Technical data LA 9S-TU

Similar documents
Technical data LA 60TU

Technical data LA 28TBS

Technical data LA 60TUR+

Advance Split

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

Starting current with soft starter Fuse protection

Planning guide. Atec.

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

ROOF TOP TYPE UNITS CENTRIFUGAL FANS ENGINEERING DATA MANUAL MODELS Rev. 100

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

Dimplex High efficiency air-to-water heat pump for indoor installation. (Low temperature) Order reference

PUHZ-SHW140YHA PUHZ-SHW230YKA

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

History List. Version Date Update Information New EHS SPLIT TDB Released. (Modify the Spec Note)

WARMTEPOMPEN DIMPLEX. POMPES À CHALEUR DIMPLEX.

NABILATON PRO. The Nabilaton Pro heat pumps consist of MDV brand outdoor units and suitable hydraulic modules from Nabilaton.

Product Range Overview 2010

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

EHS. EHS (Mono, LT, 50Hz)

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

HPWH 300 HPWH 300HE. Installation and Operating Instructions. Hot Water Heat Pump for Outdoor Installation. English FD 9501

Air / Water Heat Pump - Compact Design Modulating 8 18 kw

your tree NEW TREE for you Several facts on trees: Follow our Green Tree heat pumps

Technical description. Atec.

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

Heat pump & cooling unit in one

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

VIESMANN. VITOCAL Air/water heat pumps. Technical guide. VITOCAL 300-A Type AWC-I and AW-O. VITOCAL 350-A Type AWH-I and AWH-O

HIGH-POWER HEAT PUMPS. Up to 300 kw

50A KP 70A KP 90A KP 120A KP 150A KP 210A

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

NATURAL HEATING MACHINE

Saving energy comes naturally to us.

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

NIBE SPLIT ACVM 270 Air/water heat pump

HT V2 HT Split

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Technical data. Danfoss DHP-A

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

Do you want a versatile solution

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Starting current with soft starter Fuse protection

SWIMMING POOL HEAT PUMPS

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

DESIGN & TECHNICAL MANUAL

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

Multi Inverter Air Conditioning Condensing Units - Summary

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

REMKO HYBRID HEAT PUMPS

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

AIR GOLF MAXI PLUS. Heat Source Air. Technical data: High-efficiency air/water heat pumps. for tfl. max. 65 C

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

High temperature air-to-water heat pumps

Starting current with soft starter Fuse protection. Heat source connection

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q ***

Product Range. Overview 2015.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Air to water Heat Pump System

DHP-H Varius Pro+/DHP-L Varius Pro+

Pro heat station brine

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

INVERTER 9-12 DC INVERTER 9 SF

Air/water - Heat pumps

Technical Data Ducted Three Phase Split System Air Conditioner

CM R-410A High Efficiency Water Source Heat Pump

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Technical data. Danfoss DHP-L

EHPA Testing Regulation

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Introduction. General requirements when using the heat pump

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

Transcription:

Technical data LA 9S-TU Device information LA 9S-TU Design - Heat source Outside air - Model Universal design - Regulation - Thermal energy metering Integrated - Installation location Outdoors - Performance levels Operating limits - Min. return temperature / Max. flow temperature 7) 8 / 6 C +/- - Lower operating limit heat source (heating operation) / Upper operating limit heat source (heating operation) - / C Flow / sound - Max. heating water flow rate / Pressure drop,5 m³/h / 99 Pa - Heat source flow (min.) / Heat source flow (max.) / 7 m³/h - Sound power level 5 db (A) - Sound power level in accordance with EN (lowered operation) 5 db (A) - Sound pressure level in m ) 5 db (A) - Sound pressure level in m (lowered operation) ) 5 db (A) Dimensions/weight and filling quantities - Dimensions (W x H x D) ) 9 x 65 x 75 mm - Weight 5 kg - Thread type, heating connection / Connection heating G / ¼ inch - Refrigerant / Amount of refrigerant R4A /,9 kg - Oil type / Oil quantity Polyolester (POE) /, l - Water content,6 l Electrical connection - Rated voltage / Fuse protection /N/PE ~4 V, 5 Hz / C A - Control voltage /N/PE ~ V, 5 Hz - Fuse protection HP with separate infeed C A - Degree of protection IP 4 - Initial current limiter Yes - Starting current A - Rotary field monitoring Yes - Nominal power consumption according to EN at A7/W / Maximum electric power consumption ),7 /, kw - Nominal current at A7/W / Nominal current cos phi, A /,8 - Power consumption of the compressor protection / Control compressor protection 7 W / thermostatically controlled - Power consumption of the fan W Complies with the European safety regulations Additional model features - Type of defrosting Reverse circulation - Water in device protected against freezing 4) Yes Heat output / coefficient of performance (COP) according to EN : ) Heating compressor W W W A-7 5,5 kw /, 5,4 kw /,6 5, kw /, A 7, kw / 4, 7, kw /, 6,6 kw /,6 A7 8,4 kw / 4,8 8, kw /,7 8, kw /, A 8,9 kw / 5, 8,8 kw / 4, 8,5 kw /,4 Heating compressor W A-7 5,5 kw /, A 7, kw / 4, A7 8,4 kw / 4,8 A 8,9 kw / 5, Note: ) This data indicates the size and capacity of the system according to EN. For an analysis of the economic and energy efficiency of the system, the bivalence point and regulation should be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on maintenance, commissioning and operation can be found in the respective sections of the installation and operating instructions. The specified values have the following meaning, e.g. A7 / W: Heat source temperature 7 C and heating water flow temperature C. ) The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of C. The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 6 db(a), depending on the installation location. ) Please note that additional space is required for pipe connections, operation and maintenance. 4) The heat circulating pump and the heat pump manager must always be ready for operation. 7) Depending on the heat pump type and refrigerant used, the maximum flow temperatures in heating operation may be reduced when the outside temperature falls. Further information can be found in the operating limit diagram for the heat pump. If the supporting feet are used, the level can increase by up to db (A). /5

Characteristic curve heating LA 9S-TU 5 4 9 8 7 6 5 4 Heat output in [kw] Conditions: Heat source flow (min.), m³/h Water outlet temperature in [ C] -5 - -5 - -5 5 5 5 4 Power consumption (incl. proportion of pump output) 8 Pressure drop in [Pa] 6 Liquefier 4-5 - -5 - -5 5 5 5 4 Coefficient of performance (incl. proportion of pump output) 8 7 6 5 4-5 - -5 - -5 5 5 5 4 8 6 4,,5,,5, Heating water flow rate in [m³/h] /5

Operating limits diagram LA 9S-TU Heating water temperature [ C] 75 7 65 6 5 4 5 5 - -5 - -5 - -5 5 5 5 4 Note: The maximum possible flow temperature and the operating limits vary by +- K due to component tolerances. The minimum volume flow specified in the device information must be ensured at the lower operating limit. In mono energy operating mode with the heating element activated, the maximum flow temperature increases by approximately K. /5

Dimension drawing/foundation plan LA 9S-TU....,5m 4.....,m,m,m,5m,69m,m.. 5. 5., m 5. 5.4.8 5.5.7.6 4/5

Dimension drawing/foundation plan LA 9S-TU - Legend. Hydraulic connections -. Flow -. Return -. Flow (optional) -. Return (optional) -. Domestic hot water flow -.4 Hot water return -.5 Heat source flow -.6 Heat source return -.7 Filling and drain cock -.8 Combined heating/domestic hot water return. Feed-throughs/pipes -. Feed-through - condensate pipe -. Feed-through - electric wire -. Feed-through condensate pipe (optional) -. Feed-through electric wire (optional) -.5 Condensate drain -.6 Condensate pipe -.7 Electric empty conduit -.8 District heating pipe. Transport/operation -. Ring bolt for crane transport -. Transport tunnel -. Transport opening for carrier pipe -.4 Operator side 4. Air circuit - 4. Direction of air flow - 4. Main wind direction with free-standing installation - 4. Air inlet - 4.4 Air outlet - 4. Air inlet (optional) - 4.4 Air outlet (optional) 5. Foundation - 5. Foundation - 5. Green field - 5. Earth - 5.4 Layer of gravel - 5.5 Frost line - 5.6 Contact surface floor frame (all-round) Notes: The condensate pipe must lead to the drainage facilities. The frost line can vary according to the climatic region. The regulations of the countries in question must be observed. For unprotected free-standing installation, heat pumps without deflector hoods must be installed at right angles to the main wind direction. Depending on the heat pump type, not all points of the legend are included in the drawing. 5/5