temperature and automatically shut off the pump to maximize comfort and energy savings. TacoGenie saves energy and water. You can look forward to over 15 years of life expectancy with a Taco TacoGenie. www.tacocomfort.com A Taco resource saving product

Installation shall be in accordance with the manufacturer s instructions or warranty may be voided. IMPORTANT Operation of the TacoGenie without being plumbed into water lines may damage the pump and void the warranty. WARNING: In the event the retaining screws have been pulled out of the housing, DO NOT replace them. Use of any other screw may short out the stator windings, creating a risk of electrical shock. WARNING: To avoid electrical shock, disconnect the power supply to the circulator and the main electrical unit. CAUTION: When installing electrical connections, do not apply mechanical loads to the capacitor box; otherwise, retaining screws may be pulled out of the housing, making circulator unusable. PRE-INSTALLATION CHECKLIST 1. TacoGenie includes: Model 0011-CF, 0011-CF-USK 00 Cartridge circulating pump with built-in TacoGenie Electronics, power cord, Integral Flow Check (IFC) and mounting bracket Set of two (2) 3 4 " shut-off flanges, gaskets and bolts Starter button Set of two (2) 1 2 " x 3 4 " plumbing adapter tees (included with USK models only) Set of two (2) 3 4 " x 18" stainless steel flex lines (included with USK models only) 2. Tools you need: Pipe or crescent wrench Plier Wire strippers Phillips and flat head screwdrivers Drill and 5 8 inch drill bit 3. Best location for the TacoGenie: Typically, this would be at the fixture farthest away from the water heater, generally the kitchen or master bath room. If your hot water supply runs in two different directions from the water heater, you may need more than one TacoGenie. PUMP POSITION Circulator must be mounted with the motor in the horizontal position. Never install the circulator with the capacitor box below the motor. Be sure arrow on pump casing is pointing from left to right (hot water to cold water side) prior to connecting the flex lines. Note: T s and flex lines supplied by Taco provide maximum flow and performance. Alternative plumbing parts may restrict flow and delay hot water to fixtures.

INSTALLATION FOR THE CF-SERIES TACO GENIE MODEL 0011-CF-USK The two custom adapter T s are designed to simplify your installation to 1 2 " copper hot and cold supply lines. If you have plumbing other than as shown in these instructions, additional fittings may be required. Consult a plumbing professional. ELECTRICAL SUPPLY A 110V electrical supply outlet is required to power the TacoGenie unit. If an outlet is not available, install a 110V outlet in accordance with all local electrical codes. Caution: Do not plug in the TacoGenie until all plumbing and wiring connections are completed and water supply is turned on. Running the circulating pump without water may damage internal components and void warranty. PLUMBING INSTRUCTIONS USING USK- PLUMBING ADAPTER KIT 1. Turn off the house water supply at the main shut-off valve. 2. Open hot and cold faucets at the fixture chosen for installation. This will relieve water pressure from the hot and cold water lines. 3. Remove the hot and cold shut-off valve angle stops from the 1 2 " copper pipes located below the sink. Be sure to use a catch basin to drain water from hot and cold lines. Warning: To prevent scalding, use caution when removing valve on hot water line. For ease of installation, leave the existing compression ring and nut from the angle stops on the hot and cold water lines. 4. Remove the compression ring and nut from the adapter tees provided and slide on to opposite straight copper end. Attach the existing nut and ring to the threaded end of the tee and tighten firmly. 5. Connect the shut-off valves to the new compression ring and nut and tighten firmly. 6. Assemble shut-off flanges to 0011 pump as shown in Figure 3 and tighten firmly. 7. Attach the stainless steel flex lines to the 3 4 " threaded connection on the tees and the 3 4 " threaded connections on the pump shut-off flanges. Teflon tape is recommended for all threaded fittings. 1. Turn off water supply and remove angle stops. 2. Install tees and attach angle stops.

3. Attach shut-off flanges to pump. 4. Connect flex lines to tees. 5. Connect flex lines to pump. INSTALLING THE TACO GENIE STARTER BUTTON The manual starter button is a unique feature to the TacoGenie. Using the manual start button maximizes energy savings and controls operation only when there is a request for hot water. 1. Drill a 5 8 " hole into the desired location, typically the side or front of a vanity cabinet. 2. Insert the gray wire from the controller through the back side of the hole and connect it to the starter button. 3. Firmly insert the button into the drilled hole. Note: To operate the TacoGenie from other locations throughout the house, additional starters can be installed and spliced into the gray wire provided. Or for wireless remote operation, the Taco #554-1 transmitter/receiver kit can be easily installed. See WIRELESS REMOTE KIT OPTION below for instructions. 4. If wireless remote kit is not installed, use electrical tape or wirenuts to isolate the three leads (black, white and green) on the black wire. COMPLETING YOUR INSTALLATION 1. Turn on the water supply at the main. Check the system carefully for possible leaks. If leaks occur, check all compression and threaded connections and tighten firmly. Open hot and cold fixtures for one to two minutes to flush system completely. 2. Plug in the TacoGenie to the 110V electrical outlet. The pump will start automatically the first time only and run for a short time until a rise in temperature is detected by the thermal sensor. Pump will automatically shut off. Note: When the TacoGenie is operating a green LED located on the pump motor housing will illuminate. The green LED will only be on when the pump is activated and circulating water. 3. To test manual starter button, wait for hot water temperature to cool below 100 F (approximately 20-30 minutes). Press starter button to operate the pump. The TacoGenie should run for a short time and shut off automatically as in step 2 above. 4. Check hot water at the fixture for desired temperature. If hot water temperature is not satisfactory, refer to Trouble Shooting checklist section.

TROUBLESHOOTING DIAGNOSING SPECIFIC PROBLEMS PROBLEM POSSIBLE CAUSE REMEDY 1. The pump does not run when push button is pressed. Green LED does not illuminate. 2. The water is not hot enough. 3. There is hot water at the cold water tap. 4. Water is not hot enough when pump shuts down. 5. There is hot water in the cold water lines only A. No power at electrical outlet B. You ve plugged the controller into an electrical outlet controlled by a wall switch, (such as the outlet under many kitchen sinks that controls the garbage disposal.) C. Power cord is not secured to pump D. Wire to push button is not connected well E. The temperature setting is already sensing hot water so the pump is not being activated A. Pump was installed with water flow going in the wrong direction B. There is something in the piping that has blocked the flow of water A. The water temperature sensor is loose or dislodged B. The temperature sensitivity setting now in place is too low, so the pump is not shutting down soon enough A. The temperature sensitivity setting now in place is too high, and the pump is turning itself off too soon A. The pump is installed backwards Plug the controller into a hot outlet Shut off power, then make sure wires have good contact Call 1-401-942-8000 to reset sensitivity setting Check the arrows on the pump casing to make sure they point in the correct direction (see page 2) Check the piping for obstruction Check the connection of the water temperature sensor to make sure it is firmly attached to the plug and casing Call 1-401-942-8000 for reset information Call 1-401-942-8000 for reset information Reinstall the pump correctly

LIMITED WARRANTY STATEMENT Taco, Inc. will repair or replace without charge (at the company s option) any Taco 00 Series circulator or circulator part which is proven defective under normal use within three (3) years from the date of manufacture. In order to obtain service under this warranty, it is the responsibility of the purchaser to promptly notify the local Taco stocking distributor or Taco in writing and promptly deliver the subject product or part, delivery prepaid, to the stocking distributor. For assistance on warranty returns, the purchaser may either contact the local Taco stocking distributor or Taco. If the subject product or part contains no defect as covered in this warranty, the purchaser will be billed for parts and labor charges in effect at time of factory examination and repair. Any Taco product or part not installed or operated in conformity with Taco instructions or which has been subject to misuse, misapplication, the addition of petroleum-based fluids or certain chemical additives to the systems, or other abuse, will not be covered by this warranty. If in doubt as to whether a particular substance is suitable for use with a Taco product or part, or for any application restrictions, consult the applicable Taco instruction sheets or contact Taco at (401-942-8000). Taco reserves the right to provide replacement products and parts which are substantially similar in design and functionally equivalent to the defective product or part. Taco reserves the right to make changes in details of design, construction, or arrangement of materials of its products without notification. TACO OFFERS THIS WARRANTY IN LIEU OF ALL OTHER EXPRESS WARRANTIES. ANY WARRANTY IMPLIED BY LAW INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS IS IN EFFECT ONLY FOR THE DURA- TION OF THE EXPRESS WARRANTY SET FORTH IN THE FIRST PARAGRAPH ABOVE. THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR STATUTORY, OR ANY OTHER WARRANTY OBLIGATION ON THE PART OF TACO. TACO WILL NOT BE LIABLE FOR ANY SPE- CIAL, INCIDENTAL, INDIRECT OR CONSE- QUENTIAL DAMAGES RESULTING FROM THE USE OF ITS PRODUCTS OR ANY INCI- DENTAL COSTS OF REMOVING OR REPLACING DEFECTIVE PRODUCTS. This warranty gives the purchaser specific rights, and the purchaser may have other rights which vary from state to state. Some states do not allow limitations on how long an implied warranty lasts or on the exclusion of incidental or consequential damages, so these limitations or exclusions may not apply to you.