Air-Cooled Thermosyphon for Press-Pack Stack of Semiconductors

Similar documents
Thermal Performance of a Loop Thermosyphon

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

15. Heat Pipes in Electronics (1)

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

To investigate the surface properties for increasing efficiency of solar water heater

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

2. HEAT EXCHANGERS MESA

Operation of a Two-Phase Reverse Loop Thermosyphon

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Compression of Fins pipe and simple Heat pipe Using CFD

Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

Capillary Tube and Thermostatic Expansion Valve Comparative Analysis in Water Chiller Air Conditioning

Mini Vapour Cycle System For High Density Electronic Cooling Applications

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

Transcritical CO2 Bottle Cooler Development

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Purdue e-pubs. Purdue University

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

Characterization of a Heat Sink with Embedded Heat Pipe with Variable Heat Dissipating Source Placement for Power Electronics Applications

Effects of Non-Uniform Refrigerant and Air Flow Distributions on Finned- Tube Evaporator Performance

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

TWO-PHASE MICRO-CHANNEL HEAT SINK FOR SPACE CRAFT THERMAL CONTROL

Passive cooling of telecommunication outdoor cabinets for mobile base station

Performance Analysis of a Miniature-Scale Vapor Compression System for Electronics Cooling: Bread Board Setup

Numerical study of heat pipe application in heat recovery systems

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

How Wicks and Orientation

Experimental investigation of the dynamic thermohydraulic behaviour of vertical tube reboilers

Global Journal of Engineering Science and Research Management

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

Properties of a two stage adiabatic demagnetization refrigerator

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Experimentation of Heat Pipe Used In Nano-Fluids

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Flow Boiling of R245fa in a Microgap with Integrated Staggered Pin Fins

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV)

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

Enhancing the performance of the domestic refrigerator with hot gas injection to suction line

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

SCIENCE CHINA Technological Sciences

Study on a novel variable capacity technology and control strategy for refrigerated shipping container unit

Special Aspects in Designing High - Frequency Betatron

COOLING SYSTEM FOR HERMETIC COMPRESSOR BASED ON THE LOOP THERMOSYPHON

Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe

Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling

Effect of Parameters on Internal Flow Patterns of a Top Heat Mode Closed-loop Oscillating Heat Pipe with Check Valves (THMCLOHP/CV)

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

INSTRUMENTATION AND EVALUATION OF COMMERCIAL AND HOMEMADE PASSIVE SOLAR PANELS

Heat sinks for electronic cooling applications

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

EXPERIMENTAL STUDY OF DUAL EVAPORATOR LHP WITH TWO COMPENSATION CHAMBERS

Air-Cooling Evaporators

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

Developing Two-Phase Flow Distribution in Horizontal Headers With Downward Minichannel-Branches

Experimental Study on Thermal Behavior of a Stainless Steel-Di Water Flat Plate Heat Pipe

Pocket Dilution Cooler

FABRICATING A HEAT PIPE STRUCTURE WITHIN A RADIATING PLATE FOR ELECTRONICS FAN-LESS COOLING

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

2.2. General view of Microchannel Heat Exchangers

Basic CFD model of heat pipe

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

Technology Application of Environmental Friendly Refrigeration (Green Refrigeration) on Cold Storage for Fishery Industry

INVESTIGATION OF A TWO-PHASE FLOW NATURAL CIRCULATION LOOP WITH DIVERGENT MICROCHANNEL EVAPORATOR

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Modeling of a Von Platen-Munters diffusion absorption refrigeration cycle

Effects of seawater flow rate and evaporation temperature on performance of Sherbet type ice making machine

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

VISUAL STUDY ON TWO-PHASE FLOW IN A HORIZONTAL CLOSED-LOOP OSCILLATING HEAT PIPE , Thailand , Thailand

Integration of a Pulsating Heat Pipe in a Flat Plate Heat Sink

Sodium Heat Pipes for Spacecraft Fission Power Generation

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Performance Evaluation of a Plug-In Refrigeration System Running Under the Simultaneous Control of Compressor Speed and Expansion Valve Opening

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

IJARI. 1. Introduction: Heat Pipes. Volume 3, Issue 3 (2015) ISSN International Journal of Advance Research and Innovation.

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Research Article Analyzing the Heat Transfer Property of Heat Pipe Influenced by Integrated Cooling Apparatus

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE

Drying rate 1. Section B to C of the curve, known as the constant rate periods, represents removal of unbound water from the product.

Energy Transfer Based Test Method Development and Evaluation of Horizontal Air Flow Re- Circulatory Air Curtain Efficiencies

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Ultraviolet radiation detector to obtain the rate of particles at different heights

High Temperature Water-Titanium Heat Pipes for Spacecraft Fission Power

Performance investigation of Air-conditioning system using ejector as expansion device

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Transcription:

Journal of Physics: Conference Series PAPER OPEN ACCESS Air-Cooled Thermosyphon for Press-Pack Stack of Semiconductors To cite this article: M. Habert and B. Agostini 2016 J. Phys.: Conf. Ser. 745 032110 View the article online for updates and enhancements. This content was downloaded from IP address 148.251.232.83 on 28/01/2019 at 23:30

Air-Cooled Thermosyphon for Press-Pack Stack of Semiconductors M. Habert, B. Agostini ABB Corporate Research, Baden-Daettwil, Switzerland E-mail: mathieu.habert@ch.abb.com Abstract. Medium voltage converters make extensive use of press-pack semiconductors in several products ranging from drives to rectifiers. Better cooling brings significant advantages: the possibility of drawing more power using the same semiconductors and thus effectively extending the converter operating range, a higher reliability, and cost savings on semiconductors for equal converter power. In this article, the experimental characterization of a baseplate to air thermosyphon for the double-side cooling of press pack thyristor modules in presented. Effects of refrigerant fluid filling, heat load, air temperature and air flow on the junction temperature were studied in both vertical and horizontal stack configuration. Vertical evaporator yields the best performance with 120 C junction temperature at 40 C air and 30W/cm 2 heat loss. 1. Introduction Heat sinks are currently used in air cooled converters. An increase in the heat transfer rate would mean an increase in size and air velocity, which would in turn increase cost and noise, or switch to water cooling. Furthermore, the heat spreading from the semiconductor into the heat sink base is a limiting feature. Embedding heat pipes or a vapor chamber could help alleviating the problem, but at a considerable cost. Even then the heat transfer area would have to be significantly augmented to handle a power that is almost or more than double the maximum currently handled. This would call for a radical modification of the heat sink and of its manufacturing process. Two-phase thermosyphon coolers are an intermediate solution between forced air and water coolers that cope with performance, reliability and maintenance-free operation. Thermosyphon are passive system based on the density difference between the vapour and liquid phases of the cooling medium. Early in 1988, Bordignon et al. [1] developed a two-phase thermosiphon for large thyristors cooling that enabled the full utilization of their current handling capability. Furthermore, this solution avoids the parallel connection of thyristors with increased performance and reliability. Kuwahara et al. [2] built a thermosyphon based cooling system for a traction inverter. The semiconductor devices are a press-pack stacked between evaporators connected to a common condenser with an intermediate liquid/vapor separator for 3kW cooling capacity for each power device. More recently, Derakhshanfar et al. [3] proposed an air-cooled two-phase thermosyphon solution for HVDC breaker cooling that can handle up to 5kW losses for each power module. The low mass flow rate of the two-phase cooling medium obtained by natural convection usually limits their application to heat density up to 15-20W/cm 2. It is possible to develop two-phase natural Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by Ltd 1

convection system that can reach higher heat loss density by using surface enhancements such as coating, micro-porous structure, mesh, wick etc. The present study shows the thermal characterization of an air-cooled two-phase thermosyphon for press-pack stack of thyristors with vertical and horizontal evaporators. 2. Thermosyphon for press-pack of semiconductors The working principle of a thermosyphon is explained in Figure 1. The thermosyphon is typically composed of the following four sections: 1. the evaporator where the heat is applied and the liquid is partially evaporated, 2. the riser where the vapour rises by natural convection, 3. the condenser where the vapour condenses back into the liquid phase 4. the downcomer where the liquid falls down by gravity to the bottom of the evaporator Figure 1: Looped thermosyphon principle. [4] Due to the influence of gravity, a thermosyphon can work only in a vertical position (or with a limited angle of inclination and degraded thermal performance). Furthermore, the condenser must be located above the evaporator for the fluid circulation to take place. Medium voltage converter requires the use of electrically insulating riser and downcomer, through which the fluid flows and that provides electrical isolation between evaporator and condenser. A cost-optimized two-phase thermosyphon cooler was developed and manufactured using standard aluminium plate and bar condenser for the condenser and Nokoloc brazing process for the evaporator. The evaporator structure is made of aluminium multi-port extruded tubes brazed together to provide both a large heat transfer area and a good fin efficiency, and thus enabling good thermal spreading and bubble pumping. Figure 2 shows a sectional view of the evaporator internal structure. Internal liquid distributor and vapor collector were designed to minimize the pressure losses in the evaporator. The entire cooling system is shown Figure 2. The evaporator section is 18 x 134 mm with 1.5mm channel hydraulic diameter, the plate and bar condenser is 500 x 100 x 100mm with wavy fins and the vapor riser and liquid downcomer are 12mm internal diameter. 2

Figure 2: Thermosyphon design 3. Experimental set-up A schematic of the test facility is shown in Figure 3. Figure 3: Experimental set-up and thermocouple location (schematics) It is composed of different elements: A test section equipped with the following instrumentation: - 2 circular heating elements (diameter 3 inches) equipped with 5 electrical cartridges (1000W heating power each) - 1 thermosyphon cooler 3

- 1 absolute pressure sensor and 4 differential pressure transducers - Thermocouples at evaporator and condenser inlet and outlet manifolds - 24 thermocouples (12 on each side) directly in contact with the evaporator baseplate as shown on Figure 3. 2 Eurotherm 16A 230V single-phase power controller An inlet air distribution cone equipped with 1 thermocouple (middle) and an air pressure measurement port An outlet air distribution cone equipped with 3 thermocouples (top, middle and bottom) and an air pressure measurement port A differential air pressure sensor All signals are acquired through a National Instruments SCXI box connected to a laptop running Labiew. For temperature measurement a 1102 module with a cut off frequency at 2 Hz is used. The measuring devices and their accuracy are presented in Table 1. Instrument Type Range Uncertainty Test facility Thermocouples Thermocoax, type K, shielded, class 2-40 1200 C ± 0.1 K calibrated (all acquisition chain) Fluid pressure sensor Omega PX 409 0-500 psi ± 0.08 % Diff. pressure sensor Omega PX 409 0-2.5 psi ± 0.1 % Data acquisition National Instruments, SCXI 1000, modules 0-10 V ± 0.02 % 1102, 1124, 1600, 1303, 1325 Air pressure drop Huba control 0-500 Pa ± 2 % Air mass flow rate ABB Topaz 80-4000 kg/h ± 0.1 % Power supply Eurotherm TE-16A 230V, 16 A ± 1 % Calibration material Refrigerated bath Lauda, R207-40-200 C ± 0.2 K Precision thermometer + Platinum Probes Omega, DP97-50-400 C ± 0.04 K Table 1: Measuring device and accuracy The test setup is inserted into a wind tunnel equipped with a centrifugal fan, a mass flowmeter, a preheater, and an air-water heat exchanger connected to a chiller in order to keep the air at a preset temperature. All the thermocouples were calibrated using an Omega DP97 precision thermometer with platinum probes to measure the reference temperature and a Lauda R207 chiller to control the temperature. The uncertainty of the calibrated thermocouples is ± 0.1 K (it is ± 2.5 K if not calibrated). 4. Data reduction The fluid filling ratio is defined as the ratio of the volume of fluid filled in the system divided by the internal volume of the loop thermosiphon unit. The mass of fluid was measured with a precision of 10g leading to an uncertainty of 0.3% on the fluid filling ratio. The total maximum thermal resistance is calculated as follows: Tb,max Tair,in Rth Q (1) 4

where T b,max is the maximum baseplate temperature The condenser thermal resistance is calculated as follows: Tf, c Tair,in Rth,c Q The evaporator thermal resistance is calculated as follows: Tb,max Tf,e Rth,e Q The closing relation is given by: R th R th,e R th,c (2) (3) (4) The energy balance, calculated as the relative difference between the electrical power injected in the baseplate and the heat extracted by the air stream, was kept below 10%. UI m air Cp air ( T air, out Tair, in ) Q UI (5) 5. Test results All measurements were performed at steady state, i.e. when all the over-temperatures (difference between measured temperature and ambient air temperature) are stable with time. Tests were performed with both vertical and horizontal evaporator orientations as shown on Figure 4: Figure 4: Evaporator orientation (schematics) 5.1. Effect of fluid filling ratio Figure 5 shows the variation of the maximum thermal resistances at 2000W heat losses (1000W per side) for fluid fillings between 25 and 85%. 5

Figure 5: Fluid filling optimization curve at 2000W losses At low fluid filling, the amount of vapor at the exit of the evaporator is higher, there is less liquid to wet the evaporator wall constantly so that the evaporator performance decreases. At high fluid filling there is more liquid in the thermosyphon so that the condenser is partially flooded. As a consequence the saturation temperature inside the thermosyphon has to increase in order to allow the condenser to condense all the vapour over a shorter flow length and the condenser performance is decreasing. Performance of the thermosyphon is less affected by the fluid filling with vertical evaporator than with horizontal evaporator. The minimum value of fluid filling to avoid dryout is ca. 42%, the maximum fluid filling to avoid condenser flooding is ca. 71%. The temperature difference on the evaporator baseplate is strongly affected by the fluid filling at high heat loads: the more filling, the more uniform cooling due to a better channel rewetting. Similar observation can be made between top and bottom evaporator baseplate: the highest filling minimizes the difference between top and bottom. Temperature difference is reduced by half in vertical orientation: the difference between both side of the evaporator is almost negligible (below 4 C) even if the liquid/vapour flow maldistribution are amplified when increasing the heat load. 71% was chosen as optimum fluid filling for the following tests as it is a good compromise between cooling performance and temperature uniformity. 5.2. Effect of heat load Tests were performed with 700m 3 /h air flow and 40 C air inlet temperature. Figure 6 shows the thermal resistances for heat loads up to 3500W. 6

Figure 6: Max. thermal resistances as a function of heat load With horizontal evaporator, the evaporation thermal resistance is first decreasing at low heat load before to remain constant and start increasing at higher heat loads. This is explained by the fact that with sufficient channel wetting the boiling heat transfer coefficient is an increasing function of the heat load as the number of activated nucleation sites is increasing. When channel dry-out starts, the evaporator performance decreases. In vertical orientation, no channel dry-out is observed and the evaporator thermal resistance is decreasing monotonically with increasing heat load. Figure 7: Baseplate temperature uniformity as a function of heat load The difference of performance between horizontal and vertical evaporator is probably due to the liquid maldistribution between the top and bottom channels and the bubbles rising from bottom to top which leads to less efficient channel rewetting on the top side of the evaporator. As the consequence, the temperature uniformity on the baseplate is higher in horizontal orientation as shown on Figure 7. 7

Having the mini-channels in the vertical direction helps the bubble to rise to the vapor collector and riser and at the same time, the bubbles push the liquid to the top of the channel which helps rewetting of the potential dry patches. Figure 8 shows the performance map of the air-cooled two-phase thermosyphon cooler with vertical and horizontal evaporator Figure 8: Temperature rise as a function of heat density Vertical evaporator can dissipate 31.4 W/cm 2 and 36.6 W/cm 2 with respectively 43.3 C and 51.1 C temperature rise, whereas only 20.9 W/cm 2 and 26.2 W/cm 2 could be dissipated with horizontal evaporator. This corresponds to ca. 33% more losses for the same temperature rise. 6. Conclusions A high performance air-cooled insulated thermosyphon was designed and characterized in an extensive experimental campaign with evaporator in vertical and horizontal orientation. Vertical evaporator yields the best performance with 120 C junction temperature at 40 C air and 30W/cm 2 heat loss. The vertical evaporator is the preferred one with lower hot spot temperature and better temperature uniformity on the baseplate. Performance of horizontal evaporator is suspected to be limited by vapor/liquid maldistribution leading to channel dry-out. References [1] Bordignon P., Ragni A., Latrofa E., Casarosa C., Two-phase thermosyphon device for the large thiristors cooling, 19th IEEE Power Electronics Specialists Conference, Kyoto, Japan, 1988 [2] Kuwahara H., Takahashi K., Nakajima T., Suzuki O., Takasaki T., Enhancement of Two-Phase Thermosyphon for Cooling High Heat Flux Power Devices, Int. Conference on Thermal Phenomena, Washington, 1994 [3] Derakhshanfar R., Jonsson T.U., Steiger U., Habert M., Hybrid HVDC breaker A solution for future HVDC system, CIGRE, Paris, 2014 [4] Agostini F., Agostini B., Flexible two-phase thermosyphon for power electronic cooling, IEEE 33rd Int. Telecommunications Energy Conference, Amsterdam, 2011 8