Inductive Conductivity

Similar documents
Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

Toroidal Conductivity Transmitters Series APT4000 Specifications

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

MEAS CAL ALARM WASH CONF APT4000 TC

Stratos MS. Internationally recognizable icons provide operating information and draw attention to unusual operating states.

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Model Q45P/R. ph/orp Monitor...

For very low to medium/high conductivity: Where optimal performance is essential. INGOLD Leading Process Analytics

Low Temperature Zirconia Oxygen Analyzer

Model Q45P/R. ph/orp Monitor...

Dissolved Oxygen Analyzers

Dissolved Oxygen Measurement liquisys S COM 223 / 253

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Toroidal (Electrodeless) Conductivity Sensors Series 5000TC Specifications

Signet V(D) to V(D) PVDF Conductivity Electrodes

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Temperature Controllers

APT2000 Series 2-Wire Contacting Conductivity Transmitters User Manual MU1I-6246 Revision 1 01/00

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Analog Room Pressure Monitor RPC Series

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

I/A Series 716C 1/16 DIN Temperature Controller

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Level Measurement Continuous level measurement Ultrasonic transmitters

/8 DIN Level Indicator

Condumax CLS16 and CLS16D

5000TC Series Toroidal (Electrodeless) Conductivity Sensors. Specification. Overview. Features. Description /00 Page 1 of 8

Universal controller for panel mounting Models CS6S, CS6H, CS6L

OPTISENS TUR 2000 Technical Datasheet

Conductivity Product Name Part No.

Process Alarm Module RTA 421

02/11/2015

Mark 25 Ultrapure Water Conductivity Analyzer

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Smart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control

Gas cylinder scale Model GCS-1

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

UDC 700 Universal Digital Controllers and Indicator Specifications

02/11/2015

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Using the Model 1500 Portable Chilled Mirror Hygrometer

Using the DewTrak II Dew Point/ Humidity Transmitter

WIO200 Water In Oil measuring instrument

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

Turbidity Systems. Inline Turbidity Measurements For More Visibility Into Your Process. INGOLD Leading Process Analytics

User Guide IM/AX4CO4 Rev. K. AX413, AX430, AX433, AX436 & AX438 Single and dual input analyzers for high level conductivity

TDS Conductivity Probe In-Line conductivity measurement

Figure 1 DirectLine DL423 Sensor. Description, continued

873A Series Electrochemical Analyzers ph, Contacting Conductivity, Electrodeless Conductivity, and Resistivity

Chlorine gas leak detector

for Drinking Water Systems

F4 Process Controller Installation and Operation Guide

CLARITY II TURBIDIMETER

Series Temperature Controller Instruction Sheet

Figure 1 DirectLine DL423 Sensor. Description, continued

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

UDA2182 Universal Dual Analyzer

Steam and Water Analysers

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Rosemount 148 Temperature Transmitter. Reference Manual , Rev CA April 2014

WASTEWATER Online UV%Transmission Analyzer

Dew-Point Transmitters and Instruments

Dual Input Toroidal Analyzer

Electronic Flow Switches

PURSense Sanitary Flange Conductivity Sensors

Chlorine / Chlorine Dioxide Measurement liquisys S CCM 223 / 253

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

The Platinum Bullet - ORP. 546 In-Line Submersible. 547 Ball Valve Insertion Assembly. The Pressure Monster. Electrode & Tip Protection Options

DEW POINT HYGROMETER MODEL DPH-2020/2012 BULLETIN DPH-2020/2012 can be used to extend the lower measurement limit of the system.

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

Concise catalogue Water-Industry

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

Sodium Monitor. Data Sheet SS/8036_5. Model Wide measuring range (0.01 gkg 1 to 10mgkg 1 ) covers all power station applications

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

UDA2182 Universal Dual Analyzer

Software Version 2.01 LEVEL MONITOR MODEL 220

Operating Instructions. Condumax CLS15/16/21. Analog sensors For conductive measurement of conductivity in liquids BA01148C/07/EN/01.

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

EC3-X33 Stand-alone Superheat Controller Technical Data

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

PUV, PIR and PFO Series BROCHURE

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Transcription:

Inductive Conductivity THORNTON Leading Pure Water Analytics 7100E Non-Fouling Sensors PEEK or PFA Wetted Parts Excellent Chemical Resistance 0/4 to 20mA Outputs for Conductivity & Tempreature 4 Relays PID Control 7100E Inductive Conductivity System for Reliable Wide-Range Measurement

7100E System 7100E Inductive Conductivity System Key Features Advantages at a glance. The Mettler-Toledo Thornton 7100E inductive conductivity transmitter has an extremely wide measuring range of 0-2000 ms/cm. The unit also provides simultaneous readings of the measured value (conductivity, concentration or salinity) and temperature, clearly portrayed in a wellarranged LC display, with analog outputs for both. Status annunciators indicate the mode of operation. The AC/DC universal power capability allows the transmitter to be connected to almost any power source. Process safety - in the foreground. SensoCheck continuously monitors the sender coil and wiring for short circuits, and the receiver coil for any disruptions. GainCheck allows a manual functional check of the transmitter at any time. In addition, an installed background program carries out an independent, periodic check of all instrument functions. A red LED in the front panel optically signals any alarm condition. A 22 ma alarm signal can be set in the event of a malfunction. Rapid connection and start-up. Plug-in terminals and front panel access allow rapid installation of sensors and output wiring. Instrument mounting configurations include wall, pipe or panel mounting. The robust plastic enclosure can withstand the harshest process conditions with a rating of IP65, NEMA 4X. Simple calibration. Calibration of the transmitter and sensor is carried out either through direct entry of the factory calibrated cell factor or through manual validation of the cell factor using a standard calibration solution. Temperature may also be calibrated to provide more precise automatic temperature compensation of the measured conductivity values. Variety of process adaptions. The sensors can be inserted into a process pipe by means of a threaded bushing or Tri-Clamp fitting. PID proportional, integral, derivative control. Built-in control enables complete loop autonomy where desired. Control output is through relays based on pulse frequency for metering pumps or pulse duration for solenoid valves. Analog outputs are still available for conductivity and temperature. Applications Semiconductor processes can be monitored with sensors of glass-filled PEEK and no wetted metal parts. Process purity requirements are protected. Waste water monitoring reliability is assured with non-fouling inductive sensors even at high conductivity and suspended solids levels. Inductive sensors measure even in concentrated, zero-discharge applications. Deionization Regeneration acid and base concentrations can be controlled reliably and accurately with inductive conductivity measurement. Direct temperature-compensated, % by weight readout is provided for all chemicals used for deionizer and softener regeneration. Pharmaceutical Clean-in-Place (CIP) processes requiring control of chemical concentrations can use inductive conductivity measurement. It can also be used to validate concentrations at the return end of the line and for waste treatment. 2

7100E Inductive Conductivity System Dimensions: inches (mm). 3

7100E System 7100E Inductive Conductivity Transmitter Specifications Conductivity Input Mettler-Toledo Thornton 7250 Series inductive sensors Conductivity Ranges 0.000 to 9.999 ms/cm 00.00 to 99.99 ms/cm 0.000 to 9.999 S/m 000.0 to 999.9 ms/cm 00.00 to 99.99 S/m 0000 to 1,999 ms/cm Concentration Ranges NaCI 0 to 26% (0 to 60 C) HCI 0 to 18% (-20 to 50 C) NaOH 0 to 14% (0 to 100 C) H2SO4 0 to 30% (-17 to 110 C) HNO3 0 to 30% (-20 to 50 C) H2SO4 32 to 84% (-17 to 115 C) H2SO4 92 to 99% (-17 to 115 C) HCI 22 to 39% (-20 to 50 C) HNO3 35 to 96% (-17 to 115 C) NaOH 18 to 50% (0 to 100 C) Salinity Range 0.0 to 45.0% (0 to 35 C) Measurement Error < 1% of measured value + 0.005 ms/cm Temperature Input* Pt100 / Pt1000 / NTC 100 kω Measuring Range Pt: -20 to +200 C / -4 to +392 F NTC: -20 to +130 C / -4 to +266 F Resolution 0.1 C / 1 F Measurement Error 0.5 K; ± 1K with Pt100 Temperature Compensation Linear: 00.00 to 19.99 %/K (Reference temp. 25 C) Non-Linear: natural water to EN 27888 (0 to 35 C) Display 3-1/2 digit liquid crystal display with alarm LED Current Outputs Two, 0 to 20 ma or 4 to 20 ma, max. 10 V, isolated, 22 ma for error message, can be disabled; dedicated to conductivity and temperature Current Characteristics Linear or logarithmic Current Error < 0.3 % of current value ± 0.05 ma Start/End Scale Selectable within the measurement range for ms, S, % by wt, salinity, temperature Minimum Measurement Span Linear: 5% of selected measurement range Logarithmic: 1 decade 4

7100E Inductive Conductivity Transmitter Specifications Cell Factor Range 00.100 to 19.999 Monitoring of Cell Sensocheck : monitoring of sender coil and leads for short circuits, and of the receiver coil for disruption (can be disabled). Relays* 4 SPST relay switching contacts, isolated Relays 1 & 2 for limits, with adjustable NO/NC, hysteresis and delay Optionally, relays 1 & 2 for PID control Relay 3 for system alarm Relay 4 for sensor wash Relay Ratings AC: < 250 V, < 3 A, < 750 VA DC: < 30 V, < 3 A, < 90 W PID Process Controller* Output via relay contacts Proportional Action Controller Gain KC: 0010...9999% Integral Action Reset Time TR: 0000...9999 S Derivative Action Reset Time TD: 0000...9999 S Controller Type Pulse length or pulse frequency controller Pulse Period 0001...0600 S, minimum ON time 0.5 S (pulse length controller) Maximum Pulse Frequency 0001...0180 pulses/minute (pulse frequency controller) Power Supply 20 to 253 VAC/DC, AC: 45 to 65 Hz, approx. 5 VA, 2.5 W Overvoltage category II; Protection class II Ambient Conditions Operating/ambient temperature -20 to +55 C; Transport and storage temperature -20 to +70 C Relative humidity 10 to 95% non-condensing Enclosure Polymer case, PBTP (polybutyleneterephthalate) Installation Wall-mounting hardware, standard Pipe/bracket for 1-1/4 to 2 pipe, φ 40 to 60 mm, with kit ordered separately Control panel, cutout to DIN 43700, with kit ordered separately Dimensions 144 x 144 x 105 mm (5.67 x 5.67 x 4.13 in.) Protection IP 65, NEMA 4X Cable Entry 5 ports for cable glands M20 x 1.5 or 1/2 conduit Weight Approx. 1 kg (0.5 lb.) FM/CSA NI, Class I, Div 2, Group A, B, C, D; T4 EMC EN 61326 EN 61326/A1 EN 61000-4-5, Installation Class 2 * Configurable Description Part No. Inductive Conductivity Transmitter with Wall Mounting Hardware 7100E Panel Mounting Kit for 7100E 52 120 740 Pipe Mounting Kit for 7100E (1-1/4 to 2 Pipe) 52 120 741 5

7100E System 7250 Inductive Conductivity Sensors Features Chemically resistant PEEK (polyetheretherketone) or PFA (perfluoro alkoxy) No metal wetted parts High-Temperature to 180 C (356 F) Wide measuring range to 2,000 ms/cm Unaffected by severe fouling Simple installation of sensors and accessories Variety of process insertion fittings Submersion installation for wastewater treatment Robust sensor design for maintenance-free operation Integrated temperature probe for direct temperature compensation Operation The inductive conductivity sensor consists of two high-grade toroids (coils) which are incorporated concentrically and adjacent to one another in a polymer body. These coils form a current transformer. The sensor is designed so part of the liquid media forms a closed conductive current path passing through the toroids. The primary coil is activated with a sinusoidal alternating voltage, which induces an alternating voltage in the liquid loop (sample medium). In liquids which conduct electricity, this causes a current flow which is proportional to the conductivity of the sample medium. The liquid loop is also acting as the primary winding of the secondary coil which functions as a current transformer. This current is rectified to the correct phase and amplified. If the toroid of the sensor is mounted in a relatively small (< 3 ) pipe, the field around the toroid, and therefore the effective cell factor, will be influenced. In that case, calibration in the pipe is needed to achieve rated accuracy. * PFA version 6 Dimensions: mm (inches).

7250 Inductive Conductivity Sensors & Accessories 7250 Series Sensors Measuring Range Cell Factor Transfer Ratio Installation Weight Temperature Sensor Temperature Response Wetted Material Mounting Thread O-ring / Gasket Cable Lengths Peek PFA 0 to 2,000 ms/cm 0 to 2,000 ms/cm 2.17 2.30 120 120 2 NPT bushing or Tri-Clamp fitting (see table below) 2 NPT bushing or Tri-Clamp fitting (see table below) 0.9 kg (2 lb.) 0.9 kg (2 lb.) Pt 1000 Pt 1000 Approx 5 minutes (90%) Approx 5 minutes (90%) Glass filled PEEK (GF30) Unfilled PFA 1.4435 (316) Stainless Steel 1.4435 (316) Stainless Steel Viton / Viton FEP/PTFE 5, 10 m (16, 33 ft) 5,10 m (16, 33 ft) Temperature -20 to 100 C (-4 to 212 F) -20 to 180 C (-4 to 356 F) -20 to 125 C (-4 to 257 F) Max Pressure Measurement Value Deviation 8 bar (116 psig) ± (0.5% of measurement + 25 µs/cm) 20 bar (290 psig) ± (0.5% of measurement + 1 µs/cm) Cable Jacket Material PVC Silicone 16 bar (232 psig) ± (0.5% of measurement + 25 µs/cm) Silicone Cable Length m (ft) 5 m (16 ft) Part No. 52 002 737 10 m (33 ft) 52 002 738 5 m (16 ft) 52 002 740 10 m (33 ft) 52 002 741 5 m (16 ft) 52 005 424 10 m (33 ft) 52 005 425 A combination of high pressure, high temperature and/or aggressive process medium can reduce sensor life. 7250 Series Insertion Adapters 7250 Series Adapter Dimensions Description A B C Part No. Threaded bushing 2 NPT PVDF 2 NPT SW75 24 (0.95 ) 52 403 453 Sanitary Fitting 2 Tri-Clamp SS 58 084 013 7

Conductivity Standard Solutions Provided for sensor verification and recalibration, conductivity standards are produced, analyzed, and documented in the Mettler-Toledo Thornton ISO 9001 certified facility with processes similar to those used to calibrate high accuracy Thornton conductivity sensors. They are provided with label and certificate with lot number, certified value, expiration date, plus ASTM and NIST traceability data. These standards are analyzed and used at equilibrium with the atmosphere. Standard Accuracy Shelf Life Part No. 1000 µs/cm, 500 ml, KCl ± 1% 12 mo 58 078 003 10,000 µs/cm, 500 ml, KCl ± 1% 12 mo 58 078 004 100,000 µs/cm, 500 ml, KCl ± 1% 12 mo 58 078 005 www.mt.com/thornton Visit for more information Mettler-Toledo Thornton, Inc. 36 Middlesex Turnpike Bedford, MA 01730 USA Tel. +1-781-301-8600 Fax +1-781-301-8701 Toll Free +1-800-510-PURE thornton.info@mt.com Quality certificate. Development, production and testing to ISO 9001. A certified ServiceXXL provider. Subject to technical changes Mettler-Toledo Thornton, Inc. ML0080 Rev.E 06/08 CE Compliant