CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

Similar documents
CR A-F-A-E-HQQE 3x400/ HZ

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR20-07 A-F-A-E-HQQE 3x400/ HZ

TP /4-A-F-A-BQQE 400D 50HZ

SL EX.4.51D

SL S.S.N.51D

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

Company name: Created by: Phone:

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz

GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz

CombiBloc Close-coupled centrifugal pumps

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

Lenntech. Tel Fax bar. Multistage Pumps.

Chemical Pumps Vertical Chemical Pump Type TNP

A Series. 60 Hz. Horizontal Multistage Centrifugal Pumps AHC/AHI, AHBI/AHBS ISO Vol. PIAH-18091

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

Transformer oil coolers BETA & CETA

Inline Pumps LR/LMR & LRZ/LMZ, LER & LEZ. Lenntech. Tel Fax

MARLOW PUMPS RECIRCULATION

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

2CP DATA SHEET. Horizontal Two Stage Centrifugal Pumps 2CP 32/210B 2CP 32/200B 2CP 32/200C

CAP SERIES SEWAGE AND WASTE WATER PUMPS

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

Specially Designed Waste Water & Sewage Pumps

TYPE LF/LC/LCV END SUCTION PUMPS

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

TECHNICAL DESCRIPTION

dualarm Vertical In-Line Pumps

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

IMMERSIBLE PUMPS FOR INDUSTRY

Upompe Primeflo XP7 chemical self-priming centrifugal pumps

K4RH(X) Solids-Handling Pumps

K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Wilo IL Vertical Split-Coupled Inline Pumps

Combi Modular System. Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610

our contribution for Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps environmental protection Type SCM PN40

SECTION STEAM CONDENSATE PUMPS

CombiBloc. Close-coupled centrifugal pumps

TYPE VSM/VSMS VERTICAL SPACE MISER PUMPS

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

CombiPrime Self-priming centrifugal pumps

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

EVMSU - Vertical Multistage Pumps. Product Catalog

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

KEENER GRINDER PUMPS

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

For calls outside the UK Telephone or Fax TETRA PAK PUMPS FREEPHONE: Centrifugal Pump Single Shaft Seal Type ALC-1

Vogel Pumpen. Vogel Pumpen. Vogel - Blockpumps. Design LMN / LM

Volute Casing Pumps. Vogel Series LN/L ACCORDING TO EN 733 DE: +41 (0) FR: +41 (0)

Self-priming centrifugal pumps

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

Pumps Mixers Aeration Controls Services SCANPUMP SPLIT CASING PUMP Z22.

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

UP/UPS-B/UPN Hot Water Service Circulators

Excellent Engineering Solutions. Solids Handling Pumps. Recessed Vortex Impeller Pumps CLEAR LIQUID

Vertical Ring-section Pump WKTB. Type Series Booklet

DUPLEX CONDENSATE TANK SYSTEM

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

SECTION STEAM CONDENSATE PUMPS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

INSTRUCTION AND REPAIR MANUAL

STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP

Selfpriming Centrifugal Pumps. Type HZS/HZSA

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

AC6/6H & AC8/8H Horizontal Metric Models

GRUNDFOS PLUMBING & HVAC PRODUCTS

PUMP. Horizontal Multi-Stage Pump. Type MS SERIES DIMENSION. Model MSL MSH (2 pole motor drive) APPLICATIONS companion flange (SS) Foot valve

470 Series Stamped Stainless Steel Pumps

GRUNDFOS DATA BOOKLET MAGNA3. Circulator pumps 60 Hz

Pumps Motors ISO 9001 Company

Control unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr

Advance Release September 2009

Series SR Compact Centrifugal Mag-Drive Pumps. WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec

Transcription:

GRUNDFOS DATA BOOKLET CR5-9 A-FGJ-A-E-HQQE 1x2/24 5HZ Grundfos Pump 96537532 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96537532/cr-5-9-a-fgj-a-e-hqqe.html info@lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89 BE > THINK > INNOVATE

Position Qty. Description 1 CR 5-9 A-FGJ-A-E-HQQE Product No.: 96537532 Note! Product picture may differ from actual product Vertical, multistage centrifugal pump with suction and discharge ports on same the level (in-line) enabling installation in a horizontal one-pipe system. The pump head and base are in cast iron all other wetted parts are in stainless steel. A cartridge shaft seal ensures high reliability, safe handling and easy service and access. Power transmission is via a split coupling. Pipework connection is via combined DIN-ANSI-JIS flanges. The pump is fitted with a 1-phase, fan-cooled asynchronous motor. Further product details Steel, cast iron and aluminium components have an epoxy-based coating made in a cathodic electro-deposition (CED) process. CED is a high-quality dip-painting process where an electrical field around the products ensures deposition of paint particles as a thin, well-controlled layer on the surface. An integral part of the process is a pretreatment. The entire process consists of these elements: 1) Alkaline-based cleaning. 2) Zinc phosphating. 3) Cathodic electro-deposition. 4) Curing to a dry film thickness 18-22 my m. The colour code for the finished product is NCS 9/RAL 95. Pump A standard split coupling connects the pump and motor shaft. It is enclosed in the pump head/motor stool by means of two coupling guards. The pump head, pump head cover and flange for motor mounting is made in one piece. The pump head has a combined 1/2" priming plug and air vent screw. 1/8

The pump is fitted with a balanced O-ring seal unit with rigid torque transmission system. This seal type is assembled in a cartridge unit which makes replacement safe and easy. Due to the balancing, this seal type is suitable for high-pressure applications. The cartridge construction also protects the pump shaft from possible wear from a dynamic O-ring between pump shaft and shaft seal. Primary seal: - Rotating seal ring material: Silicon carbide (SiC) - Stationary seat material: Silicon carbide (SiC) This material pairing is used where higher corrosion resistance is required. The high hardness of this material pairing offers good resistance against abrasive particles. Secondary seal material: EPDM (ethylene-propylene rubber) EPDM has excellent resistance to hot water. EPDM is not suitable for mineral oils. The shaft seal is screwed into the pump head. The chambers and impellers are made of stainless steel sheet. The chambers are provided with a PTFE neck ring offering improved sealing and high efficiency. The impellers have smooth surface, and the shape of the blades ensure a high efficiency. The base is made of cast iron. The flanges and base are cast in one piece. The discharge side of the base has a combined drain plug and bypass valve. The pump is secured to the foundation by four bolts through the base plate. Motor The motor is a totally enclosed, fan-cooled motor with principal dimensions to IEC and DIN standards. The motor is flange-mounted with tapped-hole flange (FT). Motor mounting designation in accordance with IEC 634-7: IM B 14 (Code I) / IM 361 (Code II). Electrical tolerances comply with IEC 634. The motor has built-in thermal protection (PTO current and temperature sensors) in accordance with IEC 634-11 and requires no further motor protection. The protection reacts to both slow- and quick-rising temperatures, e.g. constant overload and stalled conditions. As the thermal protection incorporates automatic reset, the motor must be connected in a way which ensures that the automatic reset cannot cause accidents. Technical data Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Water 253.. 393 K 293 K 998.2 kg/m³ 2/8

Position Qty. Description Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Approvals on nameplate: Curve tolerance: Materials: Pump housing: Impeller: 2767 rpm 5.8 m³/h 42.2 m HQQE CE,TR ISO 996:1999 Annex A Cast iron EN-JL13 ASTM A48-3 B Stainless steel DIN W.-Nr. 1.431 AISI 34 Installation: Maximum ambient temperature: 313 K Max pressure at stated temp: 25 bar / 1 C 25 bar / - C Flange standard: DIN Pipe connection: DN 25 / DN 32 Pressure stage: PN 16 / PN 25 Flange size for motor: FT115 Electrical data: Motor type: 9LB IE Efficiency class: NA Number of poles: 2 Rated power - P2: 1.5 kw Power (P2) required by pump: 1.5 kw 1.5 kw Mains frequency: 5 Hz Rated voltage: 1 x 2-23/24 V Rated current: 9,9/8,9 A Starting current: 39 % Cos phi - power factor:,98/,99 Rated speed: 275/274 rpm Motor efficiency at full load: 72-7 % Enclosure class (IEC 34-5): 55 (Protect. water jets/dust) Insulation class (IEC 85): F Others: Minimum efficiency index, MEI :.57 Net weight: 4.5 kg Gross weight: 43.2 kg Shipping volume:.8 m3 3/8

96537532 CR 5-9 5 Hz H [m] 65 CR 5-9, 1*23 V, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ eta [%] 6 55 5 1 45 9 4 8 35 7 3 6 25 5 4 15 3 1 5 1.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. 5.5 6. 6.5 7. 7.5 8. P [kw] Q [m³/h] NPSH [m] 2. 8 P1 1.5 6 1. P2 4.5 2. 4/8

Description Value Product name: CR 5-9 A-FGJ-A-E-HQQE Product No: 96537532 EAN number: 57397593547 Technical: Speed for pump data: 2767 rpm Rated flow: 5.8 m³/h Rated head: 42.2 m Head max: 58.3 m Impellers: 9 Shaft seal: HQQE Approvals on nameplate: CE,TR Curve tolerance: ISO 996:1999 Annex A Pump type: CR 5 Stages: 9 Pump version: A Model: A Materials: Pump housing: Impeller: Material code: Code for rubber: Cast iron EN-JL13 ASTM A48-3 B Stainless steel DIN W.-Nr. 1.431 AISI 34 A E H [m] 6 55 5 45 4 35 3 25 15 1 5 1 2 3 4 5 6 7 P [kw] 1.5 1..5. 19 x 24.5 CR 5-9, 1*23 V, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ ø14 ø1 ø89 4 x ø13.5 ø35 18 2 Q [m³/h] P1 P2 eta [%] 1 9 8 7 6 5 4 3 1 NPSH [m] 6 4 2 Installation: Maximum ambient temperature: 313 K Max pressure at stated temp: 25 bar / 1 C 25 bar / - C Flange standard: DIN Connect code: FGJ Pipe connection: DN 25 / DN 32 Pressure stage: PN 16 / PN 25 Flange size for motor: FT115 139 178 321 G 1/2 G 1/2 49 G 1/2 75 1 141 25 Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Water 253.. 393 K 293 K 998.2 kg/m³ Electrical data: Motor type: 9LB IE Efficiency class: NA Number of poles: 2 Rated power - P2: 1.5 kw Power (P2) required by pump: 1.5 kw 1.5 kw Mains frequency: 5 Hz Rated voltage: 1 x 2-23/24 V Rated current: 9,9/8,9 A Starting current: 39 % Cos phi - power factor:,98/,99 Rated speed: 275/274 rpm Motor efficiency at full load: 72-7 % Enclosure class (IEC 34-5): 55 (Protect. water jets/dust) Insulation class (IEC 85): F Motor protec: PTO Motor No: 8521576 Others: 5/8

Description Value Minimum efficiency index, MEI :.57 Net weight: 4.5 kg Gross weight: 43.2 kg Shipping volume:.8 m3 6/8

96537532 CR 5-9 5 Hz 139 178 75 ø89 ø1 ø14 49 321 G 1/2 G 1/2 G 1/2 19 x 24.5 1 ø35 4 x ø13.5 141 18 25 2 Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details. 7/8

96537532 CR 5-9 5 Hz Note! All units are in [mm] unless others are stated. 8/8

Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date. All information is copyright Grundfos. info@lenntech.com www.lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89